HomeMy WebLinkAboutPLANS. � J
o
Y TOP HEADER RUBBER COUPLING COLLECTOR COUPLING
DISTANCE DECREASES FOR
t P-P-ER HOLD -DOWN -CLAMP RBAYS_EINCROgCHIN_G111PR_SSSURE _
B ; 10rO12' ZONE 2 AND/OR 3 HOSE CONNECTOR W v'
SOLAR PANELS (SEE DETAIL A) (2 PER PANEL MIN.) COLLECTOR HEADER 2.00" I.D. °
NOT > 48" CTC, NOT < 16" CTC (2) NO. 14 x 2" MIN SS HEX U
—WASHER HEAD OR SHEET w S
METAL SCREW PER MOUNT N a W a;
N "WITH
INTO PLYWOOD COLLECTOR TUBES � o H
- SHEATHING OR ONE SCREW
EO
WITH FULL EMBEDMENT IN-- a Z gg
RAFTER OR TRUSS EXISTING ROOFING aa W
W K = a U
W
1" DIA SS s
FENDER WASHER MINIMUM 1/2" O.S.B. OR 1/2" CDX ,
PER SCREW PLYWOOD DETAIL A SHEATHING BYOTHERS)
THING (DESIGN OF MTh
PANEL (TYP.)
;f
L- BOTTOM HEADER
PANELS
SCALE= N.1.5.
��l
9
eck,�
ATTACHMENT HARDWARE
NOTE: CONTRACTOR TO USE OEM ATTACHMENT PARTS ONLY
(SEE DETAIL B)
MOUNT A - (2) NO.14 x 2" MIN
SS HEX WASHER HEAD OR
SHEET METAL SCREW PER
ANCHOR LOCATION
STRAP SPACIN
(SEE DETAIL Cr— r w§-
0)
CONTINUOUS
SS STRAP
1/2" PLASTIC COATED 316
STAINLESS STELL STRAPPING
.048" THICK, 670 LB BREAK
STRENGTH —x
TRUSSES OR
1/2" PLASTIC COATED 316
STAINLESS STELL STRAPPING
.048" THICK, 670 LB BREAK
STRENGTH
TRUSSES OR
1. THE STRUCTURAL SYSTEMS DEPICTED HEREIN THESE
DRAWINGS WERE DESIGNED IN ACCORDANCE WITH
THE FLORIDA BUILDING CODE 6TH EDITION (2017) AND
ASCE 7-10 "MINIMUM DESIGN LOADS FOR BUILDINGS
AND OTHER STRUCTURES".
2. WIND SPEED IS 170 MPH ULTIMATE VELOCITY (132 MPH
NOMINAL WIND SPEED) RISK CATEGORY II STRUCTURES.
3. WIND EXPOSURE CATEGORY = C & D (SEE NOTE #7)
4. ROOF ANGLE: 0° TO 45'
5. HEIGHT OF STRUCTURE < 60 FT.
6. MEAN ROOF HEIGHT (MRH): UP TO 30'
7. SS STRAP SPACING FOR WIND EXPOSURE C IS 36" OC
FOR ZONE 1, 24" OC FOR ZONE 2 , 16" OC FOR ZONE 3
FOR MPH UP TO 15'. SS STRAP SPACING FOR WIND
EXPOSURE D IS 30" OC FOR ZONE 1, 20" OC FOR ZONE 2,
12" OC FOR ZONE 3 FOR MPH UP TO 15'. FOR EACH 5 FT.
INCREASE IN MPH UP TO 30'- DECREASE STRAP
SPACING BY 1".
8. NO USE IN PRESSURE ZONE 3 IN HVHZ
SCALE=
DETAIL B
SCALE= N.T.5.
n VN \
DETAIL C
6CALE= N.T,S.
;ot . ,
N.T.S.
OEM PVC ANCHOR
E$>;a
BUTTON OR 16 GA. 7/8" X
1/2" SS ANGLE (1 118"
s
N0.14 x 3" MIN SS HEX LONG) SLOTTED LEG FOR"
WASHER HEAD OR SHEET STRAP INSTALLATION
METAL SCREW PER (TYP.) 50" CTC MAX,
11:j s
9lll
ANCHOR LOCATION
%Wfi ,
ROOFING (EXISTING)
MINIMUM 1/2" O.S.B. OR 1/2" CDX
PLYWOOD SHEATHING (DESIGN OF
y SHEATHING BY OTHERS)
ANCHORING SCREWS SHALL HAVE
EMBEDMENT IN TRUSS OR RAFTER
MAX. 50" CTC MAX. ALONG STRAP
NO. 14x3"MIN SS HEX
WASHER HEAD OR SHEET
METAL SCREW PER ANGLE OR
PVC BUTTON ANCHOR LOCATION
ROOFING (EXISTING)
MINIMUM 1/2" O.S.B. OR 1/2" CDX
PLYWOOD SHEATHING (DESIGN OF
SHEATHING BY OTHERS)
ANCHORING SCREWS SHALL HAVE
EMBEDMENT IN TRUSS OR RAFTER
MAX. 50" CTC MAX. ALONG STRAP
^ NOT VALID WITHOUT THE BLUE INK SIGNATURE
D AND THE ORIGINAL SEAL OF A FLORIDA LICENSED
® ENGINEER. PULLED REQUIRES A
MAALEQt I�I {�Ap R P:P THIS PLAN.
MAY .��Of B � 1�6R P N FILE.
` •.••
W -
'� Q
•'sMIr�P��l oaf,•
K.
W clo,
¢
a M�
Su§m
2 QUN
fA r = C
Z w 0-
�.
o�
O
O On
St
a
0
I—
Oui
I-.
�a
a=
00
oa
P It
JO
a �
Z
ED
County
INSTALL A 3/80 S.S. MACHINE
SCREW THROUGH TUBE INTO
TOP OF S-5 CLAMP 1
1' SQ. X 1/8- ALUM. TUBE
from —TA)
NOTES:
1. CONTRACTOR IS ENCOURAGED TO INSTALL SYSTEM IN PRESSURE ZONE 1.
IF PART OF SYSTEM MUST ENCROACH INTO PRESSURE ZONE 2 OR 3,
CV
'S-5' ALUM. CLAMP 2.
(6061-T6)
2" 1 1/2"
_ INSTALL A MIN. OF (2) 3
3/8- BULLET NOSE STAINLESS
STEEL SET SCREWS TO STANDING
STANDING SEAM METAL ROOF CONNECTION ASSEMBLY
SCALE- N.T.S. 4.
NOTE: FOR 11EDOWN ANCHORAGE OF SOLAR PANELS TO METAL ROOF, STRAPPING ASSEMBLIES 5'
DETAILED ON PAGE S-1 SHALL BE ANCHORED TO ASSEMBLY DETAILED ABOVE FOR CONNECTION TO
STANDING SEAM METAL ROOFS. SCREWS SHALL BE #14 X 1' MIN. SS HEX WASHER HEAD OR SS SELF
TAPPING SHEET MEAL SCREWS.
ASSEMBLY ANCHORAGE: INSTALL 1- SO. X 1/8" SQUARE ALUM, TUBING TRACKS FOR SOLAR PANEL
ANCHORAGE OVER "S-5" ALUMINUM CLAMP (6061-T6 ALLOY) AS MANUFACTURED BY 'DYNAMIC
FASTENER-) OVER STANDING SEAM OF ROOF PANELS. CLAMP SPACING TO MATCH STRAP SPACING (w
CTC FROM PANEL EDGE TO PANEL EDGE, AND AS SPECIFIED ON PAGE S-1 FOR MAX. SPACING
n Anx, I el TA nlul AC C6\RI\
LEGEND
O! VACUUM RELIEF
® THERMOMETER
3® SENSOR
04 BALL VALVE
05 CHECK VALVE
06 3—WAY VALVE
7® WATER SENSOR
OS FILTER
09 PUMP
10K AUXILLARY HEATER
file AUTOMATIC CONTROL
r OPTIMAL COMPONENTS
OM POOL
GENERAL NOTEI x COMPONENTS ARE OPTIONAL
TWIP. MLWBMD SCHBMMC
SCAT ILT.s
NOTES:
1. PLUMBING SHALL BE INSTALLED AS PER DETAIL AND ALL REQUIREMENTS OF THE
6th ED. FLORIDA PLUMBING CODE (2017). SPECIAL CARE SHALL BE TAKEN REGARDING
PIPE SUPPORT, PER FPC TABLE 308.5. THE ABS VALUE OF 4 FT. SHALL BE TAKEN
AS THE MAXIMUM FOR HORIZONTAL AND 10 FT. FOR VERTICAL SOLAR PIPING. PER
6th ED. FLORIDA MECHANICAL CODE, CONTRACTOR SHALL INSTALL MANUAL DRAIN
DOWN VALVES AND INSTRUCT OWNER IN DRAINING AND RE -STARTING THIS SOLAR
POOL HEATING SYSTEM. OWNER SHALL BE INFORMED THAT FREEZE PROTECTION IS IP
TO OWNER. IF SOLAR POOL HEATER FREEZES, IT IS THE OWNER'S SOLE RESONSIBIUTY.
FREEZE DAMAGE RESULTS FROM AN ERROR IN OPERATION. COLLECTORS SHOULD
ALWAYS BE DRAINED BY OWNER OR OWNER'S REPRESENTATIVE IN ADVANCE OF NEAR
FREEZING WEATHER.
r11YVl 1%11 %1 IV w J, I/" ,- —_ . • -- . •— - -- -
CONTRACTOR SHALL ATTACH COLLECTOR ARRAY WITH OEM HARDWARE
AND STRAPPING. CONTRACTOR MUST BE CAREFUL TO "CENTER" ANCHORS
SO SCREWS ARE INSTALLED INTO THE CENTER OF THE TRUSS TOP CHORD
OR RAFTER BELOW. AN APPROVED ALTERNATIVE WOULD BE CONTRACTOR
INSTALLED NOMINAL 2'X4' SOUTHERN PINE ##2 BLOCKING BETWEEN
TRUSSES OR RAFTERS AT SCREW LOCATION, CENTERED ON SCREW.
BLOCKING SHALL BE CONNECTED TO TRUSS OR RAFTER WITH SIMPSON
A34 OR A23 ON EACH FACE OF BLOCKING (2 CONNECTORS PER
CONNECTION-TO--TRUSS-OR-RAF-TER). - --
CONTRACTOR SHALL ADHERE TO REQUIREMENT OF FBC CHAPTER 15
(ROOFING) AND BEST PRACTICES OF NRCA ROOFING & WATERPROOFING
MANUAL TO ENSURE THE SOLAR INSTALLATION DOES NOT CAUSE ROOF
LEAKS AT INITIAL INSTALLATION OR AS THE SYSTEM "AGES".
AS LONG AS CONNECTOR SPACING AND NUMBERS ARE NOT REDCUED THE
CONTRACTOR MAY USE A SUBSTRATE OR ALUMINUM MOUNTING FRAME,
"SANDWICHED" BETWEEN THE COLLECTOR AND ROOF ON FLUSH MOUNT
INSTALLATIONS ONLY.
OEM STRONGLY RECOMMENDS AGAINST CLAMPS ON THE BOTTOM HEADER.
SOLAR UNITS INSTALLED PER THIS PLAN SHALL NOT FORM PART OF THE
BUILDING ENVELOPE (I.E. WINDOW. DOOR). SOLAR UNITS SHALL BE
MOUNTED ABOVE ROOF SURFACE LIKE A A/C CONDENSER THEREFORE
THE
Flat a f
Hip Roof (70< 8 5 27°)
Gable Roof (B s 70) Gable Roof (70< 0 S 45°1
Interior Zones ® End Zones . Comer Zones
Hab•7e°e1Nbb•laa4 node. lam MO..lae8 xzle•lane7
PRESSURE ZONE NOTES
NTS
IN T— HE L07CDS C�N`TFiE ROOF FRAMING FOR A PARALLEL MOUNT AND PRESSURE 7 E NOTES
MODEST CHANGES IF TILT UP. HOWEVER THE INTERNAL AND EXTERNAL a. 10 PERCENT OF THE LEAST HORIZONTAL DIMENSION OR .4h,
COMPONENTS OF WIND PRESSURE DECOUPLE, E.G. THE ROOF RESISTS THE,.
HE ' WHICHEVER IS LESS, BUT NOT LESS THAN EITHER 4% OF LEAST
INTERNAL WIND PRESSURES AND THE SOLAR UNITS RESIST THE EXTERNAL HORIZONTAL DIMENSION OR 3 FT.
WIND PRESSURES. THE EXTERNAL WIND FORCES ARE THEN h: MEAN ROOF HEIGHT, IN FEET. EXCEPT THAT EAVE HEIGHT SHALL
TRANSFERRED TO THE ROOF FRAMING THROUGH THE SOLAR ATTACHMENT BE USED FOR ROOF ANGLES < THAN 10 DEGREES.
HARDWARE. 0: ANGLE OF PLANE OF ROOF FROM HORIZONTAL, IN DEGREES.
5. SOLAR POOL HEATING COLLECTORS ARE REQUIRED TO BE TESTED,
CERTIFIED AND LISTED BY THE FLORIDA SOLAR ENERGY CENTER.
CONTRACTOR SHALL PROVIDE DOCUMENTATION TO OWNER OF THEIR
LISTING AND RATINGS.
1" DIA SS
FENDER WASHER
PROVIDE 1/4" STAINLESS STEEL TAPCON SCREWS
OF ADEQUATE LENGTH TO SECURE BRACKET TO
CEMENT TILE DRILL HOLE THRU CONC. TILE ONLY
(NOT INTO ROOF MEMBRANE) AND INSTALL TAPCON \ \
SO AS NOT TO BREAK TILES.
NOTE:
APPLY ADHESIVE TO THE INTERFACE OF THE SOLAR WORLD MOUNTING
BRACKET AND PVC BUTTON ANCHORS BEING ATTACHED TO THE \
CONCRETE FLAT TILE OR BARREL TILE. CONTRACTOR SHALL ALSO APPLY
ANCHORING EPDXY TO TAP CON SHAFT PRIOR TO INSTALLING TAP CON.
TAP CON TO BE INSTALLED PRIOR TO EPDXY SETTING. A 3"X1"X1/8"
ALUMINUM (ALLOY: 6061-T6) ANGLE MAY BE USED TO MOUNT PANELS TO
TILE AS A CONTRACTORS OPTION. APPROVED ANCHORING EPDXIES ARE
CHEMLINK "MA", SUREBOND "SB-190" OR APPROVED EQUAL.
INTERMEDIATE BUTTON ANCHORS TO BE PROVIDED FOR SS STRAPPING
AS DETAILED ON PAGE S-1. SPACING OF BUTTON ANCHORS ARE 48" OC
ALONG THE SS STRAPING. SPACING OF STRAPING IS 27" OC (EXP. C) & 24'
OC (EXP. D) FOR PRESSURE ZONE 1 AND 16" OC (EXP. C) & 12" OC (EXP. D)
FOR PRESSURE ZONE #2. PANELS ON TILE SHALL NOT BE INSTALLED IN
PRESSURE ZONE 3. ADJUST STRAPPING SPACING FOR MEAN ROOF
HEIGHT OF STRUCTURE FROM 15 FT. TO 30 FT. AS SPECIFIED
�� ON PG. SS-1.
BUTTON ANCHORS TO BE INSTALLED IN CENTER AOR CROWN OFTILE.
S1TI�P BRACKET TILE ROOF �
SCALE= N.T.S.
COLLECTOR HEADER 2.00" I.D.
5132" WALL THICKNESS
COLLECTOR TUBES
0.220 I.D. WITH
0.030 WALL
CONC. BARREUFLAT TILE
MINIMUM 1/2" O.S.B. OR
PLYWOOD SHEATHING
��Rq /FTER
unx�ve`[1n i'> [Y2 1{rT+k/B/ OE INK SII
-� -- -
EQUIR A SE RIGINAL APER COPY
.�. THIS.' P BE 0;%FAIR PLANS
wAtj�.j
/IIIIIIII
la
d
FAI
LU °cu,° uj
rn
_ -'¢rn
m
¢UN
CA Ern
Z NOL
-
Q CoT
O
F-
�N
J
W
fA a
OD
ZO