Loading...
HomeMy WebLinkAboutENERGY EEFFICIENCY CODE - 6-12-97Department of Community Affairs SN: 7258 r FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION FORM 60OA-93 Residential Whole Building Performance Method A CENTRAL PROJECT NAME: Gibilisco #2 BUILDER: Pat Gibilisco Paso,uQl2. rAND ADDRESS: PERMITTING CLIMATE Ft. Pierce, FL OFFICE: St. Lucie Co ZONE: 41_1 51_1 61_1 OWNER: PERMIT NO. JURISDICTION NO. �J. CK 1.. New construction or addition 1. New Construction 2. Single' family detached or Multifamily attached 2. Single -Family 3'. If Multifamily -No. of units 3. 0 4 If Multifamily, is this a worst case (yes/no) 4. SCANNED- 5. Conditioned floor area (sq.ft.) 5. 1432.40 BY 6 . -'Predominant eave overhang (ft.) 6. 2.00 St Lucie cou 7. 'Rorch overhang length (ft.) 7. 12.00 - 8. glass area and type: Single Pane Double Pane a. Clear Glass 8a.170.Osgft O.00sgft b. Tint, film or solar screen 8b. O.Osgft. O.00sgft 9_ Floor type and insulation; a. Slab on grade (R-value, perimeter) 9a.R= 0.00 , 178.00 ft 10.Net Wall type area and insulation: 4. Exterior: 2. Wood frame (Insulation R-value) 10a-2 =11.00 937.00sqFFVIEWEC b. Adjacent: 2. Wood frame (Insulation R-value) 10b-2 R= 1.00, 267.00sq11.Ceiling type area and insulation: a. Under attic (Insulation R-value) 1 a.R=19.00 , 1433.00sq 12.Air distribution systems DATE_ a. Ducts (Insulation + Location) 12a. R= 6.00 uncond API. 13.Cooling system 13. Type: Central AU 14.Heating System: 15.Hot water system: 16.Hot Water Credits: (HR-Heat Recovery, DHP-Dedicated Heat Pump) 17.Infiltration practice: 1, 2 or 3 18.HVAC Credits (CF-Ceiling Fan, CV -Cross vent, HF-Whole house fan, RB-Attic radiant barrier, MZ-Multizone) 19:EPI (must not exceed 100 points) a. Total As -Built points b. Total Base points S- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - I Hereby certify that the plans and specifications covered by this calcu- lation are in compliance with the Florida Enerav Code. /% _ I hereby certify that this building is in compliance with the Florida Energy Code: R : 10 14. Type: S rip Heat .9;•y:,,.;,,;.x COP: 1.00 15. Type: Electric ' 0.97 16 17. 2 18.(/TCV 19. 97.26 19a. 28870.76 19b. 29684.04 BY_ ---------------------------------------- Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed"' this building will be inspected for compliance in accordance with Section 553.908 F.S. OWNER/AGENT: BUILDING OFFICIAL: DATE: . I I -DATE: BE i SUMMER CALCULATIONS ******************************************************************************* --- BASE ___ __= AS -BUILT -=------ ---------------------------------------------------------------------- ------------------------------------------------------------------------------- GLASS--------------- I ORIEN AREA x BSPM = POINTS TYPE SC ORIEN AREA x SPM x SOF = POINTS N 22.00 82.2 1808.4 SGL CLR N 9.0 51.0 .80 367.6 SGL CLR N 4.0 51.0 .70 142.6 SGL CLR N 9.0 51.0 .80 367.6 E 54.00 82.2 4438.8 SGL CLR E 18.0 109.2 .72 1418.8 SGL CLR E 36.0 109.2 .72 2837.6 S18.00 82.2 1479.6 SGL CLR S 18.0 100.2 .60 1077.2 W ,= 76.00 82.2 6247.2 SGL CLR W 4.0 109.2 .54 235.2 SGL CLR W 13.0 109.2 .65 916.3 SGL CLR W 42.0 109.2 .35 1612.9 .- SGL CLR W 17.0 109.2 .72 1340.0 ---------F----------------------_------------------_--------------------------- .15 x COND. FLOOR / TOTAL GLASS ADJ. x GLASS ADJ GLASS GLASS AREA AREA FACTOR POINTS POINTS I POINTS ---------- ----------------------------------------------------------------------- .15 1,432.40 170.00 1.264 13,974.00 17,661.49 10,315.89 NON GLASSIr----------- WALLS ---- Ext 937 Adj 267 x BSPM = POINTS I TYPE R-VALUE AREA x SPM = POINTS --------------------------------------------------------------------- 0 1.0 937.0 0 .7 186.9 DOORS----'------------ Ext 2110 4.8 100.8 Adj 21 [ 0 1.6 33.6 Ext Wood Frame 11.0 937.0 1.90 1780.3 Adj Wood Frame 11.0 267.0 .70 186.9 Ext Wood 21.0 7.20 151.2 Adj Wood 21.0 2.40 50.4 CEILINGS ------------- UA 1432�0 .6 859.2 Under Attic 19.0 1433.0 1.10 1576.3 Fl�ORS---�----------- Slb 17810 -31.8-5660.4 Slab -on -Grade .0 178.0 -31.90 -5678.2 TN&ILTRATION--------- u 143214 10.9 15613.2 Practice #2 1432.4 10.90 15613.2 ------------------------------------------------------------------------------- TOTAL SUMMER POINTS 29,731.75 I 23,995.95 --------- TOTAL x ------------------------------------ SYSTEM = COOLING TOTAL x CAP x DUCT x SYSTEM x CREDIT = COOLING SUM PT, MULT POINTS I COMPON RATIO MULT MULT MULT POINTS ---------=-------------------------------=------------------------------------- 29,731.75 .37 11,000.75 1 23,995.95 1.00 1.070 .340 .860 7,507.57 9 d WINTER CALCULATIONS ******************************************************************************* BASE ___ __= AS -BUILT GLASS ---- ------------ ORIEN AREA x BWPM = POINTS TYPE SC ORIEN AREA x WPM x WOF = POINTS ------------------------------------------------------------------------------- N 22.00 -3.4 -74.8 SGL CLR N 9.0 9.6 1.12 96.9 SGL CLR N 4.0 9.6 1.19 45.8 SGL CLR N 9.0 9.6 1.12 96.9 E 54.00 -3.4 -183.6 SGL CLR E 18.0 -2.2 -.53 20.9 SGL CLR E 36.0 -2.2 -.53 41.8 S 18.00 -3.4 -61.2 SGL CLR S 18.0 -10.9 .58 -114.5 W 76.�00 -3.4 -258.4 SGL CLR W 4.0 -2.2 -1.86 16.4 SGL CLR W 13.0 -2.2 -1.01 29.0 �o SGL CLR W 42.0 -2.2 -3.81 351.8 - SGL CLR W 17.0 -2.2 -.53 19.7 --------- .15 ----------------------- x COND. FLOOR / TOTAL GLASS -------------------_--------------------------- ADJ. x GLASS ADJ GLASS GLASS AREA AREA FACTOR POINTS POINTS I POINTS --_------I---------------------------------------------------------------------- .15 ------------------------------------------------------------------------------- 1,432.40 170.00 1.264 -578.00 -730.52 604.70 ------------------------------------------------------------------------------- NON GLASS I L ----------- AREA x BWPM = POINTS I TYPE R-VALUE AREA x WPM = POINTS --------- WALLS----I ---------------------------------------------------------------------- ----------- Ext 937.0 1.1 1030.7 Ext Wood Frame 11.0 937.0 2.00 1874.0 Adj 267.0 1.8 480.6 Adj Wood Frame 11.0 267.0 1.80 480.6 DOORS---- ------------ Ext 2110 ..0 5.1 107.1 Ext Wood 21.0 7.60 159.6 Adj 21� 4.0 84.0 Adj Wood 21.0 5.90 123.9 CEILINGS" ----------- UA 1432 � 0 .6 FLOORS--- Sl� 178 IN'j'ILTRAT 1432 TOTAL WIN TOTAL x WIN PTS 7,365.7,- A 859.2 0 -1.9 -338.2 Under Attic 19.0 1433.0 1.00 1433.0 Slab -on -Grade .0 178.0 2.50 445.0 WN--------- 4 4.1 5872.8 Practice #2 1432.4 4.10 5872.8 --------------------------------------------------------------------- ---------------------------------------------- ----- -- ER POINTS 7,365.72 10,993.64 --------------------------------------------------------------------- ----------------------------------------------------------------- --- SYSTEM = HEATING TOTAL x CAP x DUCT x SYSTEM x CREDIT = HEATING MULT POINTS COMPON RATIO MULT MULT MULT POINTS 1.10 8,102.29 1 10,993.64 1.00 1.070 1.000 1.000 11,763.19 ------------------------------------------------------------------- WATER HEATING ******************************************************************************* BASE ___ __= AS -BUILT -------------------------------- -------------- - NUM OF x MULT TOTAL TANK VOLUME EF TANK x MULT x CREDIT = TOTAL BEDRMS RATIO MULT ----------------------------------------------------------------------------- 3 3527.0 10,581.00 30 .97 1.000 3200.0 1.00 9,600.00 SUMMARY BASE ___ __= AS -BUILT ----------------------------------------------------------------- COOLING HEATING HOT WATER TOTAL I COOLING HEATING HOT WATER TOTAL POINTS + POINTS + POINTS = POINTS POINTS + POINTS + POINTS = POINTS 11000.7 8102.3 10581.0 29,684.04 7507.6 '11763.2 9600.0 28,870.76 ***************** * EPI = 97.26 ***************** ENERGY GUIDE For detained information of the EP2 rating number or for any ITEM listed, ask your Builder for DCA Form 600A-93 or Form 61OOB-93 The ITEM WINDOWS..) INStJLATIO1 Ceiling Wall Floor EPI= 97.3 O 10 20 30 40 50 60 70 8 --------------------------------------X--I allowable EPI is 100. The lower the EPI the more efficient the home RESIDENTIAL ENERGY PERFORMANCE RATING SHEET HOME VALUE Low Efficiency High Efficiency SINGL CLR DBL TINT .................Single Clear IX -------------------- I r . . . . . . . . . . . . . . . . . . R-Value......... 19.0 R-Value......... 11.0 R-Value......... 0.0 AIR CONDITIONER ............. SEER... I .................. 10.0 HEATING SYSTEM .............. Electric COP ............. 1.0 WATER HEATER ................ Electric EF.............. 0.97 ;has EF.............. 0.00 Solar EF.............. OTHER FEATURES .............. R-10 R-30 1--------- X----------- I R-0 R-7 --------------------X1 R-0 R-19 IX-------------------- I 10.0 SEER 17.0 IX-------------------- I 2.50 COP 4.19 IX-------------------- I 0.88 0.96 1-------------------- X1 0.54 0.90 1--------------------- 1 0.40 0.80 1--------------------- I I certify 'hat these -energy saving features required for the Florida Energy Code have been installed in this house. Builder Address: Signature: Date: City/Zip Florida Florida Code for Building Construction - 1993 ment of Community Affairs FL-EPL CARD93