ICE OF ACCEPTANCE(NOA)
l Doors Inc.
:kmore Street
Laurent, Quebec, Canada 114T1K6
IRI
ED
MUM-DADE COUNTY
P ODUCT CONTROL SECTION
N12019 11805 SW 26Street, Room 208
i(RER) Miami, Florida 33175-2474
ST. Luci, Permlttl 86) 315-2590 F (786) 315-2599
BY
St Lucie County
DA isbeing issued under the applicable rules and regulations governing the use of construction materials. The
;ntation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to
. in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
:)A shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
uni Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this
: or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
i the use of such product or material within their jurisdiction. RER reserves the right to revoke this
nce; if it is determined by Miami -Dade County Product Control Section that this product or material fails to
e requirements of the applicable building code.
duct is approved as described herein, and has been designed to comply with the Florida Building Code,
ig the High Velocity Hurricane Zone.
Series "GenStorm" Flush Single Outswing Steel Doors
APPROVAL; DOCUMENT: Drawing No. AD10-02, titled "Genstorm Outswing Steel Door System (LMI)", sheet 1
through 7 of 7, dated 02-10-11 and last revised on JAN 02, 2018, prepared by MCY Engineering, Inc., signed and
sealed by Yiping Wang, P.E., bearing the Miami -Dade County Product Control Revision stamp with the Notice of
Acceptance number and expiration date by the Miami -Dade County Product Control Section.
MISSILE IMPACT RATING: Large Missile Impact Resistant
4 1
1. SeelDesign Pressures & corresponding Hardware in sheet 5. Max. Exterior (positive) DP= +65, where water
inf4tration requirement is needed.
Z. Options #1, 2 & #4 require total two (2) flush bolts (top bottom) on active panel.
LABELING: Each unit shall bear one of the following permanent labels:
4IGenstee' Doors Inc. Gensteel Doors Inc. North American Doors Corp.
4950 Hickmore Street 2335 Industrial Park Drive 1471 Military Turnpike
Ville St. Laurent, Quebec, Canada 144T1K6 Cornwall, Ontario, Canada K6H7M4 Plattsburgh, NY 12901-1911
and series and the statement: "Miami -Dade County Product Control Approved".
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERD'IINf ATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration' date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA #15-0825.03 and consists of this page 1 and evidence pages E-1, as well as approval
document mentioned above.
The submjitted documentation was reviewed by Ishaq I. Chanda, P.E.
'+ NOA No.18-0116.17
Expiration Date: July 14, 2020
Approval Date: March 06, 2018
Page 1
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
1. Evidence submitted under previous files
A. DRAWINGS
1. Manufacturer's die drawings and sections (submitted under file listed below)
2. Drawing No. AD10-02, titled "Genstorm Outswing Steel Door System (LM)7", sheet 1 through 7 of 7,
;. dated 02-10-11 and last revised on AUG 21, 2015, prepared by MCY Engineering, Inc., signed and
sealed by Yiping Wang, P.E.
B. TESTS (submitted under files #12-0223.35 /#10-1203.03/#05-0127.11)
1. Test reports on 1) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94
2) Water Resistance Test, per FBC, TAS 202-94 (PMK 2005-AT)
Along with marked -up drawings and installation diagram of Genstorm Opaque Double Swinging
Doors, prepared by Fenestration Testing Laboratory, Inc., Test Report No. FTL 6346, dated
10/14/10, signed and sealed by Jorge A. Causo, P.E.
2. Test reports on 1) Air Infiltration Test, per FBC, TAS 202-94
2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94
3) Water Resistance Test, per FBC, TAS 202-94(PMK177T threshold)
4) Large Missile Impact Test per FBC, TAS 201-94
j 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94
6) Forced Entry Test, per FBC 2411 3.2.1 and TAS 202-94
7) Tensile test per FBC, TAS 202
Along with marked -up drawings and installation diagram of Genstorm Opaque, Glazed and
Louvered Single and Double Swinging Doors, prepared by Fenestration Testing Laboratory, Inc.,
Test Report No. FTL 5877, dated 10/13/09 and FTL 5898, dated 09/14/09, both signed and sealed
by Julio E. Gonzalez, P.E. (transferred from file # 10-0125.01)
3. Additional Test reports per FBC TAS 201, 202 and 203-94, test report No. ITS-3058370-
' DOUBLE, dated 12/09/04 for Double Outswing Honeycomb Steel Door System, prepared by
Intertek Testing Services, signed and sealed by Stephen J. Emerman, P. E. (# 05-0127.11).
1. C. CALCULATIONS
1. Anchor verification calculations and structural analysis, complying with FBC-2014(5th Edition),
prepared by MCY Engineering, Inc, dated 08/21/15, signed and sealed by Yiping Wang, P.E.
D. QUALITY ASSURANCE
1. Miami Dade Department of Regulatory and Economic Resources (RER).
E. MATERIAL CERTIFICATIONS
1. Tensile Test, per ASTM A370-05 item B (1) (7)
2. Tensile test report NO. FTL 5877 per ASTM A370-05 dated 10/13/09, issued by Fenestration
Testing Lab, signed and sealed by Julio Gonzales, P.E. (submitted under file # 10-1203.02).
F. STATEMENTS
1. Statement letter of conformance to FBC 2014 (5th Edition), dated 08/20/15, prepared by MCY
Engineering, Inc, signed and sealed by Yiping Wang, P.E.
2. Statement letter of Lab. Compliance, as a part of above test reports.
G. OTHER
This NOA revises & renews # 12-0223.35, expired on 07/14/15.
Test proposal No. 08-1489, issued to Genteel Door Inc, approved on 11/14/08.
Distribution agreement between GenSteel Door, Canada & North American Door Cm
N.Y.
dated 10/22/10, signed by Bruno Gervasi and Antonio Gervasi, respectively4
Ishaq I. C anda, P.E.
Product Control Examiner
NOA No. 18-0116.17
Expiration Date: July 14, 2020
Approval Date: March 06, 2018
E-1
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
2. New Evidence submitted
A. DRAWINGS
1. Drawing No. AD10-02, titled "Genstorm Outswing Steel Door System (LMI)", sheet 1 through
.7 of 7, dated 02-10-11 and last revised on JAN 02, 2018, prepared by MCY Engineering, Inc.,
signed and sealed by Yiping Wang, P.E.
B. Test
1. None.
C. CALCULATIONS
1. None.
D. QUALITY ASSURANCE
1. Miami Dade Department of Regulatory and Economic Resources (RER).
E. MATERIAL CERTIFICATIONS
1. None.
F. STATEMENTS
1. Statement letter of conformance to FBC 2017 (6th Edition), dated 01/02/18 , prepared by MCY
Engineering, Inc., signed and sealed by Yiping Wang, P.E.
-G. OTHER
:.r
1. This NOA revises # 15-0825.03, expiring 07/14/21.
Ishaq L Chanda, P.E.
Product Control Examiner
NOA No. 18-0116.17
Expiration Date: July 14, 2020
Approval Date: March 06, 2018
E-2