HomeMy WebLinkAboutRESIDENTIAL HVAC LOADS - 1-14-19Express 1828 Cali Left St Lucie 2019 i HVAC Load Calculations for Express Homes SCANNED LOcie Coup ty �=atr Prepared By: Kristin Kelly Florida Breeze 6928 Vickie Circle West Melbourne 3219518767 Monday, January 14, 2019 Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. Riivac sidiiiiJal a -e , -evejo �,Anc. 1 ,tt fpjaqg� �afi L S , t e2 VIN It Role'b"t'Roport e Re '2�:cfl Project Title: Exp ress 1828 Cali Left St Lucie 2019 I Designed By: Kristin Kelly Project Date: Friday, January 11, 2019 Client Name: Express Homes Company Name: Florida Breeze Company Representative:, Kristin Kelly CompanAddress: 6928 Vickie Circle Company City: West Melbourne Company Phone: 3219518767 Referenc6 City: -St Lucie" ' Florida Building Orientation: Front door faces South' Daily Tem, perature Rangq:, ..Medium Latitude: 1 27 Degrees Elevationi 25 ft. Altitude F I actor- 0.999 Outdoor Outdoor Outdoor Indoor Indoor Grains DrV Bulb Wet Bulb Rel, Hum Rel.Hum Dry Bulb Difference Winter: 42 39.4 n/a n/a 70 n/a Summer: 95 78 47% 50% 75 53 TLPR-14- As Total Building Supply CFM: 988 CFM Per Square ft.: 0.541 Square ft. lof Room Area: 1,828 Square ft, Per Ton: 689 Volume (ftr): 15,721 - ld'WON Total Heating Required Including Ventilation Air: 29,568 Btuh 29.568 MBH Total Sens I ible Gain: 26,355 Btuh 83 % Total Late ,t Gain: 5,478 Btuh 17 % Total Cooling Required Including Ventilation Air: 31,833 Btuh 2.65 Tons (Based On Sensible + Latent) Rhvac is anACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to 'select a unit that meets both sensible and latent loads according to the manufacturers performance data at your desig 11 conditions. C:\ ... \Express 1828 Cali Left St Lucie 2019.rh9 Monday, January 14, 2019, 3:45 PM Florida Breeze -' W�stMslboume .F�! 32904 Miscellanieous F ,Ibpment St Lucie 2019.' Page 3 f winter:1 42 39.4 80% n/a 70 Summer: 95 78 47% 50% 75 u Si"z't; uts Main Trunk Runouts Calculatg: Yes Yes Use Schedule: Yes Yes Roughness Factor: Pressure Drop: 0.01000 0..1000 in.wg./100 0.01000 Minimum Velocity: ft,. 550 ft./min 0.1000 in.wg.1100 ft, 450 ft./min Maximum. Velocity: 600 ft./min 750 ft./min Minimum' Height: Maximum Height: 0 in. 0 in. 0 in.. _ 0 in. Lqulsy� Da a Winter Summer Infiltration, Specified: 0.380 AC/hr 0.200 AC/hr 100 CFM 52 CFM. Infiltration Actual: Above Grade Volume: 0.380 AC/hr 0.200 AC/hr X 15,721 Cu'.'. X 15,721 Cu.ft. 5,974 Cu.ft./hr 3,144 Cu.ft./hr Total Building Infiltration: X 0.0167 100 CFM X 0.0167 52 CFM Total Building Ventilation: 0 CFM 0 CFM ---Syste 1--- Infiltration& Ventilation Sensible Gain Multiplier: 21.98 = (1.10 X 0.999 X 20.00 Summer Temp, Difference) Infiltrations& Ventilation Latent Gain Multiplier: 35.94 = (0.68 X 0.999 X 52.90 Grains Difference) Infiltration I& Ventilation Sensible Loss Multiplier: 30.77 = (1.10 X 0.099 X 28.00 Winter Temp. Difference) Winter Infiiltration Specified: Summer Infiltration Specified: 0.380 AC/hr (100 CFM), Construction: Average 0.200 AC/hr (52 CFM), Construction: Average 52.90 1 SuPpIY Attie 166 0:12 8 554 No i 1 RetuCn Attic 16B 0.12 8 474 No 1 1 f I } C:\ ...\Express 1828 Cali Left St Lucie 2019.rh9 Monday, January 14, 2019, 3:45 PM Rhvac ReFsrdenh d & Light Commei'ciai HUAC toads Et' a Software Developme t, InC Flattda, Breeze � • p ss 182 G` l.e SE i�20 t�9 �:.West�IVteiboirr'inie FL.:32904 Pa Duct Sr e Preview. J _SP _ 4 �Room or DuctName Minimum tvla?cmum Vebcty VebGty Ra igh. Factor Design Li100 Loss •L1tx t Vebciy Duct t engfh 'Htg Clg Act Ouct Flow Flow Flow Sim Si+stem 1 SupplyRunouts Zone 1 1-1Nhole HLe BUIWn 450 750 0.01 0.1 55a3 367 988 9-6 i OtherDucts n System 1 SuBP1YMai Trunk : Buift-In 550 600 0.01 0.11 559.3• 367 M. 18 _-.._._._ Summery. System 1 Heating Flow. 367 Cooling Flow: 988 CA r i Monday, January 14, 2019, 3:45 PM I West Met boutrie, FL-3290G Systern`1: Sum. unary,:Loa 2A-v-o: Glazing -Double pane low-e (e = 0.60), operable windouv, vinyl frame, U-value 0.35, SHGC 0.29 2A-v-d: Glazing -Double pane low a (e = 0.60), sliding glass door, vinyl frame, U-value 0.61, SHGC 0.34 2B-v-o: Glazing -Double pane low-e (e = 0.60), fixed sash, vinyl frame, U-value 0.35, SHGC 0.29 11J: Door -Metal - Fiberglass Core, U-value 0.6 11 D: Door -Wood - Solid Core, U-value 0.39 13AB-Ofcs1 Wall -Block, no blanket or board insulation, filled core, siding finish; U-value 0.183 12C-Osw: Wall -Frame, R-131nsulation in 2 x 4 stud ' cavity,lno board insulation, siding finish, wood studs, U-value 0.091 166-30: Roof/Ceiling-UnderAttle with Insulation on Attic Floor (also use for Knee Walls and Partition Ceilings), Vented Attic;'No Radiant Barrier, Dark' Asphalt Shingles or Dark Metal, Tar and Gravel or Membrane, R-30 insulation, U-value 0.032 22A-pm: Floor -Slab on grade, No edge insulation, no: insulation below floor, any floor cover, passive, heavy dry or light wet soil, U-value 1.18 Subtotals for structure: People: Equipmen Lighting: Ductwork: Infiltration: lWinter CFM: 100, Summer CFM: 52 Ventilation; Winter CFM: 0, Summer CFM: 0 System 1 Load Totals: 124.8 1,224 0 2,312 40.8 697 0 790 2.5 24 0 33 20.4 343 0 379 19 208 0 230 1237.1 6,340 0 5,072 317.1 808 0 765 1828 1,638 200 6,608 17,890 5 0 8,614 3,064 0 29,568 0 3,217 0 0 0 1,000 500 2,095 1,883 0 5,478 12,798 1,150 2,100 0 9,155 1,152 0 26,355 790 33 i 379 230 5,072 765 3,217 h 12,798 2,150 2,600 0 11,250 ` 3,035 0 31,833 ouppty 4t-lyc 988 CFM Per Square ft..: 0.541 Square ft. of Room Area: 1,828 Square ft. Per Ton: ggg Volume (fe : 15,721 nSystem �� ` s Total HeatirlTg Required Including Ventilation Air: 29,568 Btuh-29.568 MBH Total Sensible Gain: 26,355 Btuh 83 % Total Latent Gain: 5,478 Btuh 17 % Total Cooling Required Including Ventilation Air: 31,833 Btuh 2.65 Tons (Based On Sensible + Latent) ' mN Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. { I I C:1... IExpresj 1828 Cali Left St Lucie 2019.rh9 Monday, January 14, 2019, 3:45 PM I R( vac Residential &fUghf C�oriimercial l~lite o. 'are De elopmenk;.tnc. Florida Breeze` Bxpre s 9828 Cali LefESt Lucfe`2Q19 `. West,Wbburhe FL 32904 � Page6 Equipment Data_- S,�stem Cooling System Type: Air Source Heat Pump Outdoor Model: Indoor Model: R4H436(A,G)KCk Tradename: FXM4X36•"AL 14 SEER R SERIES R410A HP Outdoor Manufacturer: COMFORTMAKER Description: Air Source Heat Pump AHRI Reference No.: Capacity: 10142182 34,327 Efficiency: 15 Sl ER Heating System Type: Air Source Heat Pump Model: Tra R4H436(A,G)KC* ename: 14 SEER R SERIES R410A HP Manufacturer. Description: COMFORTMAKER Air Source Capacity: Heat Pump 33,800 Efficiency: 8.5 HSPF This system's equipment was selected in accordance with ACCA Manual S. Manual S Equipment sizing data: SODS: 95F, SOWB: 78F, WODB: 42F, SIDE: 75F, SIRH: 50%, WIDE: 70F, Sen. gain: 26,365 Bt6h, Let. gain: 5,478 Btuh, Sen. loss: 29,568 Btuh, Entering clg. coil DB: 79.3F, Entering clg. coil WB: 64F, Entering htg. coil DB: 66.7F, Clg. coil TD: 20F, Htg. coil TD: 70F, Req. clg. airflow: 988 CFM, Req. htg.. airflow: 367 CFM C:1... \Express 1828 Cali Left St Lucie 2019.rh9 Monday, January 14, 2019, 3:45 PM i — _ tnc. RSvac -Resident+ai LrghtammerctallH AC�Laaets. Et#r eoftwaret?ev®fanment a Florida Breeze Express 1828 allrLeft St Luc�e.2019 ' i WestMeif,aurne FL 3290 �� , System: f -Room Load :Surr�inar}r . ---Zone 1--- 1 Whole House 1,828 28,240 367 9-6 559 21,722 3,383. 988 988 Duct Latent 454 Return Duct 1,328 " 4,633 1,641 System 1 total 1,828 29,568 367 26,355 5,478 988 988 System 1 Main Trunk Size:. 18 in. . Velocity: 559 ft./min Loss per 00 ft.: 0.046 in.wg t Col3i gste 5U%r e - - - -' Taal Net Requ red: 2.65 83% / 17%° 26,355 5,478 r�1 31,833 Actual; 2.86 82% ! 18% 28.,'198 6,129 I 34,327 , , l HeatingSystem -- - -. - _Cooling System Type: Air Source'.Heat Pump Air Source Heat Pump Model. R4H436(A,G)KC' R4H436(A,G)KC* Indoor Model: FXM4X36**AL Brand.. I 14 SEER R SERIES R410A HP 14 SEER R SERIES R410A HP Descriptioh: Air Source Heat Pump Air Source Heat Pump Efficiency: 8.5 HSPF '15 SEER Sound: 0 0 Capacity: 33,800 Btuh 34,327 Btuh Sensible Capacity: n/a 28,198 Btuh Latent Capacity: n/a 6,129 Btuh AHRI Reference No.: n/a 10142182 This syste I s equipment was selected in accordance with ACCA Manual S. Manual S equipment sizing data: SODB: 95F, SOWS: 78F, WODB: 42F, SIDB: 75F, SIRH: 50%, WIDB: 70F, Sen. gain: 26,355 Btuh, at. gain: 5,478 Btuh, Sen. loss: 29,568 Btuh, Entering clg. coil DB: 79.3F, Entering clg. coil WB: 64F, Entering htg. coil DB: 66.7F, Clg. coil TD: 20F, Htg. coil TD: 70F, Req. clg. airflow: 988 CFM, Req. htg, airflow: 367 CFM I .I I I I C:\ ...\Express 1828 Cali Left St Lucie 2019.rh9 i I 4 i i Monday, January 14, 2019, 3.45 PM Contractor Florida Breeze County, Town, Municipality, Jurisdiction Header Information REQUIRED ATTACHMENTS' Manual A Form (and supporting worksheets): Mechanical License # CAC1814113 or MJ1AE ForM2 (and supporting worksheets): OEM performance data (heating, cooling, blower) Building Plan Manual D Frictioh Rate Worksheet: Duct distribution system sketch: Home Address (Street or Lot#, Block, Subdivision) Winter Design Conditions Outdoor temperature 42 OF Indoor temperature 70 OF Total heat loss 29568 Btu/h Summer Design Conditions Outdoor temperature 95 OF Indoor temperature 75 OF Grains difference 53 A Gr @ 50 % Rh Sensible fieatgain 26355 Btu/h Latent he#t gain 5478 Btu/h Total heat gain 31833 Btu/h Equipment type Heat pump Furnace. Heat pump, Boiler, etc. Model R4H436(A,G)KC* Heating output capacity 33800 Btu/h Heat pumps - capacity at winter design outdoor conditions Auxiliary heat output capacity Design airflow i External Static Pressure (ESP) Btu/h Form RPER 1.01 8 Mar 10 ATTACHED Yes QX No ❑ Yes 0 No FR Yes ❑X No ❑ Yes ❑ No QX Yes ❑ No nX Building Construction Information' Building Orientation (Front door faces) South North, East, West, South, Northeast, Northwest, Southeast, Southwest Number of bedrooms 4 Conditioned floor area 1 828 'Sq Ft Number of occupants 5 Windows Eave overhang depth 2.8' Ft Internal shade Blinds, drapes, etc Number of skylights Cooling Equipment Data Equipment type Heat purnp Air Conditioner, Heat pump. etc Model R4H436(A,G)KC* Sensible cooling capacity 281 98 Btu/h Latent cooling capacity 6129 Btu/h Total cooling capacity 34327 Btulh CFM Longest supply duct: IWC Longest return duct: Component Pressure Losses (CPL) IWC Total Effective Length (TEL) Available Static �ressure (ASP) IWC Friction Rate: ASP - ESP - CPL I Friction Rate = (ASP x 100) * TEL Contractor's Printed Name Contractor's i Blower Data Roof Eave Depth Window Heating CFM __12ja CFM Cooling CFM 1218 CFM Ft Duct Materials Used (circle) Trunk Duct: Duct board, Flex, Sheet metal, Ft Lined sheet metal, Other (specify) — Ft Branch Duct: Duct board, Flex, Sheet metal, IWC Lined sheet metal, Other (specify) Date 1 /11 /2019 The AHJ shall have the discretion to accept Required Attachments printed from approved ACCA software vendors, see list on page 2 of instructions. ' If abridged version of Manual J is used for load calculation, then verify residence meets requirements, see Abridged Edition Checklist on page 13 of instructions. Form generated by ACCA-approved Manual J Eighth Edition Version 2 Elite Software Rhvac program. Air Conditioning Contractors of America Manual �S (Residential Equipment Selection) Projectl Information Name: City: State: M Attitude: Altitude Adjustment: 1.00 Manual IJ Load Calculations Total Load Sensible Latent SHR 31833 28355 5478 0.828 Cooling Design Information Outdoor Design Tamp: 91 T db Summer Outdoor Design Temp: ® OF db 1Winter Indoor Design Tamp: 75 OF db ®%RH ® OF wb Heat Loss Airflow Calculations Design TD for Airflow 19 Design Sensible CFM 1261 'OEM information Manufacturer: COMFORTMAKER Furnace Model #: I AFUE:� Coil or -Coil Model #: FXM4X36-AL Condenser Fan Model #1 R4H4 A,G)KC` SEER: 15.0 HSPF: 8.20 i (A) Manufacturer's Cooling Performance Data Lower Return Air Outdoor Temperature = 95 (F db) Entering Coil Temperature = 75 (F db) CFM (F wb) Total BTUH Sensible BTUH Latent BTUH SHR Rated CFM Q Rated RA Temperature 85 34,370 23,800 10,770 0.6888 Rated CFM Q Design RA Temperature 1050 83 32,748 28,336 8,410 0.8043 Rated CFM Q Rated RA Temperature ® 30,310 30,440 -130 1.0043 I (B) Manufacturer's Cooling Performance Data Higher Return Air Outdoor Temperature = ® (F db) Entering Coll Temperature = 75 (F db) CFM (F wb) Total BTUH Sensible BTUH Latent BTUH SHR Rated CFM Q Rated RA Temperature 65 37,470 28,000 8,470 0.7473 Rated CFM @ Design RA Temperature 1550 ® 38,492 29,204 7,288 0.8003 Rated CFM Q Rated RA Temperature ® 35,025 31,010 47615 0.8854 I Manufacturses Cooling Performance Data (Interpolated) Design Return Air Outdoor Temperature - 95 (F db) CFM (F wb) Total BTUH Sensible BTUH Latent BTUH SHR 27,548 6,781 0.8025 Excess Latent Capacity Calculation + 851 851 Capacity a Design CFM / RA (F wb) 1�1 ® 34,8Z7 28,188 6,128 0.821 Equipment Capacity as a % of Design 107.83% 106,W 111.89% Asnufadgns 's Heat Pump Data Capacity Capacity Balance Supplemental b 0 17OF 820 b Point-183 Heat 15.671red 34,800 18, FManufacturrefs Furnace Data Input Output Desired Calculated