HomeMy WebLinkAboutPLAN REVIEW RECORDi
n 2015 INTERNATIONAL
Plan Review # 1810-0625
o� RESIDENTIAL CODE® Date: 10/7/18
' FOR ONE- AND TWO-FAMILY DWELLINGS Valuation:
PLAN REVIEW RECORD Fee:
JURISDICTION:
(City, County, Township, etc.)
BUILDING LOCATION: 8601 COBBLESTONE DR, FORT PIERCE, FL 34945
(Street address)
r
.. 'SCANNED
BUILDING•DESCRIPTION: SFR
a.
REVIEWED BY
Numerals paren mdicated iri thesis are-applibable code sections of e th2015 international Residential Code (1RC). The plan review accomplished as indicated '
_AnAhis record is'11mi4ed tothosecode sections.specificallyidentified herein. This recored references commonly applicable code sections`:Wth due=regard.for
the amount and'type of detailed rnforrilation which is typically found on coristruct�on documents for one- and two-family dwellings and townhouses' It.does
."hot"reference aikode provisions which may be applicable'to specific buildings This record is ilesignedto be used only by those ywho are "knowledgeable
s
nd,capable�ofevaluating consCruction'tlocumerits for code compliance.CORRECTIONS
LIST
No. ,
r
DESCRIPTION
Code
Section
PRODUCT APPOVAL 16103.1- R10 FOR THE SH WINDOW IS OUTDATED
PRODUCT APPOVAL 15216.1- R3 FOR THE ROOF UNDERLAYMENT IS OUT DATED
II
i
1CC •• • 1 o ••- o '-• o• o i - o• o -• a .• �• • • ,•o, • ••• • • • o Pqterlt, prio II IIIIIIIIIIIII III III III 9II781609II836115II����' ® ®m a
LI
me
CORRECTION LIST (cont'd.)
No. DESCRIPTION Code
Section
I
-2-
I
NOTE: Entries to this Plan Review Record that require a field check or inspection of the installation must be coordinated with the inspection phase (11109) of the project.
i BUILDING PLANNING (Chapter 3) .
DESIGN CRITERIA [Table R301.2(1)]
,Floo`ll r live load' (Table R301.5) x psf
Rooflive load (Table R301.6) x psf
Ground snow load psf
Ultimate design wind speed 160 mph
Wind exposure category (R301.2.1.4) 2-C
Highj wind design criteria applicable
(R301.2.1.1)
Seismic design category (SDC)
[Figure R301.2(2)]
SDC C&D provisions (R301.2.2)
.Weathering NEG
Frost) line depth
Termite area VH
Decay area
Winter design temperature
Ice barrier underlayment required,
Flood hazards X
FIRE-RESISTANT CONSTRUCTION (R302)
Exterior walls
(R302.1, Tables R302.1(1) and R302.1(2)J
Townhouse separation (R302.2)
Continuity and structural independence
(R302.2.1, R302.2.4)
ROOM PLANNING REQUIREMENTS (R303 through R305)
Parapets and construction
(R302.2.2, R302.2.3)
Two-family dwelling separation (R302.3)
Dwelling unit penetrations (R302.4)
Dwelling/garage opening/penetration, protec-
tion (R302.5)
X "Dwelling/garage fire separation (R302.6)
Under -stair protection (R302.7)
X Wall and ceiling finishes (R302.9)
X Flame spread index (R302.9.1)
X Smoke -developed index (R302.9.2)
Testing (R302.9.3, R302.9.4)
'Insulation. (R302.10)
X Flame spread/smoke-developed
(R302.10.1, R302.10.2)
Cellulose loose -fill and exposed attic
insulation (R302.10.3, R302.10.4)
Testing (R302.10.5)
X Fireblocking (R302.11)
X Draftstopping (R302.12)
Fire protection of floors (R302.13)
Combustible insulation clearance (R302.14)
Use
Area (ft2)
Width
Ceiling heights
Natural light*
Natural ventilation*
Living
70
7'-0"
T-0"
8% floor area
4% floor area
Dining
70
T-0"
T-0"
8% floor area
4% floor area
Kitchen
N.A.
N.A.
7'-0"
8% floor area
4% floor area
Bedroom
70
7'-0"
7'-0"
8% floor area
4% floor area
Bathroom
N.A.
N.A
6'-8"
3 square feet
1 V, square feet
See Sections
t 6'-8" min.
R303.1 & R303.3 for mechanical ventilation and artificial light and R303.4 for required whole -house mechanical ventilation.
at plumbing fixtures and for non -habitable basements.
Required heating (R303.9)
GLAZING (R308)
SAM lATI
ION (R306 and R307)
Identification (17308.1)
X i Water closet
Louvered windows or jalousies (R308.2)
X I Lavatory
Human impact loads/hazardous locations
X
(R308.3, R308.4)
Tub or shower
Skylights and sloped glazing (R308.6)
X Kitchen.area with sink
X Sanitary sewer (Chapter 30)
X i Private disposal (Appendix I)
I '
-3-
BUILDING PLANNING (cont'd.)
GARAGES AND CARPORTS (R309)
X Floor surface noncombustible; sloped floor
(R309.1)
X Carport: open, two sides; noncombustible
floors; sloped floor (R309.2)
Automatic garage door opener (R309.4)
Fire sprinklers (R309.5)
EMERGENCY ESCAPE AND RESCUE OPENINGS
(R310)
X Where required.(R310.1)
X Areas, height, width, operations (R310)
Window wells (R310.2.3)
'Under decks and porches (R310.2.4)
Bars, grilles, covers and screens (R310.4)
MEANS OF EGRESS (13311)
X General (R311.1)
X Egress door (R311.2)
Landings at exterior doors
(13311.3 - R311.3.3)
Vertical egress (R311.4)
Construction and attachment (R311.5)
X Hallways (R311.6)
Stairway width, headroom, vertical rise, walk -
line (R311.7.1 - R311.7.4)
Stairway treads, risers profiles
(R311.7.5 - R311.7.5.4)
Stairway landings and walking surfaces
(R311.76, R311.7.7)
Handrails required (R311.7.8)
Handrail height, continuity, grip -size
(R311.78.1 - R311.Z8.4)
Stairway illumination (R303.7, R311.Z9)
Special stairways (R311.Z'10)
Ramp slope, landings, handrails (R311.8)
GUARDS AND WINDOW PROTECTION (R312)
Required,for open -sided surfaces, stairs,
ramps and landings > 30" above floor/
grade. (R312.1.1)
Height - 36" (R312.1.2)
Opening limitations (R312.1.3)
Window fall protection (R312.2)
-4-
AUTOMATIC FIRE SPRINKLER SYSTEMS (R313)
Townhouses (R313.1)
One- and two-family dwellings (R313.2)
SMOKE ALARMS (R314)
Referenced standards (R314.1)
X Location and interconnection
(R314.3, R314.4)
Power source (R314.6)
CARBON MONOXIDE ALARMS (R315)
X New construction (R315.1, R315.2)
Existing construction (R315.2.2)
Referenced standard (R315.6)
FOAM PLASTIC (R302.8, R316)
Labeling (R316.2)
Surface burning, thermal barrier, specific
approval.(R316.3 - R316.8)
DECAY AND TERMITE PROTECTION (R317 and R318)
Protection -required
(Table R301.2(1), R317.1, R318.1),
Quality mark (R317.2 and R318.1.1)
SITE ADDRESS (R319)
Address numbers (R319.1)
ACCESSIBILITY (R320)
i
Type B dwelling units applicable (R3 0.1)
ELEVATORS/PLATFORM LIFTS (11321)
I
Referenced -standards (R321.1 - R3 i.3)
FLOOD -RESISTANT CONSTRUCTION (R322)
General (R322.1) j
Hazard area and requirements
(R301.2.4, R309.3, R322.2, R322.3)
Design professional (R322.3.6)
STORM SHELTERS (R323)
General/referenced standard (R323. j1)
SOLAR ENERGY SYSTEMS (R324)
System, installation, access
(R324.2 - R324.7)
MEZZANINES (R325)
Area, egress, openness. (13325.2 - R325.5)
SWIMMING POOLS, SPAS AND HOT TUBS (R326)
ISPSC (R326.1)
FOUNDATIONS (Chapter 4)
MATERIALS (R402)
;Wood foundations (R402.1)
Concrete, compressive strength
(R402.2, R402.3)
FOOTINGS (R403)
X Soil. bearing value (R401.4, R403.1)
X I Footing width
(Tables R403.1(1) - R403.1(3)]
X I Footing edge thickness; footing projection =
2" minimum, but <_ footing thickness
(R403.1.1)
I Footings in SDC and D
(R403.1.2 and R403.1.6.1)
X I Depth below (outside) grade = 12" minimum;
but below frost line (R403.1.4, R403.1.4.1)
X I Sill plate bolting in concrete/masonry ='/2" di-
ameter bolts, within 12" but not less than 7
bolt diameters from ends, 7" embedment
(R403.1.6)
Footings adjacent to slopes (R403.1.7)
Frost -protected shallow foundations (R403.3)
Footings for precast concrete foundations
(R403.4)
FOUNDATION/RETAINING WALLS (R404 - R406)
Masonry foundation walls (R404.1.2)
Wall height, unbalanced backfill, nominal
thickness (Tables R404.1.1(1) -
R404.1.1(4), R404.1.5.1]
Reinforcement size and spacing.
(Tables R404.1.1(2) - R404.1.1(4)]
Concrete foundation walls (R404.1.3)
Wall height, unbalanced backfill, nominal
i thickness (Tables R404.1.2(i) -
R404.1.2(8), R404.1.5.2]
-5-
Horizontal and vertical reinforcement size_ and
spacing (Tables R404.1.2(1) -
R404.1.2(8), R404.1.3.2, R404.1.3.3.71
Stay -in -place forms (R404.1.3.3.6.1)
SDC D provisions (R404.1.4)
Height above finished grade (R404.1.6)
Sill plate size (R404.3)
Precast concrete foundation walls (R404.5)
Drains required if habitable. or usable spaces
are below grade* (R405)
Soil class (Table R405.1)
Dampproofing if basements are below grade.*
(R406.1)
Waterproofing if,high water'table* (R406.2)
* If uninhabitable, see Under -Floor Space (R408)
COLUMNS (R407)
Protection from decay or corrosion
(R407.1 and R407.2)
X Structural requirements (R407.3)
Anchorage (R4073)
Wood columns (minimum 4" square) (R407.3)
Steel columns (minimum 3" diameter, Sched-
ule 40 pipe) (R407.3)
UNDER -FLOOR SPACE (R408)
Ventilation (R408.1 and R408.2)
Unvented crawl space (R408.3)
Access (R408.4)
Removal of debris (R408.5)
Finished grade (R408.6)
Flood resistance (R408.7)
FLOORS (Chapter 5)
WOOD JOISTS AND GIRDERS (13502)
Species and grade (R502.1)
Joists —Sleeping areas, LL = 30 psf
[Table R502.3.1(1)]
Joists—Nonsleeping areas, LL = 40 psf
[Table R502.3.1(2)]
Cantilevered joists
[Tables R502.3.3(1) and R502.3.3(2)]
Girder and header spans
[Tables R602.7(1) - R602.7(3)]
Joists under bearing partitions (R502.4)
Bearing (1.5" minimum on wood or metal; 3"
on masonry or concrete) and lapped joists
(3") (R502.6, R502.6.1)
Lateral restraint and bridging
(R502.7, R502.7.1)
Drilling and notching (R502.8)
Fastening (R502.9)
Framing of openings (R502.10)
Wood trusses (R502.11)
Draftstopping (R502.12)
LUMBER FLOOR SHEATHING (R503.1)
Allowable span (Table R503.1)
End joints (R503.1.1)
WOOD STRUCTURAL PANEL SHEATHING (R503.2)
Grade (R503.2.1)
Thickness (R503.2.1)
Allowable spans
[Tables R503.2.1.1(1) and R503.2.1.1(2)]
Installation [Table 602.3(1)]
PARTICLEBOARD UNDERLAYMENT (R503.3)
Grade (R503.3.1)
Thickness (R503.3.2)
Installation [Table R602.3(1)]
0
TREATED -WOOD FLOORS (ON GROUND) (R504)
Base course: 4" thick with maximum 3/4"
gravel or'/," crushed stone (R504.2.1)
Moisture barrier: placed over base course
(R504.2.2)
Materials (R504.3)
STEEL FLOOR FRAMING (R505)
Cold -formed steel; applicability limits;
in -line framing (R505.1)
Structural framing (R505.2)
Material (R505.2.1)
Corrosion protection (R505.2.2)
Identification (R505.2.4)
Fastening (R505.2.5)
Floor construction (R505.3)
CONCRETE FLOORS (ON GROUND) (R506)
X Thickness: 31/2" minimum; Concrete strength
(R506.1) 1
X Support: prepared subgrade; maximum earth
fill = 811; maximum sand or gravel fill = 24"
(R506.2.1)
Base course: 4" graded with 2" maximum
aggregate (R506.2.2)
X Vapor retarder (R506.2.3)
X Reinforcement support (R506.2.4)
EXTERIOR DECKS (R507)
Support, attachment (R5071 - R&
Plastic composite materials (R507.
Decking/deck joists (R507.4, R507.
Deck beams (R5076)
Deck posts, connections, footings
(R507.71, R507.8)
WALL CONSTRUCTION (Chapter 6)
I
WOOD CONSTRUCTION (R602)
X!
Construction
('Figures R602.3(1) and R602.3(2)]
Stud grade (R602.2)
X i Design/construction (13602.3)
X stud spacing [R602.3.1, Table R602.3(5)]
interior load -bearing walls (R602.4)
X
I Interior nonbearing walls: 2" 'x 311 at 24" o.c.
or 2" x 4" flat at 16" o.c. (R602.5)
Drilling and notching —studs (R602.6)
Drilling and notching —top plate (R602.6.1)
X Headers.(Tables R602.7(1) - R602.7(3) and
Figure R602.7.2]
Fireblocking (R602.8, R302.11)
I
Cripple walls (R602.9)
Wall bracing, lines; panels
(R602.10.1, R602.10.2)
Required'length of bracing,. method
(R602.10.3, R602.10.4, Tables
R602.10.3(1) and R602.10.3(3)]
i Minimum length, connections, support, joints,
cripple walls (R602.10.5 - R602.10.11)
Wall anchorage (SDC C and D) (R602.11)
Simplified wall bracing (13602.12)
STEEL WALL FRAMING (R603)
1 General (R603.1)
Structural framing (R603.2)
Material (R603.2.1)
Corrosion protection (R603.2.2)
Identification (R603.2.4)
Fastening (R603.2.5)
Wall construction (R603.3 - R603.5)
Headers (R603.6)
Studs, tracks and structural sheathing
(17603.7 - R603.9)
SHEATHING (R604 and R605)
X Wood structural panels,(R604)
Particleboard (13605).
MASONRY CONSTRUCTION (R606 - R610)
X General design (R606)
Seismic requirements (R606.12)
Glass unit masonry (R607)
X Exterior concrete wall construction (R608)
X Exterior windows/doors (R609)
Glass unit masonry (R610)
STRUCTURAL INSULATED PANEL WALL
CONSTRUCTION (R610)
Applicability (13610.2)
Materials (R610.3)
Wall panels, construction details'
(R610.4 - R610.10)
-7-
WALL COVERING (Chapter 7)
INTERIOR WALL COVERING (13702)
Plaster material (R702.2)
Plaster support (R702.2.3)
X Gypsum board materials (R702.3.1)
Gypsum board support, application and fas-
tening (R702.3.2 - R702.3.7)
X Ceramic tile. (R702.4)
Other finishes (R702.5 and R702.6)
Vapor retarders (R702.7)
EXTERIOR WALL COVERING (R703)
X Water-resistive,barrier (R703.2)
X Attachment and minimum thickness
[Table R703.30)J
Wood siding (R703.5)
Wood shakes -and shingles (R703.6
Exterior plaster (R703.7)
Stone & masonry veneer (R703.8 &
R703.8); Steel angle lintels-4" m
bearing each end (R703.8.3)
Veneer ties: #9 U.S. gage wire,or #2
gage by 7/8" corrugated.metal; he
and vertical,,spacing;2.67. square
maximum area supported (wind
and SDC C or.D, maximum area
square feet) (R703.8.4.1)
Flashing (R703.4 and R703.8.5)
Exterior insulation and finish system,
(R703.9)
Fiber cement siding (R703.10)
Vinyl siding (R703.11)
Other sidings (R703.12 - R703.17)
ROOF -CEILING CONSTRUCTION (Chapter 8)
WOOD ROOF FRAMING (R802)
Fire -retardant -treated wood (R802.1.5)
Framing details (R802.3)
Rafter ties (R802.3.1)
Collar ties (4' o.c., in upper third of attic)
(R802.3.1)
Purlins (2" .x 4" at 4' o.c. minimum)
(Figure R802.5.1, R802.5.1)
Bearing (R802.6)
Cutting and notching (R802.7)
X Engineered wood products (R802.7.2)
Lateral support and bridging (R802.8)
Framing .of openings (13802.9)
X Wood trusses (R802.10)
Roof tie -down (R802.11)
CEILING JOISTS [Tables R802.4(1), R802.4(2)]
X Without attic storage, LL = 10psf
X With attic storage LL = 20psf
X Spacing
Species and grade
X
Span
X Size
RAFTERS [Tables R802.5.1(1) - R802.5.1(8)]
Ground snow load/LL = 20 psf
Controlling design (LL or snow)
Ceiling not attached/ceiling attached
Spacing
Species and grade
Span
Size
Hc/HR; Adjustment factor
ROOF SHEATHING (R803.2)
Grade
X Thickness
FRTW allowable stresses/grading
X Allowable spans [Table R503.2.1.1(1)]
X Installation (R803.2.3)
' U.
30 psf
2
-8-
ROOF -CEILING CONSTRUCTION (cont'd.)
STEEL ROOF FRAMING (R804) Roof construction (R804.3)
General (R804.1) Roof tie -down (R804.3.8)
Structural framing (R804.2)
ROOF VENTILATION (R806)
Material (R804.2.1) X Ventilation requirements (R806.1 - R806.5)
Corrosion protection (R804.2.2)
Identification (R804.2.3) ATTIC ACCESS (13807)X
Access requirements (807.1)
Fastening (R804.2.5)
ROOF ASSEMBLIES (Chapter 9)
ROOF CLASSIFICATION (R902)
X Roof covering. materials (R902.1)
WEATHER PROTECTION (R903)
I Flashing (R903.2)
I
Coping (R903.3)
Roof drainage (R903.4)
i
MATERIALS (13904)
X Compatibility; specifications;,, physical charac-
teristics; identification- (R904.2 - R904.4)
REQUIRi MENTS FOR ROOF COVERINGS (R905)
X Underlayment (R905.1.1, R905.1.2)
X Asphalt shingles (R905.2)
Clay and concrete tile (R905.3)
Metal roof shingles (R905.4)
I
Mineral -surfaced roll roofing (R905.5)
NOA / PA Metal roof panels (R905.10)
NOA / PA Modified bitumen roofing (R905.11)
NOA / PA Thermoset single -ply roofing (R905.12)
NOA / PA Thermoplastic single -ply roofing (R905.13)
NOA / PA Sprayed polyurethane foam roofing (R905.14)
NOA / PA Liquid -applied roofing (R905.15)
NOA / PA Photovoltaic shingles (R905.16)
ROOF INSULATION (R906)
General (R906.1)
ROOFTOP - MOUNTED PHOTOVOLTAIC SYSTEMS
(R907)
Materials and installation (R907.1 - R907.5)
REROOFING (R908)
Materials and methods (R908.1)
Structural support (R908.2)
Slate shingles (R905.6) Replacement/re-covering (R908.3, R908.4)
Wood shingles (R905.7) ROOFTOP - MOUNTED PHOTOVOLTAIC
Wood shakes (R905.8) PANEL SYSTEMS (R909)
Built-up roofs (R905.9) Materials and installation (R909.1 - R909.3)
CHIMNEYS AND FIREPLACES (Chapter 10)
MASONRY FIREPLACES (R1001)
Construction
(Figure R1001.1 and Table R1001.1)
SDC D reinforcing/anchorage
(R1001.3 and R1001.4)
Firebox walls,and dimensions
(R1001.5 and R1001.6)
Steel fireplace units (R1001.5.1)
Lintel (noncombustible) (R1001.7)
Hearth extension (R1001.9, R1001.10)
Fireplace clearance (R1001.11)
Fireblocking (R1001.12)
MASONRY CHIMNEYS (R1003)
Construction (Table R1001.1, R1003.2,
R1003.3, and Figure R1001.1)
Corbeling (R1003.5)
0