HomeMy WebLinkAboutPRODUCT REVIEW AFFIDAVITBuilding Permit #
Planning & Development Services Department
Building & Regulations Division —
Product Review Affidavit
Owners Name Applicant
Product
Opening Design
Product Rated
Manufacturer
Model#
Product Approval
Glass Type
Method of Attachment
Pressure
Design Pressure
Number
1/4" concrete screw 6" edge distance @ head, 4" edge
Swing door
(+36) / (-47)
(+67) / (-67)
Therma-Tru
Smooth Star
FL5891.2
N/A
distance @ jamb, 4" each side of transom centerline to
bucking. Fastener spacing @ 15" o/c max. @ head and
jamb. Min. embedment of all anchors to be 11/4"
Type 1: 3/16" or 1/4" ELCO Ultracon anchor 6" max. from
corners, 113/4" o/c at jamb, 16" @ head. 11/4"
embedment. Type II: 3/16" or 1/4" ITW concrete tapcon
SH Window
(+38) / (-48)
(+50) / (-50)
Ply Gem
Ply Gem 150D
FL16103.1
Non Impact
anchor. 6" max, from corners, 7 1/4" o/c at jamb, 101/4"
@ head. 11/4" embedment. Two additional tapwns
midspan and one at lower frame required vertically each
side. Install per manufacturers recommended
requirements.
I
Type 1: 3/16" or 1/4" ELCO Ultracon anchor 6" max. from
corners, 14" o/c at jamb, 10" @ head. 11/4" embedment.
'
Type ll: 3/16" or 1/4" ITW concrete.tapcon anchor. 6" max.
SH Window (Integral
(+38) / (-48)
(+50) / (-55)
Ply Gem
Ply Gem 1500
FL16100.1
Non Impact
from corners, 8 1/2" o/c at jamb, 6" @ head. 1 1/4"
Mulled)
embedment. Eight additional tapwns top and bottom
required horitontally', one midspan vertically each side.
Install per manufacturers recommended requirements.
1/4" concrete tapcon anchor. 2 1/2" minimum edge
SlidingGlass Door
+33 41
( ) / (- )
+So
( ) / (-50)
Ply Gem
Builders Series
FL14634.2
Non Impact
distance. 6" max o/c from corners and 20 3/4" max o/c
4780
elsewhere top, vertically and bottom. 2 1/2" min
embedment.
1/4" concrete tapcon anchor. 6" max o/c for corners.
Tapcon required 3" each side of center of opening top and
Opaque single door
+36 47
( ) / ( )
(+47) / (-07)
Therma-Tru
Smooth Star
FL20461.17
N/A
bottom. Top and bottom centerline of each door slab get
with transom
tapcon. Rest of vertical o/c spacing is 14" max. 11/4"
i
embedment.
3/8" x 2-3/4" Hilti sleeve anchors 6" from ends 22" O/C
Double Garage Door
(+29) / (-35)
(+46) / (-42)
Clopay
16.2x7 73 W6
FL36546.6
N/A
Use galvanized (zinc coated) roofing nails, 11 or 12 gauge,
i
with at least 3/8" dia. heads, long enough to penetrate
.
through plywood or 3/4" into boards. Use 4 nails per
Roof
IKO Cambridge
FL7006.1
shingle placed 6-1/8" above the butt edge, approx. 1" and
13" from each end and 1/2" above each'cutout. Drive
nails straight so that nail head is flush with, but not
'
cutting into shingle surface.
Miami -Dade approved corrosion resistant tin -caps and 12
Undeflayment
Interwrap
RhinoRoof U20
FL15216.1
gauge 1'/." annular ring -shank nails,
spaced 6" c.c. at all laps and threestaggered rows
'I
fastened 12" o.c. in the field of the roll
Soffit
+31.6, -38.8
(+157) / (46.1)
I PlyGem
Variform Soffits
FL24161.1
1/4" x 20 stainless steel or ELCO Panelmate with minimum
Hurricane Panels
Hurricane Storm
embedment @ 1 3/4" in concrete / masonry, 21/2" min.
Less than 6' span
(+47) / (-53)
panel MFG.
24 GAGE
FL36293.1
edge distance, 12" o/c max. spacing. Can be headed screw
or all thread but with wing nuts.
1/4" x 20 stainless steel or ELCO Panelmate with minimum
Hurricane Panels 6'
Hurricane Storm
embedment @ 1 3/4" in concrete / masonry, 2 1/2" min.
span or more
(+45) / (-50)
panel MFG.
24 GAGE
FL16293.1
edge distance, 12" o
g /t max. spacing. Can beheaded screw
or all thread but with wing nuts.
Zip system
Install per manufacturers recommended requirements.
Sheathing
Huber
Wall Sheathing
17147.1
1441 N. RONALD REAGAN BLVD.
LONGWOOD, FL 32750
PH: 407-774-6078
FAX: 407-7744078
www.abdesigngioup.com
AA #: 0003325 Of
W
y
w
0
4
U
y
c
O
[8i73BDLv & W
CREEKSIDE
]PROJECT#
04321.000
MODEL:
4EBB
"1828-CALI'
GARAGE 81PIL M
LEFT
PAGE:
PRODUCT
APPROVALS
160 MPH EXP C
ARCHMECT:
STATE OF FLORIDA
SCANNED
BY
Lucie County
ROLAND A. ABOUCHACRA
AR NO 93723
DIUNT
A E: 09/13/18
BCALM 1/4"=V-0"
SE'LEET
D