Loading...
HomeMy WebLinkAboutPLAN REVIEW RECORDi 2015INTERNATIONAL Plan Review # 1810-0624 Q RESIDENTIAL CODE® 1 orzil s Date: ' FOR ONE- AND TWO-FAMILY DWELLINGS Valuation: PLAN REVIEW RECORD. Fee: 'BY ` St Lucie Count JURISDICTION: Y (City, coun'ty,: Township, etc,) ,,:BUILDING LOCATION: 8744 COBBLESTONE DR FORT. PIERCE, FL 34945- u _ (Street address) BUIL(DINGDESCRIPTION SFR z r REVIEWED BY.. Numerals indicated in parenthesis are applicablg code sections"of the 2015 In&rhationai Residential Code.(!RC). The plan review accomplished as indicated =: �n this record is limded to,tfiose code sections specfically identified herem; This recored references commonly applicable code sections vnth d"ue regard -for the amount and type of detailed mfo matloh which is,typicaliy fourid on constructlon'docUrn nts,for one -`and two-family dwellings andgtownhouses: it does ' not reference all code provisions which may be appi�cable toespecific btiddmgs Thls record is designed to, be used of11Y by those who are knov0dogeable ,w a z,�m av and,capable of exercising-. Otentaudgmentan='evaivatmg construction=siocuments for code compUance., CORRECTIONS LIST Code No. DESCRIPTION Section PRODUCT APPOVAL 16103.1- R10 FOR THE SH WINDOW IS OUT DATED PRODUCT APPOVAL 15216.1- R3 FOR THE ROOF UNDERLAYMENT IS OUT DATED i i I I Copyright,115,; International CodeCouncil,'EReproduction by prohibited. ICC ISBN 978-1-60983-611-5 JCC s the trademarkof •nal Code Council,and is registered in the U.S. Patent and \\iTrademark Office. For additional forms, contact: IIIIIIIIIIII III III III III INTERNATIONAL INTERNATIONAL CODECOUNCIL,9 781609II836115II CODE COUNCIL'PHONE• ' -1- CORRECTION LIST (cont'd.) No. DESCRIPTION Code Section NOTE: Entries to this Plan Review Record that require a field check or inspection of the installation must be coordinated with the inspection phase (R109) of the project. BUILDING PLANNING (Chapter 3) DESIGN CRITERIA [Table-R301.2(1)] Floor live load (Table R301.5) x psf Roof 'live load (Table R301.6) x psf Ground snow load psf 'Ultimate design wind speed 160 mph Wind exposure category (R301.2.1.4) 2-C High d design criteria applicable )1.2.1.1) design category (SDC) ire R301.2(2)] SDCI C&D provisions (R301.2.2) _ WaathPrinn NEG line area VH Decay area Winter design temperature Ice barrier underlayment required Flood hazards X FIRE-RESISTANT CONSTRUCTION (R302) Exterior walls (R302.1, Tables R302.1(1) and R302.1(2)] Townhouse separation (R302.2) Continuity and structural independence (R302.2.1, R302.2.4) I I ROOM PLANNING REQUIREMENTS (R303 through R305) Parapets and construction (R302.2.2, R302.2.3) Two-family dwelling separation (R302.3) Dwelling unit penetrations (R302.4) .Dwelling/garage opening/penetration protec- tion (R302.5) X Dwelling/garage fire separation (R302.6) Under -stair protection (R302.7) X Wall and ceiling finishes (R302.9) X Flame spread index (13302.9.1) X Smoke -developed index (R302.9.2): Testing (13302.9.3, R302.9.4) Insulation (R302.10) X Flame spread/smoke-developed (R302.10.1, R302.10.2). Cellulose loose -fill and exposed attic insulation (R302.10.3, R302.10.4) Testing (R302.10.5) X 'Fireblocking (R302.11) X Draftstopping (R302.12) Fire protection of floors (R302.13) Combustible insulation clearance (R302.14) Use Area (ft2) Width Ceiling height' Natural light` Natural ventilation* Living 70 7'-0" T-0" 8% floor area 4% floor area Dining 70 7'-0" T-0" 8% floor area 4% floor area Kitchen N.A. N.A. T-0" 8% floor area 4% floor area Bedroom 70 7'-0" 7'-0" 8% floor area 4% floor area Bathroom N.A. N.A 6'-8" 3 square feet 1 V, square feet See Sections R303.1 & R303.3 for mechanical ventilation and artificial light and R303.4 for required whole -house mechanical ventilation. t 6'-8" min. at plumbing fixtures and for non -habitable basements. f I Required heating (R303.9) SANITATION (R306 and R307) X i Water closet X Lavatory X Tub or shower X Kitchen area with sink' X I Sanitary, sewer (Chapter 30) X Private disposal (Appendix 1) -3- GLAZING (R308) Identification (R308.1) Louvered windows or jalousies (R308.2) Human impact loads/hazardous locations (R308.3, R308.4) Skylights and sloped glazing (R308.6) BUILDING PLANNING (cont'd.) GARAGES AND CARPORTS (R309) X Floor surface. noncombustible; sloped floor (R309.1) X Carport: open two sides; noncombustible floors; sloped floor (R309.2) Automatic garage door opener (R309.4) Fire sprinklers (R309.5) EMERGENCY ESCAPE AND RESCUE OPENINGS (R310) X Where required (R310.1) X Areas, height, width, operations (R310) Window wells (R310.2.3) Under decks and porches (R310.2.4) Bars, grilles, covers and screens (R310.4) MEANS OF EGRESS (R311) X General (R311.1) X Egress door (R311.2) Landings at exterior doors (R311.3 - R311.3.3) Vertical egress (R311.4) Construction and attachment (R311.5) X Hallways (R311.6) Stairway width, headroom, vertical rise, walk - line (R311.7.1 - R311.7.4) Stairway treads, risers profiles (R311.7.5 - R311.7.5.4) Stairway landings and walking surfaces (R311.7.6, R311.7.7) Handrails required (R311.78) Handrail height, continuity, grip -size (R311.7.8.1 - R311.7.8.4) Stairway illumination (R303.7, R311.7.9) Special stairways (R311.710) Ramp slope, landings, handrails (R311.8) GUARDS AND WINDOW PROTECTION (R312) Required for"open-sided surfaces, -stairs, ramps and landings > 30" above floor/ grade (R312.1:1) Height -'36" (R312.1.2) Opening limitations (R312.1.3) Window fall protection (R312.2) -4- AUTOMATIC FIRE SPRINKLER SYSTEMS (R3 Townhouses (R313.1) One- and two-family dwellings (R31 SMOKE ALARMS (R314) Referenced standards (R314.1) X Location and interconnection (R314.3, R314.4) Power source (R314.6) CARBON MONOXIDE ALARMS (R315) X New construction (R315.1, R315.2) Existing construction (R315.2.2) Referenced standard (R315.6) FOAM PLASTIC (R302.8, R316) Labeling (R316.2) Surface burning, -thermal barrier, spe approval (R316.3 - R316.8) DECAY AND TERMITE PROTECTION (R317 am Protection required (Table R301.2(1), R317.1, R318.1 Quality mark (R317.2 and R318.1.1) 3) i R318) SITE ADDRESS (R319) Address numbers (R319.1) ACCESSIBILITY (R320) Type B dwelling units applicable (R32,0,.1) ELEVATORS/PLATFORM LIFTS (13321) Referenced standards (R321.1 - R32 13) FLOOD -RESISTANT CONSTRUCTION (R322) General (R322.1) Hazard area and requirements (R301.2.4, R309.3, R322.2, R322. Design professional (R322.3.6) STORM SHELTERS (R323) General/referenced standard (R323.1 SOLAR ENERGY SYSTEMS (13324) j _System, installation, access (R324.2 - R324.7) MEZZANINES (R325) Area, egress, openness, (R325.2 - R3, SWIMMING POOLS, SPAS AND HOT TUBS (R32 ISPSC (R326.1) 5) FOOTI N X- X X FOUNDATIONS (Chapter 4) (R402) Wood foundations (R402.1) ;Concrete, compressive strength (R402.2, R402.3) (R403) 'Soilbearing value (R401.4, R403.1) .Footing width (Tables R403.1(1) - R403.1(3)] :Footing edge, thickness; footing projection = 2" minimum, but <_ footing thickness (R403.1.1) Footings in SDC and D (R403.1.2 and R403.1.6.1) X Depth below (outside) grade = 12" minimum; but below frosftine (R403.1.4, R403.1.4.1) X Sill plate bolting in concrete/masonry ='/2' di- ameter bolts; within,l2", but not less than 7 ,bolt'diameters from ends, 7" embedment (R403.1.6) Footings adjacent to slopes (R403.1.7) Frost -protected shallow foundations (R403.3) Footings for precast concrete.foundations (R403.4) JDAIION/RETAINING WALLS (R404 - R406) Masonry foundation walls (R404.1.2) Wall`height, unbalanced backf ill, nominal thickness [Tables R404.1.1(1) - R404.1.1(4), R404.1.5.1] .Reinforcement size and spacing (Tables R404.1.1(2) - R404.1.1(4)] Concrete foundation walls (R404.1.3) Wall height, unbalanced backfill, nominal thickness (Tables R404.1.2(1) - R404.1.2(8), R404.1.5.2] Horizontal and.vertical reinforcement size and: .spacing'(Tables R404.1.2(1) - R404.1.2(8), R404.1.3.2, R404.1.3.3.7] Stay -in -place forms (R404.1.3.3.6.1) SDC D provisions (R404.1.4) Height above finished grade (R404.1.6) Sill plate size (R404.3) Precast concrete foundation walls (R404.5) Drains required if habitable or usable spaces are below grade` (R405) Soil class (Table R405.1) Dampproofing if basements,arebelow grade* (R406.1) Waterproofing if high water table* (R406.2) * If uninhabitable, see Under -Floor Space (R408) COLUMNS (R407) Protection from decay or corrosion (R407.1 and R407.2) X Structural requirements (R407.3) Anchorage (R407.3) Wood columns (minimum 4" square) (R407.3) Steel columns (minimum W diameter, Sched- ule 40 pipe) (R407.3) UNDER -FLOOR SPACE (R408) Ventilation (R408.1 and R408.2) Unvented crawl space (R408.3) Access (R408.4) Removal of debris (R408.5) Finished grade (R408.6) Flood resistance (R408.7) -5- FLOORS (Chapter 5) WOOD JOISTS AND GIRDERS (R502) Species and grade (R502.1) Joists—Sleeping,areas,_LL = 30 psf [Table R502.3.1(1)] Joists—Nonsleeping areas, LL = 40 psf [Table R502.3.1(2)] Cantilevered joists (Tables R502.3.3(1) and R502.3.3(2)] Girder and header spans (Tables R602.7(1) - R602.7(3)] Joists,under bearing partitions (R502.4) Bearing (1.5" minimum on wood or metal; 3" on masonry or concrete) and lapped joists (3") (R502.6, R502.6.1) Lateral restraint and bridging (R502.7, R502.7.1) Drilling and notching (R502.8) Fastening (R502.9) Framing of openings (R502.10) Wood°.trusses (R502.11) Draftstopping (R502.12) LUMBER FLOOR SHEATHING (R503.1) Allowable span (Table R503.1) End joints (R503.1.1) WOOD STRUCTURAL PANEL SHEATHING (R503.2) Grade (R503.2.1) Thickness (R5032.1) Allowable spans (Tables R5032.1.1(1) and R503.2.1.1(2)] Installation [Table 602.3(1)] PARTICLEBOARD UNDERLAYMENT (R503.3) Grade (R503.3.1) Thickness (R503.3.2) Installation [Table R602.3(1)] TREATED -WOOD FLOORS (ON GROUND) (R504) Base course: 4" thick with maximum i3/4" gravel or'/Z" crushed stone (R504.2.1) Moisture barrier: placed over base course (R504.2.2) Materials (R504.3) STEEL FLOOR FRAMING (R505) Cold -formed steel; applicability limit in -line framing (R505.1) Structural framing (R505.2) Material (R505.2.1) Corrosion protection (R505.2.2) Identification (R505.2.4) Fastening (R5052.5) Floor construction (R505.3) CONCRETE FLOORS (ON GROUND) (R506) X Thickness: 3'/2" .minimum; Concrete (R506.1) X Support: prepared subgrade; maximu fill = 8'; maximum sand or gravel (R5062.1) Base course: 4" graded with 2" max aggregate (R506.22) X Vapor retarder (R5062.3) X Reinforcement'support (R5062.4) EXTERIOR DECKS (R507) Support,'attachment (R507.1 - R50i Plastic composite materials (R507.3 Decking/deck joists (R507.4, R507.5 Deck beams (R507.6) Deck posts, connections, footings (R50771, R507.8) earth = 24" ?.4) l.1 WALL CONSTRUCTION (Chapter 6) WOOD CONSTRUCTION (R602) Material (R603.2.1) X I Construction Corrosion protection (R603.2.2) i [Figures R602.3(1) and R602.3(2)] Identification (R603.2.4) grade (R602.2) X I Design/construction (R602.3) X I Stud spacing [R602.3.1, Table R602.3(5)] Interior load -bearing, walls (R602.4) X I Interior nonbearing walls: 2" x 3" at 24" o.c. or 2" x 4" flat at 16".o.c. (R602.5) Drilling and notching —studs (R602.6) Drilling and notching —top plate (R602.6.1) X i, i Headers (Tables R602.7(1) - R602.7(3) and Figure R602.7.2] Fireblocking (R602.8, R302.11) Cripple walls (R602.9) Wall bracing, lines, panels (R602.10.1, R602.10.2) Required length of bracing, method (R602.10.3, R602.10.4, Tables R602.10.3(1) and R602.10.3(3)] Minimum length, connections, support, joints, cripple walls (R602.10.5 - R602.10.11) Wall anchorage (SDC C and D) (R602.11) Simplified wall bracing (R602.12) I STEEL WALL FRAMING (R603) General (R603.1) Structural framing (R603.2) Fastening (R603.2.5) Wall construction (R603.3 - R603.5) Headers (13603.6) Studs, tracks and structural sheathing (13603.7 - R603.9) SHEATHING (R604 and R605) X Wood structural panels (R604) Particleboard (R605) MASONRY CONSTRUCTION (R606 - R610) X General design (R606) Seismic requirements (R606.12) Glass unit masonry (R607) X Exterior concrete wall construction (R608) X Exterior windows/doors (R609) Glass unit masonry (R610) STRUCTURAL INSULATED PANEL WALL CONSTRUCTION (R610) Applicability (R610.2) Materials (R610.3) Wall panels, construction details (17610.4 - R610.10) -7- WALL COVERING (Chapter 7) INTERIOR WALL COVERING (R702) Wood, shakes and shingles (R703.6) Plaster material (R702.2) Exterior plaster (R703.7) Plaster support (R702.2.3) Stone & masonry veneer (13703.8 Figure X Gypsum board materials (13702.3.1) R703.8); Steel angle lintels-4" bearing each end (R703.8.3) n mimum Gypsum board support, application and fas- Veneer ties: #9 U.S. gage wire or #22 U.S: tening (R702.3.2 - R702.3.7) gage by'/e' corrugated metal; horizontal X and, vertical spacing; 2.67 squarelfeet. Ceramic tile (R702.4) maximum area supported (wind '; 30 psf Other finishes (13702.5 and R702.6) and SD.0 C or D, .maximum area square feet) (R703.8.4.1) ;T 2 Vapor retarders (R702.7) Flashing (R703.4 and R703.8.5) EXTERIOR WALL COVERING (R703) Exterior insulation and finish systerr s X Water-resistive barrier (R703.2) R (703.9) X Attachment and minimum thickness Fiber cement siding (R703.10) [Table R703.3(1)] Vinyl siding (13703.11) Wood siding (R703.5) Other sidings (R703.12 - R703.17) ROOF -CEILING CONSTRUCTION (Chapter 8) WOOD ROOF FRAMING (R802) Fire -retardant -treated wood (R802.1.5) Framing details (R802.3) Rafter ties (R802.3.1) Collar ties (4' o.c., in upper third of attic) (R802.3.1) Purlins (2" x 4" at 4' o.c. minimum) (Figure R802.5:1, R802.5.1) Bearing (R802.6) Cutting and notching (R802.7) X Engineered wood .products (R802.7.2) Lateral support and bridging (R802.8) Framing of openings (R802.9) X Wood trusses (R802.10) Roof tie -down (17802.11) CEILING JOISTS [Tables R802.4(1), R802.4(2)] X Without attic -storage, LL = 1Opsf X With attic storage LL = 20psf X Spacing Species and grade X Span I X Size RAFTERS [Tables R802.5.1(1) - R802.5.1(8)] Ground snow load/LL = 20 psf Controlling design (LL or snow) Ceiling not attached/ceiling attached) Spacing Species and grade Span Size Hc/HR; Adjustment factor ROOF SHEATHING (R803.2) Grade X Thickness FRTW allowable stresses/grading X Allowable spans [Table R503.2.1.1(1)] X Installation (R803.2.3) 91 ROOF -CEILING CONSTRUCTION (cont'd.) STEEL ROOF FRAMING (R804) Roof construction (R804.3) i General (R804.1) Roof tie -down (R804.3.8) Structural framing (R804.2) Material (R804.2.1) Corrosion protection (R804.2.2) Identification (R804.2.3) Fastening (R804.2.5) ROOF VENTILATION (R806) X Ventilation requirements (R806.1 - R806.5) ATTIC ACCESS (R807) X Access requirements (807.1) ROOF ASSEMBLIES (Chapter 9) ROOF CLASSIFICATION (R902) X ' Roof covering materials (R902.1) 1 WEATHER PROTECTION (13903) Flashing (R903.2) Coping (R903.3) i Roof drainage (R903.4) MATERIALS (R904) X Compatibility; specifications; physical charac- teristics; identification (R904.2 - R904.4) REQUIREMENTS FOR ROOF COVERINGS (R905) X Underlayment (R905.1.1, R905.1.2) X Asphalt shingles (R905.2) Clay and concrete tile (R905.3) Metal roof shingles (R905.4) i Mineral -surfaced roll roofing (R905.5) Slate shingles (R905.6) Wood shingles, (R905.7) Wood shakes (R905.8) i Built-up roofs (R905.9) NOA / PA Metal roof panels (R905.10) NOA / PA Modified bitumen roofing (R905.11) NOA / PA Thermoset single -ply roofing (R905.12) NOA / PA Thermoplastic single -ply roofing (R905.13) NOA / PA Sprayed polyurethane foam roofing (R905.14) NOA / PA Liquid -applied roofing (R905.15) NOA / PA Photovoltaic shingles (R905.16) ROOF INSULATION (R906) General (R906.1) ROOFTOP - MOUNTED PHOTOVOLTAIC SYSTEMS (R907) Materials and installation (R907.1 - R907.5) REROOFING (R908) Materials and methods (R908.1) Structural support (R908.2) Replacement/re-covering (R908.3, R908.4) ROOFTOP - MOUNTED PHOTOVOLTAIC PANEL SYSTEMS (R909) Materials and installation (R909.1 - R909.3) CHIMNEYS AND FIREPLACES (Chapter 10) MASONRY FIREPLACES (R1001) Hearth extension (R1001.9, R1001.10) Construction Fireplace clearance (R1001.11) (Figure R1001.1 and Table R1001.1) Fireblocking (R1001.12) SDC D reinforcing/anchorage (R1001.3 and R1001.4) MASONRY CHIMNEYS (111003) 1 Firebox walls and dimensions (R1001.5 and R1001.6) Steel fireplace units (R1001.5.1) Lintel (noncombustible) (R1001.7) I Construction (Table R1001.1, R1003.2, R1003.3, and Figure R1001.1) Corbeling (R1003.5) 0