HVAC Load Calculations
for
Express Homes
i
I, Z�vj%
EE-al ��
reRw
Prepared By:
Kristin Kelly
Florida Breeze
6928 Vickie Circle
West Melbourne
3219518767
Monday, July 9, 2018
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
i
---- -- -- -- - - _ ._._--------- ---- ------
r Rhvac - Residentlaf& Light Commercial HVAC Loads Elite Software Development, —Inc—.
f At Service Masters, Ll- _ Express 1.828 Cali Left St Lucie
E Palm Ba , FL 329R9
Y— _ _
�
-- _ Page
Pro ect ,Re ort
—
(-Gerieral Project Inf€imiation
Project Title:
Express 1828 Cali Left St Lucie
f Designed By:
Kristin Kelly
Project Date:
July 9, 2018
Client Name:
Express Homes
j Company Name:
Florida Breeze
Company Representative:
Kristin Kelly
Company Address:
6928 Vickie Circle
Company City:
West Melbourne
Company Phone:
3219518767
Reference City:
Fort Pierce, Florida
i Building Orientation:
Front door faces South
Daily Temperature Range:
Medium
i Latitude:
27 Degrees
Elevation:
25 ft.
Altitude Factor:
0.999
Outdoor Outdoor Outdoor Indoor Indoor Grains
Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference
Winter: 42 39.4
n/a
n/a 70 n/a
Summer: 90 78
59%
50% 75 61
Total Building Supply CFM: 968
CFM Per Square ft-. 0.529
Square ft. of Room Area: 1,828
Square ft. Per Ton: 689
Volume (ft'j: 15,721
Build h� Loads
i Total Heating Required Including Ventilation Air:
29,707
Btuh 29.707 MBH
Total Sensible Gain:
25,467
Btuh 80 %
Total Latent Gain:
6,390
Btuh 20 %
Total Cooling Required Including Ventilation Air:
i
31,858
Btuh 2.65 Tons (Based On Sensible + Latent)
Notes
-
-- F ,
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
All computed! results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
your design conditions.
C:\ -_.\EXPRESS 1828 CALI LEFT LUCIE 2018.rh9 Monday, July 9, 2018, 1:41 PM
r--
-.--------- ------------ ------------- -
- - - ..__—....
__._.._ ----
1 Rhwac Residential & Light Commercial HVAC
Loads
Elite Software Developmenfi; In
A/C:SAr ice'Wa to ts; LLC
Express 1828 Cali Leff St Lucie
Palm BaY FL 32909 '
Pa e
i
r-_...
Duct Size Preview
L_ — --- - -
- -Source
.Minimum ,
—9R-1
1
Room or
Duct Name
!
Mabmum Rough.]
Design! SP{
Duct Duct Hag CIg
Act Duct
______—
(
Vebcty� Vebc%y FacWj
U1001�Lossj
Vebcty LengthFlaa� Flow
Flaw ,_ Size _
System I
Supply Runouts
Zone 1 i
1-Wtxe House
Emit -'In
454 750 0.41
0.1
547.5 369 , 968 9-6
OtherDucts In Systeml
-- .
f
Supply Main Tank
Built -In
550 600 0.01
0.1.
547.5 369] Jam! 968 18
C:\ ...\EXPRESS 1828 CALI LEFT LUCIE 2018.rh9 Monday, July 9, 2018, 1:41 PM
RWac Resfdenira! & Light GamrnsKcial IiVAG Lads Elrte Soffwaie Development, lna'
A/C Service astersLLC' t Express 1828 Cats Left St Lucie;,;
I
Gompvnent_r rea. . ..... a
DescrNi�o u y ; '_ Quan Loss: ,{ Gain }Gain Gain's
2A-m-o: Glazing -Double pane low-e (e = 0.60), operable 124.8 1,400 0 2,288 2,288
window,) metal frame no break, u-value 0.4, SHGC
i 0.
-d: 2A-mGla ing-Double pane low-e (e = 0.60), sliding 40.8 697 0 665 665
glass door, metal frame no break, u-value 0.61,
SHGC 0.34
( 11 J: Door -Metal - Fiberglass Core 36.4 612 0 568 568
13AB-0fcs: Wall -Block, no blanket or board insulation, 1236.1 6,334 0 .3,936 3,936
filled core, siding finish
12C-Osw: Wpll-Frame, R-13 insulation in 2 x 4 stud 313.1 798 0 612 612
cavity, no board insulation'' -,siding finish, wood studs'
168-30: Roof/Ceiling-Under Attic with Insulation on Attic 1828 1,638 0 2,925 2,925
Floor (alto use for Knee Walls and Partition
Ceilings, Vented Attic, No Radiant Barrier, Dark
Asphalt Shingles or Dark Metal, Tar and Gravel or
Membrane, R-30 insulation
22A-pm: Floor -Slab on grade, No edge insulation, no 199 6,575 0 0 0
insulation below floor, any floor cover, passive, heavy
dry or Jiginsulation
wet soil
Subtotals for structure: 18,054 0 10,994 10,994
People: 5 1,000 1,150 2,150
Equipment: 850 4,000 4,850
�I Lighting: 0 0 0
l Ductwork: 8,589 2,365 8,469 10,825
Infiltration: Winter CFM: 100, Summer CFM: 52 3,064 2,175 864 3,039
Ventilation: )Winter CFM: 0, Summer CFM: 0 0 0 0 0
- - - -- - - - -------------- -- - -- - - - .- - --- .
System 1 L d Totals: 29'-707 6,390 25,467 31,858
Cherci4rE►giir, S =' . t Y' x ? > .� } z k , . p -__._..._.._.,.-.� _-_.__7
t Supply CFM:I - 968 CFM Per Square ft.: ___>__ . 0 529
Square ft. of Room Area: 1,828 Square ft. Per Ton: 689
Volume (ft3): 15,721
stemkLoads -- - 7VT
,
Total Heatind Required Including Ventilation Air: 29,707 Btuh 29',70'77 MBH
Total Sensible Gain: 25,467 Btuh 80 %
Total Latent Gain: 6,390 Btuh 20
Total Cooling Required Including Ventilation Air: 31,858 Btuh 2.65 Tons (Based On Sensible + Latent)
Rhvac is an F CCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
All computed �esults are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
your design conditions.
C:1... 1EXPRESS 1828 CALI LEFT LUCIE 2018.rh9 Monday, July 9, 2018, 1:41 PM
4 E hrac Residential& LightCommerciaYHYAC loads°
A/C Service Masters, 'LLC
LEgceipmaent Data - S
Cooling
Systeim Type:
j Outdoor Model:
i Indoor Model:
' Tradename:
I Outdoor Manufacturer:
Description:
AHRI ,Reference No.:
Capacity:
y Efficiency:
Heating
System Type:
Model.
Tradename:
Manufacturer:
Description:
Capacity:
Efficiency:
1
Air Source Heat Pump
25HBC536A*030*
FX4DN(B,F)037L
CARRIERAIR CONDITIONING
CARRIER AIR CONDITIONING
Air Source Heat Pump
9155179
36130
15 SEER
Air Source Heat Pump
25HBC536A*030*
CARRIER AIR CONDITIONING
CARRIER AIR CONDITIONING
Air Source Heat Pump
34600
8.5 HSPF
Express 1828 Cali Left St Lucie I
` Page 6
- _---- ----- --.: . ....... _ -- - ------ - ----
,
This system's equipment was selected in accordance with ACCA Manual S.
Manual 3 equipment sizing data: SODB: 90F, SOWS: 78F, WODB: 42F, SIDB: 75F, SIRH: 50%, WIDE: 70F, Sen. gain:
25,467 Btuh,, Lat. gain: 6,390 Btuh, Sen. loss: 29,707 Btuh, Entering clg, coil DB: 78.9F, Entering c1g. coil WB: 64,417,
Entering htg., coil DB: 66.7F, Clg. coil TD: 20F, Htg. coil TD: 70F, Req. clg. airflow: 968 CFM, Req. htg. airflow: 369 CFM
C:1... XEXPRESS 1828 CALI LEFT LUCIE 2018.rh9 Monday, July 9, 2018, 1:41 PM
dential Plans Examiner FWew Form
R-M_
for HVAC System Design (Lows, Equipment, Duds)
Contractor Florid
Mechanical License
Building Plan #
Home Address Strt
Breeze
# CAC1814113
County, Town, Municipality, Jurisdiction
Header Information
REQUIRED ATTACHMENTS'
Manual A Form (and supporting worksheets):
or MJ1AE Form (and supporting worksheets):
OEM performance data (heating, cooling, blower):
Manual D Friction Rate Worksheet:
Duct distribution system sketch:
or Lot#, Block, Subdivision)
Winter Design Conditions
Outdoor terjtperature
42
OF
indoor temperature
70
OF
Total heat loss
29707
Btu/h
Summer DeIsIign Conditions
Outdoor temperature
90
OF
Indoor templl rature
75
OF
Grains difference 61
Z� Gr @ 50
% Rh
Sensible heat gain
25467
Btu/h
Latent heat gain
6394
Btu/h
Total heat gain
3185$
Btu/h
Equipment type
Furnace. Heat pt.
Model
Heating output i
Heat pumps - cap
Heat pump
Boiler, etc.
25HBC536A*030*
city 34600 Btu/h
at winter design outdoor conditions
Auxiliary heat output capacity Btu/h
Form
RIPER 1.01
8Mar 10
ATTACHED
Yes ® No
Yes Q No ❑X
Yes ❑X No ❑
Yes ❑ No pQ
Yes ❑ No QX
Building Construction Information
Building
Orientation (Front door faces)
South
North, East, West- South, Northeast, Northwest, Southeast, Southwest
Number of bedrooms
4
Conditioned floor area
1828 Sq Ft
Number of occupants
5
Windows
Roof
Eave overhang depth
_2.7 Ft
Ee
Internal shade
EI
Blinds, drapes, etc
Depth Window
Number of skylights
0
Cooling Equipment Data
Equipment type
Heat pump
Air conditioner, Heat pump, etc
Model
25HBC536A*030*
Sensible cooling capacity
28919 Btu/h
Latent cooling capacity
7211 Btu/h
Total cooling capacity
36130 Btu/h
Blower Data
Heating CFM 121-83 CFM
Cooling CFM _121a CFM
Design airflow I
CFM
Longest supply duct:
Ft
Duct Materials Used (circle)
Trunk Duct: Duct board, Flex, Sheet metal,
Extemal Static Pressure (ESP)
IWC
Longest return duct:
Ft
Lined'sheet metal, Other (specify)
Component Pressure Losses (CPL)
IWC
Total Effective Length (TEL)
Ft
Branch Duct: Duct board, Flex, Sheet metal,
Available. Static Pressure (ASP)
IWC
Friction Rate:
We
Lined sheet metal, Other (specify)
ASP = ESP - CPL
Friction Rate = (ASP x 100) +TEL
Contractor's Prin ed Name Kristin Kelly Date 7/9/2018
Contractor's Signature
�� ���� �wwa uen yisurduun to accept Kequirea Attacnments pnnted from approved ACCA software vendors, see list on page 2 of instructions,
' If abridged version of Manual J Is used for load calculation, then verify residence meets requirements, see Abridged Edition Checklist on page 13 of instructions.
Form generated by ACCAapproved Manual J Eighth Edition Version 2 Elite Software Rhvac program.
-Air Conditioning Contractors of America
Manual S iResidentiaf Equipment Selection)
- Project In. "ation
Name:
City:
Stater I Altitude: �� Altitude Adjustment: 1.00
Manual J'Load Calculations
Total Load Sensible
31858 25467
OEM Infon
Cooling Oesign; Information
Outdoor Design Temp: 91 °F db Summer
Outdoor Design Temp: 43 -F db tWnnter
Indoor Design Temp: 75 °F db 50 %RH 63 °F wb
Latent SHR Heat Loss
6391 0.799
7-1
Airflow Calculations -
Design TD for Airflow
19
Design Sensible CFM
F12191
Manufacturer:
lCarriet
Furnace Model #:
AFUE;�
Coil or Fan-
oil Model #: FX4DN(f3,F)037L I Condenser Model #: 25HBC536A*030*
SEER 15.0 HSPF:
8.50
(A) Manufa hirers
Cooling Performance Data
Lower
Return Air
Outdoor Temperature =
95 (F db)
En
ering Coil Temperature = 75 (F db)
CFM
(F wb)
Total BTUH
Sensible BTUH
Latent BTUH
SHR
Rated
CFM @ Rated RA Temperature
65
38.370
25,600
12,770
0,6672
Rated
CFM @ Design RA Temperature
1050
63
357946
27,536
8,410
0.766
Raed
i
CFM @Rated RA Temperature
60
32,310
30,440
1,870
0.9421
(B) ManufactLrees
Cooling Performance Data
Higher
Return Air
Outdoor
Temperature =
95 (F db)
Entering
Coil Temperature = 75 (F db)
CFM
(F wb)
Total BTUH
Sensible BTUH
Latent BTUH
SHR
Rat
l d CFM @ Rated RA Temperature
65
377470
28,000
F-9—.4-761
10,7473
Rated
CFM @ Design RA Temperature
1 1550
63 1
r-3-674-9-2--l29,204
77288 7
0.8003
Rated
CFM @Rated RA Temperature
60
35,025
31,010
4,015
0.8854
Manufacturer's Cooling Performance Data (Interpolated)
li
Design
Return Air
Outdoor Temperature = 95 (F db)
CFM
(F wb)
Total BTUH
Sensible BTUH
Latent BTUH
SHR
28098
8,032
0,7777
Exc�ss Latent Capacity Calculation
+ 820
- 82-
Capacity @ Design CFM / RA (F wb)
1218.5
63
36,130
28,919
F-T.-2-117-1
I 0.800
Equipment Capacity as a % of Design
1 11-34-1-T.1
113.553
F 112-.84%
Manufacturer's
Heat Pump Data
Capacity
Capacity.
Balance
Supplemental
@ 47 °F db @ 17 °F db Point
34,800 18,820 -18.3
Heat Required
-15.87
Manufacturer'slFumace
I
Data
Input
Output
Desired
Calculated