HomeMy WebLinkAboutWIND LOAD COMPLIANCE CERTIFICATIONST. LUCIE COUNTY J'0111 DEPARTMENT OF GOMMUNITY DEVELOPMENT 2300 VIRGINIA AVENUE, ROOM 201 FT. PIERCE, FL. 34982-5652 407-462-1553 DESIGN CERTIFICATION FOR WIND LOAD COMPLIANCE This Certification is to be completed by the project design architect or engineer. This Certification must be submitted with all applications 'for building permit involving the construction of new residence (single or multifamily), residential addition, any accessory structure requiring a building permit, and any nonresidential structure. This Certification shall not apply to interior renovations (provided that no strudural walls, columns or other similar component is being effected) and certain other minor building permits. For further assistance, please Contact the Building Inspection Office at 462-1553 or 462-2172. PROJECT NAME °„ <i STREET ADDRESS PR NUMBER PERMIT NUMBER OCCP. TYPE CST_ TYPE CERTIFICATION STATEMENT: I CERTIFY THAT, TO Ti-iE BEST OF MY KNOWLEDGE AND BELIEF, THESE PLANS AND SPECIFICATIONS HAVE BEEN DESIGNED TO COMPLY WITH THE APPLICABLE STRUCTURAL PORTION OFTHE BUILDING CODES CURRENTLY ADOPTED AND ENFORCED BY ST. LUCIE COUNTY. I ALSO CERTIFY THAT STRUCTURAL ELEMENTS DEPICTED ON THESE PLANS PROVIDE ADEQUATE RESISTANCE TO THE WIND LOADS AND FORCES SPECIFIED BY CURRENT CODE PROVISIONS. d DESIGN PARAMETERS AND ASSUMPTIONS USED: (pleasa c!>et or completa the appropriate box) 1. BUILDING CODE EDITION USED (YEAR) a SBCCI ASCE 7-88 OTHER (SPECIFY) 11. BUILD114G DESIGN IS (CHECK ONE) ENCLOSED J PARTIALLY ENCLOSED OPEN BUILDING ! 6U1I,DING HEIGHP. L z s�}(i�2 FT 4. VIAND SPEED USED IN BUILDING DESIGN: MPH WIND EXPOSURE CLASSIFICATION (RERR TO EXPOS RIE TABLES IN au-ciING cME IDENMM IN UNE #1): 1-6,4 5 AVERAGE WIND VELOCITY PRESSURE ON EXTERIOR FACES OF STRUCTURE: Z 5 PSF PEAK WIND VELOCITY PRESSURE ON EXIER10R FACES OF STRUCTURE: 1�5 S PSF IMPORTANCEUSE FACTOR (0gnWN FROM aufLDiNG COOS; LOADS: FLOOR PSF ROOFIDEAD: 1-7 PSF ROOF/LIVE: 3 P5F WEREr SHEAR WALLS CONSIDERED FOR STRUCTURE (cmEcK 0#,e) • YE$ "' NO If NO, why? (attach IS A CONTINUOUS LOAD PATH PROVIDED (CHECK, okte) YES NO tf NO, why? (attach explanation) �"" 12. ARE COMPONENT AND CLADDING DETAILS PROVIDED (CHECK o"t YES NO If NO, whY7 (attach expra (nation) 13. MININ UM SOIL BEARING PRESSURE: Su'V PSF AS WITNESSED BY MY SEAL, I HEREBY CERTIFY THAT THE INFORMATION' INCLUDE_ D;.:— TH ° THIS CERTIFICATION IS TRUE AND CORRECT, TO THE BEST OF MY KNOWLEDGE AND 13ELI1E NAME: _ /4'� TLl�/ /,A/� CERTIFICATION NO: jJ HER DESIGN FIRM: DATE • cmzo-oo ------------------------------------------------/-