Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM 60OA-97 FLORIDA ENERGY EFFICIENCY -CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs.. Residential Whole Building Performance Method A Project Name: BIMINI 1217 Builder': PRL PROPERTIES P Address:1 Permitting Office: City, State: ,. Permit Number: Owner: Jurisdiction Number: �' Climate Zone: Central r 1. New construction or existing 2. Single family or multi -family 3. Number of units, if multi=family 4. Number of Bedrooms 5. Is this la worst case? 6. Conditioned floor area (ft2) 7. Glass area & type a. Clear , single pane b. Clear - double pane c. Tint/other SC/SHGC - single pane d. Tint/other SC/SHGC - double pane 8. Floor types a. Slab -On -Grade Edge Insulation b. N/A c. N/A 9. Wall types a. Concrete, Int Insul, Exterior b. Frame; Wood, Adjacent c. N/A d. N/A e. N/A 10. Ceiling types a. Under Attic b. Under Attic c. N/A 11. Ducts; a. Sup: Unc. Ret: Unc. AH: Garage b. N/A New _ 12. Cooling systems Single family _ a. Central Unit. Cap: 34.0 kBtu/hr 1 _ SEER:10.00 3 ^_ b. N/A . Yes _ 1217 ft2 c. N/A ` 0.0 ft2. _ 13: Heating systems 0.0 ft2 _ a. Electric'1-Teat Pump Cap: 34.0 kBtu/hr _ 132.0 112 HSPF: 6.80 _ 0.0 ft2 U. N/A R=0.0, 160.0(p) ft _ c. N/A 14. Hot water systems _ a. Electric Resistance Cap: 40.0 gallons _ R=4.2, 1000.0 W _ 4 EF: 0.94 _ R=11.0, 155.0 ft2 _ b. N/A c. Conservation credits _ (HR-Heat recovery, Solar DHP-Dedicated heat pump) R=19.0, 740.0 ft2 _ 15. HVAC credits R=19.0, 538.0 ft2 _ (CF-Ceiling fan, CV -Cross ventilation, HF-Whole house fan, _ PT -Programmable Thermostat, Sup. R=6.0, 67.0 ft _ RB-Attic radiant barrier, MZ-C-Multizone cooling, MZ-H-Multizone heating) Glass/Floor Area: 0.11 Total as -built points: 18006.00 PASS Total base points: 20268.00 I hereby certify that -the plans and specifications:covered by this calculation are in compliance with the Florida Energy Code. PREPARED BY:,. ' DATE S I hereby certify that this building; -as designed, is in compliance with the Florida EnergyCode. OWNER/AGENT:, DATE: Review of the plans and T1iE sT specifications covered by this calculation indicates compliance with the Florida Energy Code. . Before construction is completed - - a this building will be inspected for compliance with Section 553.908 �•1. y`t Florida Statutes. cOD� BUILDING OFFICIAL: DATE: EnergyGaugeV(Version: FLRCNA-200) FORM, 600A-SI SUMMER CALCULATIONS �Res-idential Whole Building Performance Method. A - Detai,ls' ADDRESS: poll PERMIT #:.....,. BASE ' -AS-BUILT :. GLASS TYPES .18 X. Conditioned X BSPM = -Points ;:, ; ,_ Overhang, Floor Area Type%yc Ornt`''Len " .;Area : 'H gj X, SPM -X. SOF = Points .18 1217.0 42.08 9217.6 '-Sirigl@, Ttnb,, " We 2.0 4.5, . 49.0• 44.87 .0.77 660.2 Single, Tint ; W ' 2.0 `.'`' 5:5 • r .. 32.0 '44.87 0.83 1193.4 , Single, Tint , S 2�0 ' 3.5 5:0 ti. 37.29 0.66 123.6 Single, Tint E 2.0. 4:5., 1-3:0 :. 49.89 0.77 501•.8 Single, Tint .'' E,-, 2.0 1-,T0 `r%',;40.0•: 49.89 0.89 1777.8 Single,, Tint E,., 2.0.. ' 3.5'-•: �10:0 49.89 0.69 345.3 Single, Tint E :' 2.0 4.5 13.0 49.89 0.77 501.8 As -Built Total: 132:0 6103.9 WALL TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Adajcent 155.0 0.7 108.5 Concrete, Int Insul, Exterior 4.2 1000.0 1.16 1160.0 Exterior 1000.0 1.90 1900.0 Frame, Wood, Adjacent 11.0 -155.0, 0.70 108.5 Base Total 1155.0' 2008.6 As -Built Total: 1155.0 1268.6 DOOR TYPES Area X • BSPM = Point$ '. Type Area X SPM = Points. Adjacent -17.0 1.60 27.2f Exterior Wood 20.0 7.20 144.0 Exterior 20.0. 4.80 96.0. Adjacent Wood 17.0 2.40 40.8 Total: 37.0 123.2 ' As -Built Total: 37.0 184.8 LBase ILING TYPES Area X BSPM = Points Type -Value Area X SPM = Points Urider Attic 1217.0 0.60 ' 730.2 ' Under Attic 19.0, 740.0 1,10 814.0 Under Attic . 19.0 538.0 1.10 591.8 Base Total:-1217.0 730.2 As -Built Total: 1278.0 1405.8 FLOOR.TYPES; Area X BSPM':­ Points' - Type R-Value Area X SPM = Points Slab 166:0(p) ­' -31.8 -5088.0. Slab -On -Grade Edge Insulation 0.0 160.0(p) -31.90 -5104.0 Raised 0.0." 0.00 0.0 1,,.. Base Total: >• -5088.0 As -Built Total: 1 .5104.0 -INFILTRbTION .Area X Points " Area'X SPM = Points ,'BSPM 1217.0 14.31-• . 17415.3 ;'� 1217.0 14.31 17415.3 i FORM 600A-97 '! SUMMER _CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: , ,. PERMIT #: ._BASE:: t.:. '' ..: ;-, _ AS -BUILT Summer 13_aSe~Poi nts: 244063 Summ' 'e'r As -Built Points: 20274.3 Total Simmer X`'*ste Cooli_rg_,..- r . T.otav, " X -bap' X Duct X System X Credit' = Cooling PGirtts"_-,_Multiplier--­-`°`' Points Component Ratio . Multiplier' —Multiplier Multiplier Points �0274 3 1.000" 1.048 0.341 1.000.. 7245.4 24406.7 ::. 3 4; �'8730 3 , Qa74 3-...1.00 1.048 0.341 1.000 7245.4 EnergyGaugeTm DCA Form 60OA-97 EnergyGaugeWlaRES'97 FLRCNA-200 FORM 6;OOA-97 WINTER CALCULATIONS esilentiaa Whole Building Performance Method A - Details ADDRESS:':,`, r PERMIT #: I a BASE AS -BUILT CLASS TYPES X Conditioned• k BWPM _ . Points Overhang Floor Area-, ' ": Type/9C Ornt Len Hgt ,Area X WPM X WOF = Points 18 1217 0 ` A:75 1049.2 Single, Tint W 2.0 4:5 19.0 11.21 1.04 220.8 .,•... r Single, Tint W 2.0 5.5.. 32.0 11.21 1.03 368:0 Single, Tint S ,2.0 : 3.5 5.0 8.59 1.39 59.7 - Single, Tint E 2.0 4.5 13.0 10.54 1.05 143.8 Single, Tint E 2.0 ' 7.0 40.0 10.54 1.02 431.0 Single, Tint E 2.0 3.5 10.0 10.54 1.08 113.4 i Single, Tint E 2.0 4.5 13.0 10,54 1,05 143.8 As -Built Total: 132.0 1480.5 'WALL TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Adajcent 155.0 ,, 1.8 279.0 Concrete, Int Insul, Exterior 4.2 1000.0 3.26 3260.0 Exterior 1000.0 2.00 2000.0 Frame, Wood, Adjacent 11.0 155.0 1.80 279.0 i Base Total: 1166.0 2279.0- As -Built Total: 1166.0 .3539.0 i DOOR TYPES Area X BWPM = Points Type Area X, WPM = Points Adjacent 17.0 4.00 68.0 Exterior Wood 20.0 7.60 152.0 Exterior 20.0 5.10 10.2.0 Adjacent Wood :.17.0 5.90 100.3 Base Total, 37.0 170.0., 'As -Built Total: ,37.0 252.3 CEILING TYPESArea X BWPM = Points Type R-Value ::Area . X WPM = Points Under Attic 1217.0 0.60 .730.2 Under Attic 19.0 740.0 1.00 740.0 Under Attic 19:0. - : 538.0 1.00 538.0 Base Total: 1217.0 730.2 As -Built Total: `1278..0 �;. 1278.0 i FLOOR TYPES Area X BWPM = Points Type R-Value Area X WPM ' _ 'Points Slab 160.0(p) -1.9 -304.0 Slab -On -Grade Edge Insulation 0.0 .160.0(p) r `. 2.50 400.0 " Raised 0.0 0.00 0.0 - Base Total: -304.0 As -Built Total: 400.0 INFILTRATION Area X BWPM = Points ;. Area V1/PM = Points: , 1217.0 -0.28 -340.8 = 1217.0 ! -0.28 -340:8 EnergyGauge® DCA Form 60OA-97 I t FORM 60OA-97 WINTER' CAL CU LATI®NS Residential Whole Building Performance Method A - Details I ADDRESS: , , , PERMIT #: Y . BASE AS -BUILT Winter) Base Points: 3583.6 Winter As -Built Points: 6609.0 Total Winter X System = Heating Total X cap, X Duct X .System X Credit = Heating Points Multiplier Points Component Ratio Multiplier Multiplier . Multiplier Points 6609.0 1.000 1.073 0.502 1.000 3559.3 3583.6 1.0730 3845.2 6609.0 • 1.00 1.073 0.502 1.000 3559.3 EnergyGaugeTM DCA Form 60OA-97 EnergyGauge®/FIaRES'97 FLRCNA-200 FORM 60OA-97 WATER HEATING & CODE COMPLIANCE STATUS Residential Whole Building Performance Method A - Details ADDRESS: , , PERMIT #: BASE AS -BUILT WATER HEATING Number of X Multiplier = Total Tank EF Number of X Tank X Multiplier X Credit = Total Bedrooms Volume Bedrooms Ratio Multiplier 3 2564.00 7692.0 40.0 0.94 3 1.00 2400.34 1.00 7201.0 As -Built Total: 7201.0 CODE COMPLIANCE STATUS BASE AS -BUILT Cooling + Heating + Points Points Hot Water Points = Total Points Cooling Points + Heating + Hot Water = Total,. . Points Points Points. 8730.3 3845.2 7692.0 20267.5 7245.4 3559.3 7201.0 181005.7 PASS. 5�41,_ . cG ,ihll�• --- � EnergyGaugeTM DCA Form 60OA-97 EnergyGauge®/FIaRES'97 FL•RCNA-200 FORM 60OA-97 - Code Compliance Checklist Residential Whole Building Performance Method A - Details ADDRESS: , , , .. PERMIT #: I 6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK Exterior Windows &Doors 606.1.ABC.1.1 Maximum:.3 cfm/s .ft. window area• .5 cfm/s .ft. door area. Exterior & Adjacent Walls 506.1.ABC.1.2.1 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility penetrations; between wall panels & top/bottom plates; between walls and floor. EXCEPTION: Frame walls where a continuous infiltratior barrier is installed that extends from and is sealed to the foundation to the top plate. Floors 606.1.ABC.1.2.2 Penetrations/openings >1 /8"sealed, unless backed by truss or joint members. EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed to the perimeter, penetrations and seams. Ceilings 606.1.ABC.1.2.3 Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases, soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is installed that is sealed at the perimeter, at penetrations and seams. Recessed Lighting Fixtures 606.1:ABC.1.2.4 Type IC rated with no penetrations, sealed; or Type IC or non -IC rated, installed inside a sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from conditioned space, tested. Multi -story Houses 606.1.ABC.1.2.5 Air barrier on perimeter of floor cavity between floors. Additional Infiltration reqts 606.1.ABC.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, have combustion air. Aft-99 nTNFR PRFSrRIPTIVF MFASI IRF14 /mnct ha mpt nr Pyrpprlpri by all racirlanrac 1 COMPONENTS SECTION REQUIREMENTS CHECK Water Heaters 612.1 Comply with efficiency requirements in Table 6-12. Switch or clearly marked circuit breaker electric or cutoff as must be provided. External or built-in heat trap required; Swimming Pools & Spas 612.1 Spas & heated pools must have covers (except solar heated). Non-commercial poQIs must have a pump timer. Gas spa & pool heaters must have a minimum thermal efficiency of 78%. Shower heads 612.1 Water flow must be restricted to no more than 2.5_gallons per minute at 80 PSIG. Air Distribution Systems 610.1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, insulated, and installed in accordance with the criteria of Section 610. Ducts in unconditioned attics: R-6 min. insulation. HVAC Controls 607.1 .. Separate readily accessible manual or automatic thermostat for each system. Insulation 604.1., 602.1. ...:....... Ceilings-Min..R-19. Common walls -Frame R-11 or CBS R-3 both sides. - Common ceiling & floors R-11. EnergyGaugleTM DCA Form 60OA-97 EnergyGauge®/FIaRES'97 FLRCNA-200 ,ENERGY PERFORMANCE LEVEL, (EPIC) DISPLAY -CARD ESTIMATED ENERGY PERFORMANCE SCORE*. 82.4- The higher the score, the more efficient the home. 1. New construction or existing 2. Single family or multi -family 3. Number of units, if multi -family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft2) 7. Glass area & type a. Clear - single pane b. Clear - idoublepane c. Tint/other SC/SHGC - single pane d. Tintlother SC/SHGC - double pane 8. Floor types a. Slab -On -Grade Edge Insulation b. N/A c. N/A 9. Wall types a. Concrete, Int Insul, Exterior b. Frame, Wood, Adjacent c. N/A d. N/A e. N/A 10. Ceiling types a. Under Attic b. Under Attic c. N/A 11. Ducts a. Sup: Unic. Ret: Unc. AH: Garage b. N/A New _ 12. Cooling systems Single family ._ a. Central Unit 1 _ - 3 _ b. N/A Yes _ 1217 ft2 c. N/A' 0.0 ft2 _ 13. Heating systems 0.0 ft2 _ a. Electric Heat Pump 132.0 ft2 _ 0.0 ft2 b. N/A R=0.0, 160.0(p) ft R=4.2, 1000.0 ft2 _ R=11.0, 1.55.0 ft2 R=19.0, 740.0 f12 _ R=19.0, 538.0 ft2 Sup. R=6.0, 67.0 ft c. N/A 14. Hot water systems a. Electric Resistance b. N/A c. Conservation credits (HR-Heat recovery, Solar DHP-Dedicated heat pump) 15. HVAC credits (CF-Ceiling fan, CV -Cross ventilation,. HF-Whole house fan, PT -Programmable Thermostat, RB-Attic radiant barrier, MZ-C-Multizone cooling, MZ-H-Multizone heating) I certify that this home has complied with the Florida Energy Efficiency Code For Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Address of New Home: Date: City/FL Zip: il• Cap: 34.0 kBtd/hr _ SEER: 10.00 Cap: 34.0 kBtu/hr _ HSPF: 6.80 Cap: 40.0 gallons _ EF: 0.94 *NOTE: The homd's estimated energy performance score is only available through the FLARES computer program. This is not a Building Energy Rating. If your score is 80 or greater (or 86 for a US EPA/DOE EnergyStar designation), your home may qualify for energy efficiency mortgage (EEM) incentives if you obtain a Florida Energy Gauge Rating. Contact the Energy Gauge Hotline at 4071638-1492 or see the Energy Gauge web site at www.fsec.ucf edu for information land a list of certified Raters. For information about Florida's Energy Efficiency Code For Building Construction, contact the Department of Community Affairs at 8501487-1824. EnergyGauge® (Version: FLRCNA-200)