HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM 60OA-97
FLORIDA ENERGY EFFICIENCY -CODE
FOR BUILDING CONSTRUCTION
Florida Department of Community Affairs..
Residential Whole Building Performance Method A
Project Name: BIMINI 1217 Builder': PRL PROPERTIES P
Address:1 Permitting Office:
City, State: ,. Permit Number:
Owner: Jurisdiction Number: �'
Climate Zone: Central r
1. New construction or existing
2. Single family or multi -family
3. Number of units, if multi=family
4. Number of Bedrooms
5. Is this la worst case?
6. Conditioned floor area (ft2)
7. Glass area & type
a. Clear , single pane
b. Clear - double pane
c. Tint/other SC/SHGC - single pane
d. Tint/other SC/SHGC - double pane
8. Floor types
a. Slab -On -Grade Edge Insulation
b. N/A
c. N/A
9. Wall types
a. Concrete, Int Insul, Exterior
b. Frame; Wood, Adjacent
c. N/A
d. N/A
e. N/A
10. Ceiling types
a. Under Attic
b. Under Attic
c. N/A
11. Ducts;
a. Sup: Unc. Ret: Unc. AH: Garage
b. N/A
New _
12. Cooling systems
Single family _
a. Central Unit.
Cap: 34.0 kBtu/hr
1 _
SEER:10.00
3
^_
b. N/A .
Yes
_
1217 ft2
c. N/A `
0.0 ft2. _
13: Heating systems
0.0 ft2 _
a. Electric'1-Teat Pump
Cap: 34.0 kBtu/hr _
132.0 112
HSPF: 6.80 _
0.0 ft2
U. N/A
R=0.0, 160.0(p) ft _
c. N/A
14. Hot water systems
_
a. Electric Resistance
Cap: 40.0 gallons _
R=4.2, 1000.0 W _
4
EF: 0.94 _
R=11.0, 155.0 ft2 _
b. N/A
c. Conservation credits
_
(HR-Heat recovery, Solar
DHP-Dedicated heat pump)
R=19.0, 740.0 ft2 _
15. HVAC credits
R=19.0, 538.0 ft2 _
(CF-Ceiling fan, CV -Cross ventilation,
HF-Whole house fan,
_
PT -Programmable Thermostat,
Sup. R=6.0, 67.0 ft _
RB-Attic radiant barrier,
MZ-C-Multizone cooling,
MZ-H-Multizone heating)
Glass/Floor Area: 0.11 Total as -built points: 18006.00 PASS
Total base points: 20268.00
I hereby certify that -the plans and specifications:covered
by this calculation are in compliance with the Florida
Energy Code.
PREPARED BY:,. '
DATE S
I hereby certify that this building; -as designed, is in
compliance with the Florida EnergyCode.
OWNER/AGENT:,
DATE:
Review of the plans and T1iE sT
specifications covered by this
calculation indicates compliance
with the Florida Energy Code. .
Before construction is completed - - a
this building will be inspected for
compliance with Section 553.908 �•1. y`t
Florida Statutes. cOD�
BUILDING OFFICIAL:
DATE:
EnergyGaugeV(Version: FLRCNA-200)
FORM, 600A-SI
SUMMER CALCULATIONS
�Res-idential Whole Building Performance Method. A - Detai,ls'
ADDRESS: poll PERMIT #:.....,.
BASE
' -AS-BUILT
:.
GLASS
TYPES
.18 X.
Conditioned X BSPM
= -Points
;:, ; ,_
Overhang,
Floor Area
Type%yc Ornt`''Len
" .;Area :
'H gj
X, SPM -X. SOF =
Points
.18 1217.0 42.08
9217.6
'-Sirigl@, Ttnb,, " We
2.0
4.5, . 49.0•
44.87
.0.77
660.2
Single, Tint ; W '
2.0 `.'`'
5:5 • r .. 32.0
'44.87
0.83
1193.4
,
Single, Tint , S
2�0 '
3.5 5:0
ti. 37.29
0.66
123.6
Single, Tint E
2.0.
4:5., 1-3:0
:. 49.89
0.77
501•.8
Single, Tint .'' E,-,
2.0 1-,T0
`r%',;40.0•:
49.89
0.89
1777.8
Single,, Tint E,.,
2.0.. '
3.5'-•: �10:0
49.89
0.69
345.3
Single, Tint E :'
2.0
4.5 13.0
49.89
0.77
501.8
As -Built Total:
132:0
6103.9
WALL TYPES Area X
BSPM
= Points
Type
R-Value
Area X
SPM =
Points
Adajcent 155.0
0.7
108.5
Concrete, Int Insul, Exterior
4.2
1000.0
1.16
1160.0
Exterior 1000.0
1.90
1900.0
Frame, Wood, Adjacent
11.0
-155.0,
0.70
108.5
Base Total 1155.0'
2008.6
As -Built Total:
1155.0
1268.6
DOOR TYPES Area X • BSPM
= Point$ '.
Type
Area X
SPM =
Points.
Adjacent -17.0
1.60
27.2f
Exterior Wood
20.0
7.20
144.0
Exterior 20.0.
4.80
96.0.
Adjacent Wood
17.0
2.40
40.8
Total: 37.0
123.2
' As -Built Total:
37.0
184.8
LBase
ILING
TYPES Area X
BSPM
= Points
Type
-Value
Area X
SPM =
Points
Urider Attic 1217.0
0.60
' 730.2 '
Under Attic
19.0,
740.0
1,10
814.0
Under Attic .
19.0
538.0
1.10
591.8
Base Total:-1217.0
730.2
As -Built Total:
1278.0
1405.8
FLOOR.TYPES; Area X
BSPM':
Points'
- Type
R-Value
Area X
SPM =
Points
Slab 166:0(p) '
-31.8
-5088.0.
Slab -On -Grade Edge Insulation
0.0
160.0(p)
-31.90
-5104.0
Raised 0.0."
0.00
0.0
1,,..
Base Total: >•
-5088.0
As -Built Total:
1
.5104.0
-INFILTRbTION
.Area X
Points "
Area'X
SPM =
Points
,'BSPM
1217.0
14.31-• .
17415.3
;'�
1217.0
14.31
17415.3
i
FORM 600A-97
'! SUMMER _CALCULATIONS
Residential Whole Building Performance Method A - Details
ADDRESS: , ,. PERMIT #:
._BASE::
t.:.
'' ..:
;-, _
AS -BUILT
Summer 13_aSe~Poi nts:
244063
Summ' 'e'r As -Built Points:
20274.3
Total Simmer X`'*ste
Cooli_rg_,..-
r
. T.otav, " X
-bap'
X Duct X System X
Credit'
= Cooling
PGirtts"_-,_Multiplier---`°`' Points
Component
Ratio
. Multiplier' —Multiplier
Multiplier
Points
�0274 3
1.000"
1.048 0.341
1.000..
7245.4
24406.7 ::. 3 4;
�'8730 3 ,
Qa74 3-...1.00
1.048 0.341
1.000
7245.4
EnergyGaugeTm DCA Form 60OA-97
EnergyGaugeWlaRES'97 FLRCNA-200
FORM 6;OOA-97
WINTER CALCULATIONS
esilentiaa Whole Building Performance Method A - Details
ADDRESS:':,`, r PERMIT #:
I a BASE
AS -BUILT
CLASS TYPES
X Conditioned• k
BWPM _
. Points
Overhang
Floor Area-, '
":
Type/9C
Ornt Len
Hgt ,Area X
WPM X
WOF
= Points
18 1217 0 `
A:75
1049.2
Single, Tint
W 2.0
4:5 19.0
11.21
1.04
220.8
.,•...
r
Single, Tint
W 2.0
5.5.. 32.0
11.21
1.03
368:0
Single, Tint
S ,2.0 :
3.5 5.0
8.59
1.39
59.7
-
Single, Tint
E 2.0
4.5 13.0
10.54
1.05
143.8
Single, Tint
E 2.0 '
7.0 40.0
10.54
1.02
431.0
Single, Tint
E 2.0
3.5 10.0
10.54
1.08
113.4
i
Single, Tint
E 2.0
4.5 13.0
10,54
1,05
143.8
As -Built Total:
132.0
1480.5
'WALL TYPES Area X
BWPM
= Points
Type
R-Value
Area X
WPM =
Points
Adajcent 155.0
,, 1.8
279.0
Concrete, Int Insul, Exterior
4.2
1000.0
3.26
3260.0
Exterior 1000.0
2.00
2000.0
Frame, Wood, Adjacent
11.0
155.0
1.80
279.0
i
Base Total: 1166.0
2279.0-
As -Built Total:
1166.0
.3539.0
i
DOOR TYPES Area X
BWPM
= Points
Type
Area X, WPM =
Points
Adjacent 17.0
4.00
68.0
Exterior Wood
20.0
7.60
152.0
Exterior 20.0
5.10
10.2.0
Adjacent Wood
:.17.0
5.90
100.3
Base Total, 37.0
170.0.,
'As -Built Total:
,37.0
252.3
CEILING
TYPESArea X
BWPM
= Points
Type
R-Value
::Area . X
WPM =
Points
Under Attic 1217.0
0.60
.730.2
Under Attic
19.0
740.0
1.00
740.0
Under Attic
19:0. -
: 538.0
1.00
538.0
Base Total: 1217.0
730.2
As -Built Total:
`1278..0 �;.
1278.0
i
FLOOR TYPES Area X
BWPM =
Points
Type
R-Value
Area X
WPM ' _
'Points
Slab 160.0(p)
-1.9
-304.0
Slab -On -Grade Edge Insulation
0.0
.160.0(p) r `.
2.50
400.0 "
Raised 0.0
0.00
0.0
-
Base Total:
-304.0
As -Built Total:
400.0
INFILTRATION Area X
BWPM =
Points
;.
Area
V1/PM =
Points: ,
1217.0
-0.28
-340.8
=
1217.0
! -0.28
-340:8
EnergyGauge® DCA Form 60OA-97
I
t
FORM 60OA-97
WINTER' CAL CU LATI®NS
Residential Whole Building Performance Method A - Details
I ADDRESS: , , , PERMIT #:
Y .
BASE AS -BUILT
Winter) Base Points:
3583.6
Winter As -Built Points:
6609.0
Total Winter X System =
Heating
Total X
cap, X
Duct X .System X
Credit
= Heating
Points Multiplier
Points
Component
Ratio
Multiplier Multiplier .
Multiplier
Points
6609.0
1.000
1.073 0.502
1.000
3559.3
3583.6 1.0730
3845.2
6609.0 •
1.00
1.073 0.502
1.000
3559.3
EnergyGaugeTM DCA Form 60OA-97 EnergyGauge®/FIaRES'97 FLRCNA-200
FORM 60OA-97
WATER HEATING & CODE COMPLIANCE STATUS
Residential Whole Building Performance Method A - Details
ADDRESS: , , PERMIT #:
BASE AS -BUILT
WATER HEATING
Number of X Multiplier = Total Tank EF Number of X Tank X Multiplier X Credit = Total
Bedrooms Volume Bedrooms Ratio Multiplier
3 2564.00 7692.0 40.0 0.94 3 1.00 2400.34 1.00 7201.0
As -Built Total: 7201.0
CODE
COMPLIANCE
STATUS
BASE
AS -BUILT
Cooling + Heating +
Points Points
Hot Water
Points
= Total
Points
Cooling
Points
+ Heating + Hot Water = Total,. .
Points Points Points.
8730.3 3845.2
7692.0
20267.5
7245.4
3559.3 7201.0 181005.7
PASS.
5�41,_ .
cG ,ihll�• --- �
EnergyGaugeTM DCA Form 60OA-97
EnergyGauge®/FIaRES'97 FL•RCNA-200
FORM 60OA-97
- Code Compliance Checklist
Residential Whole Building Performance Method A - Details
ADDRESS: , , , .. PERMIT #:
I
6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST
COMPONENTS
SECTION
REQUIREMENTS FOR EACH PRACTICE
CHECK
Exterior Windows &Doors
606.1.ABC.1.1
Maximum:.3 cfm/s .ft. window area• .5 cfm/s .ft. door area.
Exterior & Adjacent Walls
506.1.ABC.1.2.1
Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall;
foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility
penetrations; between wall panels & top/bottom plates; between walls and floor.
EXCEPTION: Frame walls where a continuous infiltratior barrier is installed that extends
from and is sealed to the foundation to the top plate.
Floors
606.1.ABC.1.2.2
Penetrations/openings >1 /8"sealed, unless backed by truss or joint members.
EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed
to the perimeter, penetrations and seams.
Ceilings
606.1.ABC.1.2.3
Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases,
soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate;
attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is
installed that is sealed at the perimeter, at penetrations and seams.
Recessed Lighting Fixtures
606.1:ABC.1.2.4
Type IC rated with no penetrations, sealed; or Type IC or non -IC rated, installed inside a
sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from
conditioned space, tested.
Multi -story Houses
606.1.ABC.1.2.5
Air barrier on perimeter of floor cavity between floors.
Additional Infiltration reqts
606.1.ABC.1.3
Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA,
have combustion air.
Aft-99 nTNFR PRFSrRIPTIVF MFASI IRF14 /mnct ha mpt nr Pyrpprlpri by all racirlanrac 1
COMPONENTS
SECTION
REQUIREMENTS
CHECK
Water Heaters
612.1
Comply with efficiency requirements in Table 6-12. Switch or clearly marked circuit
breaker electric or cutoff as must be provided. External or built-in heat trap required;
Swimming Pools & Spas
612.1
Spas & heated pools must have covers (except solar heated). Non-commercial poQIs
must have a pump timer. Gas spa & pool heaters must have a minimum thermal
efficiency of 78%.
Shower heads
612.1
Water flow must be restricted to no more than 2.5_gallons per minute at 80 PSIG.
Air Distribution Systems
610.1
All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically
attached, sealed, insulated, and installed in accordance with the criteria of Section 610.
Ducts in unconditioned attics: R-6 min. insulation.
HVAC Controls
607.1 ..
Separate readily accessible manual or automatic thermostat for each system.
Insulation
604.1., 602.1. ...:.......
Ceilings-Min..R-19. Common walls -Frame R-11 or CBS R-3 both sides.
-
Common ceiling & floors R-11.
EnergyGaugleTM DCA Form 60OA-97 EnergyGauge®/FIaRES'97 FLRCNA-200
,ENERGY PERFORMANCE LEVEL, (EPIC)
DISPLAY -CARD
ESTIMATED ENERGY PERFORMANCE SCORE*. 82.4-
The higher the score, the more efficient the home.
1. New construction or existing
2. Single family or multi -family
3. Number of units, if multi -family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ft2)
7. Glass area & type
a. Clear - single pane
b. Clear - idoublepane
c. Tint/other SC/SHGC - single pane
d. Tintlother SC/SHGC - double pane
8. Floor types
a. Slab -On -Grade Edge Insulation
b. N/A
c. N/A
9. Wall types
a. Concrete, Int Insul, Exterior
b. Frame, Wood, Adjacent
c. N/A
d. N/A
e. N/A
10. Ceiling types
a. Under Attic
b. Under Attic
c. N/A
11. Ducts
a. Sup: Unic. Ret: Unc. AH: Garage
b. N/A
New _
12. Cooling systems
Single family ._
a. Central Unit
1 _
-
3 _
b. N/A
Yes _
1217 ft2
c. N/A'
0.0 ft2 _
13. Heating systems
0.0 ft2 _
a. Electric Heat Pump
132.0 ft2 _
0.0 ft2
b. N/A
R=0.0, 160.0(p) ft
R=4.2, 1000.0 ft2 _
R=11.0, 1.55.0 ft2
R=19.0, 740.0 f12 _
R=19.0, 538.0 ft2
Sup. R=6.0, 67.0 ft
c. N/A
14. Hot water systems
a. Electric Resistance
b. N/A
c. Conservation credits
(HR-Heat recovery, Solar
DHP-Dedicated heat pump)
15. HVAC credits
(CF-Ceiling fan, CV -Cross ventilation,.
HF-Whole house fan,
PT -Programmable Thermostat,
RB-Attic radiant barrier,
MZ-C-Multizone cooling,
MZ-H-Multizone heating)
I certify that this home has complied with the Florida Energy Efficiency Code For Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature:
Address of New Home:
Date:
City/FL Zip:
il•
Cap: 34.0 kBtd/hr _
SEER: 10.00
Cap: 34.0 kBtu/hr _
HSPF: 6.80
Cap: 40.0 gallons _
EF: 0.94
*NOTE: The homd's estimated energy performance score is only available through the FLARES computer program.
This is not a Building Energy Rating. If your score is 80 or greater (or 86 for a US EPA/DOE EnergyStar designation),
your home may qualify for energy efficiency mortgage (EEM) incentives if you obtain a Florida Energy Gauge Rating.
Contact the Energy Gauge Hotline at 4071638-1492 or see the Energy Gauge web site at www.fsec.ucf edu for
information land a list of certified Raters. For information about Florida's Energy Efficiency Code For Building Construction,
contact the Department of Community Affairs at 8501487-1824.
EnergyGauge® (Version: FLRCNA-200)