HomeMy WebLinkAboutPROJECT INFORMATION' RIGHT-J LOAD AND EQUIPMENT SUMMARY
Entire House
TRACY D STEELE A/C Job: 6-16-00
For: HANOVER/ST.ANDREW
Notes:
Design
Information
,. Weather: Fort Pierce, FL, US
Winter Design Conditions
Summer Design -Conditions .
OUtside;db' : 42. OF
Outside db 90- ,°F'
Inside,db" `$ 70 OF
Inside db 75 °F..
Design TD 28 OF
Design TD. , ` .15- OF
Daily range M
Relative humidity " 55
Moisture difference � `-55 - grAb
S.u.mmarY
Sensible-Coolin9.. ,Equipm,ent,.Load Sizing
..
°,, , Bu'lding heat loss' ; " " '` 36127 Btuh
-
Structure ' . ` 32666, Btuh
Ventilation. air" ' .: : , ',°`.:_' " 0 . cfm:
Ventilation 0 Btuh
Venfilatio6air loss., -; _ : ; 0' Btuh
Design temperatur6swing - ..3.0 °F
Design heat load 36127 Btuh
Use mfg. data n
Infiltration' "
Rate/swing multiplier.0.95
Total Sens, equip. [gad 31;033 Btuh
Method, .i. Y Simplified
`
Latent Cooling Equipment"4oad Sizing
Construction quality . Average =
`
Fireplades ; ' _ 0, .
Internal gains 1380 Btuh
Ventilation 0 Btuh
Heating Cooling.
Infiltration - : ', , 7040 Btuh
Area (ftz) :. 1889, 1889-
Total latent equip. load 8420 Btuh
V6lumeift3)+', `' 18850 18850,
AirlchangeS/hour,", . ; :. ; ,... ,0:.$: ,: 0.6' '
Total equipment load, 39452 Btuh
Equiv. AVF,(cfm) .,:, : 252: - 189
'
a.
' Hea'tm EE ui rent S;umlma
9 q: P 171; :
'. Coolin ' E ui merit Summary
9 q p rY
Make GOODMAN MANUF ::,'
" ' `.
ke, GOODMAN MANUR ,- `
_ Ma -
Trade Janitrol, GMC, Liberty,
- Trade'- Janitrol„GMC,'Liberty,.
CPKE48-1;
CPKE48-1
A491XX
Efficiency. • 7.5 HSPF .
;Efficiency; 110.0 SEER
Heating input' . 0*. Btuh
Sensible -cooling "_-- ' ' 30800 Btuh
Heating output' _ 0 -Btuh =
`
Laten_f`coolirig., , :; .: ;_. 13200 Btuh,
Heating'temp rise = . - o . OF, " '"
Total cooling : .44000 Btuh
Actual heating fan; , . 1414. cfm...:.'
; Actual cooling,fan - 1414 cfm
Heating air flow factor 0.039 cfrh/Btuh'
Cooling air flow, -factor,': " ' 0.043 . cfm/Btuh
Space thermostat
Load sensible heat ratio- ,80 %
Printout certified by ACCA to meet all requirements of Manual J-7th Ed..
R v%%riollItSCOft Right -Suite Residential'*' 5.0.12 RSR27474
CAy Documents\Wrightsoft HVACIST. ANDREW SMALL LV.RM..rsr
2000Sep-28 09:55:00
Page 1
RIGHT-J SHORT FORM
Entire House
TRACY D STEELE A/C
Job: 646-00
Project I•
•
For: HANOVER/ST.ANDREW
Design Information
�,,Outside
Htg Clg
Infiltration
db (OF) 42 90
Method Simplified
,side db (°F) 70 75
Construction quality Average
Design TD (°F) 28 15
Fireplaces
0
;Daily range - M
Inside humidity (%) - 55
Moisture difference (gr/lb) - 55
HEATING EQUIPMENT
COOLING EQUIPMENT
Make
GOODMAN MANUF
Make GOODMAN MANUF
Trade
Janitrol, GMC, Liberty,
Trade Janitrol, GMC, Liberty,
CPKE48-1
CPKE48-1
A49-XX
Efficiency
7.5 HSPF
Efficiency 10.0 SEER
Heating input 0 Btuh
Sensible cooling 30800
Btuh
Heating output 0 Btuh
Latent cooling 13200
Btuh
Heating temperature rise 0 OF
Total cooling 44000
Btuh
Actual heating fan 1414 cfm
Actual cooling fan 1414
cfm
Heating air flow factor 0.039 cfm/Btuh
Cooling air flow factor 0.043
cfm/Btuh
Space thermostat
Load sensible heat ratio 80 %
ROOM NAME
Area
(ft2)
Htg load
(Btuh)
Clg load
(Btuh)
Htg AVF
(cfm)
Clg AVF
(cfm)
BED 11
285
7180
6011
281
260
BED 2
132
2814
3486
110
151
' GUEST
176
6292
4887
246
212
G. BATH
40
1554
866
61
37
LNDY
42
739
408
29
18
KITCH.
195
894
1847
35
80
BATH
40
678
605
27
26
WIC
20
159
93
6
4
GATH. RM.
378
5727
6214
224
269
G.M.R.
64
2446
2949
96
128
GREAT RM.
156
5381
3767
211
163
M. BATH
98
1471
826
58
36
M. WIC
63
93
130
4
6
MISC. HALLS
200
700
576
27
25
Printout certified by ACCA to meet all requirements of Manual J 7th Ed.
?^= wnghtsoft
Right -Suite Residentia[Tm 5.0.12 RSR27474
2000-Sep-28 09:55:00
AM Q* Documents\Wdghtsoft
HVAC\ST. ANDREW SMALL LV.RM..rsr
Page 1