HomeMy WebLinkAboutNOA - ROOF PANELMIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208
BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474
—`1— VF315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA)miamidade. ov/economy
'RECETV
L.V. Thompson, Inc.
5015 E. Hillsborough Avenue NOV _..1 2018
Tampa, FL. 33610 C4
Permitting Department St Y���
' p ent �
SCOPE: I St. Lucie Count FL ue�e C°�°'�
This NOA is being issued under the applicable rules and re ction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product
or materialltested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use
of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is
determined, by Miami -Dade County Product Control Section that this product or material fails to meet the requirements
of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
: 5V Crimp Roof Panel
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
. RENEWAIL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERNIIN�TION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
I
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall l)e done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews and revises NOA# 11-0808.09 and consists of pages 1 through 5.
The submitted documentation was reviewed by Alex Tigera. c -Fi1e Copy
` .� . NOA No.: 16-1012.17
Miaru•D�ecouNr�r _ Expiration Date: 1.1/30/21
Approval Date: 1.1/23/16
Page 1 of 5
A
ROOFING ASSEMBLY APPROVAL:
Category
Sub-Caterzory
Material:
i
Deck Type:
Maximum iDesien Pressure
Roofing
Non -Structural Metal Roofing
Steel
Wood
See Table A
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLwANT:
Product Dimensions Test Product
Specifications Description
"5V" Steel Roofing 1= varies TAS 125 Metal Roof Panel conforming with
Panel w = 24" ASTM A792 coated with Aluzinc.
h=%"
Min. Thickness 0.019"
Min yield strength: 48ksi
Trim Pieces' 1= varies
w = varies
Thickness 0.0276.
MANUFACTURING LOCATION:
1
1. Tampa, FL.
EVIDENCE SUBMITTED:
i
j Test ALYency
PRI Constriction Materials
Technologies LLC
Test Identifier
LVTI-008-02-01
LVTI-020-02-03
LVTI-021-02-01
LVTI-020-02-02
TAS 110 Standard flashing and trim pieces.
Manufactured for each panel width.
Test Name/Revort
TAS-100
ASTM B 117 / TAS 110
TAS 125
ASTM G 155
Date
08/07/0,6
10/25/16
10/26/1.6
11/16/16
NOA No.: 16-11012.17
Expiration Date: 11/30/21
Approval Date: 11/23/16
Page 2 of 5
APPROVED ASSEMBLIES:
System: 115V-Crimp" Metal Panels
Deck Type: Wood, Non -Insulated
Deck Description: "/32" or greater plywood or wood plank.
Slope Range: 211: 12" or greater
Maximum Uplift See Table A below
Pressure:
Deck Attachment:
In accordance with applicable Building Code, but in no case shall it be less than 8d annular
ring shank nails spaced 6" o.c. In reroofing, where the deck is less than 19/32" thick
(Minimum "/32"). The above attachment method must be in addition to existing
attachment.
Underlayment:
Minimum underlayment shall be an ASTM D 226 Type I installed with a minimum 1.9"
side -laps and 6" end -lap fastened with corrosion resistant tin -caps and 1'/a" annular ring -
shank nails, spaced 6" o.c. at all laps and two staggered rows 12" o.c. in the field of the roll;
followed by one layer of Polyglass TU Plus installed over the ASTM D 226 Type I. 'Refer
to Polyglass USA current published installation instructions.
Fire Barrier Board:
Any approved fire barrier having a current NOA. Refer to a current fire directory lisiting for
fire ratings of this roofing system assembly as well as the location of the fire barrier within
the assembly. See Limitation # 1.
Valleys:
Valley construction shall be in compliance with Roofing Application Standard RAS '133
and with L.V. Thompson Inc.'s current published installation instructions.
Metal Panels and
Install the "W" Steel Roof Panels and accessories in compliance with LV Thompson Inc.'s
Accessories:
current, published installation instructions and details. Flashing, penetrations, valley
construction and other details shall be constructed in compliance with the minimum
requirements provided in Roofing Application Standards RAS 133.
Panel fasteners shall be #9HH self tapping screws with sealing washer of sufficient length
to penetrate through the sheathing a minimum of 3/t6 inch.
Fasteners shall be installed at high points of panel ribs (see Detail A) at a maximum :spacing
as listed in Table A below parallel to the slope. (see Detail B)
Fasteners shall be installed at a maximum of 12" o.c. at panel edge.
TABLE A
MAXIMUM DESIGN PRESSURES
Roof Areas
Field
Perimeter and Cornerl
Maximum Design Pressure
-71.25 psf
-127.5 psf
Maximum Fastener Spacing
16" o.c.
8" o.c.
1. Extrapolation shall not be allowed
NOA No.: 16-1012.17
QMLAMI-DADE COUNTY Expiration Date: 11/30/21
Approval Date: 11/23/16
Page 3 of 5
SYSTEM LiwrATIONS
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire
ratings of this product.
2. The aximum designed pressure listed herein shall be applicable to all roof pressure zones (i.e. field, perimeters,
and cmorners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced
pressure zones (i.e. perimeters, extended corners and corners).
3. Panels may be rolls formed in continuous lengths from eave to ridge. Maximum lengths shall be as described in
Roofing Application Standard RAS 133
4. All panels shall be permanently labeled with the manufacturer's name and/or logo, and the following statement:
"Miami -Dade County Product Control Approved" or with the Miami -Dade County Product Control Seal as seen
below. All clips shall be permanently labeled with the manufacturer's name and/or logo, and/or model.
5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule i61 G20-3 of the Florida Administrative Code.
NOA No.: 16-11012.17
MIAMI•DAD, COUNTY Expiration Date: 11/30/21
Approval Date: 11 /23/16
Page: 4 of 5
PROFILE DRAWINGS:
DETAIL A
i
24" Coverage
Minimum #9HHself tapping
screws w/ self sealing.
3 "Minimum penetration
through the deck
See Table A
Overlap
2.5"` /
Overlap
END OF THIS ACCEPTANCE
MIAMI•DADE COUNTY
I
I
1/2"
NOA No.: 16-1012.17
Expiration Date: 1 D 30/21
Approval Date: 11/23/16
Page 5 of 5