REVIEW COMMENTS
1
Ownei(s):
Gwendolyn Landers
SG' A�
Jurisdiction: SAINT LUCIE COUNTY St .�Y`V�®
Lot#: Block: �4C/G CO
4h`Y
Stories:.
Review jM Status Reviewed By
FRONT COUNTER REVIEW COMPLETE Deanna Givens
Automatic Sprinkler System? No
Fax Number: 772-770-5961
Email: Carenm@Crystalpoolsirc.Co
m
Date Started Date Completed Date Released
10/30/2018 10130/2018 1013012018
Comment:
PLANS EXAMINER REVIEW
INCOMPLETE Jpi, Inc 111812018
Comment:
1) PILE REQUIREMENT PER CURTIS SINCLAIR INC DATED 5115118, REQUIRES 17.5 TON DESIGN & 35 TON
ULTIMATE CAPACITY. NUTTING ENGINEER'S AUGERCAST PILE INSTALLATION MONITORING REPORT,
11/8/2018
DATED 8/31/18 STATES POOL ATTAINED THE REQUIRED COMPRESSIVE CAPACITY OF 15 TONS. THE
POOL PILE DRAWINGS REFERENCED IN THE NUTTING ENGINEERS' REPORT SHOWS DIFFERENT DESIGN
CAPACITY REQUIREMENTS THAN THE POOL DRAWINGS SUBMITTED FOR PERMIT. REVISE AS NEEDED.
([A] 107.2.1)
11/8/2018 Comment:
2) EXISTING POOL BARRIER DOES NOT MEET THE REQUIREMENTS OF (FBC 454.2.17), GATES THAT
PROVIDE ACCESS TO THE SWIMMING POOL MUST OPEN OUTWARD AWAY FROM THE POOL.
Comment:
3) MECHANICAL EQUIPMENT SERVICING THE POOL SHOULD BE ELEVATED ABOVE THE BFE. TANKS MAY
11/8/2018
NEED TO BE ANCHORED TO PREVENT A BUOYANCY FAILURE. EQUIPMENT SHALL BE LOCATED AT OR
ABOVE THE ELEVATION. (R322.1.6)
11/8/2018 Comment:
4) PLEASE PROVIDE PRODUCT DATA FOR ALL EQUIPMENT, DRAINS, BARRIERS, COVERS PROVIDED.
HEATER, PUMP, COVER, ALARM, WATER SUPPLY. ([A] 107.2.1)
11/8/2018 Comment:
5) WATER SUPPLY/AUTO FILLER- SHOW BACKFLOW PREVENTION. (454.2.9)
11/8/2018 Comment:
6) EXISTING POOL BARRIER SHOWN DOES NOT MEET THE REQUIREMENTS OF (FBC 454.2.17), GATES
THAT PROVIDE ACCESS TO THE SWIMMING POOL MUST OPEN OUTWARD AWAY FROM THE POOL.
ZONING REVIEW
COMPLETE Angela Huff 11/6/2018 11/6/2018 111612018
Comment: