HomeMy WebLinkAboutGENERATOR - 10-30-18,
�/20. �.12 W
91k
• True Power- Electrical Technology
• Two Line LCD Multilingual Digital
Evolution- Controller (English/Spanish/
Fri nch/Portuguese)
• Two Transfer Switch Options Available:
100 Amp, 16 Circuit Switch or
200 Amp Service Rated Smart Switch.
See Page 5 for Details.
RE ICEICE VE®
OCT 3 0 2018
ST. Lucie County, Permitting
• Electronic Governor
• Standard Wi-Fi'" Remote Monitoring
• System Status & Maintenance interval LED Indicators
• Sound Attenuated Enclosure
• Flexible Fuel Line Connector
• Di�ect-To-Dirt Composite Mounting Pad
• Natural Gas or LP Gas Operation
• 5 Year Limited Warranty
GENERAC°
GUARDIAN° SERIES
Residential Standby Generators
Air -Cooled Gas Engine
Standby Power Rating
Models 0007036-1, G007037-1 (Aluminum - Bisque) -16 kW 60 Hz
Model G007035-1 (Aluminum - Bisque) -16 kW 60 Hz
Models G007039-1, G007038-1 (Aluminum - Bis ue - 20 kW 60 Hz
STLIL•UCIE CO odels 0007043-2, G007042-2 (Aluminum - Bisque) - 22 kW 60 Hz
(PLAN REVIE
a 9)G;
DATE:
DA
PLUMB,
DATE:
MECH
DATE:
• Listed and Labeled by the Southwest Research Institute allowing
installation as close as 18" (457 mm) to a structure.*
*Must be located away from doors, windows, and fresh air
intakes and in accordance with local codes.
hP,s;:l/assets.s,wi.orgllibrar7lDiredtory02FstedProducisl
Construc6cnlndustryl973 DoC 204_13204-01-01_Rev9.pdf
FEA
RES
O INNOVATIVE ENGINE DESIGN & RIGOROUS TESTING are at the heart of Generac's O
success in providing the most reliable generators possible. Generac's G-Force engine
lineup offers added peace of mind and reliability for when you need it the most. The
G-Force series engines are purpose built and designed to handle the rigors of
extended run times in high temperatures and extreme operating conditions.
O TRUE POWER'" ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave
form produce less than 5% Total Harmonic Distortion for utility quality power. This allows
conrdent operation of sensitive electronic equipment and micro -chip based appliances,
such as variable speed HVAC systems.
O TEST CRITERIA:
J PROTOTYPE TESTED J NEMA MG1-22 EVALUATION
J SYSTEM TORSIONAL TESTED J MOTOR STARTING ABILITY
O MOBILE LINK- REMOTE MONITORING: FREE with every Guardian Series Home
standby generator. Allows you to monitor the status of your generator from anywhere In the
world using a smartphone, tablet, or PC. Easily access information such as the current
operating status and maintenance alerts. Connect your account to your authorized service
dealer for fast, friendly and proactive service, With Mobile Link, you are taken care of before
the next power outage.
C�J'LUS nl I
LISTED u[�J
Note: CUL certiliation only applies to unbundled units and units pacl¢ged with,
the UScircuit nswitches. Units plc witlbthe ma Srti chaff tU celpled i
SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION:
This state-of-the-art power maximizing regulation system is standard on
all Generac models. It provides optimized FAST RESPONSE to changing
load conditions and MAXIMUM MOTOR STARTING CAPABILITY by
electronically torque -matching the surge loads to the engine. Digital
voltage regulation at ±1°%.
O SINGLE SOURCE SERVICE RESPONSE,from Generac's extensive dealer
network provides parts and service know-how for the entire unit, from the
engine to the smallest electronic component.
O GENERAC TRANSFER SWITCHES: Long life and reliability are
synonymous with GENERAC POWER SYSTEMS. One reason for this
confidence is that the GENERAC product line includes its own transfer
systems and controls for total system compatibility.
W GENERALQ.�T•�, ;{�'�
�I
PROMISE :•0•
OO
16/20/22 kW
Engine
• Genera Ic G-Force design
• "Spinyllok" cast iron cylinder walls
• Electronic ignition/spark advance
• Full
GENERACA
and benefits
Maximizes engine "breathing" for increased fuel efficiency. Plateau honed cylinder walls and plasma moly
rings helps the engine run cooler, reducing oil consumption resulting in longer engine life.
Rigid construction and added durability provide long engine life.
These features combine to assure smooth, quick starting every time.
pressure lubrication system Pressurized lubrication to all vital bearings means better performance, less r aintenance and longer engine
life. Now featuring up to a 2 year/200 hour oil change interval.
• Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil.
• High temperature shutdown Prevents damage due to overheating.
Generator
• Revolving field
Allows for a smaller, light weight unit that operates 25% more efficiently than a revolving armature
generator.
• Skewed stator Produces a smooth output waveform for compatibility with electronic equipment.
• Displaced phase excitation Maximizes motor starting capability.
• Automatic voltage regulation Regulates the output voltage to ±1 % prevents damaging voltage spikes.
• UL 2200111sted For your safety.
Transfer Switch (if applicable)
• Fully automatic Transfers your vital electrical loads to the energized source of power.
• NEMA 3R Can be installed inside or outside for maximum flexibility.
• Remote mounting Mounts near your existing distribution panel for simple, low-cost installatioh.
i
Evolution- Controls —
• Auto/Man6al/Off illuminated buttons
• Two-line LCD multilingual display
• Sealed, raised buttons
• Utility voltage sensing
• Generator voltage sensing
• Utility interrupt delay
• Engine warm-up
• Engine cool -down
• Programmable exercise
• Smart battery charger
• Main he ct it b
Selects the operating mode and provides easy, at -a -glance status indication in any condition.
Provides homeowners easily visible logs of history, maintenance and events up to 50 occurrences.
Smooth, weather -resistant user interface for programming and operations.
Constantly monitors utility voltage, setpoints 65% dropout, Bo% pick-up, oistandard voltage.
Constantly monitors generator voltage to ensure the cleanest power delivered to the home.
Prevents nuisance start-ups of the engine, adjustable 2-1500 seconds from the factory default setting of
five (5) seconds by a qualified dealer.
Ensures engine is ready to assume the load, setpoint approximately 5 seconds.
Allows engine to cool prior to shutdown, setpoint approximately 1 minute.
Operates engine to prevent oil seal drying and damage between power outages by running the generator
for 5 minutes every other week. Also offers a selectable setting for weekly ormonthly operation providing
flexibility and potentially lower fuel costs to the owner.
Delivers charge to the battery only when needed at varying rates depending on;outdoor air temperature.
Compatible with lead acid and AGM -style batteries.
rcui reaker Protects generator from overload.
• Electronic 9i ovemar Maintains constant 60 Hz frequency.
Unit
• SAE weather, protective enclosure Sound attenuated enclosures ensure quiet operation and protection against'mother nature, withstanding
winds up to 150 mph. Hinged key locking roof panel for security. Lift -out front far easy access all routine
maintenance items. Electrostatically applied textured epoxy paint for added durability.
• Enclosed critical grade muffler Quiet, critical grade muffler is mounted inside the unit to prevent injuries. 11
• Small, comp ct, attractive Makes for an easy, eye appealing installation, as close as 181,(457 mm) away from a building.
GENERAC°
16
/20/22 kW
specifications
Generator
Model
- G0070V-1.G007036-1.
Common
--Samdlitypo outage. waan from
froMofthe generator, Sound levels UMfrom other Sides ofMegenerator maybehigher dependingoninSWIgonparameters Ratmgde8nfions-Stand
of the utility i, le outage. No ovedoad capabirity is aWable far this rating• (AII ratings in accordance with SS5514, IS03046 and DW6271). • lNmdmum m RaliWavolt amps and current are subject to a
cerdem ambietdtemperaNre altitude, engine pawerand candd on, etc. Max mum pawerdecreasesahout 3S percent for each 1.000 feet (304.8 meters) above sea level; and also w01 deQeaseeabbout 1
z
16/20/22 kW
G007005-0 ' Wi-F LP Fuel Level Monitor
G005819-0
' 26R Wet Cell Battery
G007101-0
Battery Pad Warmer
13007102;0
:Oil Warmer
13007103;1
;Breather Warmer
G005621-0
• Auxiliary Transfer Switch
Contact Kit
G007027-0 - Bisque
:Fascia Base Wrap Kit
(Standard on 22 kW)
G005703-0 - Bisque
Paint Kit
G006485-0 Scheduled Maintenance Kit
G006873-0 .,smart Management Module
i (50 Amps)
— — ---r -
GENERAC
available accessories
'The Wi-F enabled LP fuel level monitor provides constant monitoring of the! connected LP fuel tank Mon
itoring the LP tank's fuel level is an important step in making sure your generator is ready to run during an
unexpected power failure. Status alerts are available through a free application to notify when your LP tank
is in need of a refill.
Every standby generator requires a battery to start the system. General; offers the recommended 26R wet
cell battery for use with all air-cooled standby product (excluding PowerPact®).
: The pad warmer rests underthe battery. Recommended for use If the temperature regularly falisbelow —
0 OF (-18 °C)` (Not necessary for use with AGM -style batteries).
Oil wanner slips directly over the of filter. Recommended for use it the temperature regularly falls below
(-18'C).
The breather warmer is for use in extreme cold weather applications. For use with Evolution controllers
only in climates where heavy icing occurs.
'The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load'
you may not need. Not compatible with 50 amp pre -wired switches.
The fascia base wrap snaps together around the bottom of the new air cooled generators. This offers a
:sleek, contoured appearance as well as offering protection from rodents and insects by covering the lifting'
holes located in the base.
If the generator enclosure is scratched or damaged, it is Important to touchup the paint to protect from
:future corrosion. The paint kit includes the necessary paint to properly maintain or touch up a generator
enclosure.
Generac's scheduled maintenance kits provide all the hardware necessary to perform complete routine 1
maintenance on a Generac automatic standby generator.
Smart Management Modules are used in conjunction with the Automatic Transfer Switch to increase its
power management capabilities. it provides additional power managementfiexibility not found in any other;
power management system.
dimensions & UPCs
Dimensions sham are approximate. Refer to installation manual for exact dmensions. DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES.
4�•+�M
FRONT VIEW
GENERAC• General: Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 4! generac.com
02018 Generac Power systems, Inc. All rights reserved. Ali spedficafts are subject to change without notice. Part No. 100000001g4R (8/01/18)