HomeMy WebLinkAboutLETTER ABOUT FINAL INSPECTION - REROOFINGi
LUJIS F ORTEGA, PE
CivillStructural Engineer
November 16, 2018
St. Lucie County
Building and Zoning Department
Fort Pierce, Florida
Re: STATEMENT FOR FINAL INSPECTION REROOFING
Single Family Home
102 N Las Olas Dr.
Jensen Bch., FL
Permit No. 1810-0676
Contractor. The RoofSmith
I
Dear Building Official:
RECEIVED
NOV 2 01018
Permitting Department
St, Lucie County
st�U eyNFo
cue C
®4nt.Y
accept this letter as a Statement for Inspection for the below mentioned inspection as follows:
INSPECTION DATE:
INSPECTION TYPE:
TTEMS INSPECTED:
REM"KS:
INSPECTIONf STATUS:
November 15, 2018
STEEP SLOPED ROOF RESURFACING ON WD DECK (4:12)
Renailigg: 8d R.S. nails 6" o/c at panel edges & at intermediate supports.
Underlayment: (2)-plies of 30# felt fastened to deck with 1'/4" RS. nails tin caps
6" o/c at laps 8c in (2) rows 12" o/c staggered in the middle of the sheet.
Shin e: Owens Coming Duration Asphalt Roof Shingle fastened to wood deck
with (6)1%" RS. nails.
Dri e: galy. sheet 3x3, 26 Ga., fastened to deck with 1'/4" R.S. nails @ 4" o%
Tie -In: Vertical metal 1" rise from ridge to cave.
Inspected above items as per permit documents and shingle manufacturer's NOA
No.16-0425.01
MWutke"I M17
If you I have any questions or concerns in regards to the above matter, please do not hesitate to contact our office at
(954) 937-2484.
1 OF 1