HomeMy WebLinkAboutLETTER ABOUT FINAL INSPECTION - REROOFINGi LUJIS F ORTEGA, PE CivillStructural Engineer November 16, 2018 St. Lucie County Building and Zoning Department Fort Pierce, Florida Re: STATEMENT FOR FINAL INSPECTION REROOFING Single Family Home 102 N Las Olas Dr. Jensen Bch., FL Permit No. 1810-0676 Contractor. The RoofSmith I Dear Building Official: RECEIVED NOV 2 01018 Permitting Department St, Lucie County st�U eyNFo cue C ®4nt.Y accept this letter as a Statement for Inspection for the below mentioned inspection as follows: INSPECTION DATE: INSPECTION TYPE: TTEMS INSPECTED: REM"KS: INSPECTIONf STATUS: November 15, 2018 STEEP SLOPED ROOF RESURFACING ON WD DECK (4:12) Renailigg: 8d R.S. nails 6" o/c at panel edges & at intermediate supports. Underlayment: (2)-plies of 30# felt fastened to deck with 1'/4" RS. nails tin caps 6" o/c at laps 8c in (2) rows 12" o/c staggered in the middle of the sheet. Shin e: Owens Coming Duration Asphalt Roof Shingle fastened to wood deck with (6)1%" RS. nails. Dri e: galy. sheet 3x3, 26 Ga., fastened to deck with 1'/4" R.S. nails @ 4" o% Tie -In: Vertical metal 1" rise from ridge to cave. Inspected above items as per permit documents and shingle manufacturer's NOA No.16-0425.01 MWutke"I M17 If you I have any questions or concerns in regards to the above matter, please do not hesitate to contact our office at (954) 937-2484. 1 OF 1 116 HIDDEN CT ROAD, HOLLYWOOD, FLORIDA 33023 TEL: 954.937.2484 FAX: 954.962.1801