HomeMy WebLinkAboutNOA - UNDERLAYMENTSI \�
RF�E1VFo
Orr
' 0
Permit*? ?016 MIAMI-DADE COUNTY
M�1i�MI. St 4uc e C118 oI � ��t PRODUCT 805 SW 26 CONTROL
Room SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 31525-99
NOTICE OF ACCEPTANCE (NOA) www.miamidade.Qov/economy
Interwrap, Inc. SCANNED
Mission Way FILE COPY BY
Missi
Mission, BC, Canada V2V-6E4 E r� St Lucie County
SCOPE: `1 E
1 A-\ �This NOA is being issued under the appable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control
Section 6n Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to
have this) product or material tested for quality assurance purposes. If this product or material fails to perform in
the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately
revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to
revoke tliis acceptance, if it is determined by Miami -Dade County Product Control Section that this product or
material fails to meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Titanium® UDL-30, Titanium® UDL-50, RhinoRoof U10, RhinoRoof U20, Titanium UDL25
Synthetic Underlayments
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWIAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTiISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA No. 14-0603.18 and consists of pages 1 through 4.
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 18-0814.09
MIAMI•DADE COUNTY Expiration Date: 08/08/23
1 Approval Date: 08/30/18
Page 1 of 4
ROOFING COMPONENT APPROVAL
Category: Roofing
Sub -Category: Underlayment
Material: Polypropylene
SCOPE:
This acceptance is for, Titanium° UDL-30, Titanium® UDL-50, , , , , , RhinoRoof U20, Titanium UDL25, and
Synthetic Underlayments as described in this Notice of Acceptance, for use with approved prepared roof assemblies
where ASTM D226 Type underlayment is specified and installed with prescribed approved fasteners and fastener
densities! Designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the
Florida Building Code
PRODUCT DESCRIPTION:
Test
Product
Product
Dimensions
Specification
Description
Titanium ,P UDL-30
48" x 250' rolls
ASTM D226
Woven synthetic polymer underlayment with two
Manufacturing
Type I & 1I
sides coated.with UV protected and slip resistant
Location #1
polymer stabilized polypropylene on both sides.
Titanium UDL-50
48" x 250' rolls
ASTM D226
Woven synthetic polymer underlayment with two
Manufacturing
Type I & H
sides coated with UV protected and slip resistant
polymer stabilized polypropylene on both sides.
Location #1
I
RhinoRoof U20
42" x 286' rolls
ASTM D226
Woven synthetic polymer underlayment with two
I
Manufacturing
Type I and II
sides coated with UV protected and slip resistant
Location #1
polymer stabilized polypropylene on both sides.
TitaniumUDL25
48" x 250' rolls
ASTM D226
Woven synthetic polymer underlayment with two
Manufacturing
Type I and II
sides coated with UV protected and slip resistant
Location 41
polymer stabilized polypropylene on both sides.
RhinoRo If U10
42" x 286' rolls
ASTM D226
Woven synthetic polymer underlayment with two
Manufacturing
Type I & II
sides coated with UV protected and slip resistant
Location #1
polymer stabilized polypropylene on both sides.
LOCATIONS:
1
NOA No.: 18-0814.09
Expiration Date: 08/08/23
Approval Date: 08/30/18
Page 2 of 4
EVIDENCE SUBMITTED:
(rest Agency
i
Intertek jesting Services
Trinity I ERD
Test Identifier
Test Name/Report
Date
#3031783
TAS 104
02/19/03
3119607COQ-003B
ICC-ES AC48
02/20/08
3124826-01
ASTM E108
02/19/08
3124826MID-007
ASTM E108
02/25/08
311801000Q-003
ASTM D226
02/20/08
3130639COQ-002A
ASTM D226
02/20/08
3146738COQ-003A
ASTM D226
06/20/11
3146738COQ-003B
ASTM D 1876/ TAS 117
03/28/08
101465036COQ-001
ASTM D1970
06/27/14
100539395COQ-006
ASTM D226
06/02/14
101863861COQ-OOIA
ASTM D226
10/28/14
101823107COQ-011
ASTM D226
12/09/14
I15010.05.10
ASTM D4798 / D226
05/14/10
I38010.08.11
ASTM D226
08/11/11
I35520.08.11
ASTM D2523 / D1781
08/17/11
INSTALLATION SPECIFICATIONS:
Titanium® UDL-30, Titanium® UDL-50, RhinoRoof U10, RhinoRoof U20, and Titanium UDL25 Synthetic
Underlayments
1. Titanium® UDL-30, Titanium® UDL-50, RhinoRoof U10, RhinoRoof U20, and Titanium UDL25 Synthetic
Underlayments shall be installed in strict compliance with applicable Building Code.
2. Titanium® UDL-30, Titanium® UDL-50, RhinoRoof U10, RhinoRoof U20, and Titanium UDL25 Synthetic
Underlayments shall be installed with a minimum 4-inch head lap in a shingle layer fashion.
J. Titanium® UDL-30, Titanium® UDL-50, RhinoRoof U10, RhinoRoof U20, and Titanium UDL25 Synthetic
Underlayments shall be fastened with Miami -Dade approved corrosion resistant tin -caps and 12 gauge 1 ''/4"
annular ring -shank nails, spaced 6" o.c. at all laps and three staggered rows fastened 12" o.c. in the field of the
roll.
1
4. Titanium® UDL-30, Titanium® UDL-50, RhinoRoof U10, RhinoRoof U20, and Titanium UDL25 Synthetic
Underlayments may be used with Asphaltic shingles, Wood shakes and shingles, Non-structural metal roofing,
and quarry slate. Titanium® UDL-30, Titanium® UDL-50, RhinoRoof U10, RhinoRoof U20, and Titanium
�DL25 Synthetic Underlayments shall not be used as roof tile underlayments.
5. For Roof Tile applications; may be used as an anchor sheet in roof tile applications when used in combination
with a top membrane layer, consisting of a Miami -Dade approved TAS 103 self -adhering underlayment. (See
current NOA listing of approved TAS 103 self -adhering underlayment for installation guidelines and
limitations of use).
6. For fire classification of specific roof assemblies using Titanium® UDL-30, Titanium® UDL-50, RhinoRoof
U10, RhinoRoof U20, and Titanium UDL25 Synthetic Underlayments refer to a current Approved Roofing
1Vlaterials Directory for fire ratings of this product.
NOA No.: 18-0814.09
Expiration Date: 08/08/23
Approval Date: 08/30/18
Page 3 of 4
BUILDING PERMIT REQUIREMENTS:
Application for building permit shall be accompanied by copies of the following:
1. This Notice of Acceptance.
2. Any other documents required by the Building Official or applicable building code in order to properly
evaluate the installation of this material.
I
LIMITATIONS:
I
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for
fire ratings of this product.
2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with
applicable building code.
3. Titanium® UDL-30, Titanium® UDL-50, RhinoRoof U10, RhinoRoof U20, and Titanium UDL25 Synthetic
Underlayments shall be applied to a smooth, clean and dry surface with deck free of irregularities. All nails in
the deck shall be carefully checked for protruding heads. Re -fasten any loose decking panels. Sweep the deck
thoroughly to remove any dust and debris prior to application.
4. Titanium® UDL-30, Titanium® UDL-50, RhinoRoof U10, RhinoRoof U20, and Titanium UDL25 Synthetic
Underlayments shall not be hot mopped, refer to manufacturer's published literature for product compatibility.
5. Titanium® UDL-30, Titanium® UDL-50, RhinoRoof U10, RhinoRoof U20, and Titanium UDL25 Synthetic
Underlayments shall not be applied over an existing roof membrane as a recover system.
6. Titanium® UDL-30, Titanium® UDL-50, RhinoRoof U10, RhinoRoof U20, and Titanium UDL25 Synthetic
Underlayments shall not be left exposed as a temporary roof for longer than 30 days of application.
7. Titanium® UDL-30, Titanium® UDL-50, RhinoRoof U10, RhinoRoof U20, and Titanium UDL25 Synthetic
Underlayments are components used in roof system assemblies. Roof system assemblies are approved under a
specific Notice of Acceptance. Refer to Prepared Roofing system Product Control Notice of Acceptance for
listed approval of this product with specific prepared roofing products.
8. Titanium® UDL-30, Titanium® UDL-50, RhinoRoof U10, RhinoRoof U20, and Titanium UDL25 Synthetic
Underlayments may be used with any approved roof covering Notice of Acceptance listing Titanium® UDL-
3�0, Titanium® UDL-50, RhinoRoof U10, RhinoRoof U20, and Titanium UDL25 Synthetic Underlayments as
a, component part of an assembly in the Notice of Acceptance. If Titanium® UDL-30, Titanium(T UDL-50,
RhinoRoof U10, RhinoRoof U20, and Titanium UDL25 Synthetic Underlayments are not listed, a request may
be made to the Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Department
for approval provided that appropriate documentation is provided to detail compatibility of the products, wind
uplift resistance, and fire testing results.
9. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo
and the following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County
Product Control Seal as shown below.
10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code
and Rule 61 G20-3 of the Florida Administrative Code.
END OF THIS ACCEPTANCE
I
MIAMI•DADE COUNTY
I
NOA No.: 18-0814.09
Expiration Date: 08/08/23
Approval Date: 08/30/18
Page 4 of 4