Loading...
HomeMy WebLinkAboutEVALUATIO0N REPORT - ASPHALT SHINGLESCertificate of Authorization No. 29824 CREEK 17520 Edinburgh Dr Tampa, FL 33647 TECHNICAL SERVICES, LLC (813) 480-3421 EVALUATION REPORT FLORIDA BUILDING CODE, 6T" EDITION (2017) Map ufacturer: TAMKO BUILDING PRODUCTS Issued September25, 2017 220 West 4`' Street Joplin, MO 64801 (417) 624-6644 Manufacturing Plants: Joplin, MO Phillipsburg, KS SCANNED Frederick, MD BY Dallas, TX St Lucie Count Tuscaloosa, AL y i Quality Assurance: UL LLC (QUA9625) SCOPE SCANNED fBY Category: Roofing St Lucie`County Subcategory: Asphalt Shingles Code Sections: 1504.1.1, 1507.2.5, 1507.2.7.1, 1523.6.5.1 Properties: Physical properties, Wind Resistance, Wind Driven Rain REFERENCES Entity Report No. Standard Year PRI Construction Materials Technologies (TST5878) TAP-043-02-01 TAS 100 1995 PRI •Construction Materials Technologies (TST5878) TAP-051-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) TAP-054-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) TAP-114-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) TAP-117-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) TAP-130-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) TAP-131-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) TAP-165-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) TAP-280-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) TAP-303-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) TAP-307-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) TAP-314-02-01 Rev 2 TAS 100 1995 PRI Construction Materials Technologies (TST5878) TAP-315-02-01 ASTM D 6381 2008(2013)e1 PRI Construction Materials Technologies (TST5878) TAP-317-02-01 TAS 100 1995 UL LLC (TST9628) 02NK9507 ASTM D 3161 2016 UL LLC (TST9628) 04NK24366 ASTM D 3462 2010A UL LLC (TST9628) 05NK28006 ASTM D 6381 2008(2013)e1 UL 2390 UL L IC (TST9628) 06NK03898 ASTM D 7158 ASTM D 3161 2011 2016 1 ASTM D 3462 2010A UL LLC (TST9628) 08CA59132 ASTM D 3161 2016 UL LLC (TST9628) 09NK07896 ASTM D 3161 2016 ASTM D 3462 2010A UL LLC (TST9628) IOCA50498 ASTM D 3462 2010A UL LLC (TST9628) 10CA64882 ASTM D 3161 2016 UL LLIC (TST9628) 11 NK14014 ASTM D 3161 2016 ASTM D 3462 2010A UL LLC (TST9628) 12CA24551 ASTM D 3161 2016 UL LCC (TST9628) 4786110543 ASTM D 6381 2008(2013)e1 UL LLC (TST9628) 4787043752 ASTM D 3161 2016 UL LLC (TST9628) 4787148748 ASTM D 7158 2011 ASTM D 3161 2016 ASTM D 3462 2010A CREEK Technical Services LLC (ANE11669) TBP15001.3 Calculations 2017 TBP15001.4 FL18355-R4 1 of 11 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC DESCRIPTION Glass -Seal® lerick, Joplin & Glass -Seal (Frederick & Tuscaloosa) Glass -Seal (Joplin) i i Heritage® (Dallas, Frederick, Joplin, Phillipsburg & Tuscaloosa) Heritage® Premium (Dallas, Frederick, Phillipsburg & Tuscaloosa) :AMKO BUILDING PRODUCTS Asphalt Shingles 12-1/4" x 36", ASTM D 3161, Class F and ASTM D 7158, Class H self-sealing, 3-tab asphalt shingle with fiberglass mat coated on both sides with asphalt and surfaced with ceramic granules complying with ASTM D 3462. 12-1/4" x 36", ASTM D 3161, Class F and ASTM D 7158, Class H self-sealing, 3-tab asphalt shingle with fiberglass mat coated on both sides with asphalt and surfaced with ceramic granules complying with ASTM D 3462. 12-1/4" x 36", ASTM D 7158, Class H self-sealing, 3-tab asphalt shingle with fiberglass mat coated on both sides with asphalt and surfaced with ceramic granules complying with'ASTM D 3462. Shingles shall be used in the non-HVHZ only. 13-1/4" x 39-3/8", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass reinforced, laminated architectural asphalt shingle surfaced with mineral granules complying with ASTM D 3462. 13-1/4" x 39-3/8", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass reinforced, laminated architectural asphalt shingle surfaced with mineral granules complying with ASTM D 3462. Heritage® Premium 12" x 36", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass reinforced, (Frederick) laminated architectural asphalt shingle surfaced with mineral granules complying with ASTM D 3462. I Heritage® Vintage® (Phillipsburg) Heritage® Woodgate (Dallas & Frederick) Heritage® Woodgate (Frederick) Hip !nd Ridge Shingles (Frederick & Joplin) Vintage® Hip and Ridge (Phil[I psburg) TBP15.001.4 17-1/2" x 40", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass reinforced, laminated architectural asphalt shingle surfaced with mineral granules complying with ASTM D 3462. 13-1/4" x 39-3/8", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass reinforced, laminated architectural asphalt shingle surfaced with mineral granules complying with ASTM D 3462. 12" x 36-3/8", ASTM D 3161, Class F fiberglass reinforced, laminated architectural asphalt shingle surfaced with mineral granules complying with ASTM D 3462. Shingles shall be used in the non-HVHZ only. 12-1/4" x 12", ASTM D 3161, Class F fiberglass reinforced, hip and ridge asphalt shingle surfaced with mineral granules complying with ASTM D 3462. 12" x 12", ASTM D 3161, Class F fiberglass reinforced, hip and ridge asphalt shingle surfaced with mineral granules complying with ASTM D 3462. FL18355-R4 Page 2 of 11 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC k INSTALLATION .AMKO BUILDING PRODUCTS Asphalt Shingles Elite Glass -Seal® Basic Wind Speed (V„ it): Max. 194 mph (Frederick, Joplin & Basic Wind Speed (Vasd): Max. 150 mph Tuscaloosa) Deck (HVHZ): In accordance with FBC requirements; & I Solidly sheathed min. 19/32 in. plywood or wood plank for Glass -Seal new construction; Min. 15/32 in. plywood existing (Frederick, Joplin (Non- construction. HVHZ) & Tuscaloosa) Deck (Non-HVHZ): In accordance with FBC requirements; Solidly sheathed min. 15/32 in. plywood or wood plank for new construction; Min. 7/16 in. OSB existing construction. Underlayment: In accordance with FBC requirements. Min. slope: 2:12 and in accordance with FBC requirements. Refer to the manufacturer's application instructions when installing shingles at slopes greater than 21:12. ! Installation (HVHZ): Installed with 5-1/8 inch exposure in accordance with RAS 115 and manufacturer's published installation instructions. Shingles shall be attached using "6 Nail Pattern" detailed below. Installation (Non-HVHZ): Installed with 5-1/8-inch exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either "4 Nail Pattern" or "6 Nail Pattern" detailed below. NO ;}its Figure 1. Elite Glass -Seal & Glass -Seal 4 Nail Pattern (Non-HVHZ only) MAtEd� Figure 2. Elite Glass -Seal & Glass -Seal 6 Nail Pattern n TBP15001.4 FL18355-R4 Page 3 of 11 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. TBP1 This i This � J CREEK TECHNICAL SERVICES, LLC Frederick, Joplin, urg & Tuscaloosa) :@ Premium Frederick urg & Tuscaloosa) e@ Woodgate & Frederick) Basic Wind Speed (Vuit): Max. 194 mph Basic Wind Speed (Vwd): Max. 150'mph sAMKO BUILDING PRODUCTS Asphalt Shingles Deck (HVHZ): In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. Deck (Non-HVHZ): In accordance with FBC requirements; Solidly sheathed min. 15/32 in. plywood or wood plank for new construction; Min. 7/16 in. OSB existing construction. Underlayment: In accordance with FBC requirements. Min. slope: 2:12 and in accordance with FBC requirements. Refer to the manufacturer's application instructions when installing shingles at slopes greater than 21:12. Installation (HVHZ): Installed with 5-5/8 in. exposure in accordance with RAS 115 and manufacturer's published installation instructions. Shingles shall be attached using "6 Nail Pattern" detailed 'below. Installation (Non-HVHZ): Installed with 5-5/8 in. exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either "4 Nail Pattern" or "6 Nail Pattern" detailed below. `IIVAIL��ONrE, r Figure 3. Heritage@, Heritage@ Premium, and Heritage@ Woodgate (Dallas) 4 Nail Pattern (non-HVHZ only) Figure 4. Heritage@ & Heritage@ Premium 6 Nail Pattern 301.4 FL18355-R4 Page 4 of 11 ation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. ation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not addressed herein. i `> t CREEK TECHNICAL SERVICES, LLC Figure 5. Heritage® Woodgate 6 Nail Pattern :AMKO BUILDING PRODUCTS Asphalt Shingles Common Bond FASTENERS` ! ; '77t7t ;. Ch T 1 39�78" Figure 6. Heritage% Heritage® Premium, & Heritage® Woodgate Alternate 6 Nail Pattern Figure 7. Heritage® (Tuscaloosa) Expanded Nail Zone Nail patterns from Figures 3, 4, and 6 may be placed in the nail zone as described above TBP15001.4 FL18355-R4 Page 5 of 11 This eJaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This elaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. Cp K ,AMKO BUILDING PRODUCTS j� Asphalt Shingles TECHNICAL SERVICES, LLC Heritage® Premium Basic Wind Speed (V,,it): Max. 194 mph (Frederick) Basic Wind Speed (Vasd): Max. 150 mph Deck (HVHZ): In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. Deck (Non-HVHZ): In accordance with FBC requirements; Solidly sheathed min. 15/32 in. plywood or wood plank for new construction; Min. 7/16 in. OSB existing construction. Underlayment: In accordance with FBC requirements. Min. slope: 2:12 and in accordance with FBC requirements. Refer to the manufacturer's application instructions when installing shingles at slopes greater than 21:12. . Installation (HVHZ): Installed with 5 in. exposure in accordance with RAS 115 and manufacturer's published installation instructions. Shingles shall be attached using "6 Nail. Pattern" detailed below. Installation (Non-HVHZ): Installed with 5 in. exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either "4 Nail Pattern" or "6 Nail Pattern" detailed below. TBP15001.4 to Figure 8. Heritage@ Premium (Frederick) 4 Nail Pattern (non-HVHZ only) Figure 9. Heritage@ Premium (Frederick) 6 Nail Pattern FL18355-R4 6of11 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. I J CREEK TECHNICAL SERVICES, LLC Her tage® Woodgate Basic Wind Speed (V„ it): (Frederick) Basic Wind Speed (Vasa) Deck (Non-HVHZ): Underlayment: ` Min. slope: Installation (Non-HVHZ): I ' -" AMKO BUILDING PRODUCTS Asphalt Shingles Max. 194 mph Max. 150 mph In accordance with FBC requirements; Solidly sheathed min. 15/32 in. plywood or wood plank for new construction; Min. 7/16 in. OSB existing construction. In accordance with FBC requirements. 2:12 and in accordance with FBC requirements. Refer to the manufacturer's application instructions when installing shingles at slopes greater than 21:12. Installed with 5 in. exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either 'A Nail Pattern" or °6 Nail Pattern" detailed below. QNQ' Figure 10. Heritage® Woodgate (Frederick) 4 Nail Pattern (non-HVHZ only) .1.IF-Gt��iQti710' 7jf'►�j? R"fL'.:It n Figure 11. Heritage® Woodgate (Frederick) 6 Nail Pattern TBP15001.4 FL18355-R4 Page 7 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. i I CREEK TECHNICAL SERVICES, LLC i Heritage® Vintage® (Phillipsburg) Basic Wind Speed (V„ it): Basic Wind Speed (Vnd): Deck (HVHZ): Deck (Non-HVHZ) Underlayment: Min. slope: Installation (HVHZ): Installation (Non-HVHZ): AMKO BUILDING PRODUCTS Asphalt Shingles Max. 194 mph Max. 150 mph In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. In accordance with FBC requirements; Solidly sheathed min. 15/32 in. plywood or wood plank for new construction; Min. 7/16 in. OSB existing construction. In accordance with FBC requirements. 2:12 and in accordance with FBC requirements. Refer to the manufacturer's application instructions when installing shingles at slopes greater than 21:12. Installed with 5 in. exposure in accordance with RAS 115 and manufacturer's published installation instructions. Shingles shall be attached using "6 Nail Pattern" detailed below. Installed with 5 in. exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either "5 Nail Pattern" or "6 Nail Pattern" detailed below. Figure 12. Heritage® Vintage® 5 Nail Pattern (non-HVHZ only) Figure 13. Heritage® Vintage® 6 Nail Pattern TBP15001.4 FL18355-R4 Page 8 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. I � ! CREEK :,MKO BUILDING PRODUCTS Shingles Asphalt {{ TECHNICAL SERVICES, LLC Hip I& Ridge Basic Wind Speed (V„ ic): Max. 194 mph (Frederick & Joplin) Basic Wind Speed (Vasd): Max. 150 mph Deck (HVHZ): In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for f new construction; Min. 15/32 in. plywood existing construction. Deck (Non-HVHZ): In accordance with FBC requirements; Solidly sheathed min. 15/32 in. plywood or wood plank for new construction; Min. 7/16 in. OSB existing construction. Underlayment: In accordance with FBC requirements. Min. slope: 2:12 and in accordance with FBC requirements. Installation: Installed with 5-1/8 inch exposure in accordance with the FBC and manufacturer's published installation instructions. The direction of the exposed end shall be away from the prevailing wind. Direction prevailing wind 1/8" exposure Figure ✓ `� astenelr Figure 2 Figure 14. Hip & Ridge (Frederick & Joplin) Dxposure TBP15001.4 FL18355-R4 Page 9 of 11 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC Vintage@ Hip & Ridge Basic Wind Speed (V,,it): (Phillipsburg) Basic Wind Speed (Vasd) Deck (HVHZ): Deck (Non-HVHZ): Underlayment: Min. slope: Installation: AMKO BUILDING PRODUCTS Asphalt Shingles Max. 194 mph Max. 150 mph In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. In accordance with FBC requirements; Solidly sheathed min. 15/32 in. plywood or wood plank for new construction; Min. 7/16 in. OSB existing construction. In accordance with FBC requirements. 2:12 and in accordance with FBC requirements. Installed with 5 inch exposure in accordance with the FBC and manufacturer's published installation instructions. The direction of the exposed end shall be away from the prevailing wind. Direction n_of prevailing wind ire :i=i'gure 1 (posure. '„ 1" Fastener Faster Figure 2 1!4 :Figure 3 Figure 15. Vintage® Hip & Ridge (Phillipsburg) TBP15001.4 FL18355-R4 Page 10 of 11 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes .that are not specific Ially addressed herein. CREEK _ AMKO BUILDING PRODUCTS Asphalt Shingles TECHNICAL SERVICES, LLC LIMITATIONS i k1) Fire Classification is not within the scope of this evaluation. 2) The roof deck and the roof deck attachment shall be designed by others to meet the minimum design loads established for components and cladding and in accordance with FBC requirements. j3) The mean roof height shall be restricted to a maximum 33 ft in the HVHZ. 4) Classification to ASTM D 7158 applies to exposure B & C with a building mean roof height of 60-ft or less. 5) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to underlayment application. ,6) Shingles shall be installed starting at the eave in horizontal layers such that the laps shed water from the deck. 7) Installation of the evaluated products shall comply with this report, the FBC, and the manufacturer's i published application instructions. Where discrepancies exist between these sources, the more restrictive and code compliant detail shall prevail. 8) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 G20-3. PLIANCE STATEMENT The 'products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code, 6t' Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer. >�G�,P ...... 9i '�. No 74021 13 STATE OF 441 C? ,O N AI- 1%s FICATION OF INDEPENDENCE .2017.09.25 11:31:41 -04'00' Zachary R. Priest, P.E. Florida Registration No. 74021 Organization No. ANE11669 i CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation. I Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products underlthis evaluation. I Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. END OF REPORT TBP15001.4 FL18355-R4 Page 11 of 11 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. I