HomeMy WebLinkAboutBLOWER DOOR TEST FORM - 10-14-1910/171/2019 10:26 7724C-aq?56 BEAN DRYWALL,i 4 PAGE 01/05
i
. A
Date: i
Contractor:
Job Address.
Construction:
Planning & Development Services
Building & Code Regulation Division
2300 Virginia Ave, Rm 201
Fort Pierce, FL 34982
.Phone; 772-462.2ir2S Fax: 772-462-6443
BLOWIER ®®OR TEST FORM
SC'� V
House Infiitration Test Certification St Lucie
Prescriptive and Performance Method C�Unty
Permit #: l o �� 0 -1 it.
(%--j' New Construction — Coirnplete
C 3
Exist ng — After Addition
Housb infiltrration Test Resui' SLC Climate Zone 2
CFM 650) Test Date. - f Y,-I(li
volume "7
ACH (50) = CFM (50) x 60 f Volume - - Mechanical Ventilation required less than 8 ACH
Passi g results must be & ACH (50) or less (�) pass ( ) Fall
i
FBC, Energy
The building or dwelling unit shall be tested and verified as having an air lealcage rate of not exceeding Z air changes per
hour Inj Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through S. Testing shall be conducted with a
blowerldoor at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either individuals as defined'In
Sectionl553.993(s) or (7), Florida Statutes or individuals licensed as set forth in Section 489,105 (3)(f), (g) or (1) or an
approved third party. ,A written report of the results of the test shall be signed by the party conducting the test and
provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building
thermal envelope.
FBC, Residential
Where the air Infiltration rate of a dwelling unit is less than 3 air changes per hour when tested with a blower door at a
pressure of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida Building We, Energy Conservation
the dwelling unit shall be provided with whole -house mechanical ventilation In accordance with Section M1507.3.
I •
Testing Company
Company Name: Pro -Duct Services Address: 1995 Rio Vista Drive, Ft. pierce. FL 34949
.1
I hereby certify that the above House Infiltration results demonstrate compliance with FBC Energy Conservation
requirements in accordance with Section R402.4.1.2 Climate Zone 2.
Signature:
I
Printed Name: Markin Klein
license/ � ertificatlon #: 5061633
f;
>1
i
10/17/2019 10:26 7724FAR956
BEAN DRYWALL, i$
PAGE 02/05
R
Planning & Development Services
Building & Code Regulation Division
2300 Virginia Ave, Rm 201
Fort Pierce, FL 34982
Phane, 772-4162 2365 Fax: 772-462-6443
BLOWER DOOR TEST FORM
House Infiitrattion Test Certification
Prescriptive and Performance Method
I •
Date:(
CiDntractar: o �.
Job Aldress: s
Construction:
I •
'9t4�, )e
�OUn
Permit #: 1 P _ 0 -1
(✓ New Construction Complete ( ) Existing —After Addition
Wouse� Infiltration Test Results SLC Climate Zone 2
CFM (50) = 1 0a Test pate:
iiolume = _ i 3 ' ACH (50) a CFM (50) x 60 / Volume = [ " Mechanical Vendlarton required less than 3 ACH
Passing results must be & ACH (30) or less M Pass { ) Fail
i
FBC, £ndrgy
The building or dwelling unit shall betested and verified as having an air leakage rate of not exceeding 7 air changes per
hour In Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through S. Testing shall be conducted with a
blower door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either Individuals as defined in
Section 553.993(5) or (7), Florida Statutes or individuals licensed asset forth In Section 489.105 (3)(f),. (g) or (i) or an
approved third party. A written report of the results of the test shall be signed by the party conducting the test and
provided to the code QJ57 ial. Testing shall be performed at any time after creation of all penetrations of the building
FBC, lle"dantlal
Where the air infiltration rate of a dwelling unit is less than lair changes per hour when tested with a blower door at a
pressure; of 0.2 inch w. c. (50 Pa) in accordance With Section R402.4-1.2 of the Florida Building Code, Energy Conservation .
the dwelling unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3.
I
Testing Companv
Company Name: Pro -Duct Services Address: 1915 Rlo Vista Drive, Ft Pierce, FL 34949
I hereby certlfy that the above House Infiltration results demonstrate compliance with FBC Energy Conservation
requlrernients. in accordance with Section R402.4.1.2 Climate Zone 2'.
{ ^ A _' /t 9
Printed Name: Martin Klein
#: 5061633