Loading...
HomeMy WebLinkAboutSOIL NUCLEAR GAUGE REPORTS - 3 TOTALU-J;Iti`— ��o V Port St. Lucie FBPECA#4930 .-46 607NWCommodity Cove �� Port St. Lucie, FL 34986 Q Phone: 772-924-3575 1 Fax: 772-924-3580 • Soil Nuclear Gauge Report Date: 2/12/2019 Test Method: ASTM D 6938 Client: Southern City Development, LLC 5900 Silver Oak Drive Fort Pierce, FL 34982 Project: 19-1153.00 Southern City Development 2019 Master Agreement Various Locations FL Test Results Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture N Maximum Dry Density (pcf) In Place Moisture N In Place Dry Density (pcf) Probe Depth (in) Percent Compaction Min/Max Comp. N Remark 51 2/8/19 8816 D1557 N/A 11.1 105.5 9.9 104.4 12 99 95 / 105 Pass 52 2/12/19 8816 D1557 N/A 11.1 105.5 10.0 102.7 12 97 95 / 105 Pass 53 2/12/19 8816 D1557 N/A 11.1 1 105.5 1 8.6 1 102.8 1 12 1 97 1 95 / 105 1 Pass 54 2/12/19 8816 D1557 N/A 11.1 1 105.5 1 9.2 1 103.0 1 12 1 98 1 95 / 105 1 Pass Test Information Test # Test Location Elevation Reference Gauge Make / Model / SN / Calibrated Field Technician 51 Above Stripped Surface: Dixieland Town homes, Building 3, 265 & 267 Dixieland Drive, Ft Pierce, Center. 2-3' Troxler / T3430 / 34784 / Evans, Amber 52 Above Stripped Surface: Dixieland Town homes, Building 3, 265 & 267 Dixieland Drive, Ft Pierce, SW corner. 3-4' Troxler / T3430 / 34784 / Evans, Amber 53 Above Stripped Surface: Dixieland Town homes, Building 3, 265 & 267 Dixieland Drive, Ft Pierce, NE comer. 3-4' Troxler / T3430 / 34784 / Evans, Amber 54 JAbove Stripped Surface: Dixieland Town homes, Building 3, 265 & 267 Dixieland Drive, Ft Pierce, Center. 3-4' Troxler / T3430 / 34784 / Evans, Amber Remarks Comments Pass: Tests results comply with specifications Tests are "Direct Transmission" (Method A) unless probe depth is noted as 1"Backscatter". Gauge calibration data on file with the testing agency. \111111111///// .�`���O�N• KFNT�'% � ••�ICENSF % 6 18 � = r I}2/1212019 -------------- ri• Ken ; P.E. P s�fe4ionai*lgirieer#E� 8 sra ONAL �\\G�` 0111111j1 Test Reports shall not be reproduced, except in full, without the written approval of GFA International Inc. Digitally signed printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Page 2 of 2 3 �.r•••woc F Port St. Lucie _ FBPE CA # 4930 607 NW Commodity Cove Port St. Lucie, FL 34986 Phone: 772-924-3575 1 Fax: 772-924-3580 Soil Nuclear Gauge Report Date: 3/19/2019 Test Method: ASTM D 6938 Client: Southern City Development, LLC 5900 Silver Oak Drive Fort Pierce, FL 34982 Project: 19-1153.00 Southern City Development 2019 Master Agreement Various Locations FL Test Results Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture N Maximum Dry Density (pcf) In Place Moisture N In Place Dry Density (pcf) Probe Depth (in) Percent Compaction Min/Max Comp. M) Remark 76 3/18/19 8866 - T180 N/A 10.6 114.6 8.8 113.9 12 99 98 / 105 Pass 77 3/18/19 8866 - T180 N/A 10.6 114.6 10.4 113.2 12 99 98 / 105 Pass 78 3/18/19 8866 - T180 N/A 10.6 114.6 9.8 114.1 1 12 100 98 / 105 Pass 79 1 3/18/19 8866 - T180 N/A 10.6 114.6 8.9 113.9 12 99 98 / 105 Pass Test Information Test # Test Location Elevation Reference Gauge Make / Model / SN / Calibrated Field Technician 76 Footing: Dixieland, Building 3, Permit 18100712, E Side 0-1 Troxler / T3430 / 36304 / Smith, Johnnie 77 Footing: Dixieland, Building 3, Permit 18100712, W Side 0-1 Troxler / T3430 / 36304 / Smith, Johnnie 78 Footing: Dixieland, Building 3, Permit 18100712, N Side 0-1 Troxler / T3430 136304 / Smith, Johnnie 79 Footing: Dixieland, Building 3, Permit 18100712, S Side 1 10-1 Troxler / T3430 136304 / Smith, Johnnie Remarks Comments P1,) 1 \-- 'o Pass: Tests results comply with specifications Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. c-t G�0 d �ONN• KEiVT No 632 _ 4AJAKent,V.E. 03/19f2019 Vftisiorv%Wfi +oeer•# -�j298 ZONAL `E Test Reports shall not be reproduced, except in full, without the written approval of GFA International Inc. Digitally signed printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Page 1 of 1 l R�roll"® Soil Nuclear Gauge eQan',teport Date: 4/1/2019 e Est i� ie___ _ Co lest Method: ASTM D 6938 FBPE CA # 4930 607 NW Commodity Cove Port St. Lucie, FL 34986 Phone: 772-924-35761 Fax: 772-924-3580 / e / t? - 0 ) 12--, Client: Southern City Development, LLC 5900 Silver Oak Drive Fort Pierce, FL 34982 Project: 19-1153.00 Southern City Development 2019 Master Agreement Various Locations FL Test Results Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture N Maximum Dry Density (pcf) In Place Moisture N In Place Dry Density (pcf) Probe Depth (in) Percent Compaction Min/Max Comp. (°/,) Remark 43 2/6119 8816 D1557 N/A 11.1 105.5 9.0 104.1 12 99 95 / 105 Pass 44 2/6/19 8816 D1557 N/A 11.1 105.5 9.6 104.0 12 99 95 / 105 Pass 45 2/6/19 8816 D1557 N/A 11.1 105.5 9.4 103.9 12 98 95 / 105 Pass 46 2/7/19 8816 D1557 N/A 11.1 105.5 9.3 103.6 12 98 95 / 105 Pass 47 2/7119 8816 D1557 N/A 11.1 105.5 10.6 104.0 12 99 95 / 105 Pass 48 217/19 8816 D1557 N/A 11.1 105.5 9.5 104.4 12 99 95 / 105 Pass 49 2/8/19 8816 D1557 N/A 11.1 105.5 10.0 104.3 12 99 95 / 105 Pass 50 2/8/19 8816 D1557 N/A 11.1 1 105.5 9.0 103.9 12 98 1 95 / 105 1 Pass Test Information Test # Test Location Elevation Reference Gauge Make / Model / SN / Calibrated Field Technician 43 Above Stripped Surface: Dixieland Town homes, Building 3, 265 & 267 Dixieland Drive, Ft Pierce, NE corner. Permit 18100712 0-1' Troxler / T3430 / 34784 / Evans, Amber 44 Above Stripped Surface: Dixieland Town homes, Building 3, 265 & 267 Dixieland Drive, Ft Pierce, SW corner. Permit 18100712 0-1' Troxler / T3430 / 34784 / Evans, Amber 45 Above Stripped Surface: Dixieland Town homes, Building 3, 265 & 2679 Dixieland Drive, Ft Pierce, Center. Permit 18100712 0-1' Troxler / T3430 / 34784 / Evans, Amber 46 Above Stripped Surface: Dixieland Town homes, Building 3, 265 & 267 Dixieland Drive, Ft Pierce, Center. Permit 18100712 1-2' Troxler / T3430 134784 / Evans, Amber 47 Above Stripped Surface: Dixieland Town homes, Building 3, 265 & 267 Dixieland Drive, Ft Pierce, NW comer. Permit 18100712 1-2' Troxler / T3430 / 34784 / Evans, Amber 48 Above Stripped Surface: Dixieland Town homes, Building 3, 265 & 267 Dixieland Drive, Ff Pierce, SE comer. Permit 18100712 1-2' Troxler / T3430 / 34784 / Evans, Amber 49 Above Stripped Surface: Dixieland Town homes, Building 3, 265 & 267 Dixieland Drive, Ft Pierce, SW corner. Permit 18100712 2-3' Troxler / T3430 / 34784 / Evans, Amber 50 Above Stripped Surface: Dixieland Town homes, Building 3, 265 & 267 Dixieland Drive, Ft Pierce, NE comer. Permit 18100712 2-3' Troxler / T3430 / 34784 / Evans, Amber Remarks Comments Pass: Tests results comply with specifications Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. Test Reports shall not be reproduced, except in full, without the written approval of GFA International Inc. Page 1 of 2 Digitally signed printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. %-1 •