Loading...
HomeMy WebLinkAboutEVALUATION REPORT - ROOF TILESEXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization #9503 353 CHRISTIAN STREET, UNIT#13 TRINITYERD OXFORD, CT 06478 (203) 262-9245 EVALUATION REPORT t Entegra Roof Tile, LLC Evaluation Report E39310.11.11-1-R4 +f FL1 1289 NE 9" Avenue _ Date ofissuance: ll/02/20/02/2011 F� (D C) F T I I_ f- Okeechobee, FL 34972 Revision 4.10/17/2017 (602)515-6933 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use o construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6th Edition (2017) Florida Buuiiilig� odd® (HVHZ)lsections noted herein. BY DESCRIPTION: Entegra Concrete Roof Tiles (HVHZ jurisdictions) St Lucie County LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity IERD requires a complete review. of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 8. Pre aced by: p :4= %9 ' •'-' ' - ' A - The facsimile seal appearing was authorized by Robert Nleminen, �_ 7 %�L e-7 P.E. on 10/17/2017. This does not serve as an electronically signed 45'" • ? document. signed, sealed Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida OCA ANE1983 ��jj;;�� ;;..�'`�' Product Approval Administrator and to the named diem CERTIFICATION OF INDEPENDENCE: 1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinityl ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. ial interest in any company manufacturing or distributing products for 3. Robert Nieminen, P.E. does not have nor will acquire, a financ which the evaluation reports are being issued. cial interest in any other entity involved in the approval process of the 4. Robert Nieminen, P.E. does not have, nor will acquire, a finan product. 5. This is a building code evaluation. Neither Trinityl ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. '' TRINITYER® ROOFING SYSTEM EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Roofing Tiles Compliance Statement: Entegra Concrete Roof Tiles, as produced by Entegra Roof Tile, LLC, have demonstrated compliance with the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1523.6.5.2 Physical Properties TAS 112 1995 1523.6.5.2 Wind Driven Rain TAS 100 1995 1523.6.5.2.2 Static Uplift Resistance TAS 101 1995 1523.6.5.2.3 Static Uplift Resistance TAS 102 1995 1523.6.5.2.3 Static Uplift Resistance TAS 102(A) 1995 3: '-REFERENCES: Entity Examination Reference Date ERD (TST6049) TAS 101 P39740.02.12 02/21/2012 ATL(TST3782) Physical Properties RT0624.05-14 07/03/2014 ATL (TST3782) Physical Properties RT0624.04-14 07/07/2014 ATL (TST3782) Physical Properties RT1210.02-15 12/17/2015 ATL (TST3782) Physical Properties RT1210.03-15 12/17/2015 ATL (TST 3782) Physical Properties RT1103.01-15 11/07/2015 ATL (TST 3782) Physical Properties RT1103.02-15 11/07/2015 ATL (TST 3782) Physical Properties RT1103.03-15 11/07/2015 ATL (TST 3782) Physical Properties RT1103.04-15 11/07/2015 j ATL (TST 3782) Physical Properties RT1103.05-15 11/07/2015 Miami -Dade (CER1592) HVHZ Compliance 14-0416.12 11/27/2014 Miami -Dade (CER1592) HVHZ Compliance 15-0721.04 11/05/2015 Miami -Dade (CER1592) HVHZ Compliance 16-0112.06 02/25/2016 Miami -Dade (CER1592) HVHZ Compliance 16-0112.07 02/25/2016 Miami -Dade (CER1592) HVHZ Compliance 16-0112.08 02/25/2016 Tile Roof Institute TAS 100, TAS 101, 102, 102(A) Membership Confirmation Current PRI (QUA9110) Quality Assurance Service Confirmation Exp. 11/02/2018 Exterior Research and Design, LLC, Evaluation Report E39330.11.11-1-R4 Certificate of Authorization #9503 6TM EDITION (2017) FBC HVHZ EVALUATION FL7804-R10 Entegra Roof Tiles Revision 4:10/17/2017 Page 2 of 8 4. PRODUCT DESCRIPTION: 4.1 �TA5112 T.VDe TRINITY, ERD _ I BERMUDA FLAT, PLANTATIONFLAT and Bermuda Flat r10151-11— - --- Exterior Research and Design, I.I.C.Evaluation Report E39310.11.11-1-R4 6EDITION 2017 FBC HVHZ EVALUATION FL7804-R30 [eni�cate of AuthorfzaUon g9503 Entegra Roof Tiles Revision 4: 10/17/2017 Page 3 of 8 TRINI 4.2 TAS 112, Type la_ (interlocking, high -profile) - BELLA HIGH "S" ` Galena Spanish "S" Regal Exterior Research and Design, U.C. Evaluation Report E39330.11.11-1-R4 CertlfJcate ofAuthadzation #9503 6TM EDITION (2017) FBC HVHZ EVALUATION FL7804-R10 Entegra Roof Tiles Revision 4: 10/17/2017 Page 4 of 8 E�� ]TRINITY 5. LIMITATIONS: rinity�ERD nor Robert Nieminen, P.E. are, in any way, the 5-1 This is a building code evaluation. Neither T Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. '5.2 This Evaluation Report is for use in FBC HVHZ jurisdictions or others adopting FBC HVHZ requirements. 5.3 Fire classification is not part of this evaluation; refer to FBC 1516 or listing by an approved testing agency for fire rating of this product. 5.4 Reference is made to FBC 1512.4.2.4 regarding field testing of completed tile roof installations. 5.5 Applicant shall retain the services of an FBC listed, accredited laboratory to perform quarterly tests in accordance with TAS 112, Appendix'A'. 5.6 Minimum underlayment shall comply with the RAS 118, RAS 119 or RAS 120, as applicable. Underlayment products shall hold current Florida Statewide Product Approval or Local Approval for use in tile roof assemblies in FBC HVHZ jurisdictions. 5.7 Minimum roof deck requirements shall be in accordance with applicable FBC HVHZ requirements. 5.8 All products in the roof assembly shall have quality assurance audit in accordance with the F.A.C. Rule 61G20-3. 6. INSTALLATION: 6.1 Entegra Concrete Roof Tiles may be mechanically fastened, mortar -set or adhesive -set. Installation shall comply with manufacturer's current published instructions, but not less than the requirements of RAS 118, RAS 119 or RAS 120, as applicable. 6.2 Attachment Calculations: Entegra Concrete Roof Tile shall be evaluated as a 'Moment -Based System' in accordance with Roofing Application Standard RAS 127-11 using the data outlined herein. TABLE 1: AERODYNAMIC MULTIPLIERS-. Tile Batten Application Direct -Deck Application ' 0.205 Bermuda Fla 0.189 0 289 Plantation 0.267 0.330 Horizon FI t 0.305 0.349 0.378 Bella High "S" 0.289 Estate "S„ 0.267 0.289 Hacienda 0.267 NA 0.235 Galena Spanish "S" Regal, / 0.287 0.311 TABLE 2.- RESTORING;MOMENTDUE TO GRAVITY 4- IVI� (FT"LBF)-• :.= Roof Slope (0) Tile 2:12<0<3:12 3:12<0<4:12 4:12<0<5:12 5:12<0<6:12 612<0<7:12 0>7:12 Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct Bermuda Flat 5.17 6.37 5.09 6.27 4.98 6.15 4.86 6.00 4.72 5.83 6.85 7.79 6.75 7.67 6.61 7.52 6.44 7.32 6.26 7.04Horizon Plantation Flat r6.43 7.528.24 7.41 8.12 7.26, 7.95 7.09 7.76 6.89 7.55Bella High "S" 6.19 . 6.11 6.80 5.99 6.67 5.85 6.51 5.68 6.33 5.50 6.13 Estate "S" 6.14 6.84 5.91 6.74 5.82 6.64 5.70 6.50 5.56 6.33 5.40 6.14 5.92 6.80 5.92 6.80 5.82 6.69 5.70 6.55 5.56 6.39 5.41 6.22 Hacienda N/A 7.77 6.20 1 8.34 N/A 7.77 6.13 8.34 N/A 7.65 6.03 8.20 N/A 7.49 5.89 8.03 N/A 7.30 5.74 7.83 N/A 7.10 5.57 7.61 Galena Spanish "S" Regal Exterior Research and Design, I.I.C. CertiJfcateofAuthorization7t9503 6n{ EDITION 2017 FBC HVHZ EVALUATION 1 Entegra Roof Tiles Evaluation Report E39310.11.11-1-R4 FL7804-R10 Revision 4:10/17/2017 Page 5 of 8 v R TRINITY + ERD TABLE3A ATTACHMENT RESISTANCE EXPRESSED AS A MOMENT MF (FT LBF) . , - MECHANICALLY ATTACHED SYSTEMS Tile Fastener Direct -Deck (min.15/32" plywood) Direct -Deck (min.19/3Z" plywood) Battens Type # Size Shank Gip Nail One (1) 10d Smooth or Screw N/A 7.3 9.8 4.9 Nail Two (2) 10d Smooth or Screw N/A 14.0 18.8 7.4 Nail One (1) lod Smooth or Screw Eave 19.0 19.0 22.1 Nail One (1) 10d Smooth or Screw Field 24.3 24.3 24.2 BermudaDat, Nail Two (2) lod Smooth or Screw Eave 31.9 31.9 32.2 Plantatior Nail Two (2) 10d Smooth or Screw Field 35.5 35.5 34.8 Horizon Nail Two (2) lod Ring N/A 1 30.9 38.1 17.2 Nail' Two (2)1 10d' Ring' N/A 50.3' 65.5' 48.3' Screw One (1) #8 N/A N/A 30.8 30.8 18.2 Screw Two (2) #8 N/A N/A 51.7 51.7 24.4 1Installation with a 4-inch tile headlap and fasteners located min. 2'F,-inch from head of tile. Nail One(1)2 10d Smooth or Screw N/A 8.82 11.82 4.12 Nail Two (2) 10d Smooth or Screw N/A 16.4 21.9 7.1 Nail One lod Smooth or Screw Eave 19.02 19.02 22.12 Nail One 10d Smooth or Screw Field 24.32 24.32 24.22 Nail Two (2) 10d Smooth or Screw Eave 31.9 31.9 I .32.2 Estate "S" or Hacienda Nail Two (2) 10d Smooth or Screw Field 35.5 35.5 I 34.8 Nail Two (2) 10d Ring N/A 27.8 37.4 1 28.8 Nail' Two (2)' lod' Ring' N/A 43.01 67.5' 50.9, Screw One #8 N/A N/A 25.82 25.82 22.92 Screw Two (2) #8 N/A N/A 47.1 47.1 49.1 1Installation with a 4-inch tile headlap and fasteners located min. 2%-inch from head of tile. 2 For one (1) fastener installations, utilize hole that is approximately 4%-inch from the interlocking edge. Nail One (1) 10d Smooth or Screw N/A 5.1 6.8 2.8 Nail Two (2) 10d Smooth or Screw N/A 6.9 9.2 7.3 Nail One (1) 10d Smooth or Screw Field 23.1 23.1 I .19.0 Nail One (1) 10d Smooth or Screw Eave 29.3 29.3 24.0 Nail Two (2) 10d Smooth or Screw Field 27.6 27.6 38.6 Bella High "S", Galena Spanish "S" or Regal Nail Two (2) 10d Smooth or Screw Eave 38.1 38.1 41.8 Nail Two (2) 10d Ring N/A 28.6 41.2 19.4 Nail' Two (2)' 10d' Ring' N/A 33.1' 48.1' 50.91 Screw One (1) #8 N/A N/A 20.7 20.7 18.1 Screw Two (2) #8 N/A N/A 43.2 43.2 29.8 1Installation with a 4-inch the headlap and fasteners located min. 2X-inch from head of tile. Exterior Research and Design, U.C. Certificate of Authorization #9503 6'N EDITION (2017) FBC HVHZ EVALUATION Entegra Roof Tiles Evaluation Report E39330.11.11-1-R4 FL7804-R10 Revision 4:10/17/2017 Page 6 of 8 i' •''` 1 i �' - -'` sf RII�IIT1Pr ERD TA LE ATTACHMENT RESISTANCE EXPRESSED AS A MOMENT— MF (FT-LBF)' MORTAR AND ADHESIVE -SET SYSTEMS y Note -from `Entegra Roof Tile,: LLC": The performance data listed in. Table 4 are based omthe respective adhesive manufacturers' test. reports -and Miami -Dade NOAs. Entegra Roof Ti LLC. relies upon the adhesive manufacturers to provide these values for our, inclusion , in this F8C NI/HZ Evaluation Report Please consult the individual adhesive manufacturer for information on product approvals,-' limitations, revisions or other information for'determining: wind logd-and overturning moment performgrice. ' Tile Adhesive Tile Product Product Approval Placement Mf (ft-lbf) "TILE BOND'""" by Dow Chemical NOA 16-0222.01 Interdependent (2-paddy) 41 Bermuda "Touch N' Seal Storm Bond" by DAP Foam NOA 16-0421.03 Interdependent (2-paddy) 73 Flat, I "Polyset® RTA-1" by ICP Adhesives & Sealants NOA 16-0315.03 Interdependent (2-paddy) 52 Plantation Flat or Horizon "Polyset® AH-160" by ICP Adhesives & Sealants NOA 17-0322.03 Interdependent (2-paddy) 43 Independent (medium paddy, —30 g) 51 Independent (large paddy, ^'45 g) 92 "TILE BONDTM" by Dow Chemical NOA 16-0222.01 Interdependent (2-paddy) 44 "Touch N' Seal Storm Bond" by DAP Foam NOA 16-0421.03 Interdependent (2-paddy) 42 "Polyset® RTA-1" by ICP Adhesives & Sealants NOA 16-0315.03 Interdependent (2-paddy) 44 Estate "S" or Hacienda "Polyset® AH-160" by ICP Adhesives & Sealants NOA 17-0322.03 Interdependent(2-paddy) 50 Independent (medium paddy, —30 g) 37 Independent (large paddy, ^'54 g) 61 Mortar Various Per RAS 120 21 "TILE BOND'" by Dow Chemical NOA 16-0222.01 Interdependent (2-paddy) 48 "Touch N' Seal Storm Bond" by DAP Foam NOA 16-0421.03 Interdependent (2-paddy) 52 Bella: High "Polyset® RTA-1'.' by ICP Adhesives & Sealants NOA 16-0315.03 Interdependent (2-paddy) 36 "S", Galena Spanish "S" or Regal "Polyset® AH-160" by ICP Adhesives & Sealants NOA 17-0322.03 Interdependent (2-paddy) 30 Independent (medium paddy, ^30 g) 49 Independent (large paddy, —63 g) 94 Mortar Various Per RAS 120 25 7, i LABELING: 7.1 Each unit shall bear the imprint and/or identifiable marking of the manufacturer's name or logo, as detailed below. Tile lots shall be labeled in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. . I and/or E N T E U R R Labeling: Bermuda Flat, Plantation Flat, Estate "S", Bella High "S", Galena Spanish "S" Exterior Research and Design, I.I.C. Evaluation Report E39330.11.11-1-R4 Certificate of Authorization #9503 6T" EDITION (2017) FBC HVHZ EVALUATION FL7804-R10 Entegra Roof Tiles Revision 4:10/17/2017 Page 7 of 8 8. 9. JL and/or Hanson Labeling: Horizon Flat, Hacienda, Regal BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. MANUFACTURING PLANTS: Okeechobee, FL Bermuda Flat, Plantation Flat, Estate "S", Bella High "S", Galena Spanish "S" Ft. Myers, FL Horizon Flat, Hacienda Deerfield Beach, FL Horizon Flat, Hacienda, Regal 10. QUALITY ASSURANCE ENTITY: PRI Construction Materials Technologies, LLC. — QUA9110; (813) 621-5777 - END OF EVALUATION REPORT — Exterior Research and Design, LLC. Evaluation Report E39310.11.31-i-R4 Certificate of Authorization #9503 6EDITION (2017) FBC HVHZ EVALUATION FL7804-R10 Entegra Roof Tiles Revision 4: 10/17/2017 Page 8 of 8