HomeMy WebLinkAboutEVALUATION REPORT - ROOF TILESEXTERIOR RESEARCH & DESIGN, LLC.
Certificate of Authorization #9503
353 CHRISTIAN STREET, UNIT#13
TRINITYERD OXFORD, CT 06478
(203) 262-9245
EVALUATION REPORT
t Entegra Roof Tile, LLC Evaluation Report E39310.11.11-1-R4
+f FL1
1289 NE 9" Avenue
_ Date ofissuance: ll/02/20/02/2011
F� (D C) F T I I_ f- Okeechobee, FL 34972 Revision 4.10/17/2017
(602)515-6933
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use o
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 6th Edition (2017) Florida Buuiiilig� odd®
(HVHZ)lsections noted herein.
BY
DESCRIPTION: Entegra Concrete Roof Tiles (HVHZ jurisdictions) St Lucie County
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the
referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change.
Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the
product changes or the referenced Quality Assurance documentation changes. Trinity IERD requires a complete
review. of this Evaluation Report relative to updated Code requirements with each
Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 8.
Pre aced by:
p
:4=
%9 ' •'-' ' - ' A - The facsimile seal appearing was authorized by Robert Nleminen,
�_ 7 %�L e-7 P.E. on 10/17/2017. This does not serve as an electronically signed
45'" • ? document. signed, sealed
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida OCA ANE1983 ��jj;;�� ;;..�'`�'
Product Approval Administrator and to the named diem
CERTIFICATION OF INDEPENDENCE:
1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinityl ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
ial interest in any company manufacturing or distributing products for
3. Robert Nieminen, P.E. does not have nor will acquire, a financ
which the evaluation reports are being issued.
cial interest in any other entity involved in the approval process of the
4. Robert Nieminen, P.E. does not have, nor will acquire, a finan
product.
5. This is a building code evaluation. Neither Trinityl ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
'' TRINITYER®
ROOFING SYSTEM EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Roofing Tiles
Compliance Statement: Entegra Concrete Roof Tiles, as produced by Entegra Roof Tile, LLC, have demonstrated
compliance with the following sections of the Florida Building Code through testing in accordance with the following
Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth
herein.
2. STANDARDS:
Section
Property
Standard
Year
1523.6.5.2
Physical Properties
TAS 112
1995
1523.6.5.2
Wind Driven Rain
TAS 100
1995
1523.6.5.2.2
Static Uplift Resistance
TAS 101
1995
1523.6.5.2.3
Static Uplift Resistance
TAS 102
1995
1523.6.5.2.3
Static Uplift Resistance
TAS 102(A)
1995
3: '-REFERENCES:
Entity
Examination
Reference
Date
ERD (TST6049)
TAS 101
P39740.02.12
02/21/2012
ATL(TST3782)
Physical Properties
RT0624.05-14
07/03/2014
ATL (TST3782)
Physical Properties
RT0624.04-14
07/07/2014
ATL (TST3782)
Physical Properties
RT1210.02-15
12/17/2015
ATL (TST3782)
Physical Properties
RT1210.03-15
12/17/2015
ATL (TST 3782)
Physical Properties
RT1103.01-15
11/07/2015
ATL (TST 3782)
Physical Properties
RT1103.02-15
11/07/2015
ATL (TST 3782)
Physical Properties
RT1103.03-15
11/07/2015
ATL (TST 3782)
Physical Properties
RT1103.04-15
11/07/2015 j
ATL (TST 3782)
Physical Properties
RT1103.05-15
11/07/2015
Miami -Dade (CER1592)
HVHZ Compliance
14-0416.12
11/27/2014
Miami -Dade (CER1592)
HVHZ Compliance
15-0721.04
11/05/2015
Miami -Dade (CER1592)
HVHZ Compliance
16-0112.06
02/25/2016
Miami -Dade (CER1592)
HVHZ Compliance
16-0112.07
02/25/2016
Miami -Dade (CER1592)
HVHZ Compliance
16-0112.08
02/25/2016
Tile Roof Institute
TAS 100, TAS 101, 102, 102(A)
Membership Confirmation
Current
PRI (QUA9110)
Quality Assurance
Service Confirmation
Exp. 11/02/2018
Exterior Research and Design, LLC, Evaluation Report E39330.11.11-1-R4
Certificate of Authorization #9503 6TM EDITION (2017) FBC HVHZ EVALUATION FL7804-R10
Entegra Roof Tiles Revision 4:10/17/2017
Page 2 of 8
4. PRODUCT DESCRIPTION:
4.1 �TA5112 T.VDe
TRINITY, ERD
_ I BERMUDA FLAT, PLANTATIONFLAT and
Bermuda Flat r10151-11— - ---
Exterior Research and Design, I.I.C.Evaluation Report E39310.11.11-1-R4
6EDITION 2017 FBC HVHZ EVALUATION FL7804-R30
[eni�cate of AuthorfzaUon g9503 Entegra Roof Tiles Revision 4: 10/17/2017
Page 3 of 8
TRINI
4.2 TAS 112, Type la_ (interlocking, high -profile) - BELLA HIGH "S" `
Galena Spanish "S" Regal
Exterior Research and Design, U.C. Evaluation Report E39330.11.11-1-R4
CertlfJcate ofAuthadzation #9503 6TM EDITION (2017) FBC HVHZ EVALUATION FL7804-R10
Entegra Roof Tiles Revision 4: 10/17/2017
Page 4 of 8
E��
]TRINITY
5. LIMITATIONS:
rinity�ERD nor Robert Nieminen, P.E. are, in any way, the
5-1 This is a building code evaluation. Neither T
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used
for permitting or design guidance unless retained specifically for that purpose.
'5.2 This Evaluation Report is for use in FBC HVHZ jurisdictions or others adopting FBC HVHZ requirements.
5.3 Fire classification is not part of this evaluation; refer to FBC 1516 or listing by an approved testing agency for
fire rating of this product.
5.4 Reference is made to FBC 1512.4.2.4 regarding field testing of completed tile roof installations.
5.5 Applicant shall retain the services of an FBC listed, accredited laboratory to perform quarterly tests in
accordance with TAS 112, Appendix'A'.
5.6 Minimum underlayment shall comply with the RAS 118, RAS 119 or RAS 120, as applicable. Underlayment
products shall hold current Florida Statewide Product Approval or Local Approval for use in tile roof
assemblies in FBC HVHZ jurisdictions.
5.7 Minimum roof deck requirements shall be in accordance with applicable FBC HVHZ requirements.
5.8 All products in the roof assembly shall have quality assurance audit in accordance with the F.A.C. Rule
61G20-3.
6. INSTALLATION:
6.1 Entegra Concrete Roof Tiles may be mechanically fastened, mortar -set or adhesive -set. Installation shall
comply with manufacturer's current published instructions, but not less than the requirements of RAS 118,
RAS 119 or RAS 120, as applicable.
6.2 Attachment Calculations: Entegra Concrete Roof Tile shall be evaluated as a 'Moment -Based System' in
accordance with Roofing Application Standard RAS 127-11 using the data outlined herein.
TABLE 1: AERODYNAMIC MULTIPLIERS-.
Tile Batten Application Direct -Deck Application
' 0.205
Bermuda Fla 0.189 0 289
Plantation 0.267 0.330
Horizon FI t 0.305
0.349 0.378
Bella High "S" 0.289
Estate "S„ 0.267
0.289
Hacienda 0.267 NA 0.235
Galena Spanish "S"
Regal,
/
0.287
0.311
TABLE 2.- RESTORING;MOMENTDUE TO GRAVITY 4- IVI� (FT"LBF)-•
:.=
Roof Slope
(0)
Tile
2:12<0<3:12
3:12<0<4:12
4:12<0<5:12
5:12<0<6:12
612<0<7:12
0>7:12
Battens
Direct
Battens
Direct
Battens
Direct
Battens
Direct
Battens
Direct
Bermuda Flat
5.17
6.37
5.09
6.27
4.98
6.15
4.86
6.00
4.72
5.83
6.85
7.79
6.75
7.67
6.61
7.52
6.44
7.32
6.26
7.04Horizon
Plantation Flat
r6.43
7.528.24
7.41
8.12
7.26,
7.95
7.09
7.76
6.89
7.55Bella
High "S"
6.19
.
6.11
6.80
5.99
6.67
5.85
6.51
5.68
6.33
5.50
6.13
Estate "S"
6.14
6.84
5.91
6.74
5.82
6.64
5.70
6.50
5.56
6.33
5.40
6.14
5.92
6.80
5.92
6.80
5.82
6.69
5.70
6.55
5.56
6.39
5.41
6.22
Hacienda
N/A
7.77
6.20
1 8.34
N/A
7.77
6.13
8.34
N/A
7.65
6.03
8.20
N/A
7.49
5.89
8.03
N/A
7.30
5.74
7.83
N/A
7.10
5.57
7.61
Galena Spanish "S"
Regal
Exterior Research and Design, I.I.C.
CertiJfcateofAuthorization7t9503
6n{ EDITION 2017 FBC HVHZ EVALUATION
1
Entegra Roof Tiles
Evaluation Report E39310.11.11-1-R4
FL7804-R10
Revision 4:10/17/2017
Page 5 of 8
v
R TRINITY + ERD
TABLE3A ATTACHMENT RESISTANCE EXPRESSED AS A MOMENT MF (FT LBF) . , -
MECHANICALLY ATTACHED SYSTEMS
Tile
Fastener
Direct -Deck
(min.15/32"
plywood)
Direct -Deck
(min.19/3Z"
plywood)
Battens
Type
#
Size
Shank
Gip
Nail
One (1)
10d
Smooth or Screw
N/A
7.3
9.8
4.9
Nail
Two (2)
10d
Smooth or Screw
N/A
14.0
18.8
7.4
Nail
One (1)
lod
Smooth or Screw
Eave
19.0
19.0
22.1
Nail
One (1)
10d
Smooth or Screw
Field
24.3
24.3
24.2
BermudaDat,
Nail
Two (2)
lod
Smooth or Screw
Eave
31.9
31.9
32.2
Plantatior
Nail
Two (2)
10d
Smooth or Screw
Field
35.5
35.5
34.8
Horizon
Nail
Two (2)
lod
Ring
N/A
1 30.9
38.1
17.2
Nail'
Two (2)1
10d'
Ring'
N/A
50.3'
65.5'
48.3'
Screw
One (1)
#8
N/A
N/A
30.8
30.8
18.2
Screw
Two (2)
#8
N/A
N/A
51.7
51.7
24.4
1Installation with a 4-inch tile headlap and fasteners located min. 2'F,-inch from head of tile.
Nail
One(1)2
10d
Smooth or Screw
N/A
8.82
11.82
4.12
Nail
Two (2)
10d
Smooth or Screw
N/A
16.4
21.9
7.1
Nail
One
lod
Smooth or Screw
Eave
19.02
19.02
22.12
Nail
One
10d
Smooth or Screw
Field
24.32
24.32
24.22
Nail
Two (2)
10d
Smooth or Screw
Eave
31.9
31.9
I .32.2
Estate "S" or Hacienda
Nail
Two (2)
10d
Smooth or Screw
Field
35.5
35.5
I 34.8
Nail
Two (2)
10d
Ring
N/A
27.8
37.4
1 28.8
Nail'
Two (2)'
lod'
Ring'
N/A
43.01
67.5'
50.9,
Screw
One
#8
N/A
N/A
25.82
25.82
22.92
Screw
Two (2)
#8
N/A
N/A
47.1
47.1
49.1
1Installation with a 4-inch tile headlap and fasteners located min. 2%-inch from head of tile.
2 For one (1) fastener installations, utilize hole that is approximately 4%-inch from the interlocking edge.
Nail
One (1)
10d
Smooth or Screw
N/A
5.1
6.8
2.8
Nail
Two (2)
10d
Smooth or Screw
N/A
6.9
9.2
7.3
Nail
One (1)
10d
Smooth or Screw
Field
23.1
23.1
I .19.0
Nail
One (1)
10d
Smooth or Screw
Eave
29.3
29.3
24.0
Nail
Two (2)
10d
Smooth or Screw
Field
27.6
27.6
38.6
Bella High "S", Galena
Spanish "S" or Regal
Nail
Two (2)
10d
Smooth or Screw
Eave
38.1
38.1
41.8
Nail
Two (2)
10d
Ring
N/A
28.6
41.2
19.4
Nail'
Two (2)'
10d'
Ring'
N/A
33.1'
48.1'
50.91
Screw
One (1)
#8
N/A
N/A
20.7
20.7
18.1
Screw
Two (2)
#8
N/A
N/A
43.2
43.2
29.8
1Installation with a 4-inch the headlap and fasteners located min. 2X-inch from head of tile.
Exterior Research and Design, U.C.
Certificate of Authorization #9503
6'N EDITION (2017) FBC HVHZ EVALUATION
Entegra Roof Tiles
Evaluation Report E39330.11.11-1-R4
FL7804-R10
Revision 4:10/17/2017
Page 6 of 8
i' •''` 1
i
�' - -'` sf RII�IIT1Pr ERD
TA LE ATTACHMENT RESISTANCE EXPRESSED AS A MOMENT— MF (FT-LBF)'
MORTAR AND ADHESIVE -SET SYSTEMS y
Note -from `Entegra Roof Tile,: LLC": The performance data listed in. Table 4 are based omthe respective adhesive manufacturers' test.
reports -and Miami -Dade NOAs. Entegra Roof Ti LLC. relies upon the adhesive manufacturers to provide these values for our, inclusion ,
in this F8C NI/HZ Evaluation Report Please consult the individual adhesive manufacturer for information on product approvals,-'
limitations, revisions or other information for'determining: wind logd-and overturning moment performgrice. '
Tile
Adhesive
Tile
Product
Product Approval
Placement
Mf (ft-lbf)
"TILE BOND'""" by Dow Chemical
NOA 16-0222.01
Interdependent (2-paddy)
41
Bermuda
"Touch N' Seal Storm Bond" by DAP Foam
NOA 16-0421.03
Interdependent (2-paddy)
73
Flat, I
"Polyset® RTA-1" by ICP Adhesives & Sealants
NOA 16-0315.03
Interdependent (2-paddy)
52
Plantation
Flat or
Horizon
"Polyset® AH-160" by ICP Adhesives &
Sealants
NOA 17-0322.03
Interdependent (2-paddy)
43
Independent (medium paddy, —30 g)
51
Independent (large paddy, ^'45 g)
92
"TILE BONDTM" by Dow Chemical
NOA 16-0222.01
Interdependent (2-paddy)
44
"Touch N' Seal Storm Bond" by DAP Foam
NOA 16-0421.03
Interdependent (2-paddy)
42
"Polyset® RTA-1" by ICP Adhesives & Sealants
NOA 16-0315.03
Interdependent (2-paddy)
44
Estate "S" or
Hacienda
"Polyset® AH-160" by ICP Adhesives &
Sealants
NOA 17-0322.03
Interdependent(2-paddy)
50
Independent (medium paddy, —30 g)
37
Independent (large paddy, ^'54 g)
61
Mortar
Various
Per RAS 120
21
"TILE BOND'" by Dow Chemical
NOA 16-0222.01
Interdependent (2-paddy)
48
"Touch N' Seal Storm Bond" by DAP Foam
NOA 16-0421.03
Interdependent (2-paddy)
52
Bella: High
"Polyset® RTA-1'.' by ICP Adhesives & Sealants
NOA 16-0315.03
Interdependent (2-paddy)
36
"S", Galena
Spanish "S"
or Regal
"Polyset® AH-160" by ICP Adhesives &
Sealants
NOA 17-0322.03
Interdependent (2-paddy)
30
Independent (medium paddy, ^30 g)
49
Independent (large paddy, —63 g)
94
Mortar
Various
Per RAS 120
25
7, i LABELING:
7.1 Each unit shall bear the imprint and/or identifiable marking of the manufacturer's name or logo, as detailed
below. Tile lots shall be labeled in accordance with the requirements of the Accredited Quality Assurance
Agency noted herein. .
I
and/or
E N T E U R R
Labeling: Bermuda Flat, Plantation Flat, Estate "S", Bella High "S", Galena Spanish "S"
Exterior Research and Design, I.I.C. Evaluation Report E39330.11.11-1-R4
Certificate of Authorization #9503 6T" EDITION (2017) FBC HVHZ EVALUATION FL7804-R10
Entegra Roof Tiles Revision 4:10/17/2017
Page 7 of 8
8.
9.
JL
and/or
Hanson
Labeling: Horizon Flat, Hacienda, Regal
BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
MANUFACTURING PLANTS:
Okeechobee, FL
Bermuda Flat, Plantation Flat, Estate "S", Bella High "S", Galena Spanish "S"
Ft. Myers, FL
Horizon Flat, Hacienda
Deerfield Beach, FL
Horizon Flat, Hacienda, Regal
10. QUALITY ASSURANCE ENTITY:
PRI Construction Materials Technologies, LLC. — QUA9110; (813) 621-5777
- END OF EVALUATION REPORT —
Exterior Research and Design, LLC. Evaluation Report E39310.11.31-i-R4
Certificate of Authorization #9503 6EDITION (2017) FBC HVHZ EVALUATION FL7804-R10
Entegra Roof Tiles Revision 4: 10/17/2017
Page 8 of 8