EXTERIOR RESEARCH «DESIGN, LLC.
Certificate of Authorization #9503
353 CHRISTIAN STREET, UNIT#13
OXFORD, CT 06478
PHONE: (203) 262-9245
FAX: (203) 262-9243
EVALUATION REPOR A SCAN IJEJ)
East Coast Metals, Inc. BY Evaluation Report E10240.08.08-R4
FL5374-R4
2301 West 8 Lane St LUCK C®Untj Date of issuance: 09/03/2008
Hialeah, FL 33010 Revision 4: 03/17/2015
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use o
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for
use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described
herein have been evaluated for compliance with the 51n Edition (2014) Florida Building Code sections noted herein.
DESCRIPTION: East Coast Metals Channel Metals
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the
referenced Quality Assurance documentation changes. Trinity ERD requires a complete review of this Evaluation Report
relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 7.
Prepared by:
RoberJ.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA AIVE1983
The iarsimile seal appearing was authorized by Roben ,,gaminen.
P-E. on 03/17/2015. This dces not serve as an eleGranically signed
document Signed, sealed hardcopies have been transmitted to the
Product Approval Administrator and to the named client
CERTIFICATION OF INDEPENDENCE:
1. i rinityl ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
ny manufacturing or distributing products it evaluates.
2. Trinity I ERD is not owned, operated or controlled by any compa
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
ial interest in any other entity involved in the approval process of the
4. Robert Nieminen, P.E. does not have, nor will acquire, a financ
product.
5. This is a building code evaluation. Neither Trinity) ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
l dun
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Roofing Accessories that are an Integral Part of the Roofing System
Compliance Statement: East Coast Metals Channel. Metals, as produced by East Coast Metals, have demonstrated compliance
with the following sections of the Florida Building`Code through testing in accordance with the following Standards. Compliance
is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein.
2. STANDARDS:
Section
1507.3.7
1518.8.1
1523.6S.2.2
1711.2.1
3. REFERENCES:
Enti
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
Florida TEC (TM393)
PRI (TSr5878)
PRI(TST5878)
PRI(TST5878)
PRI (TST5878)
PRI(TST587S)
PRI(TST5S78)
PRI(TSTS878)
Florida Building Code
Florida Building Code - HVHZ
East Coast Metals
Architectural Testing (QUA1844)
4. PRODUCT DESCRIPTION:
Property
Installation, non-HVHZ
Installation, HVHZ
Static Uplift Resistance
Static Uplift Resistance
Examination
Static Uplift Resistance
Static Uplift Resistance
Static Uplift Resistance
TAS 101
TAS 101
TAS 101
TAS 101
TAS 101
TAS 101
TAS 101
TAS 101
Attachment Requirements
Attachment Requirements
Metal Quality
Quality Control
4.1 Hip & Ridge Channel Metal: Pre -formed metal channel
designed for use as a hip and ridge base to which roof tiles
are bonded in FBC Approved roof the adhesive.
Hip & Ridge Channel Metal is available in 119-3/8-inch (±
3/8-inch) length by 2.5, 3, 3.5, 4, 5, 6 or 7-inch (+ 3/8-inch)
heights with 1.5-inch (T 1/16-inch) deck -flanges.
Standard
FRSA/TRI April 2012 (04-12)
RAS118,119&120
TAS 101
SBCCI SSTD 11
Reference
E42730.08.3
ECNI-SC6795.12.14-1
ECNI-SC6795.12.14-2
S10.62SR
ECM-001-02-02
ECM-003-02-01
ECM-004-02-01
ECNI-005-02-01
ECNI-006-02-01
ECNI-007-02-01
ECM-008-02-01
FRSA/TRI April 2012 (04-12)
RAS 118,119 and 120
Mill Certifications
Participation Letter
Year
2012
1995
1995
1997
Date
08/23/2013
02/27/2015
02/27/2015
10/27/2010
09/21/2001
06/13/2008
06/13/2008
06/13/2008
06/13/2008
06/13/2008
06/13/2008
04/2012
1995
Various
Exp.12J31/2018
I
Exterior Research and Design, I.I.C. Evaluation Report E10240.08.08-R4
Certijaate of Authoriratfan #9503 FL5374-R4
Revision 4: 03/17/2015
Page 2 of 7
4.2 Trim Lock Channel Metal: Pre -formed metal channel
designed for use as a hip arid ridge base to which roof tiles
are bonded in FBC Approved roof the adhesive. Trim Lock
Channel Metal is characterized by its profiled and
perforated upper horizontal flange designed to receive
and allow for interlock with. the overlying tile adhesive.
Trim Lock Channel Metal is available in 119-3/8-inch (}
3/8")length by 3, 3.5, 4, 5 or 6-inch (±.3/8-inch) heights
with 1.5-inch (+ 1/16-inch) deck -flanges.
4.2 Trim Lock Plus Channel Metal: Pre-formedmetal channel
designed for use as a hip and ridge base to which roof tiles
are bonded in FBC Approved roof tile adhesive. Trim Lock
Plus Channel Metal is characterized by its profiled and
perforated upper horizontal flange designed to receive
and allow for interlock with the overlying tile adhesive
and its perforated deck flanges, designed for installation
atop the roof underlayment via placement in FBC
Approved roof tile adhesive, which flows -through and
interlocks with the underlying adhesive.
Trim Lock Plus Channel Metal is available in 119-3/8-inch
(± 3/8") length by 3, 3.5, 4, 5 or 6-inch L 3/8-inch) heights
with 1.5-inch (±1/16-inch) deck -flanges.
4.4 East Coast Metals Channel Metals are fabricated of the following metals:
• Galvanized Steel: Min. 0.019 + 0.002-inch, ASTM A653 (G-90), min. 33 KSI.
r Galvalume Steel: Min. 0.019+ 0.002-inch, ASTM A792, AZ55, min. 35 KSI.
a Aluminum: Min. 0.032 + 0.002-inch, ASTM B209, 3003-1i14, min. 21 KSI.
> Stainless Steel: Min'. 0.019 ± 0.002-inch, ASTM A240/A480, T304, min. 35 KSI.
5. LIMITATIONS:
5.1 This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way, the Designer of
Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or
design guidance unless retained specifically for that purpose.
Exterior Research and Design, I.I.C.Evaluation Report E10240.08.08-R4
FL5374-R4
Certificate of Authorization #9503 Revision 4: 03/17/2015
Page 3 of 7
ERD
5.2 FOR HVHZJURISDICTIONS:
5.2.1 For Hip & Ridge Channel Metal or Trim Lock Channel Metal, refer to FBC RAS 118, Drawing 13, Detail 3; RAS 119,
Drawing 12, Detail 3; or RAS 120, Drawing 15, Detail 3. For Trim Lock:Plus Channel Metal, refer to the installation
instructions herein.
5.2.2 For HVHZ jurisdictions, installations of Hip & Ridge Channel Metal and Trim Lock are prescriptive by RAS 118, 119 and
120, and the data in Tables 1A and 18 is supplemental to these prescriptive allowances.
Installations of Trim Lock Plus are limited to projects having a required moment resistance (M,) or uplift resistance (F,),
as determined in accordance with RAS 127, not greater than the following1values.
Referto the file adhesive manufacturer's published installation instructions for adhesive paddy placement details.
> "INDEPENDENT" paddy placement means each individual tile is bonded to the Channel Metal in its own, single
foam paddy; tile head laps are not bonded. This method is limited to 2-part tile adhesives. Allowable
performance data below for "INDEPENDENT" paddy placement already has a 2 to 1 margin of safety applied to
ultimate performance.
> "INTERDEPENDENT" paddy placement means each individual tile is bonded to the Channel Metal in a foam paddy,
and a second foam paddy bonds the tile head lap, or two tiles are bonded to the Channel Metal using a single
foam paddy. Allowable performance data below for "INTERDEPENDENT" paddy placement already has a 4 to 1
margin of safety applied to ultimate performance.
TABLE IA: PERFORMANCE LIMITATIONS -_HVHZ, INDEPENDENT PADDY PLACEMENT
. (2T03 MARGIN OFSAIM YALREADYAPPLIED)
Hi Ridge Metal
Tile
Adhesive f
Allowable Performance
Desi n
g
Metal T e
YP
Type
Placement
Moment Based
Mr (ft-lbf)
Uplift Based
F' (Ibf)
Hip & Ridge
galvanized
clay or
3M- 2-Component Foam
Independent
127
169
Channel Metal
concrete
Roof Tile Adhesive AH-160
Trim Lock
galvanized, GalvalumeO,
clay or
3M'" 2-Component Foam
Independent
171
is19
aluminum or stainless steel
concrete
Roof Tile Adhesive AH-160
Trim Lock Plus
galvanized, Galvalume°,
clay or
3M"' 2-Component Foam
independent
P
177
6I5
aluminum or stainless steel
concrete
Roof Tile AdhesiveAH-160
TABLE O: PERFORMANCE LIMITATIONS- HVHZrINTERDEPENDENT PADDY PfACEMENT
(4TOI MARGINOFSAFE YALREADYAPPLIEDJ
Hip/Ridge Metal
Tile
Adhesive
Allowable Performance
Design
Metal Type
Type
Placement
Moment Based
Uplift Based
Mr (ft-lbf)
V (Ibf)
Trim Lock or Trim
galvanized, Gaivalume°,
day or
3M"' 2-Component Foam
Interdependent
95
88
Lock Plus
aluminum or stainless steel
concrete
Roof Tile Adhesive AH-160
Trim Lock
galvanized, Galvalume°,
clay or
3M"' Roof Tile Adhesive
Interdependent
99
99
1
stainless steel
concrete
RTA-1
Trim Lock
aluminum
clay or
3M'" Foam Roof Tile
Interdependent
P
90
84
concrete
Adhesive RTA-1
Trim Lock Plus
galvanized, Galvalume',
clay or
3M"' Foam Roof Tile
Interdependent
90
8
aluminum or stainless steel
concrete
Adhesive RTA-1
Trim Lock
galvanized, Galvalumel or
clay or
TILE BOND' Roof Tile
Interdependent
123
�
JJ
stainless steel
concrete
Adhesive
Trim Lock
aluminum
day or
TILE BOND- Roof Tile
Interdependent
79
731
concrete
Adhesive
Trim Lock Plus
galvanized, Galvalume',
clay or
TILE BOND- Roof Tile
Interdependent
79
I
731
aluminum or stainless steel
concrete
Adhesive
Trim Lock
galvanized, Galvalume° or
clay or
Touch'n Seal StormBond
Interdependent
146
139
stainless steel
concrete
Roof Tile Adhesive
Trim Lock
Aluminum
clay or
Touch'n Seal StormBond
Interdependent
58
54
concrete
Roof Tile Adhesive
Trim Lock Plus
galvanized, Galvalume',
day or
Touch 'n Seal StormBond
Interdependent
P
58
54
aluminum or stainless steel
concrete
Roof Tile Adhesive
Exterior Research and Design, U.C. Evaluation Report E10240.08I08-R4
Certificate of Authorization N9303 . FL5374-R4
Revision 4: 03/17/2015
Page 4 of 7
C W%( ERD
5.3 FOR NON-HVHZ JURISDICTIONS:
5.3.1 For Hip & Ridge Channel Metal or Trim Lock Channel Metal, refer to FRSA/TRI April 2012 (04-12). For Trim Lock Plus
Channel Metal, refer to the`installation instructions herein
5.3.2 For non-HVHZ, installations are limited to projects having hip and ridge design pressure requirements, determined in
accordance with Table 1A'of FRSA/TRI April 2012 (04-12), not greater than the following values. Refer to the tile
adhesive manufacturer's published installation instructions for adhesive paddy placement details.
s "INDEPENDENT" paddy placement means each individual tile is bonded to the Channel Metal in its own, single
foam paddy; tile head laps are not bonded. This method is limited to 2-part tile adhesives. This method is limited
to 2-part the adhesives. Allowable performance data below for "INDEPENDENT" paddy placement already has a 2
to 1 margin of safety applied to ultimate performance.
> "INTERDEPENDENT" paddy placement means each individual the is bonded to the Channel Metal in a foam paddy,
and a second foam paddy bonds the tile head lap, or two tiles are bonded to the Channel Metal using a single
foam paddy. Allowable performance data below for "INTERDEPENDENT" paddy placement already has a 4 to 1
margin of safety applied to ultimate performance.
TABLE 2A:-, PERFORMANCE LIMITATIo,Ns — NON-HVHZ, INDEPENDENT PADDY PLACEMENT
- (2TO 1 MARGIN OFSAFETYALREADYAPPGEO) -
Hip/Ridge Metal
Tile
Adhesive
Allowable Uplift
(Psf)
Design
Metal Type
Type
Placement
Hip & Ridge
galvanized
clay or
3M- 2-Component Foam Roof
Independent
169
Channel Metal
concrete
Tile Adhesive AH-160
Trim Lock
galvanized, Galvalume°, aluminum or
clay or
3M'" 2-Component Foam Roof
Independent
173
stainless steel
concrete
Tile Adhesive AH-160
Trim Lock Plus
galvanized, Galvalume,', aluminum or
clay or
3M'" 2-Component Foam Roof
Independent
178
stainless steel
concrete
Tile Adhesive AH-160
TABLE 2B: PERFORMANCE LIMITATIONS— NON-HVHZ; INTERDEPENDENT PADDY PLACEMENT
- (4TO1 MARGINOFSAFErYALREADYAPPLED) - -
Hip/Ridge Metal
Tile
Adhesive
Allowable Uplift
(Psfl
Design
Metal Type
Type
Placement
Trim Lack or Trim
galvanized, Galvalumem, aluminum or
clay or
3M— 2-Component Foam Roof
Interdependent
98
Lock Plus
stainless steel
concrete
Tile Adhesive AH-160
Trim Lock
galvanized, Galvalume" or stainless
clay or
3M- Foam Roof Tile Adhesive
Interdependent
110
steel
concrete
RTA-1
Trim Lock
aluminum
clay or
3M"' Foam Roof Tile Adhesive
Interdependent
93
concrete
RTA-1
Trim Lock Plus
galvanized, Galvalumel, aluminum or
clay or
3M'" Foam Roof Tile Adhesive
Interdependent
93
stainless steel
concrete
RTA-1
Trim Locic
galvanized, Galvalume° or stainless
clay or
TILE BOND— Roof Tile Adhesive
Interdependent
152
steel
concrete
Trim Lock
aluminum
day or
TILE BOND— Roof Tile Adhesive
Interdependent
82
concrete
Trim Lock Plus
galvanized, Galvalume°, aluminum or
clay or
TILE BOND" Roof Tile Adhesive
Interdependent
82
stainless steel
concrete
Trim Lock
galvanized, Galvalume° or stainless
clay or
Touch'n Seal Storm Bond Roof
Interdependent
148
steel
concrete
Tile Adhesive
Trim Lock
Aluminum
clay or
Touch 'n Seal StormBond Roof
Interdependent
61
concrete
Tile Adhesive
Trim Lock Plus
galvanized, Galvalume", aluminum or
clay or
Touch'n Seal Storm Bond Roof
Interdependent
61
stainless steel
concrete
Tile Adhesive
Exterior Research and Design, LLC. Evaluation Report E10240.08.08-R4
Cerri/icate o}Authorization #95o3 FL5374-R4
Revision 4: 03/17/2015
Page 5 of 7.
6. INSTALLATION:
6.1 The roof deck shall be minimum 15/32-inch plywood (non-HVHZ) or minimum 19/32-inch plywood (HVHZ) attached in
accordance with FBC Chapter 23 to the satisfaction of the AHJ.
6.2 Hip & Ridge Channel Metal and Trim Lock Channel Metal shall be installed using min. 11 ga. x 1%-inch long x 3/8-inch
head diameter galvanized annular ring shank nails spaced 6-inch o.c. along both deck -flanges. Fasteners shall be
positioned %-inch from the outside edge of each deck -flange, set in a bed plastic roof cement. For FBC HVHZ, refer to
FBC RAS 118, Drawing 13, Detail 3; RAS 119, Drawing 12, Detail 3; or RAS 120, Drawing 15, Detail 3.
6.3 Trim Lock Plus Channel Metal shall be installed atop the Approved roof underlayment in continuous 2-inch wide ribbons
of the adhesive centered beneath each 1.5-inch wide deck flange. Place the Trim Lock Plus Channel Metal into the wet
adhesive and allow it to set-up prior to installation of roof tiles.
6.3.1
6.3.2
View of Polyset AH160 Placementfor Trim Lock Plus Channel Metal. installation
It is critical that the bond between the Trim Lock Plus Channel Metal, the the adhesive and the underlayme�tt is not
disturbed prior to or during placement of the ridge tiles:
Approved underlayments are the codified 130/90' system or other FBC Approved roof underlayments listing approved
use of the subject tile adhesive.
Evaluation Report E10240.08.08-R4
Exterior Research and Design, LLC.
F6374-R4
Certificate of Authorization 49503 Revision 4. 03/17/2015
?age 6 of 7
ERD
6.4 Tile shall be installed atop the Channel Metal in accordance with the tile adhesive manufacturer's Approved, published
installation instructions, subject to the limitations outlined in Section 5 herein. The exposed edges shall be packed and
pointed with Approved mortar or weather blocking adhesive in accordance with FRSA/TRI April 2012 (04-12) or RAS
118, RAS 119, RAS 120 requirements.
Hip / Ridge Tile
Tile Adhesive
\ Trim Lock Plus
` Mortar or Weather Block
r Adhesive
_ =�_.! J
I Tile Adhesive
View of Trim Lock Plus Channel Metal Installation after Weather Blocked
6.4.1 Channel Metal shall be free of dust, debris, oils or other bond -breaking substance prior to placement of adhesive.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product.
8. MANUFACTURING PLANTS:
Contact the named QA entity for manufacturing facilities covered by F.A-C. Rule 61G20-3 QA requirements.
9. QUALITY ASSURANCE ENTITY:
Architectural Testing, Inc. — QUA1844; (717) 764-7700
- END OF EVALUATION REPORT -
Exterior Research and Design, LLC. Evaluation Report E10240.08.08-R4
CeMf$ateofAurhodzatian#9503 - FL5374-114
Revision 4: 03/17/2015
Page 7 of 7