Loading...
HomeMy WebLinkAboutEVALUATION REPORT - UNDERLAYMENTSSCANNED BY TRNIN ERD St Lucie County ATION REPORT RECEIVE® Boral Roofing NOV ®1 2�l 7575 Irvine Center Drive, Suite 100 Irvine, CA. 92618 ST. Lucie County, Permitting (602)269-2288 EXTERIOR RESEARCH a DESIGN, LLC. Certificate of Authorization #9503 353 CHRISTIAN STREET, UNIT #13 OXFORD, CT 06478 (203) 262-9245 Evaluation Report M35710.12.1U-119 FL14317-RB Date of issuance:12121/2010 Revision 9:10114/2017 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for corn liance with the 6tb Edition (2017) Florida Building Code sections noted herein. FILL COPY/foe"I-A-10-11-00/�� DESCRIPTION: Boral Roof Underlayments LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPUANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinityl ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 7. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCAANE1983 The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 10/14/2017. This does notserve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. Trinity ERD does not have, nor does it intend to acquire or will it acquire, a. financial interest in any company manufacturing or distributing products it evaluates. ny manufacturing or distributing products it evaluates. 2. Trinity ERD is not owned, operated or controlled by any compa 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. ial interest in any other entity involved in the approval process of the 4. Robert Nieminen, P.E. does not have, nor will acquire, a financ product. 5. This is a building code evaluation. Neither Trinity ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. R�N ERD ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Underlayment Compliance Statement: Boral Roof Underlayments, as marketed by Boral Roofing, have demonstrated compliance with the following sections of the 6th Edition (2017) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1504.3.1 Wind Uplift UL1897 2012 1507.1.1, T1507.1.1,1507.2.9.2 Physical Properties ASTM D1970 2015 1507.3.3 Physical Properties FRSA/TRI April 2012 (04-12) 2012 3. REFERENCES: Entity Examination Reference Date ERD (TST 6049) Physical Properties M36790.07.11 09/30/2011 ERD (TST 6049) Physical Properties B40380.08.12 08/28/2012 ERD (TST 6049) Tensile Adhesion / LTA C41420.09.12-2 09/12/2012 ERD (TST 6049) Adhesion 1341940.09.12 09/13/2012 ERD (TST 6049) Tensile Adhesion / LTA B47390.07.14-1 07/31/2014 ERD (TST 6049) Tensile Adhesion / LTA B47390.09.14 09/04/2014 PRI (TST 5878) ASTM D1970 NEI-031-02-02:REV 10/27/2010 PRI (TST 5878) ASTM D1970 NEI-029-02-01:REV 12/03/2010 PRI (TST 5878) Tensile Adhesion / LTA NEI-046-02-01REV 12/17/2010 PRI(TST5878) FRSA/TRI April 2012 NEI-076-02-01 02/14/2011 PRI (TST 5878) ASTM D1970 NEI-034-02-02 01/29/2013 PRI (TST 5878) Wind Uplift BORR-001-02-01 03/17/2015 PRI (TST 5878) Wind Uplift BORR-005-02-01 06/24/2015 UL, LLC. (QUA 9625) Quality Assurance Service Confirmation Exp. 08/21/2020 4. PRODUCT DESCRIPTION: 4.1 Self -Adhering Underlayments: 4.1.1 Boral TileSeal° 50HT is a nominal 50-mil thick, polyester -surfaced, self -adhering SBS modified bitumen roof underlayment; meets ASTM D1970. 4.1.2 Boral TileSeal° HT is a nominal 60-mil thick, polyester -surfaced, self -adhering SBS modified bitumen roof underlayment; meets ASTM D1970 and FRSA/TRI 04-12. 4.1.3 GatorSealO is a nominal 55-mil thick, granular -surfaced, fiberglass reinforced, self -adhering SBS modified bitumen roof underlayment; meets ASTM D1970. 4.1.4 Citadel° Plus is a nominal 48-mil thick, fabric -surfaced, fiberglass reinforced, self -adhering SBS modified bitumen roofing underlayment for use as a base -layer in two-ply underlayment systems; meets ASTM D1970. S. LIMITATIONS: 5.1 This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. ExteriorResearch and Design, I.I.C. Evaluation Report M35710.12.10-119 Certifimte of Authorization H9503 6'a EDITION (2017) FBC NON-HVHZ EVALUATION FL1�1317-RS Boral Roof Underlayments; (602) 269-2288 Revision 9:10/14/2017 Page 2 of 7 � ii'Ra F RD 5.3 Fire Classification is not part of this Laboratory Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. S.4 Boral Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 15.5 Allowable Roof Covers: Table 1 pertains to use of each listed underlayment by -itself beneath the stated roof covers. Refer to the installation instructions and Table 2 for two-ply underlayment options. TABLE 1: ROOF COVER OPTIONS Asphalt Adhesive -set Metal Wood Shakes Slate Underlayment Shingles Nail -On Tile Tile &Shingles I Yes Yes Boral TileSeal 50"r Yes No No Yes Yes Yes yes Yes Boil TileSeal"r Yes Yes (See 5.5.1) GatorSeal I Yes No • No No - Yes Yes 5.5.1 "Adhesive -set Tile" is limited to use of following Approved the adhesives / underlayment combinations. TABLE 1A: ALLOWABLE 1 iLE ADHESIVE �-U19DER1AYMENT COMBINATIONSl. Adhesive Florida Product Approval Underlayments DAP Foam Touch'n Seal Storm Roof Tile Adhesive I EL14506 BoralTileSeal"r Dow TILE BOND"' Roof Tile Adhesive FL22525 Boral TileSeal"r ICP Adhesives Polyset° AH-160 FL6332 floral TileSeal"r ICP Adhesives Polyset° RTA-1 FL6276 Boral Tile5eal"r ' 5.6 Allowable Substrates: 5.6.1 Direct -Bond to Deck: Citadel Plus, Baral TileSeal 50"r, Boral TileSeal"T or GatorSeal: > Plywood (unprimed or primed with ASTM D41 primer). Boral TileSeal"'. > OSB primed with ASTM D41 primer. Note: Refer to Section 5.6.4 for uplift limitations associated with direct -deck underlayment installations where the overlying roof cover is adhesive -set tile roofing 5.6.2 Bond to Base Laver Underlayment: Citadel Plus, Boral TileSeal 50"', Boral TileSeal"' or GatorSeal: > ASTM D226, Type II felt, Citadel Plus. For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum codified requirements. For installations under adhesive -set the systems, base layer shall be attached per minimum requirements of FRSA/TRI April 2012 (04-12), Appendix A, Table 1, or as listed in Section 5.6.4 herein, or as tested in accordance with FBC 1504.3.1. I Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance: Evaluation Report M35710.12.10-R9 Exterior Research and Design, U.C. FL14317-11II Certificate afAuthorization o9503 G' EDITION (2017) FBC NON-HVHZ EVALUATION Revision 9:10114/2017 Boral Roof Underlayments; (602) 269-2288 Page 3 of 7 Ski L ERD S.6.3 Bond to Other Substrate Tvoes: Citadel Plus, Boral TileSeal 50H , Boral TileSealHT or GatorSeal: i ASTM D41 primed metal (e.g., flashing metal, valley metal, etc). Boral TileSeal"T: b Huber Zip Deck (unprimed or primed with ASTM D41 primer); Dens Deck Prime. Note: For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum requirements of the prepared roof covering manufacturer's Product Approval. 5.6.4 Wind Resistance for Underlavment Systems in Adhesive -set Tile Applications: FRSA/TRI April 2022 (04-12) does not address wind uplift resistance of all underlayment systems beneath adhesive -set tile systems, where the underlayment forms part of the load -path. The following wind uplift limitations apply to underlayment systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used in adhesive -set the applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012 (04-12), Appendix A, Table 1A or FBC 1609 for determination of design wind loads 91 Maximum Design Pressure =-105 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Ply: (Optional) Citadel Plus, self -adhered Underlayment: Boral Ti(e5eal" ; self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x 1'4" ring shank nails through 32-ga.,1-5/8" diameter tin caps spaced 12-inch o.c. #2 Maximum Design Pressure = -120.0 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: ASTM D41 to the plywood deck Base Ply: Citadel Plus, self -adhered Cap Sheet: Boral T(IeSeal"T, self -adhered, and back -nailed within the selvedge -edge side laps using 12 ga. x 1%" ring shank nails through 32 ga.,1-5/8" diameter tin caps spaced 12-inch o.c. #3 Maximum Design Pressure = -202.5 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: ASTM D41 to the plywood deck Base Ply: None Cap Sheet: Boral TileSea] T' self -adhered, and back -nailed within the selvedge -edge side laps using 12 ga. x 1'/<" ring shank nails through 32 ga.,1-5/8" diameter tin caps spaced 12-inch o.c. #4 Maximum Design Pressure = -120.0 psf: Deck: Min. 2,500 psi structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: ASTM D41 to the concrete deck Base Ply: (Optional) Citadel Plus, self -adhered Cap Sheet: Boral T(IeSeal"TI self -adhered 5.6.4.1 Note: For adhesive -set file systems, if there is a base ply or mid -ply of Citadel Plus in the system, the project design pressure requirements may not exceed -120 psf. Exterior Research and Design, U.C. Evaluation Report M35710.12.10-R9 Certificate ofAutharization N9503 r," EDITION (20171 FBC NON-WRZ EVALUATION F1.14317-R8 Boral-Roof Underlayments, (602) 269-2288 Revision 9:10/14/2017 Page 4 of 7 z r r'1 i F� r4� • :. y �.I l� 5.7 Exposure Limitations: r prior to placement of final GatorSeal shall not be left exposed .or longer than 30-days after installation, roof cover. "r Boral TileSeal"' shall ` not be left exposed for longer than 180-days after Boral TileSeal 50and installation, prior to placement of final roof cove Citadel Plus, for use as a base -layer in a two-ply underlayment system, shall not be left exposed for longer than 180-days after installation, prior to placement of subsequent underlayment layer. 5.8imum roof slope shall ale Sllppase Limitations I FRSA/TRI April 2012 (04-1211: When loading roof tiles on the underlayment bedireex eededlby assemblies, using bbattens during loading of he roof be as follows. These slope limitations can only tiles. TABLE 1-."TILE SLIPPAGE UIVIlTAT10NS FOR DIREcr-DEC1(TILE_INSrALLATIONS Maximum Slope IProfile rofile Stagging Method Underlayment { Max.10-tile stack 6:12 Flat 6:12 BoralTileSeall" i Lugged Max.10-tile stack INSTALLATION: published installation 6.1 Boral Roof Underlayments shall be installed in accordance with Bore Roofing instructions subject to the Limitations set forth in Section 5 herein and the Sspecificsehe substrate. thoroughly 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep )(cable} to remove any dust and debris prior to application, and prime the substrate (if applicable). bient and surface temperatures are minimum 40"F and rising. 6.3 Install self -adhering underlayment when am 6.4 Citadel Plus: 6 4.1 Citadel Plus is limited to use as a base or mid -layer in multi -ply underlayment systems beneath Boral TileSeal 5e, Boral TileSeal HT or GatorSeal. 6 a.2 Slope limitations are those associated with the top -layer underlayment. 6.4.3 Direct�k= typically 10 to 12 ft. Align the membrane parallel to the roof Cut the membrane into manageable lengths, iyp edge, extending over by %-inch. Fold the membrane away from the edge onto itself. Remove the release sheet. Place the membrane with the exposed rubberized asphalt onto the deck, pressing firmly into place. Roll into place with a weighted roller. or Boral recommends fastening of the top nails of the sheet to.th deck slopes elofiroofing nails, nails &ti oagsfor 1-inch diameter plastic or steel cap P and minimum 4" slopes 7:12 and greater. Overlap successive courses minimum 2 inches (horizontal lap} end (vertical) laps. - underlayment layer atop Citadel Plus per `direct to-decl: instructions for Boral TileSeal 50 Install final�, Boral iileSeal"r' or GatorSeal. 6.4.4 To Baste t= Install base sheet of ASTM D226, Type 11 felt in accordance with Code requirements or in base ply o Citadel Plus in accordance with Boral Roofing published installation instructions and Section 6.4.3 and when used as part of a multi -ply system. published installation Install optional Citadel Plus as a mid -ply in accordance with Boral Roofing p instructions and Section 6.4.3. Install final underlayment layer atop Citadel Plus per `direct to -deck` instructions for Boral TileSeal 50" , Boral VeSeaF or GatorSeal. Evaluation Report M357 FO-12-9 17-R Exterior Research and Design, LLC. O' EDITION (2017) FDC NoN-HVHZ EVALUATION Revision 9:10114/203.7 Certificate ofAt4hor&0tfQn "9503 goral Roof Underlayments, (6(32) 269-2288 page 5 of 7 6.5 6.5.2 6,5.3 6.5.4 i6.6 6.6.1 6.6 2 6.6.3 r ERD Note: For adhesive -set the systems, if there is a base ply or mid -ply of Citadel Plus in the system, the project design�ese requirements may not exceed -120 psf. Boral T(IeSeat Shall beinstalled in compliance with the requi ements for ASTM D1970 underfayment in FBC Table 1507.1.1 for the type of prepared roof covering to be Do not use Boral TileSeal SORT on roof pitches less than 2:12. Non Tile A lications. Direct to Deck: membrane into manageable lengths, typically 10 Cut the me to:i2 ft. Alignthe membitself. Removeparallel to erase roof edge, extending over by'/ -inch. Fold the membrane away from t e ed ge sheet. Place the membrane with the exposed rubberized asphalt onto the deck, pressing firmly .into place. . deck with roofing nails, Roll into place with a weighted roller. the Boral recommends fastening of the black selvedge 24 in hgo c�for s lopes below 7:12 and 12 nails nch o.cn h slopes inch diameter plastic or steel cap nails spaarea, minimum 7:12 and greater. Overlap successiveapproved oufos edes hmastichor useof the bJoinedeand Folded Seam or Inverted Sheet Seal under end (vertical) laps using pprovedpublished installation instructions. Seam method detailed in Boral Roofing Non Tile Aance IVcations. to Base Sheet: Install ASTM D226, Type 11 felt in accordance ucthoCode requirements ns and Section 6.4, or install Citadel Plus in accordofin with Boral Roofing published installation instructions H� a 11 felt or Citadel Plus with Born Roofing Install Boral TileSeal 50 in accordance over ASTM D226, -Type published installation instructions and Section 6.5.3, except'end (vertical) laps, described below - where the self -adhering ton Apply SBS Mastic under all end (vertical)ulla laps all g theenterffasce into place with a weighted roller. underside is in contact with the fabric tip 6.6.4 GatorSeal: Shall be installed in compliance with the requirbe installed. ASTM p1970 underfayment in FBC Table 1507.1.1 for the type of prepared roof covering to Do not use GatorSeal on roof pitches less than 2:12. Non -Tile a IVicetions Directto Deck: Cut the membrane into manageable lengths, typically 10 to 12 ft. Align the membrane parallel to the roof ubberized asphalt onto the deck, pressing firmly into place. edge, extending over by %-inch. Fold the eedmbrane away from the edge onto itself. Remove the release sheet. Place the membrane with the expos s or 1 Roll into place with a weighted roller. Boral recommends fastening of the blackselvedge24gench o c. for slopes bge to the deck elow w 7.12 and 12 nails nch o.c. orgslopes inch diameter plastic or steel cap nails spaced 7:12 and greater. Overlap successive courses the width of the black -selvedge area, minimum 3-!nc . Seal end (vertical) laps using SBS Mastic under all side (vertical) laps Or any other laps where the self- lling the interface )ar or mineral top srface, adhering bituminous u in contact with the granu .the Inverted Sheet Seam detailed in Boral published into place with a weighted roller, or using installation instructions. Non -Tile Aonllcations. to Base Sheet: Install ASTM D226, Type II felt in accordance with Code requirements or install Citadel Plus in -accordance with Boral Roofing published installation instructions and Section 6.4_ Install GatorSeal over ASTM D226, Type 11 felt ar Citadel Plus in accordance with Boral Roofing published described otherbelow. installation instructions and Section 6.6.3 except oend (vertical) n rta laps where the self -adhering bituminous Apply SBS Mastic under all side (vertical) lapsy underside is in contact with the granular top surface, roiling the interface into place with a weighted roller. Exterior nesearcli and Design, LLC. Ceafficate of katharizatfon #9503 Evaluation Report N1357 C 317 RC ba' EDlT!OM1! I2017) FBC %1014-HVHZ EVALUATION Revision 9:10/1412027 Boral Roof Underlayments, (602) 269-2288 Page 6 of 7 ERD 6.7 Boral TileSeal "T: M p1970 underlayment !n FBC Table Shall be installed in compliance with the requirements for AST 6.7.1 prepared roof covering to be installed- 1507.1.1 for the type of prep "Ton roof pitches less than 2:12- 6 2 Do not use Boral TileSeai Cut the membrane Non -Tile A ►ications Direct to Deck: riot to installation. a extending 6.7.3 rime with ASTM D41 primer and al{ow to dry P arallel to the roof edg , For OSB substrate, P ically 10 to 12 ft. Align the membrane p place into manageable lengths, tYP from the edge onto itself. Re firmlthe nto place* hRoll into p a e /, Inch. Fold the membrane away pressing over by' = exposed rubberized asphalt onto the deck, p membrane with the nails, nails & tin tags or with a weighted roller. of the black selvedge edge to the deck with roofing Boral recommends fastening nails spaced 24-inch o.c. for slopes below 7:12 and -niinch 3-i for slopes inch diameter plastic or steel cap area, minimum 3-inch. rester. Overlap successive courses the width of the black -selvedge an 7:12 and g s using approved mastic, or use Joined and Folded Seam or Inverted Sheet Seal under end (vertical) lap ublished installation instructions• Seam method detailed in Boral Roofing P 6 7 4 Non Tile A lications to Base Sheet: install ASTM D226, TYp e I( felt in accordance with Code requirements or install Citadel Plus in accordanceRoofing with Boral Roofing published installation instructions and Sections described below - HT over ASTM D226, Type II felt or Citadel Plus in accordance with Boral install Boral Tileseal except end (vertical) lap , bituminous laps or any other laps where wihaa weighted roller. published installation instructions aVe� cad) n p.7.3, Apply SBS Mastic under all end ( surface, rolling the interface into place underside is in contact with the fabric top using the Tile A lications: TRl April 2017 (04-12) Installation Manual and Table 1 herein, 6.7.5 _- � Reference is made to FRSA/ guideline, instructions noted above as a g s stern, consisting of Base Sheet and self -adhering top For mechanicaliy fastened tale roofing over 2-ply Y TRl April 2012 (04-17%Table I. Base Sheet fastening shall be not less than FRSA/ sheet(s), stem, the For adhesive -set file applications, refer to Section 5.6.4 herein- l of Citadel Plus in the system, Note: For adhesive -set ti{e systems, if there is a base _ply or mid-p Y not exceed -120 psf- Boral project design pressure requirements may stem or counter Ilmitations_ Battens must be used for al! rile installations a op HT itches °f 2%: to less than 3.12. Lioral Rooling's Elevated Batten Sy Refer to Section S.8 for the staging TileSeal with roof p battens are required. ], BUILDING PERMIT REQUIREM official o r Authority Having As required by thJurisdiction in order to properly evaluate the installation of e Building this product. g MANUFACTURING PLANTS: Brentwood, NH 9. QUALITY ASSURANCE ENTITY_ a7ul.c+n? UL, LLC. — 4UA9625; (631) 546-2458; !<anchi.A .rawala,Doic_ aniat_-_ - END OF EVALUATION REPORT' 6EDIT ION(2017)FUcNON- VF!iEV►LUAT17(: Exterior Research alid 602 269-2298 6rtw-te ofAuthonzon°n 99503 Boral Roof Underlayrnents, l ! I Evaluation Report M35710.12.10-0 FL3.017-R8 Page 7 of 7