Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFILE C C. NOV 2 9 2018 FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Nartre: MOORE RESIDENCE Builder Name: GEM BUILDERS, INC. Streets 1 Permit Office: ST LUCIE COUNTY ''C/, A, City, State,�Zip: FORT PIERCE, FL, Permit Number: 'AA,,V�® Owner: I Jurisdiction: ST LUCIE COUNTY s 4i Design Location: FL, Fort Pierce County: SL Lucie (Florida Climate Zone 2) i 1. New.construction or existing New (From Plans) 9. Wall Types (2034.3 sgft.) Insulation Area 2. Single family or multiple family 9 y y Single-familya. Concrete Block - Ext Insul, Exterior b. Frame - Wood, Adjacent; R=5.4 1784.30 f? R=13.0 250.00 ft2 3. Number of units, if multiple family 1 c. NIA R= ft2 4. Number of Bedrooms 3 d. NIA R= ft2 5. Is this a worst case? No 10. Ceiling Types (2181.0 sgft.) a. Roof Deck (Unvented) Insulation Area R=20.0 2181.00 ft2 6. Conditioned floor area above grade (ft2) 2-181 b. N/A R= ft2 Conditioned floor area below grade (W) i 0 c. NIA 11. Ducts R= ft2 R 112 7. Windows (327.0 sgft.) Description Area a. Sup: Attic, Ret: Attic, AH: AHU CLST 6 150 a. U-Factor: Sgl, U=0.65 231.00 ft2 SHGC.:I SHGC=0;25 b. U-Factor. Sg1, U=0.65 96.00 ft2 12. Coding systems kBtuRrr Efficiency SHGC:I SHGC=0.30 a. Central Unit 35.0 SEER:16.00 c. U-Factor. N/A fe SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor. NIA fF a. Electric Strip Heat 27.0 COPA.00 SHGC:I Area Weighted Average Overhang Depth: 2.000 ft.Area Weighted Average SHGC: 0.265 14, Hot water systems a. Electric Cap: 40 gallons 8. Floor Types .(2181.0 sqft.) Insulation Area EF- 0.980 a. Slab -On -Grade Edge Insulation R=0.0 2181-00 ft2 b. Conservation features b. NIA R= ft2 None c. NIA R= ft2 16. Credits None 0.150 Total Proposed Modified Loads: 68.23 PASS Glass/FloJr Area: Total Baseline Loads: 73.42 I hereby cerItify that the plans and specifications covered by Review of the plans and ��EiE SrgT this calculation are in compliance with the Fiorida.Energy specifications covered by this Code. calculation indicates compliance 1 � �4� with the Florida Energy Code. PREP B Before'construction is completed inspected for ^- It' DAT this building will be compliance with Section 553.908 * a I cent, ify that this b ned, is in compliance Florida Statutes. COU wit to Iode. WB� OWN BUILDING OFFICIAL: DATE: r DATE: i - Compliagce,requires certi cation y the air handler unit manufacturer that the air handler enclosure qualifies as certified factorysealed in accordance with R403.3.2.1. - Compllance requires an Air Barrier and Insulation Inspection Checklist In -accordance with R402.4.1,1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.60 ACH50 (R402.4.1.2). i 10/11201812:43 PM EnergyGaugeO USA Section R405A.1 Compliant Software Page 1 of 6 PORM R4n5-9n17 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: MOORE RESIDENCE Bedrooms: 3 A'ddress Type: Street Address Building Tye: User Conditioned Area: 2181 Lot# Owner Name: Total Stories: 1 Block/Subdivision: #`of Units: 1 Worst Case: No PlatBook: Builder Name: GEM BUILDERS, INC. Rotate Angle: 0 Street: Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: SL Lucie Jurisdiction: ST LUCIE COUNTY Whole'House Fan: No City, State, Zip: FORT PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: i CLIMATE Design Temp Int Design Temp Heating Design Daily Temp V 'IDesign Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI i 39 90 70 75 299 62 Low .BLOCKS Number Name Area Volume. 1 Entire House 2181 22640 SPACES Number Name Area Volume _Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 ! M BATH 174 1740 No 0 0 1 Yes Yes Yes 2 M TOILET 20 200 No 0 1 Yes Yes Yes 3 II MWIC 1 42 420 No 0 1 Yes Yes Yes 4 M W IC 2 42 420 No 0 1 No Yes Yes 5 BATH 2 60 600 No 0 1 Yes Yes Yes 6 MASTER BEDROO 252 2772 No 0 1 1 Yes Yes Yes 7 CLST 3 24 240 No 0 1 Yes Yes Yes 8 BEDROOM 3 198 1980 No 0 1 1 Yes Yes Yes 9 CLST 2 16 160 No 0 1 No Yes Yes 10 BEDROOM 2 i84 1840 No 0 1 1 Yes Yes Yes 11 HALLWAY 87 870 No 0 1 No Yes Yes 12 FOYER 152 1520 No 0 1 Yes Yes Yes 13 HALF BATH 39 390 No 0 1 No Yes Yes 14 PANTRY 48 480 No 0 1 No Yes Yes 15 LAUNDRY 80 800 No 0 1 Yes Yes Yes 16 I KITCHEN 176 1760 Yes 0 1 Yes Yes Yes 17 I AHU CLST 9 go No 0 1 No Yes Yes 18 GREAT ROOM 578 6358 No 0 1 Yes Yes Yes I 1011/201812l43 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 2 of 6 �r%raRA onnC on47 IM01 IT QUIRRNIAPV M-IlFrIC11 IST RFP()RT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R: Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation M BATH 23 ft 0 174 ftz —._ 1 0 0 2 Slab -On -Grade Edge Insulation M TOILET 5 ft 0 20 ftz _ 1 0 0 3 Slab -On -Grade Edge Insulation M W IC 1 6 ft 0 42 ft' ____ 1 0 0 i Slab -On -Grade Edge Insulation M W IC 2 1 ft 0 42 ftz _-- 1 0 0 5 Slab -On -Grade Edge Insulation BATH.2 5 ft 0 60 ftZ ...- 1 0 0 6 Slab -On -Grade Edge Insulation MASTER BEDRO 14 ft 0 252 W 0 0 I Slab -On -Grade Edge insulation CLST 3 2 ft 0 24 f? __ 1 0 0 8 Slab -On -Grade Edge Insulation BEDROOM 3 28.6 ft 0 198 ftz 1 0 0 9 Slab -On -Grade Edge Insulation CLST 2 1 ft 0 16 ftz _-- 1 0 0 i 10Slab-On-Grade Edge Insulation BEDROOM 2 14 ft 0 184 ftz _--- 1 0 0 11Siab-On-Grade Edge Insulation HALLWAY 1 ft 0 87 ftz �. 1 0 0 12SIab=On Grade Edge l6sulation FOYER a ft 0 152 ft2 1 0 0 r 13SIab-On-Grade Edge Insulation I HALF BATH 1 ft 0 39 It, 1 0 0 14SIab-On-Grade Edge Insulation PANTRY 1 ft 0 48 ftz 1 0 0 15Siab-On-Grade Edge Insulation LAUNDRY oft 0 80 fe - 1 0 0 1 i lab -On -Grade Edge Insulation KITCHEN 8 ft 0 176 ftz 1 0 0 17Slab-On-Grade Edge Insulation AHU CLST 1 ft 0 9 ft2 1 0 0 16SIab-On-Grade Edge Insulation GREAT ROOM 50.3 ft 0 578 ft' ---- 1 0 D i ROOF Roof Gable Roof Solar . SA Emitt Emitt Deck Pitch #i Type Materials Area Area Color Absor. ;Tested Tested Insult (deg) 11 Hip - Metal 2439 ftz 0 ftz Light 0.6 No ' 0.9 No 26 26.6 ATTIC V #i Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 2181 ft' N N I 10/112018 12,43 PM EnergyGauge® USA Section R405A.1 Compliant Software Page 3 of 6 r c O C. O O O O O O O O O O O O Cl O O O m pp 8 O O pp ap pp pp 'O fC cD t0 cD w O w O c0 0w 0w f0 O c0 CD CO cD C f0 O c0 O c0 O IO O cD O O O O o O Cl O O O O O O O O O O O O D. O S O O G CSC7 O O U � 3t � � R. � � 's � � 3 � 3 3 S' 3: o 0 ~ Ft O O O O O O O O O O O O O O O O O O O N N m O O [) c` 11 LL LL co G, r O r O r Ci r O r 0 r C r O r O r O r C] r O r 0 r 0 r a r O r O r O r O C :c O CD O O to O' O O O O CD W 19-11 Cl) i O O O O O O O O .O LL N '-• .may. -- - - O -:O O0 O OO O O OO O O M O cl OO Cr: � ,%' MOON LO NWN OO Cl N M N7 W400Mm O 10 1- T 0 r o D M Qn N N N O'� C r «Y 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 CD n Y CD0 0 0 o t o 0 0 0 0 0 o a o r r r r o 0 r F o bi b$ SO oS w m ao m m m m m m m m m m m o 0 0 0. o 0 0 0-0 o r. o 0 0 0 o aD o m S op m m m m 'C7 M Or O cD lf1 r N N CO N V. W OD O N W. N M ..� t .J is 0 0 0 N 00 N N 0 N 0 cm 0 N 0. N o N 0 N 0 N 0 N 0 N 0 N 0 N 0 N o N Q } ,W N N 3 v v v, It a �t q v v, v, v, Nt C) LO o in .o to to un m m cn to to 0 0 o m � 0 o r M N W M M M M N O O .O O N W. M 2 N 2 Q Q' W J d 3: J N M O O O O O W R' O'. 0: Of O F O W Q m 2' Z7 2 U H a Q U = W F O O O O O} Z= Fa- F- H F Z} o, m 0 ¢ w J O J p LL Q H 1- m m 0 Q m cn " 4' w DC w a m w O LL M H U] W w W g m F v w w m" n g ,c ¢� m as w LU Y cc oWc .wry m m = 'C'I 5 3 ig N M _(N � N N ca ra N s a N C C N C C ran C N C CC W w, N C em C I N W W W W W W W W W W W liJ GJ L Y O Y O tY,,1 .7UG y_ Y O 4d O Y O '`9 O YU O _.[91 O Ad O O x O � cY� O �cL O Y O Y O Y GU� O 'pp -pp m m O m O m O m m m m m m m m m m m m' -m m m O O m o cC� 0 0 0 d 0 0 0 0 0 0 upp � d a 0 o 0 0 m 0 0 o ci 0 0 E C C C C C C C C C C C O O O p O O O O p coc .O C O O O O O.O 0 U U O U O U U U U U O U D U U U U U �U U U U LL LL N U O U G) O O Y) U a¢ O Q a O a O a U a U a U O a O a U a d a a¢¢ a a a m G`3 G`� `m t �di ' o d 4) $ .�3i- `0 4 0 0 o S `o i a o o 0 0 `o ov C C C C C C C C C C a �'1 4 1 da�rdid�iC g . I 'Sc t Tc . Tc iZ O O V > > > > > > > > > > > > > > > w w w w w w w w w w w w w w (1J tyf w -- -W—cn- -w- fA--W--U)---W- -Z—Z—W—-'Z—Z—?j—?�- -llj—N �T-Z--Z--- L C0 O 0 W c� .n 0 U c O G •a0 7 M m w m 0 N. O i r^rie.A oend, �n,� 1MDI.IT CI IInnnAMRV CN{=CKI'IST REPORT rvr`rvl r%.tVu7*Au 11, NAME V. ........ r�.�. --•--•--•-- ---- ---- WINDOWS Orientation shown is the entered, Proposed orientation. 7 wall Overhang Omt ID Frame _Panes. NFRC U-Factor SHGC . Imp_ Area Depth Separation IntShade Screening 1 I E 1 Metal Low-E Single Yes - 0.65 0.25 N 20.0 ft2 2ft Oln. 1 ft 4in None None 2 S 2 Metal Low-E Single Yes 0.66 0.25 N 10.0 ft- 2 ft 0, in 1 ft 4 in None None 3 S 6 Metal Low-E Single Yes 0.65 0.25 N 30.0 W 2 ft. din 1 ft 4 in None None 4 N 8 Metal Low=E Single Yes 0.65 0.25 N 30.0 ft,2 2 ft0; fn 1 ft4 in None None 5 NE 9 Metal Low-E Single Yes 0.65 0.25 N 10.0:ft2 2 1ft Oi in 1 ft 4 in None None 6 E 10 Metal Lov*E Single Yes 0.65 0.25 N 15:0 ft; 2 ft l) in 1, ft4, in None None 7 SE 11 Metal Low-E Single Yes '0.65 0.25 N 10.0 ft2 2'ft din 1 ft 41n None None B. N 12 Metal Low-E Single Yes 0.65 0.25 N 30.0 ft2 2 ft 0! in 1 ft 4 in None None 9 N 13 Metal . Low-E Single Yes 0.65 0.26 N 16.0 W 2 ft On 1 ft 4 in None None 10 S 16 Metal Low-E Single Yes 0:65 0.3 N 96.0 ft2 2 ft 0! in 1 ft 4 In None None 11 SW 17 Metal Low-E Single Yes 0.65 0.25 N 15.0 62 2 ft 01 in 1 ft 4 In None None 12 W 18 Metal Low:E Single Yes 0.65 0.25 N 30.0 ft2 2 ft 01n 1 ft 4 in None None 13 NW 19 Metal Low-E Single Yes 0.65 0.25 N 16.0 ftz 2 ft 01in ..1 ft 4 in None None GARAGE 1. ' #Floor ; ;Area Ceiling Area Exposed Wall Perimeter g Exposed (Nall insulation Avg. Wall Hel N 11 616ft2 616 ft2 25'ft' loft 13 INFILTRATION i # Scope' Method SLA CFMZO ELA EgLA ACH ACH 50 1 Wholehouse ProposedACH(50) .000462 2641.3 145.01 272.7 .3617 7 -HEATING ;SYSTEM #{ System Type Subtype Efficiency Capacity Block Ducts. 1 Electric Strip.Heatt None COP:1 27 kBtu/tir 1 sys#1 COOLING'SYSTEM #1 System Type Subtype.' ' Efficiency Capacity. � � Alr Flow SHR Block ,. Duds 1 I Central Unit/ Split SEER: 16 35 Wtulhr '1050 cfm 0.8 1 sys#1 HOT WATER SYSTEM- #1 System Type SubType Location EFL Cap Use SetPnt Conservation 1 Electric None Garage 9 0.98 40 el 9 60.9 al 9 120� ;deg None 10111201812I43 PM EnergyGauge® USA Section R405A.1 Compliant Software, Page of 6 none onnti_13n17 IIJOI IT CI IMMARY CNIF[_KI IRT RFPnRT SOLAR HOT WATER SYSTEM fSEC Collector Storage C`ert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS. / — Supply-- --- Return, - Air CFM 25. CFM25 HVAC # 1/ # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat; Cool 1 Attic 6 150 fN Attic. 15 ftz Default Leakage AHU CLST (Default) c(Defauit) c 1 1 TEMPERATURES Programabte Thermostat: N Ceiling Fans: Cooling,Jan. Heatin Feb H.Jaann [j Mar Apr May Jun [XJ Jul, Jun ) Jul JXj Au ) Aug X� Se ] Sep Oct Oct Nov No Dec DecVenting t Feb l�l Mar Apr ;May -Jun ]Jul E ]Aug, [� ];Sep Thermostat Schedule: HERS 2006 Reference Hairs. Schedule Type 1 2 3 4 5 6 7 8; 9 10 11 12 Cooling (WD)I AM 78 78 78 78 78 78 78 78 80, 80 80 '80 PM 80 80- 80' 80 78 78 78 78 78 78 78 78 Cooling.(WEH) AM 78 78 78 78, 78 78 78 78, 80 BO 80 80 I PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating (W D) I AM 65 65 65 65. 65 65 65 68 .66 68 68' 68 PM 6& 68 68 68 68 68 68 68 68 68 68 68 Heating.(WEH) AM 65 65 65 65. .65 65 65 66 68 68 68 68 PM 68: 68 - 68 68 68 68 . 68 68 68 '68 68 68 MASS Mass Type 'Area Thickness Furniture Fraction Space Defau t(8'Ibs1sq.ft. 0 ft2_ 0 ft 0:3` BEDROOM Defau t(&ibs/sq:ft W ft 0.3 WIC Defau t(8 ibstsq.ft ft= ft 0.3 HALL Default(8 Ibs/sq.ft fit= ft 0.3 BATH Defauit 8 Ibs/s .ft. ft . 0.3 STAIRS Nlame• Ri ting Compant: I 1011/201812'43.PM Signature- .. EnergyGaugeO USA Section R405AA Compliant Software Page 6 Of 6 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 93 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 2. Single-family or multiple -family 3. No. of units (if multiple -family) 4. Number of bedrooms i 5. Is'this a worst case? (yes/no) 6. Conditioned floor area (sq. ft.) 7. Windows, type and area a) U-factor:(weighted average) 6i) Solar Heat Gain Coefficient (SHGC) c� Area 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family b) Return ducts, R 6.0 c) AHU location Attic/Attic 3. 1 4. 3 13. Cooling system: Capacity 35.0 a) Split system - SEER 16.0 5. No b) Single package SEER c) Ground/water source SEERICOP 6. 2181 d) Room unit/PTAC EER e) Other 7a. 0.650 7b. 0.265 7c. 327.0 8. Skylights a) U-factor:(weighted average) 8a. NA F) Solar Heat Gain Coefficient (SHGC) 8b. NA 9. Floor type, insulation level: I ) Slab -on -grade (R-value) h) Wood, raised (R-value) c� Concrete, raised (R-value) 10. Wall type and insulation: A. Exterior: 1� Wood frame (Insulation R-value) 2. Masonry, (Insulation R=value) B. Adjacent: 1L Wood frame (Insulation R-value) 2�. Masonry (Insulation R-value) 11. Ceiling type and insulation level a) Under attic b) Single assembly c) Knee walls/skylight walls d) Radiant barrier installed 9a. 0.0 9b. 9c. 10A1. 10A2. 6.4 14. Heating system: Capacity 27.0 a) Split system heat pump HSPF b) Single package heat pump HSPF c) Electric resistance COP 1.0 d) Gas furnace, natural gas AFUE e) Gas furnace„ LPG AFUE f) Other 15. Water heating system a) Electric resistance EF 0.98 b) Gas fired, natural gas EF c) Gas fired, LPG EF d) Solar system with tank EF e) Dedicated heat pump with tank EF f) Heat recovery unit HeatRec% g) Other 110131. 13.0 110132. 16. HVAG credits claimed (Performance Method). a) Ceiling fans l la. 20.0 b) Cross ventilation No 11b. c) Whole house fan No 11c. d) Multizone.cooling credit l ld. No e) Multizone heating credit 0 Programmable thermostat No *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify "homeco plied 'th the Florida Building Code, Energy Conservation, through the above energy savingfe in (or exceeded) in this home before final inspection. Otherwise, a new EPL displayed n installed code compliant features. B alder Date: Addres Tme'w Home: fib L Zip: FORT PIERCE. FL l � tV�6- 10/1/201812.44:04 PM EnergyGaugeO USA 6.0.02 - FlaRes 17 FBC 6th Edition (2017) Compliant Software Page 1 of 1