HomeMy WebLinkAboutPRODUCT APPROVAL - SWINGING EXTERIOR DOORComments
Archived
13
Product Manufacturer
-W^^Fason:ibe`InternationalAddress/Phone/Email
Powis Roa
West Chicago, IL 60185
(800) 663-3667
sschreiber@masonite.com
Authorized Signature
Steve Schreiber
sschreiber@masonite.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category ExtDo9ls
Subcategory wingi"ng Ezterio D 'oon A§ssmrm'_embl es
Compliance Method Certification Mark or Listing
Certification Agency National Accreditation & Management Institute
Validated By National Accreditation & Management Institute
Referenced Standard and Year (of Standard) Standard Year
TAS 201 1994
TAS 202 1994
TAS 203 1994
Equivalence of Product Standards
Certified By
Product Approval Method Method 1 Option A
Date Submitted 11/06/2020
Date Validated 11/09/2020
Date Pending FBC Approval
Date Approved
11/17/2020
FL # I Model, Number or Name , I Description
22513.1 HPC Wood -edge Steel Side -Hinged 6-8" Glazed I/S or O/S Single or Double Door w/ or w/o
Door Unit I Sidelites
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +50/-50
Other: Evaluated for use in locations adhering to the Florida
Building Code, including the High Velocity Hurricane Zone,
and where pressure requirements do not exceed the design
pressures listed. 12'-0" x 6'-8" max nominal size. When
impact resistance is required, hurricane protective system is
required. Door top rails stamped "HPC". See DWG-MA-FL0212
for details.
Certification Agency Certificate
FL22513_R3_C_CAC _NI013747.01-R2.pdf
Quality Assurance Contract Expiration Date
06/30/2025
Installation Instructions
FL22513_R3_II_FL0212.Pdf
Verified By: National Accreditation & Management Institute
Created by Independent Third Party:
Evaluation Reports
FL22513_R3_AE_514008B.pdf
Created by Independent Third Party: Yes
22513.2 Wood -edge Steel Side -Hinged Door 8'-0" Opaque I/S or O/S Single Door Unit
Unit
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: +70/-70
Other: Evaluated for use in locations adhering to the Florida
Building Code, including the High Velocity Hurricane Zone,
and where pressure requirements do not exceed the design
pressures listed. 3'-0" x 8'-0" max nominal size. When impact
resistance is required, hurricane protective system not
required. See DWG-MA-FL0215 for details.
Certification Agency Certificate
FL22513_R3_C_CAC_NI013747.04-R1. pdf
Quality Assurance Contract Expiration Date
06/30/2025
Installation Instructions
FL22513_R3_II_FL0215.pdf
rified By: Verified National Accreditation & Management Institute
Created by Independent Third Party:
Evaluation Reports
FL22513_R3_AE_5140096.pdf
Created by Independent Third Party: Yes
22513.3 Wood -edge Steel Side -Hinged Door 8'-0" Opaque I/S Single or Double Door w/ or w/o Sidelites
Unit
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: +45/-50
Other: Evaluated for use in locations adhering to the Florida
Building Code, including the High Velocity Hurricane Zone,
and where pressure requirements do not exceed the design
pressures listed. 12'-0" x 8'-0" max nominal size. When
impact resistance is required, hurricane protective system not
required on opaque panels, but is required on glazed
sidelites. See DWG-MA-FL0215 for details.
Certification Agency Certificate
FL22513_R3_C_CAC_NI013747.04-Ri. pdf
Quality Assurance Contract Expiration Date
06/30/2025
Installation Instructions
FL22513_R3_II_FL0215_pdf
Verified By: National Accreditation & Management Institute
Created by Independent Third Party:
Evaluation Reports
FL22513_R3_AE_514007B.pdf
Created by Independent Third Party: Yes
22513.4 Wood -edge Steel Side -Hinged Door 8'-0" Opaque O/S Single or Double Door w/ or w/o Sidelites
Unit
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: +50/-45
Other: Evaluated for use in locations adhering to the Florida
Building Code, including the High Velocity Hurricane Zone,
and where pressure requirements do not exceed the design
pressures listed. 12'-0" x 8'-0" max nominal size. When
impact resistance is required, hurricane protective system not
required on opaque panels, but is required on glazed
sidelites. See DWG-MA-FL0215 for details.
Certification Agency Certificate
171-22513_113_C_CAC_NI013747.04-R1_pdf
Quality Assurance Contract Expiration Date
06/30/2025
Installation Instructions
FL22513_R3_II_FL0215.pdf
Verified By: National Accreditation & Management Institute
Created by Independent Third Party:
Evaluation Reports
FL22513_R3_AE_514007B.pdf
Created by Independent Third Party: Yes
22513.5 Wood -edge Steel Side -Hinged Door 8'-0" 3/4-Lite Glazed I/S or O/S Single or Double Door w/ or
Unit I w/o Sidelites
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +40/-40
Other: Evaluated for use in locations adhering to the Florida
Building Code, including the High Velocity Hurricane Zone,
and where pressure requirements do not exceed the design
pressures listed. 12'-0" x 8'-0" max nominal size. When
Certification Agency Certificate
FL22513_R3_C_CAC_NI013747.06-Rl.pdf
Quality Assurance Contract Expiration Date
06/30/2025
Installation Instructions
FL22513_R3_II_FLO 217,. pdf
Verified By: National Accreditation & Management Institute
Created by Independent Third Party:
Evaluation Reports
impact resistance is required, hurricane protective system is FL22513_R3_AE 514007B.pdf
required. See DWG-MA-FL0217 for details. Created by Independent Third Party: Yes
22513.6 1 Wood -edge Steel Side -Hinged Door 6'-8" Opaque I/S or O/S Single Door
I Unit
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: +70/-70
Other: Evaluated for use in locations adhering to the Florida
Building Code, Including the High Velocity Hurricane Zone,
and where pressure requirements do not exceed the design
pressures listed. 3'-0" x 6'-8" max nominal size. When Impact
resistance is required, hurricane protective system not
required. See DWG-MA-FL0211 for details.
Certification Agency Certificate
FL22513_R3_C_CAC_NI013747-R2.pdf
Quality Assurance Contract Expiration Date
06/30/2025
Installation Instructions
FL22513_R3_II_FL0211_.pdf
Verified By: National Accreditation & Management Institute
Created by Independent Third Party:
Evaluation Reports
FL22513_R3_AE_514010B.12f
Created by Independent Third Party: Yes
22513.7 Wood -edge Steel Side -Hinged Door 6'-8" Opaque I/S or O/S Single or Double Door w/ or w/o
Unit I Sidelites
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: +55/-55
Other: Evaluated for use in locations adhering to the Florida
Building Code, Including the High Velocity Hurricane Zone,
and where pressure requirements do not exceed the design
pressures listed. 12'-0" x 6'-8" max nominal size. When
impact resistance is required, hurricane protective system not
required on opaque panels, but is required on glazed
sidelites. See DWG-MA-FL0211 for details.
Certification Agency Certificate
FL22513_R3,_C_9jAC_NI013747-R2.pdf
Quality Assurance Contract Expiration Date
06/30/2025
Installation Instructions
FL22513_R3_II_FL0211,pdf
Verified By: National Accreditation & Management Institute
Created by Independent Third Party:
Evaluation Reports
FL22513_R3_AE_514008B.pdf
Created by Independent Third Party: Yes
22513.8 Wood -edge Steel Side -Hinged Door 6'-8" 3/4-Lite Glazed I/S or O/S Single or Double Door w/ or
Unit I w/o Sidelites
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +50/-50
Other: Evaluated for use in locations adhering to the Florida
Building Code, including the High Velocity Hurricane Zone,
and where pressure requirements do not exceed the design
pressures listed. 12'-0" x 6'-8" max nominal size. When
impact resistance is required, hurricane protective system is
required. See DWG-MA-FL0214 for details.
Certification Agency Certificate
FL22513_R3_C_CAC_NI013747.03-R2.Ddf
Quality Assurance Contract Expiration Date
06/30/2025
Installation Instructions
FL22513_R3_II_FL0214.pdf
Verified By: National Accreditation & Management Institute
Created by Independent Third Party:
Evaluation Reports
FL22513_R3_AE_514008B.pdf
Created by Independent Third Party: Yes
Back Ne-t
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
,The State of Florida is an AA/EEO employer. _Qpydght 2007-2013 State of Florida, :: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section
455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have
one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal
address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S.,
please click here
Product Approval Accepts:
® 'eClxs.
NOTICE OF PRODUCT CERTIFICATION
Company: Masonite International Corporation Certification No.:
1955 Powis Road Certification Date:
West -Chicago, IL 60185 Expiration Date:
Revision Date:
NI013747-R2
06/08/2017
-06/30/2025
07/27/2020
Product: Wood -Edge Steel Opaque Inswing or Outswing Door w/Non-Impact Rated Sidelites
(w/Wood Frame unless noted)
Specification: TAS 201/202/203-94
` Impact: Large Missile Impact Rated Non -Impact Glazing: Insulating Glass (Tempered)
The "Notice of Product Certification" is only valid if the NAMI Certification Label has been applied to the product as described within this document. The certification label represents product conformity to the
applicable specification and that all certification criteria has been satisfied. This product has been approved for listing within NAMI's Certified Product Listing at www.Namicertification.com. NAMI's
Certification Program is accredited by The American National Standards Institute (ANSI).
Inswing
Glazed
Structural
Water
Missile
Test Report Number
Configuration
or
or
Maximum
Design
Test
Impact
Drawing Number &
Outswing
Opaque
Size
Pressure
Pressure
Rated
Comments
X
I/S
Opaque
3'0" x 6'8"
+70/-70
0.0 psf
Yes
ATLNC 1001.01-13
Single
Maximum Panel Size: 3'0" x 6'8"
Anchor Details-DWG-MA-FL0211-17
X
O/S
Opaque
3'0" x 6'8"
+70/-70
3.0 psf
Yes
ATLNC-1001.01-13/W-1857
Single
4.5 psf'
Maximum Panel Size: 3'0" x 6'8"
7.50psf-.,
Anchor Details-DWG-MA-FL0211-17
XX
I/S
Opaque
6'0" x 6'8"
+55/-55
0 psf
Yes
NCTL-210-2930-1
Double
Maximum Panel Size: 3'0" x 6'8"
Anchor Details-DWG-MA-FL0211-17
XX
O/S
Opaque
6'0" x 6'8"
+55/-55
3.0 psf
Yes
NCTL-210-2930-1
Double
4.5 psf'
Maximum Panel Size: 3'0" x 6'8"
7.50psf'
Anchor Details-DWG-MA-FL0211-17
XO/OX
I/S
Opaque Door
6'0" x 6'8"
+551-55
0 psf
Door -Yes
NCTL-210-2930-1
Single w/Sidelite
Glazed Sidelite
Sidelite-No
Maximum Panel Size: 3'0" x 6'8" /Sidelite: 3'0" x 6'8"
Anchor Details-DWG-MA-FL0211-17
XO/OX
O/S
Opaque Door
6'0" x 6'8"
+551-55
3.0 psf
Door -Yes
NCTL-210-2930-1
Single w/Sidelite
Glazed Sidelite
4.5 psf'
Sidelite-No
Maximum Panel Size: 3'0" x 6'8" /Sidelite: 3'0" x 6'8"
7.50psf'
Anchor Details-DWG-MA-FL0211-17
OXO
I/S
Opaque Door
910" x 6'8"
+551-55
0 psf
Door -Yes
NCTL-210-2930-1
Single w/Sidelites
Glazed Sidelite
Sidelites-No
Maximum Panel Size: 3'0" x 6'8" /Sidelite: 3'0" x 6'8"
Anchor Details-DWG-MA-FL0211-17
OXO
O/S
Opaque Door
910" x 6'8"
+551-55
3.0 psf
Door -Yes
NCTL-210-2930-1
Single w/Sidelites
Glazed Sidelite
4.5 psf'
Sidelites-No
Maximum Panel Size: 3'0" x 6'8" /Sidelite: 3'0" x 6'8"
7.50psf'
Anchor Details-DWG-MA-FL0211-17
OXXO
I/S
Opaque Door
12'4" x 6'8"
+551-55
0 psf
Door -Yes
NCTL-210-'2930-1
Double w/Sidelites
Glazed Sidelite
Sidelites-No
Maximum Panel Size: 3'0" x 6'8" /Sidelite: 3'0" x 6'8"
Anchor Details-DWG-MA-FL0211-17
OXXO
O/S
Opaque Door
12'4" x 6'8"
+551-55
3.0 psf
Door -Yes
NCTL-210-2930-1
Double w/Sidelites
Glazed Sidelite
4.5 psf'
Sidelites-No
Maximum Panel Size: 3'0" x 6'8" /Sidelite: 3'0" x 6'8"
7.50psf'
Anchor Details-DWG-MA-FL0211-17
1-Denotes Bumper Outswing Threshold 2 -Denotes Z-Series Outswing Threshold 3-Hi-Dam Outswing Threshold 4-Pro T4 Threshold 5-HP Outswing Threshold
National Accreditation & Management Institute, Inc./4794 George Washington Memorial Highway/Hayes, VA 23072
Tel: (804) 684-5124/Fax: (804) 684-5122
NAMI AUTHORIZED SIGNATURE:'