Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
KSM REPORT
Headquarters 11345 U.S. Highway 1 " IV "CA I t ENGINEERING 7. Mailing PO Box 78-1377 � � �� AND TESTING Sebastian, FL. 32958 Sebastian, FL. 32978 Orlando 723 Progress Way Phone: 772-589-0712 C.A.# 5693 Sanford, FL. 32771 KSMengi nee ring. net June 21I , 2022 KSM JOB #: 2206068-1d/BS/KT CONTRACTOR: R & E Loader Service, Inc. JOB LOCATION: 5702 Hickory Drive SCANNED Ft. Pierce, Florida BY St Lucie County PERMIT #: 21�11-©486 " To Whom it may concern, I . Encloseed, please find the density test results performed on the Compacted Foundation Fill for the House Pad- Final Lift at the above referenced project. Should you have any questions, please feel free to contact our office. I Respectfully, ill I 1W "/" ♦♦\\\%C' This item has been elecwnkalHslgnetl Digitally signed No 69841 0—aone[heaI dd� 1. a• by Eric A McAr fight usmg a dlpUl slg�uNre. Date: Pointed roPks!, thh dmmmenta.e oPt Wo damdVg�ed and,, daM the aigPawtemuat 6e-dfed Pn any eIeNPPIc roPl 2022.06.22 Q '. .STATE OF •. . •' ; 10:43:22-04'00' , si ORIDP• •' (�� �� ONAL i J1 `� ��♦`♦ Eric A' McAra P E Office Manager I I . PE # 69841 06%21/22 Test report shall not be reproduced, except in full, without the written approval of KSM Engineering & Testing Geotechnical Engineering - Construction Materials Testing - Special Inspections - Civil and Structural Consulting Proudly Serving Florida since 1990 Certified Women Owned Business - WBE Headq `uarters - 11345 U.S. Highway 1 Sebastian, FL. 32958 Orlando 723 Progress Way Sanford', FL. 32771 DATE TESTED: PERMIT JOB 0 % t' ENGINEERING 17 AVZ AND TESTING SOIL COMPACTION REPORT ASTM D 1557 and ASTM D 6938 June 21, 2022 2j111-0486 )R: R & E Loader Service, Inc. ON: 5702 Hickory Drive Ft. Pierce, Florida Mailing PO Box 78-1377 Sebastian, FL. 32978 Phone: 772-589-0712 C.A.# 5693 KSMengineering.net KSM JOB #: 2206068-1d/BS/KT NUC # 456 Nuc Model: MC-1 Elite Nuc Serial # 31456 ITEM TESTED: Compacted Foundation Fill for the House Pad- Final Lift TEST LOCATION MOISTURE PERCENT DEPTH DENSITY PROCTOR VALUE OF SAMPLE % COMPACTION (P.C.F.) (P.C.F) 1 S.W. I 0" -12" 11.0 110.0 112.6 97.7% 2 N.W. 10.6 111.7 112.6 99.2% 3 Center 10.4 111.3 112.6 98.8% 4 N.E. 101 109.9 112.6 97.6% 5 S.E. 10.5 110.6 112.6 98.2% Soil Description: Brown Sind With Some Clay Proctor Optimum Moisture: Disclaimer: Contractor is responsible to maintain the tested area in the 10 % condition that KSM completed the indicated passed compaction test. KSM is Proctor Max. Dry Density: P.C.F. not responsible if the tested area has been altered from the approved 112.6 inspected condition. @ Test Locations the Density & Penetrometer readings indicate the Degree of Compaction Meets MinimuT Requirement For an Unformed -Foundation Test report shall not be reproduced, except in full, without the written approval of KSM Engineering & Testing Geotechnical Engineering - Construction Materials Testing - Special Inspections - Civil and Structural Consulting Proudly Serving Florida since 1990 Certified Women Owned Business - WBE i Headquarters IV OIL At ENGINEERING Sebas U.S. Highway 1 &Ji� AND TESTING Sebastian, FL. 32958 Orlando SOIL COMPACTION REPORT 723 Progress Way ASTM D 1557 Sanford, FL. 327.71 DATE T STED: June 21, 2022 PERMIT #: 2111-0486 CONTRACTOR: R & E Loader Service, Inc. JOB LOCATION: 5702 Hickory Drive Ft. Pierce, Florida Mailing PO Box 78-1377 Sebastian, FL. 32978 Phone: 772-589-0712 C.A.# 5693 KSMengineering.net KSM JOB # : 2206068-1d/BS/KT W 114.0 I I I E I 1 I I I I I I 113.0 +-.._...._.._._.._..._.._..�.._...�.._.._. G I I I I I I I H T 112.0 _.. I.._.._�._.._..I _.. I _.._�._.. _.. I.._.._. PI I I I I I I I I F 110.0_..L.._..1:._.._J._.._..L.._.. p I 1 I I I I I I R109.0 i -.. �.. _.I.—.._..i_.._.. �.._.._i._.._..� _.. �.._.._. Yi I I I I I 108.0 r.._...._.._._.._..�.._.._.._�._.._..�.._...._.._. I I I I I I I I 107.0 :1 ._.._..� _.. �.._.. 5 6 7 8 9. 10 11 12 13 Moisture - % of Dry Weight Soil Description: Brown Sand With Some Clay Proctor Optimum Moisture: 10% Procto' Max. Dry Density: P.C.F. 112.6 Test report shall not be reproduced, except in full, without the written approval of KSM Engineering & Testing Geotechnical Engineering- Construction Materials Testing -Special Inspections - Civil and Structural Consulting Proudly Serving Florida since 1990 Certified Women Owned Business - WBE