HomeMy WebLinkAboutKSM REPORTHeadquarters IV OIL t ENGINEERING Mailing 329 A% Q0 I%% AND TESTING PO Box 78-1377 81 Sebastian, FL! Sebastian, FL. 32978 Orlando SOIL COMPACTION REPORT Phone: 772-589-0712 723 Progress Way ASTM D 1557 and ASTM D 6938 C.A.# 5693 Sanford, FL. 32771 KSMengineering.net DATE TESTED: May 31, 2022 KSM JOB # : 2D 981= pd/,BS/KT PERMIT- • 2%2Q3 08�12 CONTRACTOR: Jim Custom Pools NUC # 456 Nuc Model: MC-1 Elite JOB LOCATION: 5458 Silver Oak Drive Nuc Serial #: 31456 Fort Pierce, Florida ITEM TESTED Pool Backfill Compaction TEST LOCATION PEN Moisture DRY MAX. DRY PERCENT OF SAMPLE DEPTH READ % DENSITY PROCTOR VALUE COMPACTION 1 West 0'-1' 40 D 8.2 104.5 108.4 96.4% 2 1'-2' 40 D - - 95.0%+ 3 2'-3' 40 D - - 95.0%+ 4 3'-4' 40 D - - 95.0%+ 5 North 0'-1' 40 D 8.6 103.8 108.4 95.8% 6 V-2' 40 D - - it 95.0% + 7 2'-3' 40 D - - 95.0% + 8 3'-4' 40 D - - 95.0% + 9 East 0'-1' 40 D 8 105.1 108.4 97.0% 10 V-2' 40 D - - t' 95.0% + 11 2'-3' 40 D - - tt 95.0% + 12 3'-4' 40 D - -It95.0% + Soil Description: Gray Sande REVIEWED FOR CODE COMPLIANCE E Proctor Optimum Mgi4tuWCIE COUNTY BOCC G 10.0% T T Proctor Max. Dry Density: P.C.F. 108.4 P @ Test Locations the Density & Penetrometer reading indicate the `\\ttt I t tjit/,/ D Degree of Compaction Meets `�� EKE ��i Minimum, Requirement ��� J�!.......... ��i F For Unplumbed Backfill �� • ' �,\�ENsF .•� ��� Respectfully Submitted: No.68366 D Digital * _ R signEO.t)� * �; y This Item has been elecvonlolly signed and .Julie ill:. STATE OF •' �.4 Moisture - % of Dry Weight sealed Walla Keller, P.E. fl. Uc 68366 on ` the date stated dlrecdy W the right usinga �� �► •.• R p •.•' # Disclaimer: Contractor is responsible to maintain the pool backfill digital signature. 4 •, 0111 S "I dnted metes olth[s dowmentarerot Date: i •••• ��� in the condition that KSM completed the indicated passed sigmW argneaanaseaeaandma �iONA` �?�` compaction test. KSM is not responsible if the oolbackfill has signature mastbeveaNed on amy elecvontc 2022A5.3t; ,, �\ r� p p p �ples r ► i l ► .. 16:11:40 been altered from the approved inspected condition. -04'00' Julie E. Keller, P.E. President PE # 68366 5/31/2022 Email to: jmcustompoolsinc@gmail.com Test report shall not be reproduced, except in full, without the written approval of KSM Engineering & Testing Geotechnical Engineering - Construction Materials Testing - Special Inspections - Civil and Structural Consulting Proudly Serving Florida since 1990 Certified Women Owned Business - WBE'