Loading...
HomeMy WebLinkAboutREVISION - BUILDING PERMIT - 3-26-19OFFICE USE ONLY: ( „ DATE FILED: REVISION FEE: PERMIT # l t l 1/- RECEIPT # 1,"/ RECEiV�b PLANNING & DEVELOPMENT SEIRVW. BUILDING & CODE REGULATION D Agj"' ,,i� '� ` `'�r !MAR 2 6 201O �_� 2300 VIRGINIA AVENUE FORT PIERCE FL 34982.56j ' '+ Permitting CJ�PdptFfl@rif � TSt. Tucle Comity (772) 462-1553aUlm APPLICATION FOR BUILDING PERMITR1fir�(, PROJECT INFORMATION LOCATION/SITE 'ADDRESS- y SC�y�ED 4-t Sr , e DETAILED DESCRIPTION OF PROJECT REVISIONS: O Lkj GY nerd:. V CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: CCr C 6 ?.3 % 5 io ST. LUCIE CO CERT. #: BUSINESS NAME:�Y- QUALIFIERS NAME: ADDRESS: 4-50o 6�01 pi CITY: e o STATE: �'[ !. , ZIP: 3�k'Sj L ' PHONE (DAYTIME): 3 FAX: OWNER/BUILDER INFORMATION: NAME: ADDRESS: CITY: PHONE (DAYTIME: STATE: ZIP: FAX: ARCHITECT/ENGINEER INFORMATION: NAME: � Sa k C . 4-f ADDRESS: S' SS A, G,.. �,i*er L�.-c%rb, 5ZAG CITY: 1 e- i.i STATE: L� PHONE (DAYTIME): 7 %Z - 3 q 9 9,6 FAX: SECCC: 9123109 Revised 06130117 ZIP: 32-5,6 Q ;v T.E. S C H LITT EN G IN EERI N G March 25, 2019 Mr.1 Gary Stepalavich, Building Official St. Lucie County Building Department 2300 Virginia Ave Ft. Pierce, FL 34982 Subject: Project Scope — Trejo-Garcia Residence Building Permit Number 1a8ria 022 2801 N. A1A, Unit B Ft. Pierce, Florida 34949 Engineer's Project Number: 18FO40 Dear Mr. Stepalavich: RECEIVED MAR 2 6 jolt Permitting Bearme�Y nt St. LuctE Cow Per contractor/owner request, the following revision has been reviewed and approved by this office. The existing roof trusses do not bear on the affected wall and reducing the loads to the bealm allowed our office to revise the size and connector accordingly. The! existing beam under the second floor exterior wall at the rear (east) of the building is damaged. • The beam shall be replaced with a two ply 1.75"x14" LVL. The beam plys shall be connected With three rows of 16d's at 12" on center maximum. The bucket connectors on the ends will The HUC410 into the existing CMU. The connectors for the bucket shall be (10) 10d's in the beam and (18) %" x 2.75" Titen 2's into the wall. The',windows and mullion shall meet the following design pressures (allowable). • 41 pounds per square foot and -45 pounds per square foot All other details shall follow the permitted set of plans. Should you have any questions regarding the above subject, please call. Very truly yours, Terence Schlitt, P.E. FL P.E. # 81238 CA #32295 i cc: Mr. Kurutz, ROVB, Inc. NCE SC \\����`C E ift A _ No. 81238 March 25, 2019 STATE OF , ' Al 101VAL E�G��\\ /llllll 15551Indian River Blvd. Suite B-145 --" T!7721360.4998 Vero Beach, FL 32960 StructuralFL@gmail.com