HomeMy WebLinkAboutEVALUATION REPORT - METAL ROOFINGL-7 • EVALUATION REPORT OF METAL SALES MANUFACTURING CORPORATION '26 GA. 5V-CRIMP PANEL' SCANNED BY FLORIDA BUILDING CODE 6TH EDITION (2017) St Lucie County FLORIDA PRODUCT APPROVAL FL 14645.4-R3 ROOFING METAL ROOFING Prepared For: Metal Sales Manufacturing Corporation 545 South 3rd Street, Suite 200 Louisville, KY 40202 Telephone: (502) 855-4300 ST. LUCIE CO B DI P COUNTY NG VI ION Fax: (502) 855-4290 REVIEWED FOR MP REVIEWED BY DATE PLANS AND PER MUST BE KEPT ON JOB SITE OR NO INSPECTIONS) WILL BE MADE Prepared By: Bala Sockalingam, Ph.D., P.E. Florida Professional Engineer #62240 1216 N Lansing Ave., Suite C Tulsa, OK 74106 Telephone: (918) 492-5992 FAX: (918) 493-3568 This report consists of Evaluation Report (3 Pages including cover) t%1111es0,`,1 Installation Details (1 Page) 0♦�%`'SpC!<AL/ `'�d, Load Span Table (1 Page) o.`° �,P.•;� E N S'��'yp'fa Report No. C2182-4 Date: 9.9.17 FILE COPY No 62240 b � w STATE OF ' "J 4 ss0T• A' Q�.'•��a ��i FS; • OR • • �?� e♦0 . e ,::k.-�. zQ(-7 • • Manufacturer: Product Name: I Panel Description: Materials: Deck Description: i Deck Attachment: (Minimum) Underlayment: Slope: i Design Uplift Pressure: (Factor of Safety = 2) Fastener Pattern: Type: I At panel ends At intermediate i Test Standards: Test Equivalency: Code Compliance: Metal Sales Manufacturing Corporation 5V-Crimp 24" wide coverage with (5)1/2" high ribs FL 14645.4-R3 C2182-4 9.9.17 Page 2 of 3 Min. 26 ga., 50 ksi steel. Galvanized coated steel (ASTM A653) or Galvalume coated steel (ASTM A792) or painted steel (ASTM A755). Min. 7/16" thick OSB or min. 15/32" thick plywood or min. V thick wood plank (min SG of 0.42) for new and existing constructions. Designed by others and installed as per FBC 2017. 8d x 2.5" long ring shank nails or #8 x 2" long wood screws @ 6" o.c. in the plywood field and edges. Designed as per FBC 2017. Minimum underlayment as per FBC 2017 Section 1507.4.5.1. 1/2:12 or greater in accordance with FBC 2017 Section 1507.4.2. Requires applied lap sealant for roof slopes less than 3:12. 30.0 psf @ fastener spacing of 36" o.c. 172.5 psf @ fastener spacing of 6" o.c. #9-16 or #10-14 hex head wood screws with sealed washer. Fastener shall be of sufficient length to penetrate through the deck a minimum of 3/8" and installed as per Metal Sales current installation procedure. @ 6" o.c. across panel width @ 12" o.c. across panel width Roof assembly tested in accordance with UL580-06 `Uplift Resistance of Roof Assemblies' & UL1897-04 `Uplift Tests for Roof Covering Systems'. The test procedures in UL 1897-04 comply with test procedures prescribed in UL 1897-12. The product described herein has demonstrated compliance with FBC 2017 Section 1507.4. Product Limitations: Design wind loads shall be determined for each project in accordance with FBC 2017 Section 1609 or ASCE 7-10 using allowable stress design. The maximum fastener spacing listed herein shall not be exceeded. The design pressure for reduced fastener spacing may be M FL 14645.4-R3 C2182-4 9.9.17 Page 3 of 3 computed using rational analysis prepared by a Florida Professional Engineer or based on Metal Sales load span table. This evaluation report is not applicable in High Velocity Hurricane Zone. Fire classification is not within scope of this Evaluation Report. Refer to FBC 2017 Section 1505 and current approved roofing materials directory or ASTM E108/UL790 report from an accredited laboratory for fire ratings of this product. Supporting Documents: UL580 & 1897 Test Reports PRI Construction Materials Technologies MSMC-017-02-01, Reporting Date 9/20/13 SV-CRIMP _ PANEL OVERLAP _ _ _ as ' & _3 21 5_ SEE DETAIL 2 SEE DETAIL 1 FASTENER AT PANEL FLAT REQUIRED FOR PANEL 3 ENDS ONLY. I I MINIMUM ATTACHMENT: PANEL FASTENER PER UPLIFT LOAD TABLE UNDERIAYMENT SHALL BE INSTALLED 8d x 2.5" LONG RING SHANK NAIL OR #8 x 2" LONG WOOD SCREWS - AS PER MANUFACTURER'S INSTALLATION GUIDELINES SPACED 06" O.C. IN THE FIELD $ & AT EDGES MIN. 2X- WOOD RAFTER/JOIST/ TRUSS AT MAX. 24" O.C. o TYPICAL PANEL INSTALLATION X-SECTION S " N O �8 y�00 6 OR WITHSELFSEALING WASHER A10-14 T MAXIMUM SPACING OF 36" O.C. 04 J 1 o PLO 5V-CRIMP MIN 26 GA. 8-33 d n GENERAL NOTES: c 1. ARCHITECTURAL ROOF PANEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE a UNDERLAYMENT FLORIDA BUILDING CODE (FBC). g DETAIL 1 OSB 7/16" THICK (MIN.) OR PLYWOOD 15/32" THICK (MIN.) 2. ROOF PANELS SHALL BE MIN. 26 GA. (t = 0.0191. EFFECTIVE COVERING WIDTH OF PANEL = 24". � IF 3. THE ROOF PANELS SHALL BE INSTALLED OVER SHEATHING & STRUCTURE AS SPECIFIED ON THIS DRAWING. #9-16 OR #10-14 WOODSCREWS 4. REQUIRED DESIGN WIND LOADS SHALL BE DETERMINED FOR EACH PROJECT. THIS PANEL SYSTEM MAY NOT BE INSTALLED WHEN THE REQUIRED DESIGN WIND LOADS WITH SELF SEALING WASHER AT MAXIMUM SPACING OF 36" O.C. ARE GREATER THAN THE DESIGN UPLIFT PRESSURES SPECIFIED ON THIS DRAWING. 5. ALL FASTENERS MUST BE IN ACCORDANCE WITH THIS DRAWING & THE FLORIDA 'm BUILDING CODE. IF A DIFFERENCE OCCURS BETWEEN THE MINIMUM REQUIREMENTS OF THIS DRAWING & THE CODE, THE CODE SHALL CONTROL 5V-CRIMP 6. RAFTERS/JOISTS/TRUSSES MUST BE DESIGNED TO WITHSTAND WIND LOADS AS MIN 26 GA. REQUIRED FOR EACH APPLICATION AND ARE THE RESPONSIBILITY OF OTHERS. UNDERLAYMENT 2182-4 DETAIL 2 OSS 7/16" THICK (MIN.) OR PLYWOOD 15/32' THICK (MIN.) ylmT 1 NO, 1 � a El METAL SALES MANUFACTURING CORPORATION 5V-Crimp uplift Loads (Min. 26 ga.) Description Fastener Spacing along panel length (in) Allowable Uplift Load (psfl Coverage width- 24" 6 172.5 9 120.0 1 ? 90.0 Panel Fasteners 15 72.0 #9-16 or # 10-14 hex head 18 60.0 wood screws with sealed 21 51.4 washer 24 45.0 7 40.0 30 36.0 33) 32.7 36 30.0 Note l ' I� 1. The bold numbers indicate design loads calculated from test data with safety factor of 2. 2. P I anels must be installed as per Evaluation Report FL 14645.4 and Metal Sales current installation procedure. 3. Three or more spans condition, i 1 1216 N Lansing Ave.. Suite C Tulsa, Ok 74106 918 492 5992 I I tttttetarrra `°o3°°P g O C K'4� No 62240 STATE OF •44/ a e 2G1`7 Bala Sockalingam, Ph.D., P.E. FL 62240