HomeMy WebLinkAboutLETTER ABOUT RE-ROOFINGRe:
r 29, 2018
Frechette Re -Roof
1078 Nettles Blvd.
Jensen Beach, FL
PAUL WELCH INC.
Mechanical Electrical Civil Engineering
1984 S.W. Biltmore St. Suite#114
Port Saint Lucie, FL 34984
Phone (772) 785 - 9888
E-mail pwelchinc@aol.com
RECEIVED
NOV 0 2 2019
ST. Lucie county, p�iltting
1
new Metal Roof (Extreme Metal Fabricators, LLC "5-V Crimp" FL #17022.1) at above
iced address over new underlayment, and existing plywood sheathing.
2017
E7-10'J
F.1=1i
1078'.
1 VA1A:
G FUGHT = 10'-0"
ROOF HIEGHT = <20'
ANGLE = 2:12
? = PITCHED GABLE
'TMENT FACTOR = 1.00
>TANCE FACTOR = 1.00
VELOCITY V ult = 165MPH
VELOCITY V asd = 128 MPH
;URE = D
)SURE CLASS = ENCLOSED BUILDING
NAL PRESSURE COEFFICIENT = -0.18
E 1 (Field) = -40.3
E 2 (Perimeter/ Ridge) = -68.0
E 3 (Corners) = -99.8
Blvd. Jensen Beach, FL
Paul Welch Inc.
Paul Welch P.E. Reg. No..29945
October 29, 2018
1 of 3
Meal roofing to be attached with corrosion resistant Hex -Head wood screws #10 z 1 %2"
minimum with weather sealing washers (minimum 3/16" penetration through deck).' Fasteners
shall be placed through the panel ribs at 12" on center across panel width and spacing along the
ribs �as follows:
not
the
and
laps
in
All
1 (Field): FASTENER SPACING = 16" O.C.
2 (Perimeter/ Ridge): FASTENER SPACING = 16" O.C.
3 (Comers): FASTENER SPACING = 8" O.C.
PROVIDE LAP SEALANT FOR ALL ROOF PANEL LAPS FOR ROOF
S UNDER 3 VERT.:12 HORZ.
uplift Pressure for attachment as per above:
t Design Pressure: Zones 1 & 2:-93.5PSF / Zone 3:-101PSF
ire O.K.
dayment shall be Tri-Built Roofing Products FL# 16048.1 "Tri-Built S/A HT TU".
priming is optional, TRI-BUILT recommends priming the deck if the final roof cover is
ated for installation within 24 hours.
i sheet parallel to the roof edge. Roll out approximately 10 ft of membrane and peel back
st 3 ft of release film.
re the exposed part to the substrate and unroll the remaining membrane as far as possible.
the entire length of membrane is in place, peel -off the release film diagonally while
ig the membrane tight. Firmly roll the membrane into place to achieve a bond. Horizontal
o should be minimum 3-inches, configured to shed water. Vertical seams should be 6inches
aggered not less than 2-ft from vertical seams in the course below. All over -granule end -
hall be sealed using either heat -welding or hot air welding techniques. For Valleys and
s: Cut underlayment into 4 to 6 foot lengths. Peel the release paper and center sheet over
or ridge. Drape and press sheet into place, working from the center of the valley or ridge
h direction. For valleys, apply the sheet starting at the lowest point and work upward.
all plywood sheathing (15/32" thick minimum) with 8D ring -shank nails at 4" O.C.
,r and 6" O.C. field for all zones.
to be in compliance with product approval (FL # 17022.1), (FL# 16048.1),
urer's specifications, and the Florida Building Code 2017.
Paul Welch Inc.
Paul Welch P.E. Reg. No. 29945
October 29, 2018
1078
Blvd. Jensen Beach, FL
2 of 3
ft
ft
GA %6
'A+
GA 6
Ad au��q is
A. A
ROOF ZONE PLAN
A=3'
ZONE DESIGNATION (TYPICAL)
NOTE: PROVIDE LAP SEALANT FOR ALL ROOF PANEL LAPS FOR ROOF
SLOPES UNDER 3 VERT.:12 HORZ.
Paul Welch Inc.
Paul Welch P.E. Reg. No. 29945
October 29, 2018
1078 Nettles Blvd. Jensen Beach, FL 3 of 3
rA
�I �UCI@
Search Criteria C� . tj/
Refine Search
Code Version
2017 ,
FL#
17022.1
Application Type
ALL
Product Manufacturer
ALL
Category
ALL
Subcategory
ALL
Application Status
ALL
Compliance Method
ALL
Quality Assurance Entity
ALL
Quality Assurance Entity Contract Expired
ALL
Product Model, Number or.Name
ALL
Product Description
ALL
Approved for use in HVHZ
ALL
Approved for use outside HVHZ
ALL
Impact Resistant
ALL
Design Pressure
ALL
Other
ALL
FL## -
Tvne
Manufacturer
Validated By
Status
FL17022-
Revision
Extreme Metal Fabricators, IlC
FL#: FL17022.1
Zachary R.
Priest, P.E.
Approved
R7
History
Model: 1 - "'SV Crimp" (116)
(813)-480-3421
Description: 26 Gauge steel, 3/8" rib height, 24" wide lapped roof panel
mechanically attached to 15/32" plywood or Wood Deck with fasteners
Category: Roofing
Subcategory: Metal Roofing
Contact Us :: 2601 Blair Stone Road. Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an A-VEEO employer. Coovriaht 2007-2613 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. 9 you have any questions, please contact 850.487.1395. "Pursuant to Section 455.275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails
provided may be used for official communication with the licensee However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please dick here .
Product Approval Act:
Credit Cardl
Safe
Limitations:
1. Underlaym
2.. Minimum s
3. Products a
4. Engineerin
5. Fire classif
6. Support fra
Structural t
7. This report
FL17022.1 5Vftp (26GA Steel), 24" Wide Roof I=anel - Details
nt to be compliance with current Florida Building Code (FBC)2017 6th ed..
pe to be compliant with Florida Building Code 2017 6th ed., and per with Manufacturer's installation reference.
compliant for State of Florida product approval per Rule 61G20-3. Compliance Method: 1-D
analysis for "project specific approval by local authorities w/jurisdiction is allowed by other registered engineers.
ation is not part of this acceptance. Shear diaphragm values are outside this report.
iing in compliance w/FBC 2017 6th ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for
,ading.
oes not imply warranty; installation, recommended product use outside of this report.
Fasteners -
#9 x 1-1/Y Min. or
#10 x 1-10 Min. per Table A' for Row 5-V Crimp Roof Panel
Spacing and Design Pressures
Hex Washer Head Wood Screws
Deck:
-15W or greater Plywood, or
- Wood plank
24-
12"
3/8"
aP1lok AL STPU710NS
Panel Profile
Nominal 12" Nominal 12"
O.G. O.C.
r Fasten r
f9 x 1-1/2" Min. or #10 x 1-1/2" Min. per
Table "A" Hex Washer Head Screw
Spaced 12" o.c. across the Panel Width
Panel Refer to Table "A" for Spacing Along Panel
Overlap Length
l
Deck-15/32" or greater
Plywood, or
-Wood plank
dols
Compliant with Florida Building Code 2017 (6th ed.)
with Florida Product Approval Rule # 61G20-3
Keystone Certifications
5 V Crimp 26GA Steel Roof Panel FBC Sec.1507.4.2
Yield strength: 50 ksi min.; Attached to min.15/32" plywood or. Wood
Deck w/ min. 0.42 specific gravity with screws. 24" Coverage
Rib Height 3/8"
i Resistant Compliant: FBC Sec.1507.4.3
Fastener 1(Method 1 Attachment): #9 x 1-1/2" Hex -Washer Head wood screw* to penetrate
3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length to meet
-- -- -- - -I . -
Fastene 2 (Method 2,3, & 4 Attachment): #10 x 1-1/2" Hex -Washer Head wood screw* to
penetrate 3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length
to meet requirements)
Underlayment: To be compliant with FBC Sec. Chart 1507.1.1
Slope: Shall be in compliance with FBC Sec.1507.
See Fastener attachment specifications ahnvp
Install Details: Table A Allowable Loads
METHOD 1
METHOD 2
METHOD 3
METHOD 4
DESIGN PRESSURE*
-86 PSF
-93.5 PSF
.-101 PSF
-228 PSF
ROW SPACING
FASTENER, SPAGNG .(ALONG Panel width)
16" O.C.
12" o.c.
16" o.c.
12" o.c.
8" O.C.
12" ox.
6" ox.
12" ox.
FASTENER; SIZE
i
#9
#10
#10
#10
Keterence Data: ARCHITECTURAL TESTING, INC. TST ID#:1527
UL.580-06 1& 1897-041 Test Report E(6893.01-450-18 05/02/14
Test Report F3366.01-450-18 - 12/18/15
TAS 125-03 Test Report D05893.02-450-18 07/22/14
*EQUZVA4E Cr--UL 1897-04 is equivalent to test standard UL 1897-1.� *Design pressure margin of safety 2:1
�1 1tlf�
Locke BowdenP.E.does not have, not will acquire a financial in I a '� • L '
' P� q �ga�tn�iafacturing or distributing products
under this evaluation.
Locke Bowden, P.E. is not owned, operated, or controlled by a& coaiparkom b6iflhure , or distributing products under this
report.
� � • /is
r T C •Cc f
< % .
%.``TONAL