HomeMy WebLinkAboutPRODUCT APPROVAL - STEEL ROOF PANELI
so
N
St Lucie
Search Criteria
Aunty
Refine Search
Code Version
2017
FL#
17022.1
Application Type
ALL
Product Manufacturer
ALL
Category
ALL
Subcategory
ALL
Application Status
ALL
Compliance Method
ALL
Quality Assurance Entity
ALL
Quality Assurance Entity Contract Expired
ALL
Product Model, Number or Name
ALL
Product Description
ALL
Approved for use in HVHZ
ALL
Approved for use outside HVHZ
ALL
Impact Resistant
ALL
Design Pressure
ALL
Other
ALL
FL#
Tvoe
Manufacturer
Validated By
Status
FL17022-
Revision
Extreme Metal Fabricators, LLC
FL#: FL17022.1
Zachary R.
Priest, P.E.
Approved
RZ
History
Model: 1 - "5V Crimp" (R6)
(813) 480-3421
Description: 26 Gauge steel, 3/8";rib height, 24" wide lapped roof panel
mechanically attached to 15/32" plywood or Wood Deck with fasteners
Category: Roofing
Subcategory: Metal Roofing
Contact Us :: 2601 Blair stone Road. Tallahassee FL 32399 Phone: 850487-1824
The State of Florida is an AA/EE0 employer. Coovriaht 2007-2013 State of Florida.:: Privacy Statemer2 :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. 'Pursuant to Section 455.275(1),'
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails
provided may be used for official communication with the licensee However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public To determined you are a licensee under Chapter 455, F.S., please dick bere .
Product Approval Accepts: r
mom [GON sna_-
Credit Card
Safe
—RECEIVED
NOV NIB
ST. Lucie Countyr Permitting
I
Limitations:
1. Underlaym
2. Minimum s
3. Products a
4. Engineerin
5. Fire classif
6. SupportIra
Structural 1
7. This report
WE
FL17022.1 5V#mP (26GA Steel), U" Wide Roofa el - Details
I to be compliance with current Florida Building Code (FBC)2017 6th ed.
ipe to be compliant with Florida Building Code 2017 6th ed., and per with Manufacturer's installation reference.
i compliant for State of Florida product approval per Rule 61 G20-3. Compliance Method: 1-D
an for "project specific approval by local authorities w/jurisdiction is allowed by other registered engineers.
ation is not part of this acceptance. Shear diaphragm values are outside this report.
ling in compliance w/FBC 2017 6th ed., Chapter 22 for-Steei, Chapter 23 for Wood and Chapter 16 for
jading.
oes not imply warranty, installation, recommended product use outside of this report.
Fasteners -
#9 X 1-1 a- Min. or
#10 X 1-1/2' Min. per TeNe A' for Row 5-V Crimp Roof Panel
Spec/ng and Design Pressures
Hex Washer Head Wood Screws
Dedc
15W or greater Plywood, or
Wood plank
24-
12"
3Ar
T I /
T1 aPnotALSMAT )M
Panel Profile
_ Nominal 12" I Nominal 12"
O.C. 7 O.C.
Fasten
f9 x 1-1/2" Min. or #10 x 1-1/2" Min. per
Table "A" Hex,Washer Head Screw
Spaced 12" o.c. across the Panel Width
Panel Refer to Table "A" for Spacing Along Panel
Overlap Length
Deck-15/32" or greater
Plywood, or
-Wood plank
Compliant with Florida Building Code 2017 (6th ed.)
Compliant with Florida Product Approval Rule # 61G20-3
Compliant: Keystone Certifications
5 V Crimp 26GA Steel Roof Panel FBC Sec.1507.4.2
Palm City, FL 34990
S(, P NOD
Y
St Lucie County
Yield strength: 50 ksi min.; Attached to min.15/32" plywood or Wood
Deck w/ min. 0.42 specific gravity with screws. 24" Coverage
Rib Height 3/8"
i Resistant Compliant: FBC Sec.1507.4.3
Fastener 1(Method 1 Attachment): #9 x 1-1/2" Hex -Washer Head wood screw* to penetrate
3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length to meet
Fastene 2 (Method 2,3, & 4 Attachment): #10 x 1-1/2" Hex -Washer Head wood screw* to
penetrate 3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length
to meet requirements)
Underlayment: To be compliant with FBC Sec. Chart 1507.1.1
Slope: Shall be in compliance with FBC Sec.1S07.
See Fastener attachment snerifrr-atinne ahnua
Install Details: Table A Allowable Loads
METHOD 1
METHOD 2
METHOD 3
METHOD 4
DESIGN PRESSURE*
-86 PSF
-93.5 PSF
-101 PSF
-228 PSF
ROW SPACING
16" O.C.
16" o.c.
8" O.C.
6" o.c.
FASTENERS SPACING (ALONG Panel width)
12" o.c.
12" o.c.
12" o.c.
12"
FASTENERISIZE
#9
#10
#10
o.c.
#10
UL 580-06
TAS
Data: ARCHITECTURAL TESTING, INC. TST ID#:1527
i 1897-041 Test Report E(5893.01-450-18 05/02/14
Test Report F3366.01-450-18 12/18/15
1897-04
Test Report D05893.02-450-18
is equivalent to test standard UL 1897-1
Locke Bowdein, P.E. does not have, not will acquire a financial
07/22/14
*Design pressure margin of safety 2.1
•r.y�i�
or distributing products
under this evaluation. y ° ° • -1 0 A , -111
Locke Bowden, P.E. is not owned, operated, or controlled by a&- coaopadlipmif il&&ures, or distributing
report.
'1;: ONAL
products under this
KMI
fiber 29, 2018
Frechette Re -Roof
1078 Nettles Blvd.
Jensen Beach, FL
r
PAUL WELCH INC.
Mechanical Electrical Civil Engineering J
1984 S.W. Biltmore St. Suite#114
Port Saint Lucie, FL 34984
Phone (772) 785 - 9888
E-mail pwelchinc@aol.com
SCOPE OF WORK:
RenioVe existing roofing at low sloped roof. Install new self adhered roofing (Pollyglass SBS-
SA FL #1654.1) at above referenced address low sloped roof over existing plywood sheathing.
2017
E7-10
HULL
A= 3'
MEA, I
ROO]
SHk
ADJL
IMPR
WINI
WM
EXPC
LL
INNTEl
i
ECT DATA: RECEIVED
)ING HIEGHT=10'-0" N 0 V 0 2 2018
f ROOF HIEGHT = <20' ST. Lucie County, Permitting
ANGLE = 0.25:12
LOW SLOPED MONO
>TMENT FACTOR = 1.00
)TANCE FACTOR =1.00
VELOCITY V uit = 165MPH
VELOCITY V asd = 128 MPH
)URE = D
)SURE CLASS = ENCLOSED BUILDING
NAL PRESSURE COEFFICIENT = -0.18
1 (Field) = -43.3
2 (Perimeter/ Ridge) = -72.7
3 (Comers) = -109.4
i
I
1078 Nettles Blvd. Jensen Beach, FL
I
I
Paul Welch Inc.
Paul Welch P.E. Reg. No. 29945
October 29, 2018
1 of 3
Manufacturer: Polyglass USA
System No.: W-101 (page 19 of 65)
Fl+da Approval: FL# 1654.1
Design Pressure: .-112.5 PSF
Base Sheet: Elastobase or Elastobase P (poly -film top)
Ca Sheet / Ply: App — SA Self Adhered
B e Sheet Fasteners:
32 ga., 1-5/8-inch diameter tin,caps with i 1 ga. annular ring shank nails.
Note: Tin caps are to be primed with PG100 or ASTM D41 primer.
inch o.c. at min. 4-inch lap and 6-inch o.c. at four (4), equally spaced, staggered center rows
O'sign uplift Pressure for attachment as per above:
igrefore O.K.
Re -nail all plywood sheathing (19/32" thick minimum) with 8D ring -shank nails at 4" O.C.
perimeter and 6" O.C. field for all zones.
All work to be in compliance with product approval (FL # 1654.1), manufacturer's
specifications, and the Florida Building Code 2017.
Paul Welch Inc.
Paul Welch P.E. Reg. No: 29945
October 29, 2018
1078 ettles Blvd. Jensen Beach, FL 2 of 3
�i
o
l
i�
ROOF ZONE PLAN
A=3'
ZONE DESIGNATION (TYPICAL)
NOTE: ALL ZONES REQUIRE SAME ATTACHMENT.
1078. fettles Blvd. Jensen Beach, FL
Paul Welch Inc.
Paul Welch P.E. Reg. No. 29945
October 29, 2018
3 of 3