HomeMy WebLinkAbout2021-11-2 Landscape Plan17�
EXISTING
1 -
I
6'CHAINLINK
FENCE
I
I(
I
I
�
m
Qr
�
I
V
I
1Z
Q'I
UU
I
Q
-
I
w
v
I
PROPOSED
w
a
DUMPSTER
Z CJ
G-
Of
< ro
Q �
m
J K
Q
U
PROPOSED
I
zI
EXISTING
W
10'LAN BUFFER
BUFFER
�ELEC.PANEL
�
EXISTING
100 AID PAD
EXISTING
PAVERS PATH
O
EXISTING
/
BUILDING B
IOFFICE
1
5,000 S.F.
I�
/
Q
PROPOSFI,
W
5' CONCREI E
0)SIDEWALK
C0
W
O
Iz
M
d
2
r)
>Z
O
I_
O
M
Z
_O
U
W
L/)
LL
O
W
Z
J
H
U)
Q
W
GQ Q
J
O Lu
LC-.:,o
Q Z a co 0'
L l l M L
U � W
Qa0
PROPOSED
EXISTING LOADING ZONE
6'CHAIN I INK �12'X 55'
FENCE
sCD - 171111110 OP
'PET) CURB AD
I
�12' X SS'
m
TYPE "O"CURB Wr
NOTE
SOME OF THE TREES SHOWN TO BE REMOVED DO NOT
ME IO ET THE REQUIREMENTS FOR MITIGATN ANDMAV NOT
J4� APPEAR ON THE MITIGATION PLANS.
LL
M
EXISTING
LUMBER CATCH BASIN
�(TYR)
110
NOTE:
ANY EXISTING NATIVE TREES THAT CAN REMAIN IN THE
PERIMETER BUFFERS SHALL REMAIN AND BE CREDITED
TOWARDS REQUIRED PERIMETER BUFFER TREES.
EXISTING TREES TO REMAIN SHALL BE REVIEWED AND THE
PROPER CREDIT APPLIED TOWARDS THE REQUIRED TREES
SHALL BE GIVEN, THUS REQUIRING LESS PLANTED TREES
BASED ON THE CURRENT CODE REQUIREMENTS.
NOTE:
THE PERIMETER BUFFER HEDGES SHALL BE GROWN AND
MAINTAINED TO A MINIMUM HEIGHT OF 48".
EXISTING
1-STORY MANUFACTURING
BUILDING A
2590 KINGS HIGHWAY
FT. PIERCE, FLORIDA
63,750 S.F.
A/C PAD
EXISTING
CORD SLAB
RROPOSED
LOADING ZONE
12' X 55'
I
LUMBER
GAS TANK BARBED WIRE FENCE 332�2X4W Ca
'X40' COVERED AWNING
1,280 S.F. I
PROPOSED
10 LANDSCAPE
DUFFER
PNC:1336-231-0002A00-9
ee -Z I
heet
I
I
I
PARCEL 101336-231-0002-000-9
O.R.B. 3235, PAGE 2902
(VACANT)
LAND USE: NC
Note:
All existing tree locations are approximate. Sheet
I
PROPOSED
SWALE
.47 ACRES
(20,531 S.F.) 1-1
EXISTING
PUMP
HOUSE
EXISTING
RETENTION POND
�•1l- t63,907 S.F. (1 47 AC.)
(OUTLINE FROM APPROX SHORELINE)
(TO BE FILLED)
Landscape Data
7.09.04.A.1 - Perimeter Landscaping Adjacent to Orange Avenue Right-of-way
Total Length = 453.22'
Trees
Required - (1 Tree/301.f.)- 453.22 Lf./30 = 15 Trees
Provided - 15 Trees
14 Existing Trees + 1 Proposed Trees = 15
Shrubs
Required - Continuous Hedge 2' O.C. = 227 Shrubs
Provided - 227 Shrubs
7.09.04. B - Perimeter Landscapina Abuttina Adiacent Prooert
Total Length = 4,202.71'
Trees
Required - (1 Tree/301.f.)- 4,202.71 Lf./30 = 140 Trees
Provided - 140 Trees
20 Existing Trees + 120 Proposed Trees = 140
Shrubs
Required - Continuous Hedge 2'0. C. = 2,102 Shrubs
Provided - 2,102 Shrubs
7.09.04. C.3 - Terminal & Interior Island Trees
Trees
Required - 22
Provided - 22
6 Palms (2 Trees) + 2 Existing Trees + 18 Proposed Trees = 22
7.09.03.E.2.h - Required Tree Species Mix
Trees
Required - 4 1 + Trees = 5 Species Mix
Provided - 5 Tree Species
Existing Vehicle Pavement = 21,796
7.09.04. C - Interior Vehicular Use Area Proposed Vehicle Pavement = 62,721
1. V. U.A. = 84,517 s.f. Total Vehicular Use Area Pavement = 84,517 s.f.
84,517 s. f. / 18 s. f. = 4,695 s. f. / 180 s. f. = 26 Trees
Trees
Required - 26
Provided - 26
6 Palms (2 Trees) + 4 Existing Trees + 20 Proposed Trees = 26
Total Trees Required
Required - 181
Provided - 38 Existing + 143 Planted = 181
Note:
100% of proposed plantings are native. Total Shrubs Required
Required - 2,329
7.09.03.E.2.1- Planting Under Utility Lines Provided - Z329
Note: Small trees are being utilized to meet code section 7.09.03.E.2.L
No tree shall be planted where it could, at mature height, conflict with overhead power lines. Larger trees (trees with a mature height of thirty (30) feet or more)
shall be planted no closer than a horizontal distance of thirty (30) feet from the nearest overhead power line. Medium trees (trees with a mature height between
twenty (20)-thirty (30) feet) shall be off -set at least twenty (20) feet horizontally from the nearest overhead power line. Small trees (trees with a mature height of
less than twenty (20) feet) shall not be required to meet a minimum off -set, except that no tree, regardless of size shall be planted within five (5) feet of any existing
or proposed utility pole, guy wire, pad mounted electrical transformer or other utility transmission/ collection structure or equipment.
PCant.L'st
QTY
SYM
SPECIES
CANOPY
IORNAMENTAL
TREES
1
IC*
ILEX CASSINE
28
MG-1*
MAGNOLIA GRANDIFLORA
4
MG*
MAGNOLIA GRANDIFLORA
30
PE*
PINUS ELLIOTTI DENSA
13
QL*
QUERCUS LAURIFOLIA
63
QV*
QUERCUS VIRGINIANA
4
TD*
TAXODIUM DISTICHUM
PALMS
SP*
SABAL PALMETTO
LARGE SHRUBS
/ ACCENTS
227
FOS*
FORESTIERA SEGREGATA
2,105
MYR*
MYRICANTHES FRAGRANS
27
MYR-1*
MYRICANTHES FRAGRANS
MED. SHRUBS
/GROUNDCOVERS/
VINES /SOD
SOD
PASPALUM NOTATUM
* = FLORIDA NATIVE
COMMON NAME/DESCRIPTION SIZE SPACING REMARKS DROUGHT TOLERANCE
DAHOON HOLLY
LITTLE GEM MAGNOLIA
D.D. BLANCHARD MAGNOLIA
SOUTH FLORIDA SLASH PINE
LAUREL OAK
LIVE OAK
BALD CYPRESS
i.9.1:7:11911kyj
FLORIDA PRIVET
SIMPSON STOPPER
SIMPSON STOPPER
BAHIA SOD
GeneraCJVotes
12' x 5', 2.5" D.B.H.
A.S.
FULL CANOPY, 4' C.T. MIN.
HIGH
12' x 5', 2.5" D.B.H.
A.S.
FULL CANOPY, 4' C.T. MIN.
HIGH
12' x 5', 2.5" D.B.H.
A.S.
FULL CANOPY, 4' C.T. MIN.
HIGH
12' x 5', 2.5" D.B.H.
A.S.
FULL CANOPY, 4' C.T. MIN.
HIGH
12' x 5', 2.5" D.B.H.
A.S.
FULL CANOPY, 4' C.T. MIN.
HIGH
12' x 5', 2.5" D.B.H.
A.S.
FULL CANOPY, 4' C.T. MIN.
HIGH
12' x 5', 2.5" D.B.H.
A.S.
FULL CANOPY, 4' C.T. MIN.
HIGH
EXISTING
A.S.
RELOCATED FROM ON SITE
HIGH
#3, 2' x 2'
2' O.C.
FULL & THICK
HIGH
#3, 2' x 2'
Z O.C.
FULL & THICK
HIGH
#7, 4' x 2'
2' O.C.
FULL & THICK
HIGH
SEE SPECS HIGH
1. No plant substitutions can be made without St. Lucie County's approval.
2. All required landscape improvements must be inspected and approved by St. Lucie County prior to the issuance of a Certificate of Occupancy.
3. Any existing landscaping, sod, or irrigation damaged or destroyed during the construction shall be replaced prior to the final inspection.
4. All prohibited, exotic and invasive species shall be removed from the entire site prior to issuance of certificate of occupancy.
5. Planting adjacent to fire hydrants is to have a minimum clear radius of 7.5' as required by the NFPA Uniform Fire Code Florida Edition 18.3.4.1 Hydrants. All fire hydrants and fire
check valves shall have a minimum of 7.5' from the front and sides with 4' from the rear to all landscape material per the Florida Fire Prevention Code.
PROPOSED
10. LANDS CAPE
BUFFER
i BUFFER
4' BARBED WIRE FENCE CORNER 53.9' N I
41.2' N
-\ T.O.B. GATE POST GATE POST
4' BARBED WIDE FENCE
® DCH
89°50'S9"W
7268'N4I
,
DITCH ® - - - L -
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -------------_--------------_-- I
- - - _ - - - - - - - - - - - - - - - -
T.O.B. - - - -
° PROPOSED DITCH DITCH ll
9'53"F 10' LANDSCAPE I I
9644 BUFFER I
4' BAj�BED WIRE FENCE iJER
1441 ,2GTE
I
II
ANY NOTE: I NOTE:
X I
TURNAROUND
AEXISTING NATIVE TREES THAT CAN REMAIN IN THE � ANY EXISTING NATIVE TREES THAT CAN REMAIN IN THE I I I PERIMETER BUFFERS SHALL REMAIN AND BE CREDITED I PERIMETER BUFFERS SHALL REMAIN AND BE CREDITED I I
TOWARDS REQUIRED PERIMETER BUFFER TREES. 4 BARBED WIRE FENCE TOWARDS REQUIRED PERIMETER BUFFER TREES. I
66'S
EXISTING TREES TO REMAIN SHALL BE REVIEWED AND THE EXISTING TREES TO REMAIN SHALL BE REVIEWED AND THE
AFF,TEEFE"ND9°2D58"F PROPER CREDIT APPLIED TOWARDS THE REQUIRED TREES
SHALL BE GIVEN, THUS REQUIRING LESS PLANTED TREES I 76.84SHALL BE GIVEN, THUS REQUIRING LESS PLANTED TREES
BASED ON THE CURRENT CODE REQUIREMENTS. BASED ON THE CURRENT CODE REQUIREMENTS.
NOTE: NOTE: X l
THE PERIMETER BUFFER HEDGES SHALL BE GROWN AND THE PERIMETER BUFFER HEDGES SHALL BE GROWN AND I I I
^^^
MAINTAINED TO A MINIMUM HEIGHT OF 48". PROPOSED
GRAVEL AREA � - MAINTAINED TOAMINIMUM HEIGHT OF 48". I
® LUMBER RES N90°D9'DD"W z I
(33033044040 SF.) Ii II
I
921
ll
N39°09'49'W ��' Z �
41141411141441 PHASE 1 ca
0.40' 99 -
PDS ORDER 2020-042 X Oj
LESS & EXCEPT al
' I O.R.B 4455, P.G 1954 01
II I
ll I
I X ll ,
l I
I I I I
ll I
PARCEL ID: 1336-240-0000-000-3
PHASE
- (VACANT)
LAND USE:) I I I
II I
X II I I
I
PHASE LINE I I I
II I
X
X I I I
I
ll I
^� I I
a II I
N89°50'S9"W 432.93' l
NOT LOCATED NOT LOCATED
AS PART OF THIS UII
ll I I
X ll I
I I
. to
0 LuXz Ili U)
cc
�P AREA LL > 0 M
W llw
x LL
a Ili Z
i X
ca ZJIL` I I H
__
NOTE: ' --------------------- V �U
ANY EXISTING NATIVE TREES -------___ -- --____ aIIW I
THAT CAN REMAIN IN THE + ----®----------- z eta
PERIMETER BUFFERS SHALL - - - _ - - - - - _ _ _
REMAIN AND BE CREDITED -------_ DITCH -------_ 1-
0 I Cl)
TOWARDS REQUIRED PERIMETER ---------- ___ ---- I d
BUFFER TREES. EXISTING TREES �� ,-------- ____ 1 X Q' _
TO REMAIN SHALL BE REVIEWED ----- IO in
AND THE PROPER CREDIT
APPLIED TOWARDS THE ��� PARCEL ID: 13W-240-0000-000-3 Ida
REQUIRED TREES SHALL BE (VACANT) I
LAND USE: NC Ili I O
GIVEN, THUS REQUIRING LESS - I I I F-
PLANTED TREES BASED ON THE I
CURRENT CODE REQUIREMENTS l I M
NOTE: X Z
THE PERIMETER BUFFER WOOD
A /o O D
HEDGES SHALL BE GROWN AND Vk I PHASE 11 MAINTAINED AMINIMUM ROCK POND
HEIGHT OF 48". SHED V
(EMPTY) I It ; U)
O
I
X II I
PHASE 11 � 1 W
I �I W
!I
it �I 0
BARBED WIRE FENCE CORNER Z
I
� , VACANT 30.1'N, 234'E X m / Z
GIRT ROAD <_ LL
O I�
W
GRASS D_ I LL
o AREA ABANDONED WELL I LLI
ll I Z
1580
X l
l
l I
�0'
J
I H
n
o�
POWER POLE
ll
J
>w
>
I
PHASE I
I
GUYANCHORm�
X 1 1
I
I
4" VALVE AND PVC PIPE
t
I
FUTURE DEVELOPMENT
1 I
FUTURE ACCESS
GATE
I
BARBED WIRE FENCE
� I
t
GATE POST 14.5' S
DIRT ROAD
tl
I
-
I
GATE POST 15.0' S
T.O.B.
N8/.'.'1122032'
APPROXIMATE
SHORELINE
X X/ X
Y
„
I
�X
X X X
X
X
X�X
DI Mp
`
�
I
--
Lin
TrID'-------------
---------
------
-- ---
�-
----------
---- -----
Landscape Spect'
fications
1. All tree and plant material to be Florida No. 1 or better, as classified in "Grades and Standards for Nursery Plants", Part 1 and Part II, State of Florida, Dept. of Agriculture, Tallahassee. All plants not listed in "Grades and Standards for
Nursery Plants" shall conform to a Florida No. 1 as to: (1) health and vitality, (2) condition of foliage, (3) root system, (4) freedom from pest or mechanical damage, (5) heavily branched and densely foliated according to the accepted
normal shape of the species.
2. Undersizing or substitution of one species or cultivar for another species is a breach of contract and will be "Rejected" at the time of final landscape inspection unless approved by Landscape Architect.
3. Project Warranty: All plant material shall be warranted for a period of one (1) year after date of substantial completion against defects, including death and unsatisfactory growth, except for defects resulting from abuse or damage by
others or unusual phenomena or incidents which are beyond the contractor's control.
4. Any and all conditions which the contractor feels will be detrimental to the success of the planting shall be brought to the owner or representative's attention.
5. The contractor shall verify the location of underground utilities prior to commencing work on any project area.
6. Mulch planting areas with 3" layer of Melaleuca, Eucalyptus, or Enviromulch. Cypress Mulch is NOT ACCEPTABLE. Planting beds to receive mulch throughout entire bed area.
7. All plants to be set to ultimate grade. No filling will be permitted around trunks or stems. Mulch to be kept a minimum of 2" away from trunks and stems.
8. Planting trees and shrubs: Excavate hole per planting detail. When plant is set, place additional backfill consisting of a 50% mixture of Peat humus and natural soil around the base and sides of ball, and work each layer to settle backfill
and eliminate voids and air pockets. When excavation is approximately 2/3 full, water thoroughly before placing remainder of backfill. Water again after placing final layer of backfill and before installing mulch.
9. Guy and stake trees in 3 directions with galvanized wire, through flexible hose chafing guards, with wooden stake anchors immediately after planting. (See Detail)
10. Trees and shrubs shall be fertilized with a complete natural organic fertilizer with a ratio of approximately 3:0:2 or 3:0:3 (e.g. one labeled 12-0-8). Similar analysis such as 16-0-8 (4:0:2) can also be used. Fertilizers that are slow
release, controlled release, sulphur coated or with nitrogen as IBDU or ureaformaldehyde have extended release period. Thirty to fifty percent of the nitrogen should be water insoluble or slow release.
Palms should receive a complete granular fertilizer formulated for palms ("Palm Special") at a rate of 5 to 8 lbs. per palm.
Agriform 20-0-5 twenty-one gram planting tablets may be substituted for granular fertilizer. If utilized, the following rates
shall be utilized: Position plant in hole. Backfill halfway up the rootball. Place tablet(s) beside rootball about 1" from root
tips. Do not place tablet(s) in bottom of hole.
1 Gallon 1 Tablet
3 Gallon 2 Tablets
25 Gallon & B&B Trees 2 per l" caliper
11. All planting areas to be irrigated to provide 100%O coverage. Shop drawings to be submitted by the irrigation contractor for approval prior to installation.
12. Maintain trees, shrubs, and other plants by watering, cultivating, and weeding as required for healthy growth. Restore planting saucers and mulch. Tighten and repair stake and guying and reset trees and shrubs to proper grade or
vertical position as required. Spray as necessary to keep trees and shrubs free of insects and disease. The contractor shall begin maintenance immediately after planting and shall continue maintenance through final acceptance when
Certificate of Occupancy is issued to the General Contractor by County and project is released by the General Contractor to Client.
13. Prune trees and shrubs only to remove damaged branches as directed by the Landscape Architect.
14. Planting Lawns: Provide clean, strongly rooted, uniformly sized strips of Stenotaphrom secundatus Floritam (unless otherwise noted), machine stripped not more than 24 hours prior to laying. Grade and roll prepared lawn surface.
Water thoroughly but not to create muddy soil conditions. Lay sod strips with tight joints, roll or tamp lightly, and water thoroughly.
15. Maintain positive drainage, no planting is to block drainage.
16. Drainage Testing
Prior to planting of trees, palms, and specimen material, each planting pit shall be tested in the following manner to verify adequate drainage.
A) Dig each planting pit to the minimum specified size.
B) Fill the planting pit with (12") twelve inches of water. If the water level in the planting pit drops (4") four or more inches within (4) four hours, the drainage is sufficient and a drainage channel is not required. If
the water level drops less than (4") four inches within the (4) four hour period, then a drainage channel is required.
C) When a drainage channel is required, the drainage channel must extend down through the non porous soil and into porous soil. (See Drainage Testing Detail)
D) Discard all material removed from the drainage channel.
E) When backfilling the planting pit, add course gravel to the drainage channel. Also, care must be taken to keep the consistency of the soil mix the same throughout the planting pit.
NOTES:
1. Contractor to include drainage testing for all trees and palms in bid. If drainage is inadequate, the soil specification in item #8 above shall be revised for site conditions. Contractor
shall notify the Owner and Landscape Architect of poor drainage conditions in writing and written direction will be provided to the contractor of appropriate soil mixture specification to
be used.
2. All fertilizers shall meet the St. Lucie County fertilizer ordinance.
ELECTRONIC SIGNATURE AND SEAL
Registered Landscape Architect
Jeffrey WSomitth, RLA Digitally signed by Jeffrey W. Smith, RLAIan ca e
Prepared, Reviewed & Supervised By: A
Conceptual Ocean
nulevar lSu Date. 2021 .09.24 12:50:03-04�00�
900 East Ocean Boulevard, Suite 130d
Stuart, Florida 34994
(772)344-2340 LC:26000198
Plan
North
Scole: I" = 100'
0 50' 100' 200'
Conteitual
Demo
(
r nc. Go ,
Landscape ArdtitPctnrP - Site Planning
900 East Ocean Boulevard, Suite 130d
Stuart, Florida 34994
(772) 344-2340
LC: 26000198
C/)
O
O
Q)
J
County Project
Number:
Jeffrey W Smitb, RLA
Florida Registration Number:
LA 0001635
Job No. 21-0108
Drawn By JWS
Submittal Dates 4-27-2021
9-17-2021
Revision Dates
Comments #1 9-17-2021
These drawings are the property of the
landscape architect and are not to be
used for other projects except by written
permission from the landscape architect.
Report any discrepancies immediately
to the landscape architect.
L-7 6
Sheet of
Ec,
74'
I
I
I
O
I �
N
I
I
LO
I
}-
CD
I
Q
I
I
�
�
O
o�
I
I
I
=
O
O
O
O
I
m
I
W
I
0
_X X X X X X���X
M
I �
r)
W
W
r)
Z
Q
ry
00
>Q �
00
J
O
U
W
n
U)
GATE
ReCocate Existing Patm
Saba( to remain
PaCms (7yp.)
0
I %<
EXISTING
( I 6' CHAIN LINK
FENCE j
I
� I
= I W
I0-10
I
I .I er I
I 14
1 T rC U UUMD
.�lll<1��"im
/ 9a�
370 -,,aea,
PaCms
QV
20
Q /6
--- -----------
ffn
PROPOSED
DUMPSTER
MLo
—
j
0 I f�• \1
I � / � YR-
27
227I I
I \ Qv I
I
d- MG I I
� M 4
INI :I
PROPOSED EXISTING
10 LANDSCAPE l C) ELEC. PANEL
BUFFER z I \ : L
EXISTING
° A/C PAD
� o
EXISTING
i - PAVERS PATH
50'
J�I I
I I
/ I
:V
EXISTING
I CD OFFICE o
3 / BUILDING B
5,000 S.F.
( 1 YR
I I 370 I
3 1�
50'
+ + V \ x
13
1 HYD
EXISTING
GAS TANK
12'X55'
gigmi
r
I � •
TYPE "D" CURB
1
7r2e to be'—J
` removed
ReCoeate Tree to (7ypJ
Saba( remain
PaCms (7ypJ (PROPOSED PARKING AREA)
NOTE:
SOME OF THE TREES SHOWN TO BE REMOVED DO NOT
MEET _THE _REQUIREMENTS FOR _MITIGATION _AND MAY NOT
AP -I IPEAR ON THE MITIGATION PLANS
I
EXISTING
EXISTING CATCH BASIN
LUMBER (TYP)
,STORAGE AREA,
1
I
250'
NOTE:
ANY EXISTING NATIVE TREES THAT CAN REMAIN IN THE
PERIMETER BUFFERS SHALL REMAIN AND BE CREDITED
TOWARDS REQUIRED PERIMETER BUFFER TREES.
EXISTING TREES TO REMAIN SHALL BE REVIEWED AND THE
PROPER CREDIT APPLIED TOWARDS THE REQUIRED TREES
SHALL BE GIVEN, THUS REQUIRING LESS PLANTED TREES
BASED ON THE CURRENT CODE REQUIREMENTS.
NOTE:
THE PERIMETER BUFFER HEDGES SHALL ,BE GROWN AND
MAINTAINED TO A MINIMUM HEIGHT OF 48.
N N
Cn �
EXISTING
1-STORY MANUFACTURING
BUILDING A
2590 KINGS HIGHWAY
FT. PIERCE, FLORIDA
63,750 S.F.
EXISTING
A/C PAD
EXISTING
CONIC SLAB
250'
FM
BARBED WIRE FENCE
N89050'59"W
t- '—
v■
r
�
ReCocate —Y
Saba(
Palms
i
PROPOSED
i f-NnrNIMIf+ -7f-%nir
1130.59'
EXISTING
32'X40' COVERED AWNING
1,280 S.F.
PROPOSED
PROPOSED
5' CONCRETE 10' LANDSCAPE ADJACENT PARCELSIDEWALK BUFFER PNC:1336-231-0002-000-9
,ONWER:PHILIP C GATES
Landscape Plan
North
Scale: I " = 30'
0 15' 30' 60'
Con_ ce tua�
p
esz
LanrtscaprArd ital re - Si1c Pl nning
900 East Ocean Boulevard, Suite 130d
Stuart, Florida 34994
(772) 344-2340
LC: 26000198
■ V
i
0
0
Q)
u
.Q)
J
rr�
vJ
County Project
Number:
Jeffrey W Smitb, RTA
Florida Registration Number:
LA 0001635
Job No. 21-0108
Drawn By JWS
Submittal Dates 4-27-2021
9-17-2021
Revision Dates
Comments #1 9-17-2021
These drawings are the property of the
landscape architect and are not to be
used for other projects except by written
permission from the landscape architect.
Report any discrepancies immediately
to the landscape architect.
L-2 6
Sheet of
landscape Plan
North
Scole: 7 " = 30'
15' 30' 60'
o ce tz�a�
Goo , nc.
p
LandscapeArcfiitecture - Site Planning
900 East Ocean Boulevard, Suite 130d
Stuart, Florida 34994
(772) 344-2340
LC: 26000198
CO�+
■ V
i
_O
U
O
yr
V
J
CIO
C/0
County Project
Number:
Jeffrey W Smitb, RLA
Florida Registration Number.•
LA 0001635
Job No. 21-0108
Drawn By JWS
Submittal Dates 4-27-2021
9-17-2021
Revision Dates
Comments #1 9-17-2021
These drawings are the property of the
landscape architect and are not to be
used for other projects except by written
permission from the landscape architect.
Report any discrepancies immediately
to the landscape architect.
L-3 6
Sheet of
� � I
----___—_---/ I
11
II
II
II
I�
x
III
I I
I I
III
I,
I
II
II
II
X
4' BA�BED
14.4';, 26
II
II
X II
II
II
II
II
II
II
II
X l
II
II
II
II
I
II
I I
II
X II
I I
I I
I I
I I
I
I I
I I
I I
X l
I I
I I
I I
I j
I I
I I
I I
X II
I
I I
I I
I I
I I
I
I I
I I
I I
X I I
I I
I !
I
I j
I
I I
I
X
I I
LL
( I
I
I I
M I I
W I
I I
X I
I I
I I
OI
I I
I I
I I
X n I
I.i I I
I
I I
OII
I I
I I
I I
X I
I I
I I
I I
I I
I
I I
I I
X I
I I
I I
I I
I j
I I
I I
I I
x I
I I
I I
I I
I I
I I
I I
I I
I I
X I
I I
I I
I I
I
I I
I I
I I
I I
X
I
I I
I I
I I
I I
I
I I
I
X I
I I
I I
I I
I I
I I
I I
I I
I
X
ILL
I I
ILL
ILL
I
I I
I I
I
I I
I I
I
X I
I I
ILL
I I
I I
I
I I
I
I I
I I
I
X
I I
I I
I I
- I I
I I
I I
I
X II
II
II
I
II
II
II
X II
II
II
II
II
II
II
II
x I
I
II
II
I
II
I I
I I
I I
I I
x
II
I
+I U
I
x iz
II�
II
I 0
II
I I
x II
I�
I I
W 'o
II
U z
I
it
Z X lz
I
I
W IlO
r II
WIRE FENCE
3' E
I
I
I
I
I
I
I
I
I
I
I
I
II
I
I
II
I
I
I
I
I
I
C R' NER
I
I
I
II
I
I
I
I
I
I
I
I
I
I
I
II
I
I
I
II
I
I
I
I
I
I
I
I
I
I
I
II
I
I
II
I
I
I
I
I
I
I
I
I
I
I
I
I�
I
I
I'
I
I
I
I
I
I
I
I
I
I
II
III
I
I
I
I
I
I
II
I
I
I
I
I
I
I
I
I
II
I
I
I
II I
I
I
I
I
I
I
I
I
I
I
I
II
I
I
II
I
I
I
I
I
I
I
I
I
I
I
I
I
II I
I
II
I
I
I
I
I
I
I
I
I
I
I
I
II
I
I
I
I' I
I
I
I
I
I
Q
W
Landscape Plan
North
Scole: I ' = 30'
7 15' 30' 60'
once tua�
p
GandwtaprArd ital re - Si1c Pl nning
900 East Ocean Boulevard, Suite 130d
Stuart, Florida 34994
(772) 344-2340
LC: 26000198
col
(U
■ V
i
O
LL
O
V
0
�
v
J
00
County Project
Number:
Jeffrey W Smitb, RTA
Florida Registration Number:
LA 0001635
Job No. 21-0108
Drawn By JWS
Submittal Dates 4-27-2021
9-17-2021
Revision Dates
Comments #1 9-17-2021
These drawings are the property of the
landscape architect and are not to be
used for other projects except by written
permission from the landscape architect.
Report any discrepancies immediately
to the landscape architect.
L-4 6
Sheet of
T
PROPERTY LINE
� �15
6
1585
\N
X /
1184
21
i
'1_1�15
3
0
`
NOTE:
ANY EXISTING NATIVE TREES
THAT CAN REMAIN IN THE
PERIMETER BUFFERS SHALL
REMAIN AND BE CREDITED
TOWARDS REQUIRED PERIMETER
15
2
BUFFER TREES. EXISTING TREES
�--/
TO REMAIN SHALL BE REVIEWED
AND THE PROPER CREDIT
APPLIED TOWARDS THE
REQUIRED TREES SHALL BE
GIVEN, THUS REQUIRING LESS
PLANTED TREES BASED ON THE
CURRENT CODE REQUIREMENTS
NOTE:
V THE PERIMETER BUFFER
HEDGES SHALL BE GROWN AND
MAINTAINED TO A MINIMUM
HEIGHT OF 4811
.
�1581
21 )l79
,�1 �580
/ }
/
/
/
+ PHASE 11
/
A -
IX
w00E
SHED
�IO
0 0
02
f
0 f
14` 7
17,717
.
D I RT ROAD
f
I
f
I f
I +
Z
CD
CD0 CD
N I
04 O O
Cn I CO
m
FUTURE DEVELOPMENT
FUTURE ACCESS
I
PHASE 11
• \\1m I" v,: , ���1I �y� o \hlo+l- \��il, \S,hi hi i p\ ���nn i( m�
•••••E�•••�a••••••••E�.�•�'a••r ���_�•E�•����••••••••E••••jai•••••�•E'!••��•••••i••E�•••4�:a••••••••�a�����•••y�••��E������••••••••�!••••:�•••••••••
GATE POST 15.0' S
X X X
Landscape Details
- Spread -
Qt
,m
v
(5) 2" x 4" x 18" woodbattens to be evenly
spaced around trunk of tree..A minimum
of (5) five wraps of burlap are to be placed
under the battens to prevent marring or
damage to the trunk. The height of the
battens shaCCbe COcatedin reCation to the
height of the tree for adequate bracing. No
batten is to be nailed to the tree. Battens
are to be bandedwith a minimum of (2) two
314 " high carbon steel bands.
alinimum of (3) three 4" x 4" •woodbraces
evenly spaced around tree to be toe nailed to
woodbattens. -AttachfCorescent safety flags
a min. Of 12" in Length to each woodbrace.
Planting depth shaClbe to% Cess than the
height of the root baCCfrom the Flair Root.
Diameter of hole to be three times the size
of root baClminimum. Plant top of root ball
at 2" minimum above the finished grade
elevation.
Form a mulch berm with 3" minimum depth
andno more than 4" high_ Mulch to edge of
rootbaCC but leave top of rootbaCCexposed
Remove burlap or steeCcage from top 1/3 of
root balf(If applicable).
Finished Grade
Drive 2" x 4" x 24" woodstake a min. Of 3"
betbw grade.
3 times diameter BackfiCCaroundroot baCCaccording to
I of rootbad (Min.) specifications. Water and tamp to remove
Notes: air pockets.
1..ACCpruning shalCbe compltedat the
direction of the landscape .Architect.
2. No nails shallbe driven into tree
Large free PCantln� Detail (5" Caliper or Greater)
Not to Scale
Spread
o
v
d
Q
Place 112" diameter black rubber hose on
aCCguy wires at aCCpoints of contact with
tree.
Place 3 galvanizedsteet'doubte strand#I2
gauge twisted guy wires with one
galvanized turnbuckle per guy wire
spacedat equaCdistance aroundtree.
.Attach fCorescent safety flags a min. of i2"
in length to each guy wire.
Planting depth shaCCbe io% Cess than the
height of the root baCCfrom the Flair Root.
Diameter of hole to be three times the size
of root baCCminimum. Plant top of root
baClat 2" minimum above the finished
grade elevation.
Form a mulch berm with 3"minimum
depth andno more than 4" high. Mulch to
edge of rootbaC� but leave top of rootbaCC
exposed
Remove burlap or steeCcage from top 1/3
of root balC(If applicable).
Finished Grade
Drive 2"x4"x24"woodstake amin- Of3"
� I I I I I I —I 11=1 11=1 11=1 11=1 11=1 11=1 11= '
bet6w grade.
_ 3 times diameter - I BackfiCCaroundroot baCCaccording to
r of rootball (Min.) , specifications. "Water and tamp to remove
Notes: air pockets.
1. Adpruning shatibe completedat the
direction of the landscape .Architect.
2. No nails shalCbe driven into tree
Ire e Planting D e tail
Not to Scale
Spread
Place 1/2" diameter black rubber Grose on
aCCguy wires at aCCpoints of contact with
tree.
Place 3 galvanizedsteeldoubCe strand#12
gauge twisted guy wires with one
galvanized turnbuckle per guy wire
spacedat equaCdistance aroundtree.
.Attach fCorescent safety flags a min. of i2"
in Length to each guy wire.
Planting depth shaCCbe io% Cess than the
height of the root baCCfrom the Flair Root.
Diameter of hole to be three times the size
of root baCCminimum. Plant top of root
baCCat 2" minimum above the finished
grade elevation.
Form a mulch berm with 3" minimum
depth andno more than 4" high. 9vlutch to
edge of rootbaCC but leave top of rootbaCC
exposed
Remove burlap or steelcage from top 1/3
of root balC(If applicable).
Finished Grade
Drive 2" x 4" x 24" woodstake a min. of 3"
bet6w grade.
3 times diameter BackfiCCaroundroot baCCaccording to
of root6aCC(Min.) specifications. "Water and tamp to remove
Notes: air pockets.
i. ACCpruning shatibe completedat the
direction of the Landscape .Architect.
2. No nails shalCbe driven into tree
_Multi -Trunk Tree Planting Detail
Not to Scale
Prune & tie aCCfronds together with
degradable twine. There is to be a
minimum of 6-8 fronds (unless notedbeCow).
(5) 2" x 4" x 18" woodbattens to be evenly
spacedaroundtrunk ofpafm..Aminimum
of(5)five wraps of burlap are to be pCaced
under the battens to prevent marring or
damage to the trunk. The height of the
battens shaCCbe COcatedin reCation to the
height of the palm for adequate bracing.
No batten is to be nailed to the palm.
Battens are to be bandedwith a minimum
of (2) two 314" high carbon steeCbands.
Minimum of (3) three 4" x 4" woodbraces
evenly spacedaroundpalm to be toe
nailed to woodbattens. .Attach fCorescent
safety flags a minimum of i2" in length to
each brace
Planting depth shaCCbe io% Cess than the
height of the root gaff Diameter of hole to
be two times the size of root baCCminimum.
Plant top of root baCCat 2" minimum above
the finished grade elevation.
Form a mulch berm with 3"minimum
depth andno more than 4" high. -'Mulch to
edge of rootbaC� but leave top of rootbaCC
exposed
BackfiCCaroundroot baCCaccording to
specifications. Water and tamp to remove
airpockets.
Finished Grade
2" x 4" x 24" woodstake to be 2" below
grade.
Size of rootbaffwiCCbe inproportion to type
Notes: andsize ofpalm, in accordance with
,. Hurricane cur sa6aCPaCms are acceptable. Florida Grades andStandards for Nursery
2. ACCti9ashingtonia andSabat'Paims to be booted
unless otherwise notedinpCant list. Plants Part I & II Latest Edition.
3. Palms with burnedor marredtrunks wilCnot be
accepted
PaCm Planting Detail
Not to Scale
Place 1/2" diameter black rubber hose on aCC
guy wires at aCCpoints of contact with tree.
Place 3 galvanizedsteeCdouble strand#12
gauge twisted guy wires with one galvanized
turnbuckle per guy wire spacedat equal
distance aroundtree above the first lateral
branch. .Attach fCorescent safety flags a min.
of i2" in Length to each guy wire.
Tree Trunk
�u•y 'Wire .Attachment Detail
Not to Scale
Pl
Staking Detail
Not to Scale
Dra
2" x 4" x 24"Long stake
Guy wire or woodbracing
Tree Pit
Root BaCC
Tree Trunk
12" depth of water
Finishedgrade
Non porous soil
Porous soil
6" diameter drainage channel
Note:
Refer to planting details for sue of
pCantingpit Rootbafl
Finishedgrade
Planting mix
•:1`6
}. w�i• .. A- a "J.�• 4 ..: ;51e
$'' Non orous soil
Porous soil
6" diameter drainage channeffiCCed
with course gravel DiscardmateriaC
Plantedpit with inadequate drainage removedfrom drainage channel
Drainage Testing Detail
Not to Scale
3" minimum depth of mulch. Xeep mulch
away from base of stem (See specifications)
Planting depth shaClequafdepth of root
ball Diameter of hole to be twice the size
of root ball For root balls Carger than Yin
diameter, the hole shoufdbe 2' wider than
root baCCon aliCsides. Plant top of root gaff
at same elevation as finished grade.
III -III I E `� Finished Grade
Form 3" continuous earthen rim around
y1anting hole.
=11111= I=III "- BackfiCCaroundroot baCCaccording to
Notes: specifications. Water and tamp to remove
i..AlCpruning shallbe completedat the
direction of the Landscape .Architect. air pOCketS.
2. Remove any container from aroundrootball
3. PCanr as hedge row with O.0 (on center) Place root ball at bottom of undisturbed
spacing as specified in plant list, or with subgrade of planting pit.
triangular spacing as a mass.
Shrub Detail
Not to Scale
Section
O.C. Spacing �/
Plan
1�round-Cover Detail
Not to Scale
landscape Plan
See Plant List for O.C. (on center) spacing
3" minimum depth of mulch. Xeep mulch
away from base of stem (See specifications)
Planting depth shaClequafdepth of root
ball Diameter of hoCe to be twice the size
of root ball Plant top of root baCCat same
elevation as finished grade.
Finished Grade
BackfiCCaroundroot baCCaccording to
specifications. Water and tamp to remove
air pockets.
Place root baCCat bottom of undisturbed
subgrade of planting pit.
3" minimum depth of mulch. Xeep mulch
away from base of stem (See specifications)
.Alternate spacing ofytants to insure
proper coverage of groundcover
(Triangulate planting)
Edge ofpCanting bed
North)
Scale: 1 " = 30'
0 75' 30' 60'
o ce tua�
S
Gro nc.
LandscapeAychile(6ufe -Site X,anniny
900 East Ocean Boulevard, Suite 130d
Stuart, Florida 34994
(772) 344-2340
LC: 26000198
■ V
i
C)
W
CJ
J
■
County Project
Number.'
Jeffrey W Smitb, RLA
Florida Registration Number
LA 0001635
Job No. 21-0108
Drawn By JWS
Submittal Dates 4-27-2021
9-17-2021
Revision Dates
Comments #1 9-17-2021
These drawings are the property of the
landscape architect and are not to be
used for other projects except by written
permission from the landscape architect.
Report any discrepancies immediately
to the landscape architect.
L-5 6
Sheet of
LUMBER 1 LUMBER �ptcac5o'Secttobn -fake fittoraCPCan
STORAGE AREA STORAGE AREA
Not to scale
Edge of water
N CAF�A7
SPB JUE CRA
II -rT-� 7 15 A 15 7 7
Littoral
Planting
i
EXISTING
PUMP
HOUSE
Z,L.pCandBuffer Section PCantlist
TOTAL QTY QTY/SECTION SPECIES COMMON NAME SIZE SPACING
upland
Planting
14 1 ACER RUBRUM RED MAPLE 12' x 6, 2.5" CAL. A.S.
15 1 TAXODIUM DISTICHUM BALD CYPRESS 12'x 6, 2.5" CAL. A.S.
174 6 CALLICARPA AMERICANA BEAUTY BERRY #1, 12" x 12" 36" O.C.
145 5 CANNA FLACCID GOLDEN CANNA #1, 12" x 12" 36" O.C.
406 14 MUHLENBERGIA CAPILARIS MUHLEY GRASS #1, 12" x 12" 36" O.C.
348 12 MYRICA CERIFERA WAX MYRTLE #1, 12" x 12" 36" O.C.
290 10 OSMUNDA CINNAMOMEA CINNAMON FERN #1, 12" x 12" 36" O.C.
145 5 SERENOA REPENS SAW PALMETTO #3, 12" x 12" 36" O.C.
725 25 SPARTINA BAKERI SAND CORDGRASS #1, 12" x 12" 36" O.C.
1,450 L.F. of Shoreline / 50' Sections = 29 Sections
Notes:
1. All plant materials shall be planted and maintained in a natural arrangement.
2. The Upland Buffer shall consist of native vegetation only and shall be maintained permanently as part of the surface water management system.
3. The Upland Buffer vegetation shall be planted such that no less than 50 percent of the total shoreline is buffered by a minimum width of 10 feet of
upland buffer.
Requirements:
6.2.3.F. - Required Buffering - A buffer zone of native upland edge (i.e., transitional) vegetation shall be provided and maintained around isolated
wetlands covered by this Section which are constructed or preserved on new development sites. The buffer zone may consist of preserved or
planted vegetation but shall include canopy, understory, and ground cover of native species only. The edge habitat shall begin at the upland limit of
any wetland or deepwater habitat. As a minimum, ten (10) square feet of such buffer shall be provided for each linear foot of wetland or deepwater
habitat perimeter that lies adjacent to uplands. This upland edge habitat shall be located such that no less than fifty percent (50%) of the total
shoreline is buffered by a minimum width of ten (10) feet of upland habitat. The upland buffer requirement does not apply to drainage canals or
stormwater conveyance systems requiring periodic maintenance.
TyytcaC50'UyCandJ3uffer Section
Not to Scale
(5) Golden Canna
(25) Sand Cordgrass
(5) Saw Palmetto
(12) Wax Myrtle
PROPERTY LINE
;�; W. • W W W
411
ItttoraCZone PCant
10' Littoral Shelf J
It's t Stiore Line Length of Punting = 1,450' = 29 Sections
TOTAL QTY
QTY/SECTION
SYM
SPECIES
COMMON NAME/DESCRIPTION
SIZE
SPACING
REMARKS
203
7
CAF*
CANNA FLACCIDA
GOLDEN CANNA
BARE ROOT
3' O.C.
SHORELINE - 3" DEPTH
203
7
CRA*
CRINUM AMERICANUM
SWAMP LILY
BARE ROOT
3' O.C.
SHORELINE - 3" DEPTH
406
14
ELS*
ELEOCARIS INTERSTINCTA
SPIKERUSH
BARE ROOT
3' O.C.
6-18" DEPTH, CLEAN, WEED FREE
203
7
IRV*
IRIS VIRGINICA
SOUTHERN BLUE FLAG IRIS
BARE ROOT
3' O.C.
SHORELINE - 3" DEPTH
435
15
JUE*
JUNCUS EFFUSUS
SOFTRUSH
BARE ROOT
3' O.C.
SHORELINE - 3" DEPTH
160
10
NYO*
NYMPHAEA ODORATA
FRAGRANT WATERLILY
BARE ROOT
7' O.C.
24" ROOT, 2-3' DEPTH, CLEAN, WEED FREE
406
14
SAS*
SAGITTARIA SPP.
ARROWHEAD
BARE ROOT
T O.C.
24" HT, 6"-2' DEPTH, CLEAN, WEED FREE
435
15
SPB*
SPARTINA BAKERI
SAND CORDGRASS
4" LINER
2' O.C.
SHORELINE - 6" DEPTH
406
14
POC*
PONTEDERIA CORDATA
PICKEREL WEED
BARE ROOT
3' O.C.
24" HT, 6"-2' DEPTH, CLEAN, WEED FREE
* = FLORIDA NATIVE
100% Native Plantings
Pl6antin,q
Detail
Growng tips extend
above water
'ontroC EC.
Tamp roots firmly
into native soil
Native soil
Genera,CXotes
1. All plant materials shall be planted and maintained in a natural arrangement.
2. The littoral zone shall consist of native vegetation only and shall be maintained permanently
as part of the surface water management system.
3. Lake management plans shall comply with St. Lucie County & South Florida Water
Management District rules and shall be subject to approval by the St. Lucie County.
landscape Plan
North
Scale: I " = 30'
0 15' 30' 60'
Conte tua�
p
De
Gyou , nc.
p
Gatldstvpe ArdtileGlnye - Site XannEng
900 East Ocean Boulevard, Suite 130d
Stuart, Florida 34994
(772) 344-2340
LC: 26000198
C/)
■ V
i
0
�
v
a�
J
rr�
vJ
C/0
County Project
Number:
Jeffrey W Smith, RLA
Florida Registration Number:
LA 0001635
Job No. 21-0108
Drawn By JWS
Submittal Dates 4-27-2021
9-17-2021
Revision Dates
Comments #1 9-17-2021
These drawings are the property of the
landscape architect and are not to be
used for other projects except by written
permission from the landscape architect.
Report any discrepancies immediately
to the landscape architect.
L-6 6
Sheet of