Loading...
HomeMy WebLinkAbout2021-11-2 Landscape Plan17� EXISTING 1 - I 6'CHAINLINK FENCE I I( I I � m Qr � I V I 1Z Q'I UU I Q - I w v I PROPOSED w a DUMPSTER Z CJ G- Of < ro Q � m J K Q U PROPOSED I zI EXISTING W 10'LAN BUFFER BUFFER �ELEC.PANEL � EXISTING 100 AID PAD EXISTING PAVERS PATH O EXISTING / BUILDING B IOFFICE 1 5,000 S.F. I� / Q PROPOSFI, W 5' CONCREI E 0)SIDEWALK C0 W O Iz M d 2 r) >Z O I_ O M Z _O U W L/) LL O W Z J H U) Q W GQ Q J O Lu LC-.:,o Q Z a co 0' L l l M L U � W Qa0 PROPOSED EXISTING LOADING ZONE 6'CHAIN I INK �12'X 55' FENCE sCD - 171111110 OP 'PET) CURB AD I �12' X SS' m TYPE "O"CURB Wr NOTE SOME OF THE TREES SHOWN TO BE REMOVED DO NOT ME IO ET THE REQUIREMENTS FOR MITIGATN ANDMAV NOT J4� APPEAR ON THE MITIGATION PLANS. LL M EXISTING LUMBER CATCH BASIN �(TYR) 110 NOTE: ANY EXISTING NATIVE TREES THAT CAN REMAIN IN THE PERIMETER BUFFERS SHALL REMAIN AND BE CREDITED TOWARDS REQUIRED PERIMETER BUFFER TREES. EXISTING TREES TO REMAIN SHALL BE REVIEWED AND THE PROPER CREDIT APPLIED TOWARDS THE REQUIRED TREES SHALL BE GIVEN, THUS REQUIRING LESS PLANTED TREES BASED ON THE CURRENT CODE REQUIREMENTS. NOTE: THE PERIMETER BUFFER HEDGES SHALL BE GROWN AND MAINTAINED TO A MINIMUM HEIGHT OF 48". EXISTING 1-STORY MANUFACTURING BUILDING A 2590 KINGS HIGHWAY FT. PIERCE, FLORIDA 63,750 S.F. A/C PAD EXISTING CORD SLAB RROPOSED LOADING ZONE 12' X 55' I LUMBER GAS TANK BARBED WIRE FENCE 332�2X4W Ca 'X40' COVERED AWNING 1,280 S.F. I PROPOSED 10 LANDSCAPE DUFFER PNC:1336-231-0002A00-9 ee -Z I heet I I I PARCEL 101336-231-0002-000-9 O.R.B. 3235, PAGE 2902 (VACANT) LAND USE: NC Note: All existing tree locations are approximate. Sheet I PROPOSED SWALE .47 ACRES (20,531 S.F.) 1-1 EXISTING PUMP HOUSE EXISTING RETENTION POND �•1l- t63,907 S.F. (1 47 AC.) (OUTLINE FROM APPROX SHORELINE) (TO BE FILLED) Landscape Data 7.09.04.A.1 - Perimeter Landscaping Adjacent to Orange Avenue Right-of-way Total Length = 453.22' Trees Required - (1 Tree/301.f.)- 453.22 Lf./30 = 15 Trees Provided - 15 Trees 14 Existing Trees + 1 Proposed Trees = 15 Shrubs Required - Continuous Hedge 2' O.C. = 227 Shrubs Provided - 227 Shrubs 7.09.04. B - Perimeter Landscapina Abuttina Adiacent Prooert Total Length = 4,202.71' Trees Required - (1 Tree/301.f.)- 4,202.71 Lf./30 = 140 Trees Provided - 140 Trees 20 Existing Trees + 120 Proposed Trees = 140 Shrubs Required - Continuous Hedge 2'0. C. = 2,102 Shrubs Provided - 2,102 Shrubs 7.09.04. C.3 - Terminal & Interior Island Trees Trees Required - 22 Provided - 22 6 Palms (2 Trees) + 2 Existing Trees + 18 Proposed Trees = 22 7.09.03.E.2.h - Required Tree Species Mix Trees Required - 4 1 + Trees = 5 Species Mix Provided - 5 Tree Species Existing Vehicle Pavement = 21,796 7.09.04. C - Interior Vehicular Use Area Proposed Vehicle Pavement = 62,721 1. V. U.A. = 84,517 s.f. Total Vehicular Use Area Pavement = 84,517 s.f. 84,517 s. f. / 18 s. f. = 4,695 s. f. / 180 s. f. = 26 Trees Trees Required - 26 Provided - 26 6 Palms (2 Trees) + 4 Existing Trees + 20 Proposed Trees = 26 Total Trees Required Required - 181 Provided - 38 Existing + 143 Planted = 181 Note: 100% of proposed plantings are native. Total Shrubs Required Required - 2,329 7.09.03.E.2.1- Planting Under Utility Lines Provided - Z329 Note: Small trees are being utilized to meet code section 7.09.03.E.2.L No tree shall be planted where it could, at mature height, conflict with overhead power lines. Larger trees (trees with a mature height of thirty (30) feet or more) shall be planted no closer than a horizontal distance of thirty (30) feet from the nearest overhead power line. Medium trees (trees with a mature height between twenty (20)-thirty (30) feet) shall be off -set at least twenty (20) feet horizontally from the nearest overhead power line. Small trees (trees with a mature height of less than twenty (20) feet) shall not be required to meet a minimum off -set, except that no tree, regardless of size shall be planted within five (5) feet of any existing or proposed utility pole, guy wire, pad mounted electrical transformer or other utility transmission/ collection structure or equipment. PCant.L'st QTY SYM SPECIES CANOPY IORNAMENTAL TREES 1 IC* ILEX CASSINE 28 MG-1* MAGNOLIA GRANDIFLORA 4 MG* MAGNOLIA GRANDIFLORA 30 PE* PINUS ELLIOTTI DENSA 13 QL* QUERCUS LAURIFOLIA 63 QV* QUERCUS VIRGINIANA 4 TD* TAXODIUM DISTICHUM PALMS SP* SABAL PALMETTO LARGE SHRUBS / ACCENTS 227 FOS* FORESTIERA SEGREGATA 2,105 MYR* MYRICANTHES FRAGRANS 27 MYR-1* MYRICANTHES FRAGRANS MED. SHRUBS /GROUNDCOVERS/ VINES /SOD SOD PASPALUM NOTATUM * = FLORIDA NATIVE COMMON NAME/DESCRIPTION SIZE SPACING REMARKS DROUGHT TOLERANCE DAHOON HOLLY LITTLE GEM MAGNOLIA D.D. BLANCHARD MAGNOLIA SOUTH FLORIDA SLASH PINE LAUREL OAK LIVE OAK BALD CYPRESS i.9.1:7:11911kyj FLORIDA PRIVET SIMPSON STOPPER SIMPSON STOPPER BAHIA SOD GeneraCJVotes 12' x 5', 2.5" D.B.H. A.S. FULL CANOPY, 4' C.T. MIN. HIGH 12' x 5', 2.5" D.B.H. A.S. FULL CANOPY, 4' C.T. MIN. HIGH 12' x 5', 2.5" D.B.H. A.S. FULL CANOPY, 4' C.T. MIN. HIGH 12' x 5', 2.5" D.B.H. A.S. FULL CANOPY, 4' C.T. MIN. HIGH 12' x 5', 2.5" D.B.H. A.S. FULL CANOPY, 4' C.T. MIN. HIGH 12' x 5', 2.5" D.B.H. A.S. FULL CANOPY, 4' C.T. MIN. HIGH 12' x 5', 2.5" D.B.H. A.S. FULL CANOPY, 4' C.T. MIN. HIGH EXISTING A.S. RELOCATED FROM ON SITE HIGH #3, 2' x 2' 2' O.C. FULL & THICK HIGH #3, 2' x 2' Z O.C. FULL & THICK HIGH #7, 4' x 2' 2' O.C. FULL & THICK HIGH SEE SPECS HIGH 1. No plant substitutions can be made without St. Lucie County's approval. 2. All required landscape improvements must be inspected and approved by St. Lucie County prior to the issuance of a Certificate of Occupancy. 3. Any existing landscaping, sod, or irrigation damaged or destroyed during the construction shall be replaced prior to the final inspection. 4. All prohibited, exotic and invasive species shall be removed from the entire site prior to issuance of certificate of occupancy. 5. Planting adjacent to fire hydrants is to have a minimum clear radius of 7.5' as required by the NFPA Uniform Fire Code Florida Edition 18.3.4.1 Hydrants. All fire hydrants and fire check valves shall have a minimum of 7.5' from the front and sides with 4' from the rear to all landscape material per the Florida Fire Prevention Code. PROPOSED 10. LANDS CAPE BUFFER i BUFFER 4' BARBED WIRE FENCE CORNER 53.9' N I 41.2' N -\ T.O.B. GATE POST GATE POST 4' BARBED WIDE FENCE ® DCH 89°50'S9"W 7268'N4I , DITCH ® - - - L - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -------------_--------------_-- I - - - _ - - - - - - - - - - - - - - - - T.O.B. - - - - ° PROPOSED DITCH DITCH ll 9'53"F 10' LANDSCAPE I I 9644 BUFFER I 4' BAj�BED WIRE FENCE iJER 1441 ,2GTE I II ANY NOTE: I NOTE: X I TURNAROUND AEXISTING NATIVE TREES THAT CAN REMAIN IN THE � ANY EXISTING NATIVE TREES THAT CAN REMAIN IN THE I I I PERIMETER BUFFERS SHALL REMAIN AND BE CREDITED I PERIMETER BUFFERS SHALL REMAIN AND BE CREDITED I I TOWARDS REQUIRED PERIMETER BUFFER TREES. 4 BARBED WIRE FENCE TOWARDS REQUIRED PERIMETER BUFFER TREES. I 66'S EXISTING TREES TO REMAIN SHALL BE REVIEWED AND THE EXISTING TREES TO REMAIN SHALL BE REVIEWED AND THE AFF,TEEFE"ND9°2D58"F PROPER CREDIT APPLIED TOWARDS THE REQUIRED TREES SHALL BE GIVEN, THUS REQUIRING LESS PLANTED TREES I 76.84SHALL BE GIVEN, THUS REQUIRING LESS PLANTED TREES BASED ON THE CURRENT CODE REQUIREMENTS. BASED ON THE CURRENT CODE REQUIREMENTS. NOTE: NOTE: X l THE PERIMETER BUFFER HEDGES SHALL BE GROWN AND THE PERIMETER BUFFER HEDGES SHALL BE GROWN AND I I I ^^^ MAINTAINED TO A MINIMUM HEIGHT OF 48". PROPOSED GRAVEL AREA � - MAINTAINED TOAMINIMUM HEIGHT OF 48". I ® LUMBER RES N90°D9'DD"W z I (33033044040 SF.) Ii II I 921 ll N39°09'49'W ��' Z � 41141411141441 PHASE 1 ca 0.40' 99 - PDS ORDER 2020-042 X Oj LESS & EXCEPT al ' I O.R.B 4455, P.G 1954 01 II I ll I I X ll , l I I I I I ll I PARCEL ID: 1336-240-0000-000-3 PHASE - (VACANT) LAND USE:) I I I II I X II I I I PHASE LINE I I I II I X X I I I I ll I ^� I I a II I N89°50'S9"W 432.93' l NOT LOCATED NOT LOCATED AS PART OF THIS UII ll I I X ll I I I . to 0 LuXz Ili U) cc �P AREA LL > 0 M W llw x LL a Ili Z i X ca ZJIL` I I H __ NOTE: ' --------------------- V �U ANY EXISTING NATIVE TREES -------___ -- --____ aIIW I THAT CAN REMAIN IN THE + ----®----------- z eta PERIMETER BUFFERS SHALL - - - _ - - - - - _ _ _ REMAIN AND BE CREDITED -------_ DITCH -------_ 1- 0 I Cl) TOWARDS REQUIRED PERIMETER ---------- ___ ---- I d BUFFER TREES. EXISTING TREES �� ,-------- ____ 1 X Q' _ TO REMAIN SHALL BE REVIEWED ----- IO in AND THE PROPER CREDIT APPLIED TOWARDS THE ��� PARCEL ID: 13W-240-0000-000-3 Ida REQUIRED TREES SHALL BE (VACANT) I LAND USE: NC Ili I O GIVEN, THUS REQUIRING LESS - I I I F- PLANTED TREES BASED ON THE I CURRENT CODE REQUIREMENTS l I M NOTE: X Z THE PERIMETER BUFFER WOOD A /o O D HEDGES SHALL BE GROWN AND Vk I PHASE 11 MAINTAINED AMINIMUM ROCK POND HEIGHT OF 48". SHED V (EMPTY) I It ; U) O I X II I PHASE 11 � 1 W I �I W !I it �I 0 BARBED WIRE FENCE CORNER Z I � , VACANT 30.1'N, 234'E X m / Z GIRT ROAD <_ LL O I� W GRASS D_ I LL o AREA ABANDONED WELL I LLI ll I Z 1580 X l l l I �0' J I H n o� POWER POLE ll J >w > I PHASE I I GUYANCHORm� X 1 1 I I 4" VALVE AND PVC PIPE t I FUTURE DEVELOPMENT 1 I FUTURE ACCESS GATE I BARBED WIRE FENCE � I t GATE POST 14.5' S DIRT ROAD tl I - I GATE POST 15.0' S T.O.B. N8/.'.'1122032' APPROXIMATE SHORELINE X X/ X Y „ I �X X X X X X X�X DI Mp ` � I -- Lin TrID'------------- --------- ------ -- --- �- ---------- ---- ----- Landscape Spect' fications 1. All tree and plant material to be Florida No. 1 or better, as classified in "Grades and Standards for Nursery Plants", Part 1 and Part II, State of Florida, Dept. of Agriculture, Tallahassee. All plants not listed in "Grades and Standards for Nursery Plants" shall conform to a Florida No. 1 as to: (1) health and vitality, (2) condition of foliage, (3) root system, (4) freedom from pest or mechanical damage, (5) heavily branched and densely foliated according to the accepted normal shape of the species. 2. Undersizing or substitution of one species or cultivar for another species is a breach of contract and will be "Rejected" at the time of final landscape inspection unless approved by Landscape Architect. 3. Project Warranty: All plant material shall be warranted for a period of one (1) year after date of substantial completion against defects, including death and unsatisfactory growth, except for defects resulting from abuse or damage by others or unusual phenomena or incidents which are beyond the contractor's control. 4. Any and all conditions which the contractor feels will be detrimental to the success of the planting shall be brought to the owner or representative's attention. 5. The contractor shall verify the location of underground utilities prior to commencing work on any project area. 6. Mulch planting areas with 3" layer of Melaleuca, Eucalyptus, or Enviromulch. Cypress Mulch is NOT ACCEPTABLE. Planting beds to receive mulch throughout entire bed area. 7. All plants to be set to ultimate grade. No filling will be permitted around trunks or stems. Mulch to be kept a minimum of 2" away from trunks and stems. 8. Planting trees and shrubs: Excavate hole per planting detail. When plant is set, place additional backfill consisting of a 50% mixture of Peat humus and natural soil around the base and sides of ball, and work each layer to settle backfill and eliminate voids and air pockets. When excavation is approximately 2/3 full, water thoroughly before placing remainder of backfill. Water again after placing final layer of backfill and before installing mulch. 9. Guy and stake trees in 3 directions with galvanized wire, through flexible hose chafing guards, with wooden stake anchors immediately after planting. (See Detail) 10. Trees and shrubs shall be fertilized with a complete natural organic fertilizer with a ratio of approximately 3:0:2 or 3:0:3 (e.g. one labeled 12-0-8). Similar analysis such as 16-0-8 (4:0:2) can also be used. Fertilizers that are slow release, controlled release, sulphur coated or with nitrogen as IBDU or ureaformaldehyde have extended release period. Thirty to fifty percent of the nitrogen should be water insoluble or slow release. Palms should receive a complete granular fertilizer formulated for palms ("Palm Special") at a rate of 5 to 8 lbs. per palm. Agriform 20-0-5 twenty-one gram planting tablets may be substituted for granular fertilizer. If utilized, the following rates shall be utilized: Position plant in hole. Backfill halfway up the rootball. Place tablet(s) beside rootball about 1" from root tips. Do not place tablet(s) in bottom of hole. 1 Gallon 1 Tablet 3 Gallon 2 Tablets 25 Gallon & B&B Trees 2 per l" caliper 11. All planting areas to be irrigated to provide 100%O coverage. Shop drawings to be submitted by the irrigation contractor for approval prior to installation. 12. Maintain trees, shrubs, and other plants by watering, cultivating, and weeding as required for healthy growth. Restore planting saucers and mulch. Tighten and repair stake and guying and reset trees and shrubs to proper grade or vertical position as required. Spray as necessary to keep trees and shrubs free of insects and disease. The contractor shall begin maintenance immediately after planting and shall continue maintenance through final acceptance when Certificate of Occupancy is issued to the General Contractor by County and project is released by the General Contractor to Client. 13. Prune trees and shrubs only to remove damaged branches as directed by the Landscape Architect. 14. Planting Lawns: Provide clean, strongly rooted, uniformly sized strips of Stenotaphrom secundatus Floritam (unless otherwise noted), machine stripped not more than 24 hours prior to laying. Grade and roll prepared lawn surface. Water thoroughly but not to create muddy soil conditions. Lay sod strips with tight joints, roll or tamp lightly, and water thoroughly. 15. Maintain positive drainage, no planting is to block drainage. 16. Drainage Testing Prior to planting of trees, palms, and specimen material, each planting pit shall be tested in the following manner to verify adequate drainage. A) Dig each planting pit to the minimum specified size. B) Fill the planting pit with (12") twelve inches of water. If the water level in the planting pit drops (4") four or more inches within (4) four hours, the drainage is sufficient and a drainage channel is not required. If the water level drops less than (4") four inches within the (4) four hour period, then a drainage channel is required. C) When a drainage channel is required, the drainage channel must extend down through the non porous soil and into porous soil. (See Drainage Testing Detail) D) Discard all material removed from the drainage channel. E) When backfilling the planting pit, add course gravel to the drainage channel. Also, care must be taken to keep the consistency of the soil mix the same throughout the planting pit. NOTES: 1. Contractor to include drainage testing for all trees and palms in bid. If drainage is inadequate, the soil specification in item #8 above shall be revised for site conditions. Contractor shall notify the Owner and Landscape Architect of poor drainage conditions in writing and written direction will be provided to the contractor of appropriate soil mixture specification to be used. 2. All fertilizers shall meet the St. Lucie County fertilizer ordinance. ELECTRONIC SIGNATURE AND SEAL Registered Landscape Architect Jeffrey WSomitth, RLA Digitally signed by Jeffrey W. Smith, RLAIan ca e Prepared, Reviewed & Supervised By: A Conceptual Ocean nulevar lSu Date. 2021 .09.24 12:50:03-04�00� 900 East Ocean Boulevard, Suite 130d Stuart, Florida 34994 (772)344-2340 LC:26000198 Plan North Scole: I" = 100' 0 50' 100' 200' Conteitual Demo ( r nc. Go , Landscape ArdtitPctnrP - Site Planning 900 East Ocean Boulevard, Suite 130d Stuart, Florida 34994 (772) 344-2340 LC: 26000198 C/) O O Q) J County Project Number: Jeffrey W Smitb, RLA Florida Registration Number: LA 0001635 Job No. 21-0108 Drawn By JWS Submittal Dates 4-27-2021 9-17-2021 Revision Dates Comments #1 9-17-2021 These drawings are the property of the landscape architect and are not to be used for other projects except by written permission from the landscape architect. Report any discrepancies immediately to the landscape architect. L-7 6 Sheet of Ec, 74' I I I O I � N I I LO I }- CD I Q I I � � O o� I I I = O O O O I m I W I 0 _X X X X X X���X M I � r) W W r) Z Q ry 00 >Q � 00 J O U W n U) GATE ReCocate Existing Patm Saba( to remain PaCms (7yp.) 0 I %< EXISTING ( I 6' CHAIN LINK FENCE j I � I = I W I0-10 I I .I er I I 14 1 T rC U UUMD .�lll<1��"im / 9a� 370 -,,aea, PaCms QV 20 Q /6 --- ----------- ffn PROPOSED DUMPSTER MLo — j 0 I f�• \1 I � / � YR- 27 227I I I \ Qv I I d- MG I I � M 4 INI :I PROPOSED EXISTING 10 LANDSCAPE l C) ELEC. PANEL BUFFER z I \ : L EXISTING ° A/C PAD � o EXISTING i - PAVERS PATH 50' J�I I I I / I :V EXISTING I CD OFFICE o 3 / BUILDING B 5,000 S.F. ( 1 YR I I 370 I 3 1� 50' + + V \ x 13 1 HYD EXISTING GAS TANK 12'X55' gigmi r I � • TYPE "D" CURB 1 7r2e to be'—J ` removed ReCoeate Tree to (7ypJ Saba( remain PaCms (7ypJ (PROPOSED PARKING AREA) NOTE: SOME OF THE TREES SHOWN TO BE REMOVED DO NOT MEET _THE _REQUIREMENTS FOR _MITIGATION _AND MAY NOT AP -I IPEAR ON THE MITIGATION PLANS I EXISTING EXISTING CATCH BASIN LUMBER (TYP) ,STORAGE AREA, 1 I 250' NOTE: ANY EXISTING NATIVE TREES THAT CAN REMAIN IN THE PERIMETER BUFFERS SHALL REMAIN AND BE CREDITED TOWARDS REQUIRED PERIMETER BUFFER TREES. EXISTING TREES TO REMAIN SHALL BE REVIEWED AND THE PROPER CREDIT APPLIED TOWARDS THE REQUIRED TREES SHALL BE GIVEN, THUS REQUIRING LESS PLANTED TREES BASED ON THE CURRENT CODE REQUIREMENTS. NOTE: THE PERIMETER BUFFER HEDGES SHALL ,BE GROWN AND MAINTAINED TO A MINIMUM HEIGHT OF 48. N N Cn � EXISTING 1-STORY MANUFACTURING BUILDING A 2590 KINGS HIGHWAY FT. PIERCE, FLORIDA 63,750 S.F. EXISTING A/C PAD EXISTING CONIC SLAB 250' FM BARBED WIRE FENCE N89050'59"W t- '— v■ r � ReCocate —Y Saba( Palms i PROPOSED i f-NnrNIMIf+ -7f-%nir 1130.59' EXISTING 32'X40' COVERED AWNING 1,280 S.F. PROPOSED PROPOSED 5' CONCRETE 10' LANDSCAPE ADJACENT PARCELSIDEWALK BUFFER PNC:1336-231-0002-000-9 ,ONWER:PHILIP C GATES Landscape Plan North Scale: I " = 30' 0 15' 30' 60' Con_ ce tua� p esz LanrtscaprArd ital re - Si1c Pl nning 900 East Ocean Boulevard, Suite 130d Stuart, Florida 34994 (772) 344-2340 LC: 26000198 ■ V i 0 0 Q) u .Q) J rr� vJ County Project Number: Jeffrey W Smitb, RTA Florida Registration Number: LA 0001635 Job No. 21-0108 Drawn By JWS Submittal Dates 4-27-2021 9-17-2021 Revision Dates Comments #1 9-17-2021 These drawings are the property of the landscape architect and are not to be used for other projects except by written permission from the landscape architect. Report any discrepancies immediately to the landscape architect. L-2 6 Sheet of landscape Plan North Scole: 7 " = 30' 15' 30' 60' o ce tz�a� Goo , nc. p LandscapeArcfiitecture - Site Planning 900 East Ocean Boulevard, Suite 130d Stuart, Florida 34994 (772) 344-2340 LC: 26000198 CO�+ ■ V i _O U O yr V J CIO C/0 County Project Number: Jeffrey W Smitb, RLA Florida Registration Number.• LA 0001635 Job No. 21-0108 Drawn By JWS Submittal Dates 4-27-2021 9-17-2021 Revision Dates Comments #1 9-17-2021 These drawings are the property of the landscape architect and are not to be used for other projects except by written permission from the landscape architect. Report any discrepancies immediately to the landscape architect. L-3 6 Sheet of � � I ----___—_---/ I 11 II II II I� x III I I I I III I, I II II II X 4' BA�BED 14.4';, 26 II II X II II II II II II II II X l II II II II I II I I II X II I I I I I I I I I I I I I I I X l I I I I I I I j I I I I I I X II I I I I I I I I I I I I I I I I X I I I I I ! I I j I I I I X I I LL ( I I I I M I I W I I I X I I I I I OI I I I I I I X n I I.i I I I I I OII I I I I I I X I I I I I I I I I I I I I I X I I I I I I I I j I I I I I I x I I I I I I I I I I I I I I I I I X I I I I I I I I I I I I I I I I X I I I I I I I I I I I I I X I I I I I I I I I I I I I I I I X ILL I I ILL ILL I I I I I I I I I I I X I I I ILL I I I I I I I I I I I I I X I I I I I I - I I I I I I I X II II II I II II II X II II II II II II II II x I I II II I II I I I I I I I I x II I +I U I x iz II� II I 0 II I I x II I� I I W 'o II U z I it Z X lz I I W IlO r II WIRE FENCE 3' E I I I I I I I I I I I I II I I II I I I I I I C R' NER I I I II I I I I I I I I I I I II I I I II I I I I I I I I I I I II I I II I I I I I I I I I I I I I� I I I' I I I I I I I I I I II III I I I I I I II I I I I I I I I I II I I I II I I I I I I I I I I I I II I I II I I I I I I I I I I I I I II I I II I I I I I I I I I I I I II I I I I' I I I I I I Q W Landscape Plan North Scole: I ' = 30' 7 15' 30' 60' once tua� p GandwtaprArd ital re - Si1c Pl nning 900 East Ocean Boulevard, Suite 130d Stuart, Florida 34994 (772) 344-2340 LC: 26000198 col (U ■ V i O LL O V 0 � v J 00 County Project Number: Jeffrey W Smitb, RTA Florida Registration Number: LA 0001635 Job No. 21-0108 Drawn By JWS Submittal Dates 4-27-2021 9-17-2021 Revision Dates Comments #1 9-17-2021 These drawings are the property of the landscape architect and are not to be used for other projects except by written permission from the landscape architect. Report any discrepancies immediately to the landscape architect. L-4 6 Sheet of T PROPERTY LINE � �15 6 1585 \N X / 1184 21 i '1_1�15 3 0 ` NOTE: ANY EXISTING NATIVE TREES THAT CAN REMAIN IN THE PERIMETER BUFFERS SHALL REMAIN AND BE CREDITED TOWARDS REQUIRED PERIMETER 15 2 BUFFER TREES. EXISTING TREES �--/ TO REMAIN SHALL BE REVIEWED AND THE PROPER CREDIT APPLIED TOWARDS THE REQUIRED TREES SHALL BE GIVEN, THUS REQUIRING LESS PLANTED TREES BASED ON THE CURRENT CODE REQUIREMENTS NOTE: V THE PERIMETER BUFFER HEDGES SHALL BE GROWN AND MAINTAINED TO A MINIMUM HEIGHT OF 4811 . �1581 21 )l79 ,�1 �580 / } / / / + PHASE 11 / A - IX w00E SHED �IO 0 0 02 f 0 f 14` 7 17,717 . D I RT ROAD f I f I f I + Z CD CD0 CD N I 04 O O Cn I CO m FUTURE DEVELOPMENT FUTURE ACCESS I PHASE 11 • \\1m I" v,: , ���1I �y� o \hlo+l- \��il, \S,hi hi i p\ ���nn i( m� •••••E�•••�a••••••••E�.�•�'a••r ���_�•E�•����••••••••E••••jai•••••�•E'!••��•••••i••E�•••4�:a••••••••�a�����•••y�••��E������••••••••�!••••:�••••••••• GATE POST 15.0' S X X X Landscape Details - Spread - Qt ,m v (5) 2" x 4" x 18" woodbattens to be evenly spaced around trunk of tree..A minimum of (5) five wraps of burlap are to be placed under the battens to prevent marring or damage to the trunk. The height of the battens shaCCbe COcatedin reCation to the height of the tree for adequate bracing. No batten is to be nailed to the tree. Battens are to be bandedwith a minimum of (2) two 314 " high carbon steel bands. alinimum of (3) three 4" x 4" •woodbraces evenly spaced around tree to be toe nailed to woodbattens. -AttachfCorescent safety flags a min. Of 12" in Length to each woodbrace. Planting depth shaClbe to% Cess than the height of the root baCCfrom the Flair Root. Diameter of hole to be three times the size of root baClminimum. Plant top of root ball at 2" minimum above the finished grade elevation. Form a mulch berm with 3" minimum depth andno more than 4" high_ Mulch to edge of rootbaCC but leave top of rootbaCCexposed Remove burlap or steeCcage from top 1/3 of root balf(If applicable). Finished Grade Drive 2" x 4" x 24" woodstake a min. Of 3" betbw grade. 3 times diameter BackfiCCaroundroot baCCaccording to I of rootbad (Min.) specifications. Water and tamp to remove Notes: air pockets. 1..ACCpruning shalCbe compltedat the direction of the landscape .Architect. 2. No nails shallbe driven into tree Large free PCantln� Detail (5" Caliper or Greater) Not to Scale Spread o v d Q Place 112" diameter black rubber hose on aCCguy wires at aCCpoints of contact with tree. Place 3 galvanizedsteet'doubte strand#I2 gauge twisted guy wires with one galvanized turnbuckle per guy wire spacedat equaCdistance aroundtree. .Attach fCorescent safety flags a min. of i2" in length to each guy wire. Planting depth shaCCbe io% Cess than the height of the root baCCfrom the Flair Root. Diameter of hole to be three times the size of root baCCminimum. Plant top of root baClat 2" minimum above the finished grade elevation. Form a mulch berm with 3"minimum depth andno more than 4" high. Mulch to edge of rootbaC� but leave top of rootbaCC exposed Remove burlap or steeCcage from top 1/3 of root balC(If applicable). Finished Grade Drive 2"x4"x24"woodstake amin- Of3" � I I I I I I —I 11=1 11=1 11=1 11=1 11=1 11=1 11= ' bet6w grade. _ 3 times diameter - I BackfiCCaroundroot baCCaccording to r of rootball (Min.) , specifications. "Water and tamp to remove Notes: air pockets. 1. Adpruning shatibe completedat the direction of the landscape .Architect. 2. No nails shalCbe driven into tree Ire e Planting D e tail Not to Scale Spread Place 1/2" diameter black rubber Grose on aCCguy wires at aCCpoints of contact with tree. Place 3 galvanizedsteeldoubCe strand#12 gauge twisted guy wires with one galvanized turnbuckle per guy wire spacedat equaCdistance aroundtree. .Attach fCorescent safety flags a min. of i2" in Length to each guy wire. Planting depth shaCCbe io% Cess than the height of the root baCCfrom the Flair Root. Diameter of hole to be three times the size of root baCCminimum. Plant top of root baCCat 2" minimum above the finished grade elevation. Form a mulch berm with 3" minimum depth andno more than 4" high. 9vlutch to edge of rootbaCC but leave top of rootbaCC exposed Remove burlap or steelcage from top 1/3 of root balC(If applicable). Finished Grade Drive 2" x 4" x 24" woodstake a min. of 3" bet6w grade. 3 times diameter BackfiCCaroundroot baCCaccording to of root6aCC(Min.) specifications. "Water and tamp to remove Notes: air pockets. i. ACCpruning shatibe completedat the direction of the Landscape .Architect. 2. No nails shalCbe driven into tree _Multi -Trunk Tree Planting Detail Not to Scale Prune & tie aCCfronds together with degradable twine. There is to be a minimum of 6-8 fronds (unless notedbeCow). (5) 2" x 4" x 18" woodbattens to be evenly spacedaroundtrunk ofpafm..Aminimum of(5)five wraps of burlap are to be pCaced under the battens to prevent marring or damage to the trunk. The height of the battens shaCCbe COcatedin reCation to the height of the palm for adequate bracing. No batten is to be nailed to the palm. Battens are to be bandedwith a minimum of (2) two 314" high carbon steeCbands. Minimum of (3) three 4" x 4" woodbraces evenly spacedaroundpalm to be toe nailed to woodbattens. .Attach fCorescent safety flags a minimum of i2" in length to each brace Planting depth shaCCbe io% Cess than the height of the root gaff Diameter of hole to be two times the size of root baCCminimum. Plant top of root baCCat 2" minimum above the finished grade elevation. Form a mulch berm with 3"minimum depth andno more than 4" high. -'Mulch to edge of rootbaC� but leave top of rootbaCC exposed BackfiCCaroundroot baCCaccording to specifications. Water and tamp to remove airpockets. Finished Grade 2" x 4" x 24" woodstake to be 2" below grade. Size of rootbaffwiCCbe inproportion to type Notes: andsize ofpalm, in accordance with ,. Hurricane cur sa6aCPaCms are acceptable. Florida Grades andStandards for Nursery 2. ACCti9ashingtonia andSabat'Paims to be booted unless otherwise notedinpCant list. Plants Part I & II Latest Edition. 3. Palms with burnedor marredtrunks wilCnot be accepted PaCm Planting Detail Not to Scale Place 1/2" diameter black rubber hose on aCC guy wires at aCCpoints of contact with tree. Place 3 galvanizedsteeCdouble strand#12 gauge twisted guy wires with one galvanized turnbuckle per guy wire spacedat equal distance aroundtree above the first lateral branch. .Attach fCorescent safety flags a min. of i2" in Length to each guy wire. Tree Trunk �u•y 'Wire .Attachment Detail Not to Scale Pl Staking Detail Not to Scale Dra 2" x 4" x 24"Long stake Guy wire or woodbracing Tree Pit Root BaCC Tree Trunk 12" depth of water Finishedgrade Non porous soil Porous soil 6" diameter drainage channel Note: Refer to planting details for sue of pCantingpit Rootbafl Finishedgrade Planting mix •:1`6 }. w�i• .. A- a "J.�• 4 ..: ;51e $'' Non orous soil Porous soil 6" diameter drainage channeffiCCed with course gravel DiscardmateriaC Plantedpit with inadequate drainage removedfrom drainage channel Drainage Testing Detail Not to Scale 3" minimum depth of mulch. Xeep mulch away from base of stem (See specifications) Planting depth shaClequafdepth of root ball Diameter of hole to be twice the size of root ball For root balls Carger than Yin diameter, the hole shoufdbe 2' wider than root baCCon aliCsides. Plant top of root gaff at same elevation as finished grade. III -III I E `� Finished Grade Form 3" continuous earthen rim around y1anting hole. =11111= I=III "- BackfiCCaroundroot baCCaccording to Notes: specifications. Water and tamp to remove i..AlCpruning shallbe completedat the direction of the Landscape .Architect. air pOCketS. 2. Remove any container from aroundrootball 3. PCanr as hedge row with O.0 (on center) Place root ball at bottom of undisturbed spacing as specified in plant list, or with subgrade of planting pit. triangular spacing as a mass. Shrub Detail Not to Scale Section O.C. Spacing �/ Plan 1�round-Cover Detail Not to Scale landscape Plan See Plant List for O.C. (on center) spacing 3" minimum depth of mulch. Xeep mulch away from base of stem (See specifications) Planting depth shaClequafdepth of root ball Diameter of hoCe to be twice the size of root ball Plant top of root baCCat same elevation as finished grade. Finished Grade BackfiCCaroundroot baCCaccording to specifications. Water and tamp to remove air pockets. Place root baCCat bottom of undisturbed subgrade of planting pit. 3" minimum depth of mulch. Xeep mulch away from base of stem (See specifications) .Alternate spacing ofytants to insure proper coverage of groundcover (Triangulate planting) Edge ofpCanting bed North) Scale: 1 " = 30' 0 75' 30' 60' o ce tua� S Gro nc. LandscapeAychile(6ufe -Site X,anniny 900 East Ocean Boulevard, Suite 130d Stuart, Florida 34994 (772) 344-2340 LC: 26000198 ■ V i C) W CJ J ■ County Project Number.' Jeffrey W Smitb, RLA Florida Registration Number LA 0001635 Job No. 21-0108 Drawn By JWS Submittal Dates 4-27-2021 9-17-2021 Revision Dates Comments #1 9-17-2021 These drawings are the property of the landscape architect and are not to be used for other projects except by written permission from the landscape architect. Report any discrepancies immediately to the landscape architect. L-5 6 Sheet of LUMBER 1 LUMBER �ptcac5o'Secttobn -fake fittoraCPCan STORAGE AREA STORAGE AREA Not to scale Edge of water N CAF�A7 SPB JUE CRA II -rT-� 7 15 A 15 7 7 Littoral Planting i EXISTING PUMP HOUSE Z,L.pCandBuffer Section PCantlist TOTAL QTY QTY/SECTION SPECIES COMMON NAME SIZE SPACING upland Planting 14 1 ACER RUBRUM RED MAPLE 12' x 6, 2.5" CAL. A.S. 15 1 TAXODIUM DISTICHUM BALD CYPRESS 12'x 6, 2.5" CAL. A.S. 174 6 CALLICARPA AMERICANA BEAUTY BERRY #1, 12" x 12" 36" O.C. 145 5 CANNA FLACCID GOLDEN CANNA #1, 12" x 12" 36" O.C. 406 14 MUHLENBERGIA CAPILARIS MUHLEY GRASS #1, 12" x 12" 36" O.C. 348 12 MYRICA CERIFERA WAX MYRTLE #1, 12" x 12" 36" O.C. 290 10 OSMUNDA CINNAMOMEA CINNAMON FERN #1, 12" x 12" 36" O.C. 145 5 SERENOA REPENS SAW PALMETTO #3, 12" x 12" 36" O.C. 725 25 SPARTINA BAKERI SAND CORDGRASS #1, 12" x 12" 36" O.C. 1,450 L.F. of Shoreline / 50' Sections = 29 Sections Notes: 1. All plant materials shall be planted and maintained in a natural arrangement. 2. The Upland Buffer shall consist of native vegetation only and shall be maintained permanently as part of the surface water management system. 3. The Upland Buffer vegetation shall be planted such that no less than 50 percent of the total shoreline is buffered by a minimum width of 10 feet of upland buffer. Requirements: 6.2.3.F. - Required Buffering - A buffer zone of native upland edge (i.e., transitional) vegetation shall be provided and maintained around isolated wetlands covered by this Section which are constructed or preserved on new development sites. The buffer zone may consist of preserved or planted vegetation but shall include canopy, understory, and ground cover of native species only. The edge habitat shall begin at the upland limit of any wetland or deepwater habitat. As a minimum, ten (10) square feet of such buffer shall be provided for each linear foot of wetland or deepwater habitat perimeter that lies adjacent to uplands. This upland edge habitat shall be located such that no less than fifty percent (50%) of the total shoreline is buffered by a minimum width of ten (10) feet of upland habitat. The upland buffer requirement does not apply to drainage canals or stormwater conveyance systems requiring periodic maintenance. TyytcaC50'UyCandJ3uffer Section Not to Scale (5) Golden Canna (25) Sand Cordgrass (5) Saw Palmetto (12) Wax Myrtle PROPERTY LINE ;�; W. • W W W 411 ItttoraCZone PCant 10' Littoral Shelf J It's t Stiore Line Length of Punting = 1,450' = 29 Sections TOTAL QTY QTY/SECTION SYM SPECIES COMMON NAME/DESCRIPTION SIZE SPACING REMARKS 203 7 CAF* CANNA FLACCIDA GOLDEN CANNA BARE ROOT 3' O.C. SHORELINE - 3" DEPTH 203 7 CRA* CRINUM AMERICANUM SWAMP LILY BARE ROOT 3' O.C. SHORELINE - 3" DEPTH 406 14 ELS* ELEOCARIS INTERSTINCTA SPIKERUSH BARE ROOT 3' O.C. 6-18" DEPTH, CLEAN, WEED FREE 203 7 IRV* IRIS VIRGINICA SOUTHERN BLUE FLAG IRIS BARE ROOT 3' O.C. SHORELINE - 3" DEPTH 435 15 JUE* JUNCUS EFFUSUS SOFTRUSH BARE ROOT 3' O.C. SHORELINE - 3" DEPTH 160 10 NYO* NYMPHAEA ODORATA FRAGRANT WATERLILY BARE ROOT 7' O.C. 24" ROOT, 2-3' DEPTH, CLEAN, WEED FREE 406 14 SAS* SAGITTARIA SPP. ARROWHEAD BARE ROOT T O.C. 24" HT, 6"-2' DEPTH, CLEAN, WEED FREE 435 15 SPB* SPARTINA BAKERI SAND CORDGRASS 4" LINER 2' O.C. SHORELINE - 6" DEPTH 406 14 POC* PONTEDERIA CORDATA PICKEREL WEED BARE ROOT 3' O.C. 24" HT, 6"-2' DEPTH, CLEAN, WEED FREE * = FLORIDA NATIVE 100% Native Plantings Pl6antin,q Detail Growng tips extend above water 'ontroC EC. Tamp roots firmly into native soil Native soil Genera,CXotes 1. All plant materials shall be planted and maintained in a natural arrangement. 2. The littoral zone shall consist of native vegetation only and shall be maintained permanently as part of the surface water management system. 3. Lake management plans shall comply with St. Lucie County & South Florida Water Management District rules and shall be subject to approval by the St. Lucie County. landscape Plan North Scale: I " = 30' 0 15' 30' 60' Conte tua� p De Gyou , nc. p Gatldstvpe ArdtileGlnye - Site XannEng 900 East Ocean Boulevard, Suite 130d Stuart, Florida 34994 (772) 344-2340 LC: 26000198 C/) ■ V i 0 � v a� J rr� vJ C/0 County Project Number: Jeffrey W Smith, RLA Florida Registration Number: LA 0001635 Job No. 21-0108 Drawn By JWS Submittal Dates 4-27-2021 9-17-2021 Revision Dates Comments #1 9-17-2021 These drawings are the property of the landscape architect and are not to be used for other projects except by written permission from the landscape architect. Report any discrepancies immediately to the landscape architect. L-6 6 Sheet of