Loading...
HomeMy WebLinkAboutReview of Boundary Survey for Southern Truss Project Public works ENGINEERING DIVISION SURVEY REVIEW COMMITTEE June 10, 2021 Project: Southern Truss Subject: SURVEY REVIEW To: David Hays, Grant Chambers From: John Wilbon, PLS SLC-Engineering Division- Survey Section All comments are based on the current Standards of Practice, established by the Board of Professional Surveyors and Mappers, Chapter 5J-17.050 thru 5J-17.053 , Florida Administrative Code, pursuant to current Section 472.027, Florida Statutes. SURVEY: 1) Please include Vertical accuracy statement based on expected use per 5J-17.051 (2) (a) in the Notes. 2) Please list the Reference Benchmark for the Survey 3) Please add missing dimensions for less and except parcel along King’s Highway 4) Please consider a re-write of Note # 6 “The Bearings shown are referenced to Grid North, based on the Florida State Plane Coordinate System. East zone, using the North American Datum of 1983 (yr. of adjustment). The Basis of Bearings for this Survey is….. 5) Please add text for P.O.C. (bearing & distance) and text for P.O.B. on the Less and Except parcel at the Northwest corner of this Survey 6) Please add fence ties where appropriate on the Survey 7) Please correct scrivener’s error in a distance on the fifth line of the description for parcel on Kings Highway. 8) Please check the scale of the drawing, it is not 1”=30’ 9) Please check text for Sectional descriptions on the North Line of the Survey. Please provide a written response to all comments John B. Wilbon Jr., Assitant County Surveyor 2300 Virginia Avenue Ft. Pierce, Fl. 34982-5652 wilbonj@stlucieco.org (772) 462-2587