HomeMy WebLinkAboutReview of Boundary Survey for Southern Truss Project
Public works
ENGINEERING DIVISION
SURVEY REVIEW
COMMITTEE
June 10, 2021
Project: Southern Truss
Subject: SURVEY REVIEW
To: David Hays, Grant Chambers
From: John Wilbon, PLS
SLC-Engineering Division- Survey Section
All comments are based on the current Standards of Practice, established by the Board of
Professional Surveyors and Mappers, Chapter 5J-17.050 thru 5J-17.053 , Florida Administrative
Code, pursuant to current Section 472.027, Florida Statutes.
SURVEY:
1) Please include Vertical accuracy statement based on expected use per 5J-17.051 (2) (a)
in the Notes.
2) Please list the Reference Benchmark for the Survey
3) Please add missing dimensions for less and except parcel along King’s Highway
4) Please consider a re-write of Note # 6 “The Bearings shown are referenced to Grid
North, based on the Florida State Plane Coordinate System. East zone, using the North
American Datum of 1983 (yr. of adjustment). The Basis of Bearings for this Survey is…..
5) Please add text for P.O.C. (bearing & distance) and text for P.O.B. on the Less and Except
parcel at the Northwest corner of this Survey
6) Please add fence ties where appropriate on the Survey
7) Please correct scrivener’s error in a distance on the fifth line of the description for parcel
on Kings Highway.
8) Please check the scale of the drawing, it is not 1”=30’
9) Please check text for Sectional descriptions on the North Line of the Survey.
Please provide a written response to all comments
John B. Wilbon Jr., Assitant County Surveyor
2300 Virginia Avenue
Ft. Pierce, Fl. 34982-5652
wilbonj@stlucieco.org
(772) 462-2587