Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL - MODIFIED BITUMEN1 FLORIDA ORPAPTMONr OF Business & Professional Regulation r�rra BCIs Home i Lag In I User Registration Hot Topic I Submit Surcharge I Stats & Facts Publications Contact Us I BQS Site Map Unks I Search I Florida *ilhProduct Approval q� USER: Public User Produce Approval Menu > Product ar Aoollcatlon Search > Application Llst> Application Detail `S�eyNED FL # FL1654-R22 Application Type Revision �(I. Code Version 2017 Lvch§ coUn Application Status Approved t y Comments Archived I Product Manufacturer POLYGLASS USA Address/Phone/Email 1111 W. Newport Center Drive Deerfield Beach, FL 33442 (954)233-1330 Ext242 malpert@polyglass.com Authorized Signature Maury Alpert malpert@polyglass.com Technical Representative Maury Alpert Address/Phone/Email 1111 W. Newport Center Drive Deerfield Beach, FL 33442 (912) 429-8610 MAlpert@polyglass.com Quality Assurance Representative Arlel Lender Address/Phone/Email 1111 W. Newport Center Drive Deerfield Beach, FL 33442 (954)'233-1230 ALender@polyglass.com Category+ 9 Subcategory �l�do�dlz Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer ❑ Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Robert Nleminen the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date . 09/13/2021 Validated By John W. Knezevich, PE © Validation Checklist - Hardcopy Received Certificate of Independence Ft t 654 R22 COI 2017 01 COI Nieminen.pdf Referenced Standard and Year (of Standard) Standard Year ASTM D6162 2008 ASTM D6163 2008 ASTM P6164 2011 ASTM D6222 2011. ASTM D6509 2009 FM 4470 2012 FM 4474 2011 UL1897 2012 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 09/14/2017 Date Validated 09/15/2017 Date Pending FBC Approval 09/22/2017 Date Approved 12/12/2017 Date Revised 10/08/2018 Summary of Products FL # Model, Number or Name Description fit Polyg ass 58Sland APP�I710 Ified SBS and,APP4 modifiedblEuiflef}xraofysCe glti(inen{Rgof5y5�h7s Limits of Use Installation Instructions Approved for use In HVHZ: No Fit 654 R22 II 2017 09 FINAL Al ER POLYGLASS MODBIT FL1654- R22.Ddf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Robert Nieminen PE-59166 Design Pressure: +N/A/-622.5 Created by Independent Third Party: Yes Other: 1.) The design pressure In this application Evaluation Reports relates to one particular assembly over concrete Fi t 654 R22 AE 2017 09 FINAL ER POLYGLASS MODBIT FL3654- R22.Ddf deck. Refer to the ER Appendix for other systems and deck types. 2.) Refer to ER, Section 5 for other Created by Independent Third Party: Yes Limits of Use. j ea Next i Contact Us :: 2601 Blair Stone Road Tallahassee FL 32399 phone: 850-487-1824 The State of Florida Is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement:: Refund Statement Under Florida law, emall addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic mall to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address It they have one. The emalls provided maybe used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please j provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, F.S., please click hue_. Product Approval Accepts: ®®®FER® I Credit Card Safe •tti% TRINITY I ERD Table Deck Application Type Description Page 1A Wood New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 5 1B-1 Wood New or Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 5-9 18-2 Wood New, Reroof (Tear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 10-11 1C Wood New, Reroof (Tear -Off) or Recover B Mech. Attached Base insulation, Bonded Top Insulation, Bonded Roof Cover 11 1D Wood New, Reroof (Tear -Off) or Recover C Mech. Attached Insulatlon, Bonded Roof Cover 12-13 1E Wood New, Reroof (Tear -Off) or Recover D Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover 14-15 1F-1 Wood New or Reroof (Tear -Off) E Non -Insulated, Mech. Attached Base Sheet (nails), Bonded Roof Cover 16-18 1F-2 Wood New, Reroof (Tear -Off) or Rec e E Non -Insulated, Mech. Attached Base Sheet (screws & plates), Bonded Roof Cover 19-21 ood NOMErliffiSlavviz i[Eiigo (Tea - ff) ao ve - 2A Steel or Structural concrete New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 22-24 2B Steel or Structural concrete New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 25-28 2C Steel or Structural concrete New, Reroof (Tear -Off) or Recover D Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover 29-31 3A Structural concrete New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 32-40 3B Structural concrete New or Reroof (Tear -Off) F Non -Insulated, Bonded Roof Cover 40 4A LWIC New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 41-42 4B LWIC New or Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 43 4C LWIC New or Reroof (Fear -Off) E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 44-46 SA CWF New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 47 5B CWF New, Reroof (Tear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 48 SC CWF New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 49 SD CWF New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 49 SE CWF New, Reroof (Tear -Off) or Recover E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 49 6A Gypsum Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 50-52 6B Gypsum Reroof (Tear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 52 6C Gypsum Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 53 60 Gypsum Reroof (Tear -Off) or Recover E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 53 7A Various Recover A-1 Bonded Insulation, Bonded Roof Cover 54-58 7B Various Recover F Non -Insulated, Bonded Base Sheet, Bonded Roof Cover 58 to the systems outlined herein: The following apply to the systems outlined herein 1. The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 2. Insulation / base sheet fasteners shall be of sufficient length for the following deck engagement: ➢ Wood: Minimum 0.75-Inch penetration. ➢ Steel: Minimum 0.75-Inch penetration and engage the top flute of the steel deck. ➢ Structural concrete: Minimum 1-Inch embedment Into pilot hole in accordance with fastener manufacturer's published installation instructions. — - 3 Unless otherwise -noted; insulation may -be -any -one -layer -or -combination of-polyisocyanurate,—polystyrene; wood fiberboard; perlite,—gypsum-based-roof board -or mineral-wool-roof-board-that-meets-the-OA requirements of F.A.C. Rule 61G20-3 and is documented as meeting FBC 1505.1 and, for foam plastic, FBC Chapter 26, when Installed with the roof cover. Having Jurisdiction. -- Exterior Research and Design, U.C. d/b/a Trinity( ERD Evaluation Report P9290.02.08-R20 for FL1654-RZ2 Certificate of Authorization #9503 dm EDITION (7017) FBC NON-HVHZ EVALUATION Revision 20: 09/12/2017 Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Appendix 1, Page 1 of 58 15. Unless otherwise noted, refer to the following references for bonded base, ply or cap sheet applications 16. �INITY (Etta :... TA®tE 1. POLXGtA55 �00F COVEhS; Reference Layer Material Application 'BP -AA Base Ply One or more plies Polyglass 62 Base, FBC Approved ASTM D4601, Type II Hot Asphalt at 20-40 (Base and Ply sheets, Asphalt- Ply One or more plies Polyglass Ply IV, Polyglass Ply VI, FBC Approved ASTM D2178, Type IV or VI Applied) Note: Asphalt -applied sheets or insulation shall not be applied to oly film surfaced membranes. Ibs/square Base Ply One ply Elastobase (sand/sand), Elastoflex V, Elastoflex S6, Elastoflex S6 Type 11, Polyglass HT Base 650 SBS-CA1 Cap Ply Elastoflex VG, Elastoflex VG FR, Elastoflex S5, Elastoflex S6 Type II, Elastoflex S6 G, Elastoflex S6 G FR, Elastoshield TS-G, Elastoshleld PG350 at 1.5-2.0 gal/square TS-G FR, Polyfresko G SBS (sand -backed), Polyfresko G SBS FR (sand -backed) Base Ply One ply Elastobase (sand/sand), Elastoflex V, Elastoflex S6, ElastoflexS6 Type 11 35 SBS-CA2 Cap Ply Elastoflex VG, Elastoflex VG FR, Elastoflex S6, Elastoflex S6 Type II, Elastoflex S6 G, Elastoflex S6 G FR, Elastoshield TS-G, Elastoshield Polyplus at 1.5-2.0 gal/square TS-G FR, Polyfresko G SBS (sand -backed), Polyfresko G SBS FR (sand -backed) Base Ply or Ply One or more plies Elastobase (sand/sand or poly/sand), Elastobase P (sand/sand or poly/sand), Elastoflex V, Elastoflex S6, Elastoflex S6 Type II, Polyglass HT Base 650 SBS-AA (SBS, Asphalt -Applied) Cap Ply - Elastoflex V, Elastoflex VG, Elastoflex VG FR, Elastoflex S6, ElastoflexS6 Type 11, Elastoflex S6 G, ElastoflexS6 G FR, Elastoshleld TS-G, Hot Asphalt at 20-40 Ibs/square Elastoshteld TS-G FR, Polyfresko G SBS (sand -backed), Polyfresko G SBS FR (sand -backed) Note: Asphalt -applied sheets or insulation shall not be applied topoly-film surfaced membranes. Base Ply or Ply 650 or more'plies Elastobase (sand/poly), Elastobase (poly/poly), Elastoflex V, Elastoflex S6, Elastoflex S6 Type It, Polyglass HT Base SBS-TA (SBS, Torch -Applied) Cap Ply Elastoflex V, Elastoflex VG, Elastoflex VG FR, Elastoflex S6, Elastoflex S6 Type 11, Elastoflex S6 G, ElastoflexS6 G FR, Elastoshield TS-G, Torch -Applied Elastoshield TS-G FR, Polyfresko G SBS (poly -film backed), Polyfresko G SBS FR (poly -film backed) -oh0daSe:PI _ . e,orzmore3sltes Elastoflex S A Base;,Ej f- efl=w5/t-V-�F.R Base; Elastoflex SA V.Pltts, Elastoflex SA V PIus,FR MAditerin SBS, Self-Adherin ( g)� Note: Unless of erwlse noted, permissible membrane substrates for SBS SA are limited to the SBS SA Base Ply options herein, SF! Elastobase (poly/sand) or Elastobase (poly/poly). APP-CA1 Cap Ply Polyflex G FR PG350 at 15-2.0 gal/square APP-TA Base Ply or Ply One or more plies Polyglass APP Base, Polyflex, Polybond Torch -Applied Cap Ply Polyflex, Polyflex G, Polyflex G FR, Polybond, Po)ybpnd G, Polyfresko G, Polyfresko G FR (APP, Torch -Applied) P ly'flex SAtPyfle' ux SA�FRTPoIy"fres S ,Pa ykool P SA"" �(APP,aAeR ngi elf-Adht sing Note: Unless otherwise noted, permissible membrane substrotesfor APP-SA are limited to the SBS-SA Base Ply options herein, /' Elastobase (poly/sand) or Elostobase (poly/poly). Any of the following FBC Approved coatings may be applied to the top roof membrane without adverse effect on the system wind load performance. Refer to current Roofing Materials Directory for fire.ratings associated with coating usage. ➢ P6200 Non Fibered Roof Coating; ➢ PG300 Fibered Roof Coating; ➢ PG600 Non-Flbered Aluminum Roof Coating; D PG650 Fibered Aluminum Roof Coating; D PG700 High Quality Elastomeric Roof Coating or KM Acryl 25; D PG700QS (QuickSet) High Quality Elastomeric Roof Coating or KM Acryl 25-OS (forgranule-surfaced APP or SBS only); ➢ PG800 Asphalt Emulsion Roof Coating; D Polyplus 60 Premium Non-Fibered Aluminum Roof Coating; D Polyplus 65 Premium Fibered Aluminum Roof Coating; D Polybrite 70 Premium Grade Elastomeric Roof_Coating or KM Acryl 15;__— Polyhrite 70QS (Quick Set) Premium Grade Elastomeric Roof Coating or KM Acryl 15-QS (for granule -surfaced APP cr SBS only); D Polybrite 90 High Solids Silicone Roof Coating or Polybrite 95 Silicone Roof Coating. Exterior Research and Design, LLC. d/b/a Trinity IERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 6'" EDITION (2017) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Evaluation Report P9290.02.08-R20 for FL16WR22 Revision 20: 09/12/2017 Appendix 1, Page 3 of 58 I TRINITY (ERD ............ NON = Oxx TYTO� System Base Sheet Roof Cover (Note 15) MDP No. Deck (Note 1) Type Fasten Attach Base Ply Cap IPA 1 S -ADH '7 ELF PJ .. -A . Min. 19/32- Elastobase, Elastobase P Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast#14 12-inch o.c. In 4-Inch lap and 12-inch o.c. In two SBS-SA SBS-SA, APP-SA, SBS- -52.5* W-136 inch plywood (poly -film top) or Trufast 3" Metal Insulation Plate with Trufast HD (2), equally spaced, staggered center rows TA, APP-TA Min. 19/32- Elastobase, Elastobase P Dekfast Hex (aka, Dekfast PLT-H-27/8) with Dekfast #14 12-Inch o.c. in 4-Inch lap and 12-Inch o.c. In two Polyflex SA Base APP-TA -52.5* W-137 inch plywood (poly -film top) orTrufast 3" Metal Insulation Plate with Trufast HD (2), equally spaced, staggered center rows W-138 Min. 19/32- Elastobase, Elastobase P OMG Flat Bottom Plates (square) with Roofgrip #12 12-Inch o.c. In 4-Inch lap and 12-Inch o.c. In two SBS-SA SBS-SA, APP-SA, SBS- -60.0* Inch plywood (poly -film top) (2), equally spaced, staggered center rows — I TA, APP-TA W-139 Min. 19/32- Elastobase, Elastobase P OMG Flat Bottom Plates (square) with Roofgrlp #12 1 12-inch o.c. In 4-Inch lap and 12-Inch o.c. In two 1 Polyflex SA Base I APP-TA 60.0* Inch plywood , (poly -film top) (2), equally spaced, staggered center rows I I TABLE NEW 40. STR System Deck (Note 1) Primer Roof Cover (Note 15) MDP (psf) Joint Treatment Base Ply Ply Cap Ply No. W-140 Min. 25/32- None None SBS-SA (Optional) SBS-SA, SBS- SBS-SA, APP-SA, SBS- -90.0 Inch plywood TA, APP-TA TA, APP-TA n. 2- qrqipase�� w- A MMMtft w.0; W-142 PG100 None SBS-SA (Optional) SBS-SA, SBS- SBS-SA, APP-SA, SBS- -97.S inch plywood TA, AP P-TA TA, APP-TA Min. 15/32- Plywood joints are covered with 4-Inch wide strips of Elastoflex SA Plus, rolled Into Elastoflex SA V Base or (Optional) SBS-SA, SBS- SBS-SA, APP-SA, SBS- -97.5 W-143 inch plywood (Optional) PG100 place to create continuous bond. Elastoflex SA FR Base TA, APP-TA TA, APP-TA W-144 Min. 15/32- WB-3000 None SBS-SA (Optional) SBS-SA, APP-SA, SBS- TA, APP-TA -105.0 Inch plywood Min. 15/32- Plywood joints are covered with 4-Inch wide strips of Elastoflex SAV Plus, rolled Into Elastoflex SA V Plus or (Optional) SBS-SA, SBS- SBS-SA, APP-SA, SBS- _135.0 W-145 inch plywood (Optional) PG100 p place to create continuous bond. Elastoflex SA V Plus FR TA, APP-TA TA, APP-TA W-146 Min. 15 1 (Optional) PG100 F( Plywood joints are covered with 4-Inch wide strips of Elastoflex SA Plus, rolled Into I Polyflex SA Base (Optional) APP-TA APP-TA -135.0 inch plywood place to create continuous bond. Exterior Research and Design, LLC. d/b/a Trinity I ERD Evaluation Report P9290.02.08-R20 for FL1654-R22 Certificate of Authorization #9503 gn' EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20:09/12/2017 Prepared by: Robert Nleminen, PE-59166 Polyglass Modified Bitumen Roof Systems, (570) 384-1230 Appendix 1, Page 21 of 58