Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutPRODUCT APPROVAL - MODIFIED BITUMEN1
FLORIDA ORPAPTMONr OF
Business & Professional Regulation
r�rra
BCIs Home i Lag In I User Registration Hot Topic I Submit
Surcharge I Stats & Facts Publications
Contact Us I BQS Site Map Unks I Search I
Florida
*ilhProduct Approval
q� USER: Public User
Produce Approval Menu > Product ar Aoollcatlon Search > Application Llst> Application Detail
`S�eyNED
FL #
FL1654-R22
Application Type
Revision
�(I.
Code Version
2017
Lvch§ coUn
Application Status
Approved
t y
Comments
Archived
I
Product Manufacturer
POLYGLASS USA
Address/Phone/Email
1111 W. Newport Center Drive
Deerfield Beach, FL 33442
(954)233-1330 Ext242
malpert@polyglass.com
Authorized Signature
Maury Alpert
malpert@polyglass.com
Technical Representative
Maury Alpert
Address/Phone/Email
1111 W. Newport Center Drive
Deerfield Beach, FL 33442
(912) 429-8610
MAlpert@polyglass.com
Quality Assurance Representative
Arlel Lender
Address/Phone/Email
1111 W. Newport Center Drive
Deerfield Beach, FL 33442
(954)'233-1230
ALender@polyglass.com
Category+
9
Subcategory
�l�do�dlz
Compliance Method
Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
❑ Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed Robert Nleminen
the Evaluation Report
Florida License
PE-59166
Quality Assurance Entity
UL LLC
Quality Assurance Contract Expiration Date .
09/13/2021
Validated By
John W. Knezevich, PE
© Validation Checklist - Hardcopy Received
Certificate of Independence
Ft t 654 R22 COI 2017 01 COI
Nieminen.pdf
Referenced Standard and Year (of Standard)
Standard
Year
ASTM D6162
2008
ASTM D6163
2008
ASTM P6164
2011
ASTM D6222
2011.
ASTM D6509
2009
FM 4470
2012
FM 4474
2011
UL1897
2012
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted
09/14/2017
Date Validated
09/15/2017
Date Pending FBC Approval
09/22/2017
Date Approved
12/12/2017
Date Revised
10/08/2018
Summary of Products
FL #
Model, Number or Name
Description
fit
Polyg ass 58Sland APP�I710 Ified
SBS and,APP4 modifiedblEuiflef}xraofysCe
glti(inen{Rgof5y5�h7s
Limits of Use
Installation Instructions
Approved for use In HVHZ: No
Fit 654 R22 II 2017 09 FINAL Al ER POLYGLASS MODBIT FL1654-
R22.Ddf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Robert Nieminen PE-59166
Design Pressure: +N/A/-622.5
Created by Independent Third Party: Yes
Other: 1.) The design pressure In this application
Evaluation Reports
relates to one particular assembly over concrete
Fi t 654 R22 AE 2017 09 FINAL ER POLYGLASS MODBIT FL3654-
R22.Ddf
deck. Refer to the ER Appendix for other systems
and deck types. 2.) Refer to ER, Section 5 for other
Created by Independent Third Party: Yes
Limits of Use.
j
ea Next
i
Contact Us :: 2601 Blair Stone Road Tallahassee FL 32399 phone: 850-487-1824
The State of Florida Is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement:: Refund Statement
Under Florida law, emall addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic
mall to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address It they have one. The emalls
provided maybe used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
j provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, F.S., please click hue_.
Product Approval Accepts:
®®®FER®
I
Credit Card
Safe
•tti%
TRINITY I ERD
Table
Deck
Application
Type
Description
Page
1A
Wood
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
5
1B-1
Wood
New or Reroof (Tear -Off)
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
5-9
18-2
Wood
New, Reroof (Tear -Off) or Recover
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
10-11
1C
Wood
New, Reroof (Tear -Off) or Recover
B
Mech. Attached Base insulation, Bonded Top Insulation, Bonded Roof Cover
11
1D
Wood
New, Reroof (Tear -Off) or Recover
C
Mech. Attached Insulatlon, Bonded Roof Cover
12-13
1E
Wood
New, Reroof (Tear -Off) or Recover
D
Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover
14-15
1F-1
Wood
New or Reroof (Tear -Off)
E
Non -Insulated, Mech. Attached Base Sheet (nails), Bonded Roof Cover
16-18
1F-2
Wood
New, Reroof (Tear -Off) or Rec e
E
Non -Insulated, Mech. Attached Base Sheet (screws & plates), Bonded Roof Cover
19-21
ood
NOMErliffiSlavviz i[Eiigo (Tea - ff)
ao ve
-
2A
Steel or Structural concrete New, Reroof (Tear -Off) or Recover
B
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
22-24
2B
Steel or Structural concrete New, Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
25-28
2C
Steel or Structural concrete New, Reroof (Tear -Off) or Recover
D
Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover
29-31
3A
Structural concrete
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
32-40
3B
Structural concrete
New or Reroof (Tear -Off)
F
Non -Insulated, Bonded Roof Cover
40
4A
LWIC
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
41-42
4B
LWIC
New or Reroof (Tear -Off)
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
43
4C
LWIC
New or Reroof (Fear -Off)
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
44-46
SA
CWF
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
47
5B
CWF
New, Reroof (Tear -Off) or Recover
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
48
SC
CWF
New, Reroof (Tear -Off) or Recover
B
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
49
SD
CWF
New, Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
49
SE
CWF
New, Reroof (Tear -Off) or Recover
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
49
6A
Gypsum
Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
50-52
6B
Gypsum
Reroof (Tear -Off) or Recover
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
52
6C
Gypsum
Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
53
60
Gypsum
Reroof (Tear -Off) or Recover
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
53
7A
Various
Recover
A-1
Bonded Insulation, Bonded Roof Cover
54-58
7B
Various
Recover
F
Non -Insulated, Bonded Base Sheet, Bonded Roof Cover
58
to the systems outlined herein:
The following apply to the systems outlined herein
1. The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority
Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation.
2. Insulation / base sheet fasteners shall be of sufficient length for the following deck engagement:
➢ Wood: Minimum 0.75-Inch penetration.
➢ Steel: Minimum 0.75-Inch penetration and engage the top flute of the steel deck.
➢ Structural concrete: Minimum 1-Inch embedment Into pilot hole in accordance with fastener manufacturer's published installation instructions.
— - 3 Unless otherwise -noted; insulation may -be -any -one -layer -or -combination of-polyisocyanurate,—polystyrene; wood fiberboard; perlite,—gypsum-based-roof board -or mineral-wool-roof-board-that-meets-the-OA
requirements of F.A.C. Rule 61G20-3 and is documented as meeting FBC 1505.1 and, for foam plastic, FBC Chapter 26, when Installed with the roof cover.
Having Jurisdiction.
--
Exterior Research and Design, U.C. d/b/a Trinity( ERD Evaluation Report P9290.02.08-R20 for FL1654-RZ2
Certificate of Authorization #9503 dm EDITION (7017) FBC NON-HVHZ EVALUATION Revision 20: 09/12/2017
Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Appendix 1, Page 1 of 58
15. Unless otherwise noted, refer to the following references for bonded base, ply or cap sheet applications
16.
�INITY (Etta
:... TA®tE 1. POLXGtA55 �00F COVEhS;
Reference
Layer
Material
Application
'BP -AA
Base Ply
One or more plies Polyglass 62 Base, FBC Approved ASTM D4601, Type II
Hot Asphalt at 20-40
(Base and Ply sheets, Asphalt-
Ply
One or more plies Polyglass Ply IV, Polyglass Ply VI, FBC Approved ASTM D2178, Type IV or VI
Applied)
Note:
Asphalt -applied sheets or insulation shall not be applied to oly film surfaced membranes.
Ibs/square
Base Ply
One ply Elastobase (sand/sand), Elastoflex V, Elastoflex S6, Elastoflex S6 Type 11, Polyglass HT Base 650
SBS-CA1
Cap Ply
Elastoflex VG, Elastoflex VG FR, Elastoflex S5, Elastoflex S6 Type II, Elastoflex S6 G, Elastoflex S6 G FR, Elastoshield TS-G, Elastoshleld
PG350 at 1.5-2.0
gal/square
TS-G FR, Polyfresko G SBS (sand -backed), Polyfresko G SBS FR (sand -backed)
Base Ply
One ply Elastobase (sand/sand), Elastoflex V, Elastoflex S6, ElastoflexS6 Type 11
35
SBS-CA2
Cap Ply
Elastoflex VG, Elastoflex VG FR, Elastoflex S6, Elastoflex S6 Type II, Elastoflex S6 G, Elastoflex S6 G FR, Elastoshield TS-G, Elastoshield
Polyplus at 1.5-2.0
gal/square
TS-G FR, Polyfresko G SBS (sand -backed), Polyfresko G SBS FR (sand -backed)
Base Ply or Ply
One or more plies Elastobase (sand/sand or poly/sand), Elastobase P (sand/sand or poly/sand), Elastoflex V, Elastoflex S6, Elastoflex
S6 Type II, Polyglass HT Base 650
SBS-AA
(SBS, Asphalt -Applied)
Cap Ply
-
Elastoflex V, Elastoflex VG, Elastoflex VG FR, Elastoflex S6, ElastoflexS6 Type 11, Elastoflex S6 G, ElastoflexS6 G FR, Elastoshleld TS-G,
Hot Asphalt at 20-40
Ibs/square
Elastoshteld TS-G FR, Polyfresko G SBS (sand -backed), Polyfresko G SBS FR (sand -backed)
Note:
Asphalt -applied sheets or insulation shall not be applied topoly-film surfaced membranes.
Base Ply or Ply
650 or more'plies Elastobase (sand/poly), Elastobase (poly/poly), Elastoflex V, Elastoflex S6, Elastoflex S6 Type It, Polyglass HT Base
SBS-TA
(SBS, Torch -Applied)
Cap Ply
Elastoflex V, Elastoflex VG, Elastoflex VG FR, Elastoflex S6, Elastoflex S6 Type 11, Elastoflex S6 G, ElastoflexS6 G FR, Elastoshield TS-G,
Torch -Applied
Elastoshield TS-G FR, Polyfresko G SBS (poly -film backed), Polyfresko G SBS FR (poly -film backed)
-oh0daSe:PI
_ . e,orzmore3sltes Elastoflex S A Base;,Ej f- efl=w5/t-V-�F.R Base; Elastoflex SA V.Pltts, Elastoflex SA V PIus,FR
MAditerin
SBS, Self-Adherin
( g)�
Note:
Unless of erwlse noted, permissible membrane substrates for SBS SA are limited to the SBS SA Base Ply options herein,
SF!
Elastobase (poly/sand) or Elastobase (poly/poly).
APP-CA1
Cap Ply
Polyflex G FR
PG350 at 15-2.0
gal/square
APP-TA
Base Ply or Ply
One or more plies Polyglass APP Base, Polyflex, Polybond
Torch -Applied
Cap Ply
Polyflex, Polyflex G, Polyflex G FR, Polybond, Po)ybpnd G, Polyfresko G, Polyfresko G FR
(APP, Torch -Applied)
P
ly'flex SAtPyfle' ux SA�FRTPoIy"fres S ,Pa ykool
P SA""
�(APP,aAeR ngi
elf-Adht sing
Note:
Unless otherwise noted, permissible membrane substrotesfor APP-SA are limited to the SBS-SA Base Ply options herein,
/'
Elastobase (poly/sand) or Elostobase (poly/poly).
Any of the following FBC Approved coatings may be applied to the top roof membrane without adverse effect on the system wind load performance. Refer to current Roofing Materials Directory for fire.ratings
associated with coating usage.
➢ P6200 Non Fibered Roof Coating;
➢ PG300 Fibered Roof Coating;
➢ PG600 Non-Flbered Aluminum Roof Coating;
D PG650 Fibered Aluminum Roof Coating;
D PG700 High Quality Elastomeric Roof Coating or KM Acryl 25;
D PG700QS (QuickSet) High Quality Elastomeric Roof Coating or KM Acryl 25-OS (forgranule-surfaced APP or SBS only);
➢ PG800 Asphalt Emulsion Roof Coating;
D Polyplus 60 Premium Non-Fibered Aluminum Roof Coating;
D Polyplus 65 Premium Fibered Aluminum Roof Coating;
D Polybrite 70 Premium Grade Elastomeric Roof_Coating or KM Acryl 15;__—
Polyhrite 70QS (Quick Set) Premium Grade Elastomeric Roof Coating or KM Acryl 15-QS (for granule -surfaced APP cr SBS only);
D Polybrite 90 High Solids Silicone Roof Coating or Polybrite 95 Silicone Roof Coating.
Exterior Research and Design, LLC. d/b/a Trinity IERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
6'" EDITION (2017) FBC NON-HVHZ EVALUATION
Polyglass Modified Bitumen Roof Systems; (570) 384-1230
Evaluation Report P9290.02.08-R20 for FL16WR22
Revision 20: 09/12/2017
Appendix 1, Page 3 of 58
I TRINITY (ERD
............
NON = Oxx TYTO�
System
Base Sheet
Roof Cover (Note 15)
MDP
No.
Deck (Note 1)
Type Fasten Attach
Base Ply Cap
IPA
1
S -ADH '7
ELF PJ ..
-A
.
Min. 19/32-
Elastobase, Elastobase P
Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast#14
12-inch o.c. In 4-Inch lap and 12-inch o.c. In two
SBS-SA
SBS-SA, APP-SA, SBS-
-52.5*
W-136
inch plywood
(poly -film top)
or Trufast 3" Metal Insulation Plate with Trufast HD
(2), equally spaced, staggered center rows
TA, APP-TA
Min. 19/32-
Elastobase, Elastobase P
Dekfast Hex (aka, Dekfast PLT-H-27/8) with Dekfast #14
12-Inch o.c. in 4-Inch lap and 12-Inch o.c. In two
Polyflex SA Base
APP-TA
-52.5*
W-137
inch plywood
(poly -film top)
orTrufast 3" Metal Insulation Plate with Trufast HD
(2), equally spaced, staggered center rows
W-138
Min. 19/32-
Elastobase, Elastobase P
OMG Flat Bottom Plates (square) with Roofgrip #12
12-Inch o.c. In 4-Inch lap and 12-Inch o.c. In two
SBS-SA
SBS-SA, APP-SA, SBS-
-60.0*
Inch plywood
(poly -film top)
(2), equally spaced, staggered center rows —
I
TA, APP-TA
W-139
Min. 19/32-
Elastobase, Elastobase P
OMG Flat Bottom Plates (square) with Roofgrlp #12
1
12-inch o.c. In 4-Inch lap and 12-Inch o.c. In two
1
Polyflex SA Base
I
APP-TA
60.0*
Inch plywood
, (poly -film top)
(2), equally spaced, staggered center rows
I
I
TABLE NEW 40. STR
System
Deck (Note 1)
Primer
Roof Cover (Note 15)
MDP (psf)
Joint Treatment
Base Ply
Ply
Cap Ply
No.
W-140
Min. 25/32-
None
None
SBS-SA
(Optional) SBS-SA, SBS-
SBS-SA, APP-SA, SBS-
-90.0
Inch plywood
TA, APP-TA
TA, APP-TA
n. 2-
qrqipase��
w- A
MMMtft
w.0;
W-142
PG100
None
SBS-SA
(Optional) SBS-SA, SBS-
SBS-SA, APP-SA, SBS-
-97.S
inch plywood
TA, AP P-TA
TA, APP-TA
Min. 15/32-
Plywood joints are covered with 4-Inch wide strips of Elastoflex SA Plus, rolled Into
Elastoflex SA V Base or
(Optional) SBS-SA, SBS-
SBS-SA, APP-SA, SBS-
-97.5
W-143
inch plywood
(Optional) PG100
place to create continuous bond.
Elastoflex SA FR Base
TA, APP-TA
TA, APP-TA
W-144
Min. 15/32-
WB-3000
None
SBS-SA
(Optional)
SBS-SA, APP-SA, SBS-
TA, APP-TA
-105.0
Inch plywood
Min. 15/32-
Plywood joints are covered with 4-Inch wide strips of Elastoflex SAV Plus, rolled Into
Elastoflex SA V Plus or
(Optional) SBS-SA, SBS-
SBS-SA, APP-SA, SBS-
_135.0
W-145
inch plywood
(Optional) PG100
p
place to create continuous bond.
Elastoflex SA V Plus FR
TA, APP-TA
TA, APP-TA
W-146
Min. 15 1
(Optional) PG100
F(
Plywood joints are covered with 4-Inch wide strips of Elastoflex SA Plus, rolled Into
I
Polyflex SA Base
(Optional) APP-TA
APP-TA
-135.0
inch plywood
place to create continuous bond.
Exterior Research and Design, LLC. d/b/a Trinity I ERD Evaluation Report P9290.02.08-R20 for FL1654-R22
Certificate of Authorization #9503 gn' EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20:09/12/2017
Prepared by: Robert Nleminen, PE-59166 Polyglass Modified Bitumen Roof Systems, (570) 384-1230 Appendix 1, Page 21 of 58