Loading...
HomeMy WebLinkAboutSTEEL ROOF PANELr Compliant with Florida Building Code 2017 (611 ed.) Compliant with Florida Product Approval Rule # 61G20-3 Compliant: Keystone Certifications Palm'City, FL 34990 SCANNEL BY St Lucie.Col Product:5 V Crimp 26GA Steel Roof Panel FBC Sec.1507.4.2 Yield strength: 50 ksi min.; Attached to min.15/32" plywood or Wood ®eck w/ min. 0.42 specific gravity with screws. 24" Coverage Rib Height 3/8" Corrosion Resistant Compliant: FBC Sec.1507.4.3 Fastener 1(Method 1 Attachment): #9 x 1-1/2" Hex -Washer Head wood screw* to penetrate 3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length to, meet Fastener 2 (Method 2,3, & 4 Attachment): #10 x 1-1/2" Hex -Washer Head wood screw* to penetrate, 3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length to meet requirements) Underlayment: To be compliant with FBC Sec. Chart 1507.1.1 i Slope: Shall be in compliance with FBC Sec.1507. See Fastener attachment specifications above Install Details: Table A Allowable Loads METHOD 1 tMETH(D 2' METHOD 3 METHOD 4 DESIGN PRESSURE* -86 PSF -93.5 PSF -101 PSF -228 PSF ROW SPACING 16" O.C. 16" ox. 8" O.C. 6" ox. FASTENER SPACING (ALONG Panel width) 22" o.c. 12",o.c.. 12" ox. 12" ox. FASTENER SIZE #9 ri;X s 10, #20 1 #10 Reference Data: ARCHITECTURAL TESTING, INC. TST ID#:1527 UL 580-06 1897-041 Test Report EMS93.01-450-18 05/02/14 Test Report F3366.01-450-18 iz/28/25 TAS 125-03 Test Report . D05893.02-450-18 07/22/14 *EQUIVALENCY-UL 1897--04 is equivalent to test standard UL 1897--i *Design pressure margin of safety 2:1 Locke Bowden,, P.E. does not have, not will acquire a financial iTO n�q Lcgq�m$iyfacturing or, distributing products under this evaluation. • • ' Locke Bowden,j P.E. is not owned, operated, or controlled by a& colpanvpmbfldure0, or distributing products under this • • report. � , • * � ;.' • l J : G•e Or 04, ,%3 i �FL1702211 LSUCrilrnpt(26GA Stee1),24" Wide Roof Palriel 'Details =q ,, Limitations: 1. Underlayme',t to be compliance with current Florida Building Code (FBC)2017 6th ed. 2. Minimum slope to be compliant with Florida Building Code 2017 6t' ed., and per with Manufacturer's installation reference. 3. Products are, compliant for State of Florida product approval per Rule 61 G20-3. Compliance Method: 1-1) 4. Engineering analysis for "project specific approval by local authorities wrurisdiction is allowed by other registered engineers. 5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this.report. 6. Support framing in compliance w/FBC 2017 6t' ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for Structural Loading. . 7. This report does not imply warranty, installation, recommended product use outside of this report. A Deck 1MZ' or greater Plywood, or Mod plank — Fasteners - N x 1-11P" Minor #10 x 1-1@'' Min. per Table A- for Row 5-V Crimp Roof Panel Spacing and Design Pressures Hex Washer Head Wood Screws 24" 12" 318" Panel Profile Nominal12" Nominal12" O.C. O.C. Fasten V9 x 1-1/2" Min. or #10 x 1-1/2" Min. per able'A" Hex Washer Head Screw cross the Panel Wdth Panel Refer to Table Aa for Spacing Along Panel Overlap Length Deck- 15/32" or greater plywood, or - Wood plank