HomeMy WebLinkAboutPRODUCT APPROVAL - STEEL ROOF PANELCompliant with Florida Building Code 2017 (611 ed.)
Compliant with Florida Product Approval Rule # 61G20-3
Compliant: Keystone Certifications
2160 SW Poma Drive
Palm City, Fl. 34990
SCANNED
St Lucie.Coun
tv
Product:4' NaWp=25GA Steel > oof�P..anel+BC�Sec 1507:4:2�
!Yield strength: 50 ksi min.; Attached to min.15/32" plywood or
;Wood Deck w/ 0.42 specific gravity with 16" Coverage (Max.)
'Rib Height 1"
Corrosion Resistant Compliant: FBC Sec.1507.4.3
Fastener11: #10 x 1" (min.) Pancake Head Wood Screw to penetrate 3/16" (min.) thru
bottom of support.
Adhesive/Sealant : Bostik 9151 Chem -Chalk one component, polyurethane adhesive with
3/16" continuous bead application along base of male rib vertical flange at each panel
seam.
Underlayment: To be compliant with FBC Sec 1507.1.1
1
Slope: Shall be in compliance with FBC Sec.1507.
Install Details: Table A Allowable Loads
METHOD.,;1I
METHOD 2
DESIGN PRESSURE* __:--
� PSF Main iet
-97.25 PSF Perimeter
FASTENER SPACING
_.� �__.. _
` 6°' O,C.= ,
6" O.C.
_ ... --...
SEAM ADHESIVE
, Not re ur
r�
3/16" continuous bead
_. _.__..........:.., ................_.._--.._.._ _ .._ .... _.__.—:.—
'-- ....-.,.._.. _......
a
.(.see det Us)
Reference Data: ARCHITECTURAL TESTING, INC. TST ID#: 1S27
UL S80-06 & UL 1897-04 TEST REPORT D8133.01-450-18 06/30/15 Specimen #1 & #2
i
EQUIVALENCY: UL1897--04 is equivalent to Test Standard UL1897-12. *Design Pressure margin of safe 2:1
Certificate!of Independence:
Locke Bowden, P.E. does not have, not will acquire a financial ii�{�s[Qny company manufacturing or distributing products
under this evaluation. •••��� G D • g0 y� �i,
Locke Bowden, P.E. is not owned, operated, or contrail e�y'�mR� ihancturer, or distributing products under this
report. . •
• x
• ' seal
� -o • ' 4
•• STATE OF
�'.0r•••.�aV .
Limitations:
1. Underlayment to be compliance with current Florida Building Code (FBg20l 7 61h ed..
2. Minimum slope to be compliant with Florida Building Code 2017 6t' ed., and perwith Manufacturer's installation reference.
3. Products are compliant for State of Florida product approval per Rule 61 G20-3. Compliance Method: 1-D
4. Engineering analysis for"project specific approval by local authorities wfjurisdiction is allowed by other registered engineers.
5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report.
6. Support framing in compliance w/FBC 2017 61' ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for Structural
Loading.
7. This report does not imply warranty, installation, recommended product use outside of this report.
I
FL 17022.6 1.0 Nail Strip (26GA Steel), 16" Wide Roof Panel - Details
16"
Panel Profile
16" O.C.
Deck:
-15/32" or greater Plywood, or
- Wood plank
Snap Lock
For METHOD 2:
Apply 3116" Bead Bostik 915T^" Sealant
Continuous Along Male Rib Vertical Flange
Fastener
#10 x V Min. per Table "A"
Pancake Head Wood Screw
(Typical Fastening Pattern Across Width)
ill
I
FL 17022.6 1.0 Nail Strip (26GA Steel),16" Wide Roof Panel - Details
i
15/32" or greater Plywood, or Apply 3/16" Bead Bostik 9151- Sealant
-Wood plank Continuous Along Male Rib Vertical Flange
(Refer to Table "A")
Isometric View