Loading...
HomeMy WebLinkAboutROOFING SPECIFICATIONArchitectonic Inc October 30, 2018 Saint Lucie County Building Department SCANNED Attn: Roof Permit Plan Review BY 2300 Virginia Avenue St Lucie Count Ft. Pierce, FL 34982 Re: Roofing specification prepared for the St. Lucie County Building Dept. for the structure located at 308 Bay Street, Saint Lucie County, Florida Manufacturer: Profiles: Code: Wind Speed: Exposure: Mean Roof Height: Pitch: Required Design Pressure: Maximum Uplift Pressure: Base: Ply Sheet: Cap: Roof Decking: Polyglass USA Modified Bitumen Roof System, FL #1654-1122, System #W-140 FBC 2017; Section 905 160 MPH; Ultimate Design Wind Speeds C 30' Maximum 1.5/12 Minimum Zone1: -31.46 Zone 2: -49.61 Zone3: -68.97 -90 psf SBS-SA (self- adhering) (Optional) SBS-SA, (self -adhering) SBS-TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA Existing 5/8" plywood sheathing to be nailed w/8d x 2" ring shank @ 6" O.C. thru out zone 1, 4" O.C. perimeter, and 6" O.C. field zone 2, and 4" O.C. thru out zone 3. The above.approved, as per Florida Building Code Compliance acceptances, 2017 Florida Building Code, and the Manufacturer's recommendations. 806 Delaware Avenue Tel: 772 460 7751 www.architectonicinc.com Fort Pierce, Florida 34950 Fax: 772 460 4244 FL Reg #AA26003348 1 of 1