HomeMy WebLinkAboutEVALUATION REPORT - UNDERLAYMENTSSC MEMO etc.
SCANNED Certificate of Authorization. #32455
St LUCI� C Olaof 353 Christian Street ,'Unit #13
y Oxford, CT 06478
(203)262-9245
ENGINEER EVALUATE TEST CONSULT. CERTIFY
REPORTEVALUATION
Soprema, Inc. Evaluation Report S18010.06:09-R12
1640 rue Haggerty FL2569-R14
Drummondville, Quebec.12C 5P8 . Canada Date of.Issuance: 06/15/2009
(819) 478-2400 Revision '12: 02/12/2018
SCOPE:
This Evaluation Report is issued under Rule 6118204 and the applicable rules and, regulations governing the use of
construc I ion materials in the State of Florida.'The documentation submitted has been reviewed by'RobertNieminen,
P.E. for use of the product under the Florida, Building Code and.Florida Building Code, Residential Volume. The
products described herein have. been evaluated for compliance with the 6 h Edition (2017) Florida Building Code
sections noted herein.
DESCRIPTION: Soprema, Roof Underlayments
LABELING: Labeling shalt be in accordance with the requirements of the Accredited. Quality Assurance Agency, noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is,valid until such time as the named product(s) ' changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate -to the product change. Acceptance of
this Evaluation Report by the named, client constitutes agreement. to. notify Robert Nieminen, P.E. of any changes to
the product(s), the. Quality Assurance or the'production facility location(s).- NEMOI etc. requires a complete review of
this Evaluation Report relative to.updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMOletc. Evaluated" may be displayed in
advertising.literature. If any portion of the Evaluation Report is displayed,.then it shall be.done in Its entirety.
INSPECTION: Upon request,.a copy of this -entire. Evaluation Report shall be provided to the user by the manufacturer or
its.distr'�butors and shall. be available for inspection at the job site at the request of the'Building Official.
This Evai uation Report consists of pages 1 through 8.
Prepared by: Ali
Robert J.M. Nieminen, P.E. ••'aik e; d« ��? , The facsimile seal appearing was authorized by Robert
Florida a istration No. 59166, Florida DCA ANE1983 i �.,5�� Nieminen, P.E. on 02/12/s018. This does not serve as.an
9 el ectronicallysigried document.
•t .
CERTIFICATION OF INDEPENDENCE:
1. NEMO ETC, LLC does.not have, not does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. NE ETC, LLC is not owned, operated or.controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen; P.E. does not have nor will acquire, a financial interest.in any company manufacturing or distributing products -for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have; nor will.acquire, a financial interest in any other entity involved in the approval process of the.
product.
S. This is a building code evaluation. Neither NEMOletc. nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
spei ificallyforthatpurpose.
Product Category: Roofing
Sub -Category: Underlayment
Compliance Statement: Roof Underlayments, as produced by Soprema; have demonstrated compliance with the
following sections of the 6h Edition (2017) Florida Building Code through -testing in accordance with the:following
Standards. Compliance is subject. to the Installation Requirements and Limitations % Conditions of Use set forth
�ierein..
Section
:•.Pro a
Standard
i1504.3.1
Wind Resistance'
FM 4474
2011
504.3.1
Wind Uplift
UL 1897
2012
2507.2.4/1507.1.1, 1507.2.9.2
Physical Properties.
ASTM D1970 .
2015
Physical Properties
FRSA/TRI April 2012
2012
115O7.3.3
FRSA/TRI April 2012 (04-12),
Physical Properties
ASTM D6163
2008
TAS 110
Accelerated Weathering
ASTM D4798
2011
4.1.
4.2
4.3
4.4•
Entity
:. ' Examination _..::...,..Reference,'
. Reference .. ...
Date: :.
ERD (TST6049)
ASTM D1970 / TAS 110
2968.05.04-2 .
.05/14/2004
ERD (TST6049)
Physical Properties
2757.02.05
02/03/2005
ERD (TST6049)
ASTM D1970/TAS 110
2974.03.05-2,
05/17/2005
ERD (TST6049)
Wind Resistance
2778.07.05
07/15/2005
ERD (TST6049)
Wind Resistance
2779.11.05-R1
04/18/2007
ERD (TST6049)
TAS 109 / TAS 110
S7120.11.07-2
11/02/2007 .
ERD (TST6049)
ASTM D1970 / TAS 110
513190.02.09-111 .
04/01/2010
ERD (TST6049)
ASTM :D1970 / TAS 110
S31370.03.10-1-R1 ..
04/07/2010
ERD (TST6049)
Physical Properties / Tensile Adhesion
S11150.05.10-R1
09/09/2010
ERD (TST6049)
Physical Properties / Tensile Adhesion
S11150.05.097R2 -
10/05/2010
ERD (TST6049)
ASTM D1970
S37210.11.11
11/09/2011
ERD (TST6049)
ASTIVI D1970 .
S40540.02.13-1
02/19/2013
ERD (TST6049)
Physical Properties / Tensile Adhesion
S43530.02.14-1
02/21/2014
ERD (TST6049)
Physical Properties / Tensile Adhesion
SOPC-SC7645.02.15
02/13/2015
ERD (TST6049)
Accelerated Weathering
SOPC-SC8520.14
04/17/2015
ERD (TST6049)
Wind Resistance
SCIPC-SC14045.05.17=111
06/07/2017
M-D (CER3592) _'
HVHZ Compliance
15-0508.04 .
09/24/2015
ICC-ES (EVL2396)
2015 IBC Compliance
ESR-1524
03/01/2017
PRI (TST5878)
Physical Properties
SOP-064-02-01
12/03/2013
Soprema, Inc. (PDM3511)
Equivalency Declaration
SASMOOTH PLY40
06/29/2015
UL, LLC. (QUA9625)
Quality Control
Service Confirmation
Exp. 07/18/2020
Lastobond TU. HT is. a •self -adhering, non -woven polyester fabric surfaced, ' •SBS modified bitumen roof
underlayment; meets ASTM D1970 and FRSA/TRI April 2012 (04-12).
Lastobond Shield is a 'self -adhering, woven polyethylene surfaced, SBS modified bitumen roof underlayment
available in two widths; 36 and 45. inch; meets ASTM D1970.
RESISTO 'SA SMOOTH PLY 40 is a self -adhering, woven polyethylene. surfaced, SBS modified bitumen roof
underlayment; available in 3.3 ft x 65 ft rolls; meets ASTM D1970.
Lastobond Shield HT is a self -adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof
underlayment; meets ASTM D1970.
NEMO ETC LLC Evaluation Reports18010.06.09-R12
Ceri lwtel ofAuthorliation #32455 6P EDITION (2017). FBC NON-HVHZ EVALUATION FL2569-R14
Soprema RoofUnderlayments Revision 12: 02/12/2018
Page 2 of 8
f
NEM0' etc.
4.5 Lastobond, Pro HT-N is a self -adhering, woven .polyethylene surfaced, SBS modified bitumen roof underlayment
available in two widths; 36 and 45 inch; meets ASTM D1970..
4.6 Lastobond Pro HT-S is a self -adhering, woven polyethylene surfaced, high'temperature, SBS modified bitumen'roof
ul nderlayment; meets ASTM D1970:
4.7 EnviroShield is a self -adhering, woven., polyethylene surfaced, high temperature, SBS modified bitumen roof
underlayment; meets ASTM D1970.
4.8 Lastobond 295 is a self -adhering, glass -mat reinforced, sand -surfaced, SBS. modified bitumen roof underlayment;
meets ASTM D1970. -
4.9 Lastobond Eaves Protection Sheet is.a self -adhering, glass -mat reinforced, sand -surfaced, SBS modified bitumen
roof underlayment; meets ASTM D1970.
4.10 . Lastobond Eco.is a self -adhering, glass -mat reinforced, sand -surfaced, SBS modified bitumen roof underlayment;
meets ASTM D1970.
4.11 Lastobond Smooth Seal HT. is a self -adhering, glass -mat reinforced, film -surfaced, SBS modified bitumen roof
underlayment; meets ASTM D1970.
4.12 RESISTO LB1236 is a•self-adhering, glass -mat reinforced, sand -surfaced, SBS modified bitumen roof underlayment,
with a 36-inch sheet width; meets ASTM D1970.
4.13 •PrimeSource .Grip -Rite- Eave & Valley Protector is a self-adhering,'glass-mat reinforced,, sand -surfaced, SBS
modified bitumen roof underlayment, with a 36-inch sheet width; meets ASTM D1970. .
4.14 ESISTO LB1244 is a self -adhering, glass -mat reinforced, sand -surfaced, SBS modified bitumen roof underlayment,
With a 44-inch sheet width; meets ASTM D1970.
4.15 �Colphene ' FR GR is a self -adhering, fiberglass reinforced, granule -surfaced, SBS modified bitumen roof
underlayment; meets ASTM D1970 and FRSA/TRI April 2012 (04712).
5.1
5.2
5.3
5.4
5.5
This is a building code evaluation: Neither NEMO ETC, LLC nor Robert Nieminen; P.E, are, in anyway, the Designer
of Record for any project on -which this Evaluation Report, orprevious versions thereof, is/was used for permitting
or design guidance unless retained specifically for that purpose.
This Evaluation Report is not for use in. FBC HVHZ Jurisdictions.
Fire Classification is not part of this report; refer to current Approved Roofing Materials Directory for fire ratings of
this product.
Soprema. Roof Underlayments may be used with any. prepared roof cover where the product is specifically
referenced.within FBC approval documents. If not listed, a. request may be' made to the. Authority Having
Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering.
ROOF COVER
OPTIONS
•
Wood or
Slate or '.
-UndeNayment
Asphalt
Nail -On
-.Foam-On ;
Metal
Composite, .
composite
Shingles
Tile
Tile
Shakes&
Slate '.
Shingles
Lastobond TU HT
• .:::.::.:.
Yes;::, `:'
. . .
,:: Yes : -: ;
>. Yes:.:..-:
`-::.::
:. •....
Yes
, : ,
Yes•
Yes
:•: See.'5.5.1
. .
.
Lastobond Shield Pro HT N'�
/
RESISfO SA PLY 40
Yes
it Nc�Q t5
�4�s1t , Naas 'r n
<<"� N�osr s ,
Yes
Yes
SMOOTH
Lastobond Shield HT/pro HT-S'
..'' Yes , .;
•.A
i`i<NA , .
,....Yes .:.
; : "; Yes: •
Yes
EnviroShield
Yesy�f;l,�al^r`
Yes
6T" EblTION.(2017).FBC NON-HVHZ EVALUATION
Soprema Roof Underlayments
Evaluation Report S18010.06.09-R12
FL2569-R14
Revision 12: 02/12/2018
Page 3 of 8
�.� MEMO
I etc.
TABLE
1: ROOF COVER OPTIONS
Wood or
Asphalt •
Nail -On 'Foam' -On
Composite
Slate.or
Underlayment:,
Shingles
� Metal
Tile < Tile
Shakes &
Composite
f
f
�
81ate. .
:. •
Shingles
Lastobond Eaves Protection Sheet /
`Yes
iallo�
l}s Nam
Yes •
Yes
Lastobond 145
Lastobond ECO / RESISTO LB1236
'
k i�4'z
} K
Grip -Rite Eave & Valley Protector /
Yes, ;
4� ,
�Vb j,
r�',� j,
x¢ u Np�f
ar t
i
Yes . .
Yes
RESISTO LB1244
`�`
}flr
A •
a ,
r t.2vYwr a,+.?,.J
v,.vt,'�?a
y
HT
Yes.:
s
b Yes
Lastobond Smooth Seal
,Y.r;lVa'7„.rY,'No�>
.
.Yes
Colphene FR GR
Yes
Yes
Yes
.µ;� ?t'r � �::.
No
Yes
Yes .
5.5.1 I"F.oam-0n Tile" is limited to use of. following Approved the adhesives / underlayment combinations.
Adhesive Florida Product Approval Underlayments
Dow TileBond'" . • FL22525 Lastobond TU HT ,
ICP Adhesives Polyset° AH-160 . FL6332 Lastobond TU. HT or Colphene. FR GR
5.6 Allowable Substrates:
5.6.1 Direct -Bond to Deck:
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH. PLY 40, Lastobond Shield_ HT, Lastobond Pro. HT-S,
EnviroShield, Lastobond TU HT, Lastobond Eaves Protection Sheet, Lastobond 195, Lastobond ECO, RESISTO
LB1236, Grip -Rite LEave & Valley Protector, RESISTO LB1244 or Lastobond Smooth Seal HT applied to:
➢ Plywood; ASTM D41 primed plywood; OSB; ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41 primed
Southern Yellow Pine; ASTiVI D41 primed structural concrete.
Colphene FR GR applied to:
➢ Plywood; MTM D41 primed plywood; ASTM D41 primed structural concrete:
Note:
➢ While not required over plywood, OSB or Southern Yellow Pinesubstrates, Soprema recommends priming.
with Elastocol Stick -or Elastocol 600c if the final roof cover is not slated for installation within 24 hours.
➢ Soprema requires tongue -and -groove board decking be covered with plywood.or OSB prior to installation of
the self -adhering underlayment.
5.6.2 Bond -to -Insulation:
Lastobond Shield, Lastobond Pro HT=N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT-S,
EnviroShield, Lastobond. TU HT, Lastobond Eaves Protection Sheet, Lastobond 195, Lastobond ECO, . RESISTO
L61236, Grip-Rite-Eave & Valley Protector, RESISTO LB1244, Lastobond Smooth.Seal HT or Colphene FR GR
applied to:.
➢ Dens Deck Prime; SECUROCK Gypsum -Fiber Roof Board..
For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum
requirements of the prepared roof covering manufacturer's Product Approval: For installations under foam -on
file systems (Lastobond TU HT only), insulation attachment shall be designed by a qualified design professional
1 and installed based on testing of the insulation/underlayment system in accordance with FM 4474, Appendix O,
Testing Application Standard.TAS 114, Appendix J or UL1807.
1 Re er to Tile Manufacturer's orAdhesive Manufacturer's. Florida Product Approval for Overturning Moment Resistance Performance.
NEMO ETC, LLC TEvaluation Report S18010.06.09--R12
Certificate) afAutharirallon #32455, 6x EDITION (2017) FBC NON-HVHZ EVALUATION FL2569 R14
Soprema Roof'Underlayments.' Revision 12:02/12/2018
Page 4 of 8
i
i
ONEMO fetc.
5.6.3 Bond to Mechanically Attached -Base Laver:.
Lastobond Shield, Lastobond Pro HT-N,.RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT-S,
EnviroShield, Lastobond TU HT, Lastobond Eaves Protection Sheet, Lastobond 195, Lastobond -ECO, RESISTO
LB1236, Grip -Rite Eave & Valley, .Protector, RESISTO -LB1244, 'LastobondSmooth Seal HT or Colphene FR GR
applied to .
ASTM D226, Type I or II felt; Sopra-G; Modified Sopra-G.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum
codified requirements. For installations under foam -on the systems (Lastobond TU HT only), base layer shall be
attached in. accordance. with FRSA/TRI April 2012 (04-12).
.5.6.4 .Wind Resistance for Underlayment Systems in Foam -On Tile.Aaolications: FRSA/TRI April 2012• (04-12) does not
address wind . uplift resistance 'of all underlayment systems beneath foam -on tile systems;" where the
underlayment forms, part of the load -path. ' The following wind uplift limitations apply to underlayment systems
that are not addressed in FRSA/TRI April 2012 (04-12) and are used: in foam -on the applications. Maximum
Design. Pressure, is the, result of testing. for wind. load resistance based on.allowable wind loads, and'reflects the
ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied).
Refer to FRSA/TRI April 2012 (04-12) or FBC 1609 for determination of'design wind pressures. -
41 Maximum Design. Pressure = 45.0 DSf:"
.Deck: Min.. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: (Optional) Elastocol Stick, Elastocol 600c or RESISTO EXTERIOR PRIMER
Underlayment:. - Lastobond TU HT or Colphene FR GR; self -adhered.
# Maximum Design Pressure =-67.5 Dsf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: Elastocol600c
Underlayment: Lastobond.TU HT or Colphene FR GR, self -adhered.
#3 Maximum Design Pressure = -150.0 psf:
Deck: Min. 15/32-inch APA-rated BCX .plywood (may .be ,installed -C-side up) to meet project
requirements to satisfaction of Authority Having Jurisdiction.,
Deck Preparation: Plywood shall be thoroughly'cleaned to remove dust and debris.that may inhibit adhesion. All
sheathing fasteners shall be ,driven flush with the surface._ All sharp splinters and wood
projections shall be removed/sanded. '
Primer: (Optional) RESISTO EXTERIOR PRIMER
Underlayment: Lastobond TU HT, self -adhered, shall be thoroughly roll using hand roller and/or weighted
roller to ensure there are no voids, and ensure there are no voids/bridging at side and end -
laps.
#4 Maximum Design Pressure = -60.0 psf:
Deck: -Min. 19/32-inch plywood to meet project-requirerrients to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Sopra-G or Modified Sopra-G mechanically attached with nails (FBC.1517.5.1) and tin caps (FBC
1517.5.2) spaced. 6-inch o.c. at the 44nch laps and 6-inch o.c.'in three (3), equally spaced rows'
in the center of the sheet.
Underlayment: Lastobond TU HT or Colphene FR GR, self -adhered
5.6.4.1 All other direct -deck, adhered, Soprema underlayment systems beneath foam -:on tile systems carry a Maximum
Design Pressure of -45 'psf.
NEMO ETC, LLC Evaluation Report 518010.06.09-11112
certiJrCate ofAuthori:ation N32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL2569-11114
soprema'Roof Underlayments. Revision 12:02/12/2018
Page 5 of 8
NEMO I etc.
5.6.4.2 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet or
exceed that required under FRSA/TRI April 2012 (04-12), Appendix A, Table 1A.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design
pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an attachment
density designed by a. qualified design professional to resist the elevated pressure criteria. Commonly used
methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117.
Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention
Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements.
5.7 Exposure Limitations:
Lastobond Eaves Protection Sheet, Lastobond 19S,Lastobond Eco, Lastobond Smooth Seal HT; RESISTO 1.61236,
Grip -Rite .Eave & Valley Protector or RESISTO LB1244 shall not be left exposed for longer than 30-days after
installation.
Lastobond Shield; Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT or Lastobond Pro HT-
S, EnviroShield shall not be left exposed for longer than 90-days after installation.
Lastobond TU HT or Colphene FIR GR shall not be left exposed for longer than 180-days after installation.
5.8 Tile Slippage Limitations (TAS 103 per FRSA/TRI April 2012 (04-12)):
When loading roof tiles on the underlayment in direct -deck tile assemblies, the maximum roof slope shall be as
follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles.
TABLE
2: TILE SLIPPAGE LIMITATIONS FOR
DIRECT -DECK TILE INSTALLATIONS
Uliderlayment :
•
Tile Profile
Staging Method
Maximum.
Slope
Flat
Max:10-tile stack
6:12
Lugged
Max.10-tile stack
5:12
Max.10-tile stack (bottom 2-tile stack
shall be inverted, followed by 8 tiles high 6:12
on slope, as shown below)
Lastobond TU HT
Lugged
Max. 10-tile stack 5:12
Colphene FIR GR
Flat
Lugged
Max. 30-tile stack 6:12
NEMO ETC; LLC Evaluation Report S18010.06.09-R32
cerdflcate ofaathotizaUan a32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL2569-R14
Soprema Roof Underlayments Revision 12:02/12/2018
Page 6 of 9
ONEMO etc.6. INSTALLATION:
6,1 Soprema Roof Underlayments shall be installed in accordance with'Soprema published installation requirements
subject to the Limitations set forth in Section 5 herein -and the specifics. noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep .the substrate thoroughly to
remove any dust and debris prior to application; and prime the substrate with Elastocol Stick, Elastocol 600c or
RESISTO EXTERIOR PRIMER. (if applicable). .
6.3 Lastobond TU HT, .Lastobond Shield;: L'astobond :Pro:,HT-N, RESISTO SA SMOOTH PLY 40, Lastobond :Shield HT;
Lastobond. Pro ,HT=S, EnviroShi0d,114AObond;64es Protection Sheet, Lastobond 195,1astobond Eco; Lastobond
Smooth Seal HT, RESISTO L61236;:Grip-Rite Eave & Valley Protector, RESISTO161244.or Ci 1phene FR'GR:
6.3.1 1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for
the type of prepared roof covering to be installed:
6.3.2 Non-Tile'Applications:
While priming is optional, Soprema recommends priming with Elastocol, Stick, Elastocol 600c orRESISTO. EXTERIOR
PRIMER if the final roof cover is not slated for installation within 24 hours.
Apply sheet parallel to the roof edge. Roll out approxiMately 10 ft of membrane and peel back the first 3 ft of
release film.
Adhere the exposed part to the substrate and unroll the remaining membrane as far as possible.
Once the entire length.of membrane is in place, peel -off the release film diagonally while holding the membrane
tight. Firmly roll the membrane Into place to achieve'a bond.
Horizontal seams should be M'inimum.3-inches, configured to shed water. Vertical seams should be 6-inches and''
staggered not less than 2-ft from vertical seams in the course -below. All over -granule end -laps shall be sealed
using either heat -welding or hot air. welding techniques.
When installing at slopes above 8:12, Soprema recommends back -nailing in the overlap area, at the top of the
sheet at 12-inch o.c.
For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths. Peel the release paper and center sheet over
valley or ridge. Drape and press sheet into place, working from the. center of the valley or ridge in each direction.
,For valleys, apply the sheet starting at the lowest point and.work upward..
6.3.3 Tile Applications (Lastobond TLI HT or Colphene FR GR only):
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions
noted above as a guideline.
For foam -on tile applications, reference is made to Section' 5.6.4 herein for wind resistance limitations that fall
outside the scope of FRSA/TRI April 2012 (04-12).
Tile shall be loaded and staged in a manner that prevents the slippage and/or damage.to. the underlayment. See
(Table 2 herein, and Soprema published requirements for tile staging.
NEMO ETC,
required. by t
s product.
#32455
Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
Evaluation Report S18010.06.09-1112
6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL2569-R14
Soprema Roof Underlayments. Revision 12:02/12/20ig
Page 7 of 8
OMEMO etc.
8. PLANTS:
Contact the noted QA agency for information on. product .locations covered for F.A.C. 61G20-3 QA requirements.
The following plants have qualified products under their respective physical properties specifications.
Plant
Specification
Products) ..
Lastobond Shield, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT,
Lastobond Pro HT-N, Lastobond Pro.HT-5, EnviroShield, Lastobond 195,
Drummondville,
Drumm
Drumm
ASTM D1970
Lastobond Eaves Protection Sheet, Lastobond Eco, Lastobond Smooth
QC(Canada)
Seal HT, RESISTO LB1236, PrimeSource Grip -Rite Eave & Valley
Protector; RESISTO. LB1244
ASTM D1970.& FRSA/TRI 04-12
Colphene FR GR
Lastobond 195, Lastobond Eaves Protection Sheet, Lastobond Eco,
Wadsworth, OH
ASTM D1970'
Lastobond Smooth Seal HT, RESISTO LB1236, PrimeSource Grip -Rite
Eave & Valley Protector, RESISTO LB1244
ASTM D1970 & FRSA/TRI 04-12
Lastobond TU HT; Colphene FR GR .
Lastobond 195, Lastobond Eaves Protection. Sheet,. Lastobond Eco;
Gulfport, MS
ASTM D1970
Lastobond Smooth Seal HT, RESISTO LB1236, PrimeSource Grip -Rite
Eave & Valley Protector, RESISTO LB1244 '
QUALITY
ULLLC—QUA9625;(314)-578-3406;-k.chancellor@us.ul.com
- END OF EVALUATION REPORT -
III
�I
I
NEMO ETC, LLC
[ertif)Cote Of Authorization.#32455
Evaluation Report S18010.06.09•R12
6T" EDITION (2017) FBC NON-HVH2 EVALUATION FL2569-R34
Soprema Roof Underlayments Revision 12: 02/12/1018
Page 8 of,8