Loading...
HomeMy WebLinkAboutLETTER - ROOFING SPECIFICATIONi I � Ar6hitec"t6nic Inc� October 30, 2018 ScANNEo y Saint Lucie County Building Department Sttvcie cou t Attn: Roof Permit Plan Review Y 2300 �lrglnla Avenue Ft. Pierce, FL 34982 Re: Roofing specification prepared for the St. Lucie County Building Dept. for the structure located at 106 SE Lucero Drive, Saint Lucie County; Florida Manufacturer: Polyglass USA Profile's: Modified Bitumen Roof System, FL #1654-R22, System #W-140 Code: FBC 2017; Sectiori 905 Wind Speed: 160 MPH; Ultimate Design Wind Speeds Exposlre: C Meantoof Height: 30' Maximum Pitch: 2/12 Minimum Required Design Pressure: Zone1: -31.46 Zone 2: -49.61 Zone3: -68.97 Maximum Uplift Pressure: -90 psf Base: SBS-SA (self- adhering) Ply Sheet: (Optional) SBS-SA, (self -adhering) SBS-TA, APP-TA Cap: SBS-SA, APP-SA, SBS-TA, APP-TA Roof Decking: Existing 5/8" plywood sheathing to be nailed w/8d x 2" ring shank @ 6" O.C. thru out zone 1, 4" O.C. perimeter, and 6" O.C. field zone 2, and 4" O.C. thru out zone 3. The above approved, as per Florida Building Code Compliance acceptances, 2017 Florida Building Code, and the Manufacturer's recommendations. 806 Delaware Avenue Tel: 772 460 7751 www.architectonicinc.com Fort Pierce, Florida 34950 Fax: 772 460 4244 FL Reg #AA26003348 1 of 1