HomeMy WebLinkAboutPRODUCT APPROVAL - ASPHALT SHINGLESel
Business & Professional Regulation
.
pr 1
'l
BCIS.Home I Log in I User Reglsbratkm
Hot Topia I Submit Surcharge Stais & Facts ; Publications FBC Staff I BCIS Site Map ; Links Search
a
Proct Approval'USER:
bipf
Public USeY
'. . • :
: .. . .....:
SSA�
. . ......`
P.roduct ar.Aooilaflo'Ser
.- . `+ • r.
-> ollcalon LlsAplration.Detail
VC
• FL•#
FL7006-R30 s Y
UCio.
1 Application Type:'.
Code Version ..
Revision CO
2017 Uhy
-Application Status "
Appibved
"Approved by DBPR. Approvals by DBPR shall be reviewed and ratified
by the POC and/or the Commission if necessary.
Comments' ...
" .'
Arch lved
❑
Product Manufacturer
IKO Industries Ltd
Address/Phone/Email
40 Hansen Road South
Brampton, NON -US L6W 3H4
(708)496-2800 Ext200
rmetzO01@tampabay.rr.com
I
Authorized Signature
Robert Metz
rmetzOOI@tampabay.rr.com
Technical Representative
Bob Metz
Address/Phone/Email
REMCO of Pinellas
456 Avila Circle NE
Saint Petersburg, FL 33703
(727) 776-5261
I
rmetzDO1@tampabay.rr.com
'
Quality Assurance Representative
Don Shaw
Address/Phone/Emali
IKO Industries LTD
120 Hay Rd.
Wilmington, DE.19808
(717) 579-6706
don.shaw@lko.com
Category
Roofing
Subcategory
Asphalt Shingles
Compliance Method
Certification Mark or Listing
Certification Agency
FM Approvals - CER
Validated By
Locke Bowden
R1 Validation Checklist - Hardcopy Received
Referenced Standard and Year (of Standard) Standard Year
ASTM D3161 modified to 110 mph 2016
ASTM D3462 2010
ASTM D7158 Class.H 2O11
ASTM E108 2011
Equivalence of Product Standards
Certified By
Product Approval Method Method 1 Option A
I
Date Submitted 10/08/2017
Date Validated 10/30/2017
Date Pending FBC Approval
Date Approved 11/01/2017
Summary of Products
FL #
Model, Number or Name
Description
7006.1
Cambridge, Cambridge HD,
Laminated architectural fiberglass asphalt shingle
Biltmore and Biltmore HD
manufactured at IKO's Kankakee, IL; Hawkesbury, Ont.;
Wilmington, DE; Sylacauga,AL and Toronto, Ont. plants
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: Yes
FL7006 RIO C CAC Letter - ASTM D316LIetter - (9-26-
2017) from FM.Ddf
Approved for use outside HVHZ: Yes
Impact Resistant. N/A
FL7006 RIO C CAC Letter - ASTM D3462 letter - (9-26-
20171.pdf
Design Pressure: N/A
Other:
FL7006 RIO C CAC Letter - ASTM E108 letter - (9-26-
'2017).12df
Quality Assurance Contract Expiration Date
12/31/2020
Installation Instructions
FL7006 RIO U. IKO-187-02-01 Letter - Installation
Instructions for FBC FL7006.odf
Verified By: Duc T Nguyen 65034
Created by Independent Third Party: No
Evaluation Reports
Created by Independent Third Party:
7006.2
Hip and Ridge 12 Cap
This Is a 12" x 12" fiberglass asphalt shingle used to cover
the hip and/or ridge of an asphalt shingle roof system
manufactured at IKO's Kankakee, IL, Toronto, Ont. and
Brampton, Ontario plants.
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: Yes
FL7006 RIO C CAC ASTM D 3462 - Shingle letter
Surveillance Audit Location - (6-28-2017) pdf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
FL7006 R10_ C CAC Letter - ASTM D3161 letter - (9-26-
2017) from FM.pdf
Design Pressure: N/A
Other:
FL7006 RIO C CAC Letter- ASTM D3462_letter -(9-26-
2 17).nd
FL7006 R10 C CAC Letter - ASTM E108 letter - (9-26-
20171.pdf
Quality Assurance Contract Expiration Date
12/31/2020
Installation Instructions
FL7006 RIO II Hin and Ridge Cap Shingle Installation
Instructions.odf
FL7006 RIO II IKO-187-02-01 Letter - Installation
Instructions for FBC FL7006,pdf
Verified By: Duc T Nguyen PE 65034
Created by Independent Third Party: No
Evaluation Reports
Created by Independent Third Party:
7006.3
Leading Edge Plus Asphalt Shingle
One piece fiberglass asphalt shingle used as a starter strip at
Starter Strip
the bottom of a roof system manufactured in Brampton and
Hawkesbury, Ontario plants
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: Yes
FL7006 RIO C CAC Letter - ASTM D3161 letter - (9-26-
2017) from FM.odf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
FL7006 RIO C CAC Letter - ASTM 03462 letter - (9-26-
20171.odf
Design Pressure: N/A
Other:
FL7006 RIO C CAC Letter - ASTM E108 letter - (9-26-
2017). df
Quality Assurance Contract Expiration Date
12/31/2020
Installation Instructions
FL7006 RIO II IKO-187-02-01 Letter - Installation
Instructions for FBC FL7006.odf
FL7006 RIO II Roofing-Products-Leadina-Edge-Plus-
An pl lcatlon-EN (1). pdf
Verified By: Duc T Nguyen PE 65034
Created by Independent Third Party: No
Evaluation Reports
Created by Independent Third Party:
7006.4 Marathon Plus AR, Superglass Plus
3 tab fiberglass asphalt shingle manufactured at IKO's
AR
Brampton, Ontario, Hawkesbury Ont., Toronto, Ont.;
Sylacauga, AL and Kanakakee, IL plants
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: Yes
FL7006 R10 C CAC Letter - ASTM D3161 letter - (9-26-
Approved for use outside HVHZ: Yes
2017) from FM,Ddf
Impact Resistant: N/A
FL7006 910 C CAC Letter - ASTM D3462 letter - (9-26-
Design Pressure: N/A
2017).odf
Other:
FL7006 R10 C CAC Letter - ASTM E108 letter - (9 26-
2017).odf
Quality Assurance Contract Expiration Date
12/20/2020
Installation Instructions
FL7006 R30 II IKO-187-02-01 Letter - Installation
Instructions for FBC FL7006.pdf
Verified By: DucT Nguyen 65034
Created by Independent Third Party: No
Evaluation Reports
Created by Independent Third Party:
Back Next
Contact Us :: 2601 Blair Stone Road. Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida Is an AA/EEO employer. Copyright 2007-2013 State of Florida.:- Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic
mall to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275
(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide.the Department with an email address If they have one. The
emalts provided may be used for official communication with the licensee. Howeveremall addresses are public record: If you do not wish to supply a personal address,
please provide the Department with an email address which can be made available to the public To determine If you are a licensee under Chapter 455, F.S., please
i dick here .
Product Approval Accepts;
® ® ®
Credit Card
Safe
1
Re:
CONSTRUCTION -MATERIALS
TECHNOLOGIES
)ber 27, 2017
D'�N�ED
Industries, 'Ltd
Hay Rd. St COIJ
iington, DE .19809 MY
FL7006
PRI (Construction Materials Technologies has completed a technical review and attached sealed shingle
instructions in compliance the 2017 Florida. Building Code.
This review was completed based on the receipt of following evidence from IKO Industries; Ltd:
Il) IKO Shingle Application Instructions — 3-Tab Shingles
(EN-3Tab_Appins_8AGXEFS-2012-11_reformatted 2013-02-rev07/13-Florida)
2) IKO Laminated Shingles Application Instructions
(EN -Laminated Appins_8TTEFS-2012-04 reformatted 2013-02-rev07/13-Florida)
IKO Hip and Ridge 12 Application Instructions
(EN-HipandRidge12 - 3HRTri-2013-08_reformatted 2013-08)
4) ,IKO Leading Edge Plus Shingle Application Instructions
(EN-3LEP-Tri-2012-06_reformatted 2013-03)
5) ASTM D3161 Test Report (FM Approvals Project No. 3040947)
The attached instructions should be used in conjunction with the published manufacturer's application
instructions and applicable code. In the event the instructions conflict, these instructions shall govern.
Statement of Independence: PRI Construction Materials Technologies and/or Duc T. Nguyen, FL P.E. do not
have nor plan to acquire a financial interest in any company manufacturing or distributing products for which.
the test reports are issued.
C Signed:
BradGriybo sk 'DucT. u en
Managing rector Florida Rdg _ ered Professional Engineer
P.E. Number: 65034
October 27, 2017 Date: October 27, 2017
A). IKO Shingle Application Instructions - 3-Tab
B) IKO ,Laminated Shingles Application Instructions
C) IKO Hip and Ridge 12 Application Instructions
D). IKO Leading Edge Plus Application Instructions
IKO-1$7-02-01
PRI Constmction M6dals Technologies, LLC. 6412 Badger Drive Tampa, FL 33610 Tel: 813-621-5777 Fax: 813.621-WO e-mail. materialstesting@pricmtcom Web$ile: htip:/Mnxw.pdcmtcam
1/—'1
IKO'1
Installation Instructions for
Asphalt Shingles
Page 2 of 5
IKO. Shingle Application Instructions — 3-Tab Shingles
(ASTM D3161, Class F - IKO Marathon 25 AR and CRC Superglass M25AR)
THESE INSTRUCTIONS SHALL BE USED IN CONJUCTION WITH IKO'S PUBLISHED
CATION INSTRUCTIONS AND THE APPLICABLE CODE. IN THE EVENT THE INSTRUCTION
LICT, THESE'INSTRUCTIONS WILL GOVERN.
DECK: Solidlysheathed and fastened deck conforming to 2017 FBC:
UNDERLAYMENT: Applied in accordance with building code requirements. For areas where the roof slope is
less than 4 per foot down to 2" per foot, use 2 layers of underlayment conforming to' building code
req l irements, the first sheet overlapping the eave protection by 19", followed by full 36" widths overlapping
each preceding course by 19" or other Approved underlayments in accordance with the qualified application
instructions. For 'areas where the roof. slope is 4 per foot or greater, cover the deck with one ply of
and?rlayment laid parallel to the eaves, with 2 horizontal laps and V end laps. Apply metal drip edges on top
Of any underlay along rake edges ,and directly to the deck along eaves in accordance with building code
NAILING: Use galvanized (zinc coated) roofing nails, 11 or 12 gauge, with at least 3/8" diameter heads, long
enough to penetrate through plywood or 3/4" into boards. Use 4 nails per shingle placed 6-1/8" above the butt
edge, approx. 1" and 13" from each end and 1/2" above each cutout. Drive nails straight so that nail head is
flush with, but not cutting into shingle. surface.
NAILING ON STEEP SLOPES: For steep slopes of 21" per foot (60°) or more, use 6 nails per shingle placed
as shown below. Ensure that no nail is within 2" of a joint/cutout of the underlying shingle. Seal down each .
shingle at time of application -with three 1" diameter (approx. size and thickness of a quarter) spots of asphalt
plastic cement placed under the shingle 2" above the bottom edge and equally spaced along the shingle.
Apply plastic cement in moderation_ since excessive amounts may cause blistering. CAUTION: Shingles
sho Id seal to the underlying course when the factory applied asphalt sealant is suffibiently.warmed by the
heat�of direct sunlight.
EXPOSURE: Installed shingles shall have a maximum average exposure of 5-5/8"
PM Consthlctlon Materials Technologies, LLC. 6412 Badger Drive Tampa, FL 33610
STEEP SLOPES
I� I• «
SEALING STRIP
NAILS
'0ORABOVETHE SEALING STRIP
Tel: 813.621-m 7 Fax: 813.621-5840 e-mail: m&.dalstestlng@pdcmt.com .WebSite: htlpYAvww.pdcmtcoM
ation Instructions for
ilt Shingles
3of5
IKO Laminated Shingles Application, Instructions.
(ASTM D3161, .Class F — Cambridge, Cambridge HD, and CRC Biltmore AR)
THESE INSTRUCTIONS SHALL BE USED IN .CONJUCTION WITH IKO'S PUBLISHED
ATION INSTRUCTIONS AND THE APPLICABLE CODE. IN THE EVENT THE INSTRUCTION
CT, THESE INSTRUCTIONS WILL GOVERN.
DECK: Solidly sheathed and fastened deck conforming to 2017 FBC.
UNDERLAYMENT: Applied in accordance with building code requirements. For areas where the roof slope is
I ess) than 4 per foot down to 2" per foot, use 2 layers of underlayment conforming to building code
requirements, the first sheet -overlapping the eave protection by.19", followed by full 36" widths overlapping
each preceding course by 19" or other Approved underlayments in accordance with the qualified application
inst suctions. Foi areas where the roof slope is 4" per foot or greater, cover the deck with one ply of
underlayment laid parallel to the eaves, with 2" horizontal laps and 4" end laps. Apply metal drip edges on top
of arty underlay along rake edges and directly to the deck along eaves in accordance with building code
NAILING: Use galvanized (zinc coated) roofing nails, 11 or 12 gauge, with at least 3/8" diameter heads, long
enough to penetrate through plywood or 3/4" into boards. Use 4 nails per shingle placed in the nail line 7-3/8"
below the top edge,'' pprox. 1" and 13" in from each end. Drive nails straight so that nail head is flush with,
-but riot cutting into shingle. surface.
NAILING ON STEEP SLOPES: For steep slopes of 21"per foot (600) or more, use 6 nails per shingle placed
as shown below: Ensure that no nail is within 2" of a jointicutout of.the underlying shingle. Seal down each
shingle at time of application with three 1" diameter.(approx. size and thickness of a quarter)'spots of asphalt
plastic cement placed under the shingle 2" above the bottom edge and equally spaced' along the shingle.
Apply plastic cement in moderation since excessive amounts may cause blistering. CAUTION, Shingles'
sho Id seal to the underlying course when the.factory applied asphalt sealant is sufficiently warmed by the
heatIof direct sunlight.
6
Installed shinglesshall have a maximum average exposure of 5-7/8".
4
7 3/a'
NAIL LINE
NAILING = STEEP SLOPES APPLICATION_
Use she nails as shown.
r r.F1 L.
CEMENT
APPLICATION REQUIRES THAT THE NAILS PENETRATE BOTH THE OVERLAY AND UNDERLAY PORTIONS OFTHE SHINGLE
PRI construction M I ledalsTechnotogies, LLC. 6412 Badger Drive Tampa, FL 33510 Tel: 613.621-5'm Fax: 813-0-5840 e-mail: maladalstesting&rlcmtcom WetSite: hitp:/Avww.pdcmt.com
ation Instructions for
3It Shingles
4of5
IKO Hip and Ridge 12 Application. Instructions
(ASTM D3161, Class F — IKO Hip and Ridge 12)
THESE INSTRUCTIONS SHALL BE USED IN CONJUCTION WITH IKO'S PUBLISHED
ATION INSTRUCTIONS AND. THE APPLICABLE CODE. IN THE EVENT THE INSTRUCTION
CT, THESE INSTRUCTIONS WILL GOVERN.
hip and ridge shingles into thirds, using the perforation marks as a cutting guide. These, shingles are
gned for a 51/8" (130 mm) exposure. (For a neater appearance, the top of each side of each piece has
i factory trimmed on a 1" (25 mm) taper (see drawing). Bend each piece over the hip or ridge, and nail 5
(143 mm) above the butt edge 1" (25 mm) in from each edge, exposing each piece 51/8" (130 mm).
y hip pieces starting at the lower end of the hip, working up toward the ridge. On hip roofs, apply ridge
es starting at each end, meeting'in the middle. On gable roofs, apply ridge pieces starting at the end
)site to the prevailing wind' direction and continue to the other end. Note: To obtain a three-dimensional
;t, (which is recommended, but not required), apply hip and ridge shingles double thickness by stacking 2
es on top of one another, the lower piece extending about 3/4" (19 mm) further than the top piece (see
ram). The final shingle should be in cement, and the exposed nail heads of the final shingle should be
:red, with cement. Prior to application in cold weather, storing the shingles in a heated area will allow for
er bending..
SHI
ALL;
TO
E: SHINGLES MUST BE APPLIED PROPERLY. THEY ARE DESIGNED FOR USE AS HIP AND RIDGE
IGLES ONLY; AND SHOULD NOT BE USED FOR ANY OTHER APPLICATIONS. WE ASSUME NO
PONSIBILITY FOR LEAKS OR DEFECTS RESULTING FROM POOR APPLICATION OR FAILURE TO
PERLY PREPARE THE SURFACE TO BE ROOFED OVER, OR FAILURE TO PROVIDE PROPER
TILATION IN ACCORDANCE WITH MINIMUM PROPERTY STANDARDS REQUIREMENTS. REVIEW
4PPLICABLE BUILDING CODES, MINIMUM PROPERTY STANDARDS, AND REQUIREMENTS PRIOR
1PPLYING THESE SHINGLES USING THESE APPLICATION INSTRUCTIONS. - -
,-
ram"
TAM CVr
PRI Construction Materials Technologies, LLC. 6412 Badger Drive Tampa, FL 33610 Tel: 813.621-07 Fax: 813.621-5M a -mail: matedalstesdng@pricmLcwm Web&te: httpJAvww.pdcmtcom
lKOI
Installation Instructions for
Asphalt Shingles
Page 5 of 5
I
IKO.Leading Edge Plus Application Instructions
(ASTNI D3161, Class F — IKO Leading Edge Plus)
NOTE: THESE INSTRUCTIONS SHALL BE USED IN CONJUCTION WITH IKO'S PUBLISHED
APPLICATION INSTRUCTIONS AND THE APPLICABLE CODE. IN THE EVENT. THE INSTRUCTION
CONFLICT, THESE INSTRUCTIONS WILL GOVERN.
1. Apply any underlayment, eave protection, valley flashings, or drip edges to roof deck as required.
2. Each 39 3/8" x 131/4" (1000 mm x 336 mm) IKO Leading Edge Plus strip is perforated lengthwise for
separation into two (2) shingles. Take one IKO Leading Edge Plus strip and fold flat at perforation to
separate.
3. Take one of the separated shingles 39 3/8"x 6 5/8" (1000 mm x 168 mm) and remove approximately
20"(500 mm). Install this shingle on the lower left corner of the roof deck, granule side up, with the
factory installed sealant adjacent to the eaves. The shingle should overhang the rake edge and eaves
by a nominal 1/4" (6 mm) minimum. Fasten the shingle to the roof deck with nails located 3" to 4" (75
mm to 100 mm) from the eave edge and 1" (25 mm) in from each end.
4. Take the leftover 20" (500 mm) piece shingle. Rotate the piece and align it vertically up the rake edge
with the factory installed sealant adjacent to the outer edge of the roof. The shingle should overhang
the rake edge by a nominal 1/4' (6 mm) minimum. Fasten the shingle to the roof deck with fasteners
located 3" to 4" (75 mm to 100 mm) from the rake edge and 1" (25 mm) in from each end.
15. Repeat Steps 3 — 4 for the right lower corner of the roof deck_
NAILING: Use galvanized (zinc coated) roofing nails, 11 or 12 gauge, with at least
3/8" (9 mm) diameter heads, long enough to penetrate through plywood or 3/4" (20
mm). into boards. Use 4 nails per shingle placed 3" to 4" (75 mm to 100 mm) from
the pave edge and approximately 1" and 13" (25 mm and 330 mm) in from each end.
6. Apply full-length IKO Leading Edge Plus shingles to the remaining eave edges of the roof deck. Install
the shingles. granule side up with the factory applied sealant adjacent to the eaves. The shingles
should overhang the rake edge and eaves by a nominal 1/4" (6 mm) minimum. Fasten the shingles to
the roof deck with nails located 3" to 4" (75 mm to 100 mm) from the eave edge, 4 nails per shingle.
n. Apply roof shingles as per the instructions printed on each product's package. Make certain the first
course of field shingle lies flush with the edgesof the fastened IKO Leading Edge Plus. In this way,
the sealant on the IKO Leading Edge Plus shingles will adhere to the first -course field shingles and
help keep them from lifting in high winds.
PRI.Constmction Materials Technologies, LLC. 6412 Badger Drive Tampa, FL33610 Tel:813.621.5777 Fax:813-621-5840 e-mail: materialstesling@pricmtcom WebSde: hffp:1Avww.pricmtoom