Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutPRODUCT APPROVAL - MODIFIED BITUMENProfessionalBusiness & Regulation,
°5"+
BCLS Home ! Log In I User Registration I Hot Topics I Submit Surcharge I Soots & Facts I Publications
I Contact Us I BOS Site Map . Links Search
Florida 1
rova
Product Appl
P
USER: .Us err
Product Approval Menu > Product or Anpllcatlon Search > Application List > Application Detail
FL #
FL1654-1122
Application Type
Revision
Code Version
2017
/�
Application Status
Approved
-9Cyq/`/
ED
Sty D N
),
Comments
�/C�
Archived
❑
County
Product Manufacturer
POLYGLASS USA
Address/Phone/Small
1111 W. Newport Center Drive
Deerfield Beach, FL 33442
(954)233-1330 Ext242
malpert@polyglass.com
Authorized Signature
Maury Alpert
malpert@polyglass.com
Technical Representative
Maury Alpert
Address/Phone/Email
1111 W. Newport Center Drive
Deerfield Beach, FL 33442
(912)429-8610
MAlpert@polyglass.com
Quality Assurance Representative
Ariel Lender
Address/Phone/Email
1111 W. Newport Center Drive
Deerfield Beach, FL 33442
(954)233-1230
ALender@polygiass.com
Category
Roofing
Subcategory
od4fed���B�ttimen`ftoof stem
Compliance Method
Evaluation Report from a Florida
Registered Architect or a Licensed Florida
Professional Engineer
❑ Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed
Robert Nleminen
the Evaluation Report
Florida License
PE-59166
Quality Assurance Entity
UL LLC
Quality Assurance Contract Expiration Date
09/13/2021
Validated By
John W. Knezevich, PE
© Validation Checklist - Hardcopy Received
Certificate of Independence
FL1654 R22 COI 2017 01 COI
Nleminen odf
Referenced Standard and Year (of Standard)
Standard
Year
ASTM D6162
2008
ASTM D6163
2008
ASTM D6164
2011
ASTM D6222
2011
ASTM D6509
2009
FM 4470
2012
FM 4474
2011
i
UL 1897
2012
{
Equivalence of Product Standards.
Certified By
Sections from the Code
Product Approval.Method
Method 1 Option D
1
Date Submitted
,
09/14/2017
Date Validated
09/IS/2017
Date Pending FBC Approval
09/22/2017
Date Approved
12112/2017
Date Revised
20/08/2018
Sumpm of Products
FL #
Model, Number. or Name '
Description
o Y
1 en Roo ys em
. �,X-A M. vit 'sy t m5
Limits of Use
Installation Instructions
Approved for use In HVHZ: No
FL3654 R22 II 20i7 09 FINAL Ai ER POLYGLASS 'MODBIT FL1654-
R22,odF .
Approved for use outside HVHZ:'Yes
'Impact Resistant: N/A
Verified By: Robert Nieminen PE-59166
Design Pressure: +N/A/-622.5
Created by Independent Third Party: Yes
Other: 1.) The design pressure in this application''
Evaluation Reports
relates to one particular assembly over concrete
F t 654 R22 AF 2017 09 FINAL ER POLYG ASS MODBIT FL1654-
R22.odf
deck. Refer to the ER Appendix for other systems.'
and. deck.types. 2:) Refer to ER, Section 5 for other
Created by Independent Third Party: Yes
Limits of Use:
Baek .
Contact Us :: 2601 Blair Stone Read. Tallahassee FL 32399 Phone: 850-407-1824
The State of Florida Is an AA/EEO employer. Coovriaht 2007-2013 State of Florida. ;: Privacy Statement :: Accessibility Statement :: RePond Statement
Under Florida law, emall'addresses are public retards. If you do not,want your e-mail address released In response to a publlarecords request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S: must provide the Department with an email address Ifthey have one. The emalls
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, F.S., please click here .
product Approval Accepts:
Credit Card
Safe
\I � RINIIY 10
Table
Deck
Application -
Type
Description
Page
1A
Wood
New or Reroof (Tear -Off)
A-1:
Bonded Insulation, Bonded Roof Cover
5
113-1
Wood
New or Reroof (Tear -Off)
A-2 .
Mech. Attached Anchor Sheet; Bonded Insulation, Bonded Roof Cover
5-9 .
iB-2
Wood
New, Reroof (Tear -Oft) or Recover
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
10-11
'1C
Wood
New, Reroof (Tear -Off) or Recover
B
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
11
1D
Wood.
New, Reroof (Tear -Oft) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
12-13 -
1E •
Wood
New, Reroof (Tear-Off).or Recover
D
Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover
14-15
IF-1
Wood
New or Reroof (Tear -Off) _
E ,
Non -Insulated, Mech. Attached Base Sheet (nails), Bonded Roof Cover .
16-18
iF-2
Wood
New, Reroof (Tear -Off) or Recover
E
Non -Insulated; Mech. Attached Base Sheet (screws & plates), Bonded Roof Cover,
19-21
1G
Wood -
New or Reroof (Tear -Off)
:.. F ... .:
Non-insulated;:Bonded Roof Cover .
21
2A
Steel or Structural concrete
New, Reroof (fear -Off) or Recover
B
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover' •
22-24
} 28
Steel or Structural concrete
New, Reroof (Tear -Off) or Recover
C
Mech.. Attached Insulation, Bonded Roof Cover
25-28
2C
Steel or Structural concrete
New, Reroof (Tear -Off) or Recover
D
Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover
29-31
3A
Structural concrete
New or Reroof (Tear -Off)
A-1
Bonded insulation, Bonded Roof Cover .
. . 32-40
3B
Structural concrete
New or Reroof (Tear -Off)
F
Non-lnsulated,.Bonded Roof Cover
40
4A
LWIC
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover "
41-42
4B
LWIC
New or Reroof (Tear -off) ..
A-2
Mech. Attached Anchor Sheet Bonded Insulation, Bonded Roof Cover
43 ..
4C
LWIC
New or Reroof {Tear=Off) '
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
44-46
SA
CWF
New or Reroof (Tear -Oft)
A-1
Bonded Insulation, Bonded Roof.Cover
47 .
5B
CWF
New, Reroof (Tear Off) or Recover
A-2
Mech. Attached Anchor Sheet; Bonded Insulation, Bonded Roof Cover
46
SC
CWF
New, Reroof (Tear -Off) or Recover
B
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
49
5D
CWF
New, Reroof (Tear -Off) or Recover
C
Mech. At Insulation, Bonded Roof Cover
49
SE
CWF
New, Reroof (Tear -Off) or Recover
E
Non -Insulated, Mech: Attached. Base Sheet, Bonded Roof Cover
49
6A.
Gypsum
Reroof (Tear -Off)
A-1
Bonded Insulation; Bonded Roof Cover
50-52
6B
Gypsum
Reroof (Tear. -Off) or Recover
A-2.
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
. . 52
6C -
Gypsum
Reroof (Tear -Off) or Recover
C
Mech. Attached insulation, Bonded Roof Cover
53
6D
Gypsum.
Reroof (Tear-OM.or Recover
E
Non -Insulated; Mech. Attached -Base Sheet, Bonded Roof Cover
53.
7A
Various
Recover
A-1
Bonded Insulation, Bonded Roof Cover
54-58.
7B
Various
Recover
"F
Non -Insulated, Bonded Base Sheet, Bonded Roaf Cover
S8
The following notes apply to the systems outlined herein:'
1. The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction:
Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation.
2. Insulation/ base sheet fasteners shall be of sufficient length for the following deck engagement:
D Wood: Minlmurn 0.75-inch penetration,
➢ Steel: Minimum 0.75-Inch penetration and engage the top flute of the steel deck.
➢ Structural concrete: Minimum 1-Inch embedment into pilot hole in accordance with fastener manufacturer's published installation instructions.
3. unless otherwise noted, Insulation may be any one layer or combination of polylsocyanurate, polystyrene, wood fiberboard, perlite, gypsum -based roof board or mineral -wool roof board that meets the CIA
requirements of F.A.C. Rule 61G2D-3 and is documented as meeting FBC 1505.1 and, for foam plastic,TBC Chapter 26, when Installed with the roof cover.
Exterior Research and Design, LLC: d/b/a Trinky{ERD - Evaluation Report P9290.02.08-1120 for FL184-02-
Certificate of Authorization #9503 67N EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20i 09/12/2017
Prepared by: Robert Nieminen, PE-59166 Polyglass Modifled Bitumen Roof. Systems; (570) 384-1230 Appendix 1, Page 1 of 58
�l TRINITY I ERD
15. 'Unless otherwise noted, refer to the following references for bonded base, ply or cap sheet applications.
.. _. ' .....,.. _,.z .,.... ....e:, ., .TBFlLEi.POLYGtA6S - -
Reference
Layer
Material.
Application
BP -AA
Base Ply
One or More piles Polyglass G2 Base; FBC Approved ASTM D4601, Type 11
Hot Asphalt at 2040
Ply
One or more plies Polyglass Ply IV, Polyglass Ply VI, FBC Approved ASTM D2178, Type IV or VI
(Base and Ply sheets, Asphalt-
Ibs/square
Applied)
Note:
Asphalt -applied sheets or Insulation shall not be applied to poly- !m surfaced membranes.
Base Ply
One ply Elastobase (sand/sand), Elastoflex V, Elastoflex 56, Elastoflex S6 Type II, Polyglass HT Base 650
"
SBS-CA1
Cap Ply
Elastoflex VG, Elastoflex VG FR, Elastoflex S6, Elastoflex S6 Type 11, Elastoflex S6 G, Elastoflex S6 G FR, Elastoshleld TS-G, Elastoshield
P6350 at 1.5-2.0
gal/square
TS-G FR. Polyfresko G SBS (sand -backed), Polyfresko G SBS FR sand -backed)
Base Ply
One ply Elastobase (sand/sand), Elastoflex V, Elastoflex S6, Elastoflex S6 Type II
Polyplus 35 at 1.5-2.0
Cap Ply
Elastoflex VG, Elastoflex VG FR, Elastoflex S6, Elastoflex S6 Type ll, Elastoflex S6 G, Elastoflex S6 G Fit, Elastoshield Ts-G, Elastoshield
SBS-CA2
TS-G FR, Polyfresko G SBS (sand -backed), Polyfresko G SBS FR (sand-backed)gal/square
Base Ply or Ply
,.One or more.plles Elastobase (sand/sand or poly/sand), Elastobase P. (sand/sand or poly/sand), Elastoflex V, Elastoflex S6, Elastoflex
S6 Type 11, Polyglass HT Base 650
SBS-AA
(SBS, Asphalt -Applied)
Cap Ply
Elastoflex V, Elastoflex VG, Elastoflex VG FR, Elastoflex S6, Elastoflex S6 Type 11, Elastoflex S6 G, Elastoflefx S6 G FR, Elastoshleld TS-G,
Hot Asphalt at 20-40
Ibs/square
Elastoshield TS-G FR, Polyfresko G SBS (sand -backed), Polyfresko G SBS FR (sand -backed) ."
Note:
Asphalt -a piled sheets or- Insulation shall not be ap lled topoly-jllm surfaced membranes.
Base Ply or Ply
or more'piles Elastobase (sand/poly), Elastobase (poly/poly), Elastoflex V, Elastoflex S5, Elastoflex S6 Type li, Polyglass HT Base
SBS-TA
650
(SBS, Torch -Applied)
Cap Ply
Elastoflex V, Elastoflex VG, Elastoflex VG FR, Elastoflex S6, Elastoflex S6Type II, ElastoflexS6 G, ElastoflexS6 G FR, ElastoshleldTS-G,
Torch -Applied
Elastoshield TS-G FR, Polyfresko.G SBS oly-film backed), Polyfresko G SBS FR. (poly -film backed)
Base Ply
.One or more piles Elastoflex SA V Base, Elastoflex SA V FR Base, Elastoflex SA V Plus, Elastoflex SA V Plus FR.
SBS-SA
Cap Ply
" Elastoflex SA P, Elastoflex SA P FR, P.ol reflect
Self -Adhering
Note:
Unless otherwise noted, permissible membrane substrates for SBS-SA are 11mited to the SBS-SA Base Plyapdans herein,
(SBS, Self -Adhering)
Elastobase (poly/sand) or Elastobase (poi / o ).
APO -CAI.
Cap Ply
Polyflex G FR .
PG350 at 15- 2.0
gal/square
APP-TA
Base Ply or Ply
One or more piles Polyglass APP Base, Polyflex, Polybond
Torch -Applied
Cap E!L
Polyflex, Polyflex G, Polyflex G FR, Polybond,.Polybond G, Polyfresko G, Polyfresko G FR
(APP, Torch -Applied)
Cap Ply
Polyflex SA P, Polyflex SA P FR, Polyfresko G SA, Polykool
APP-SA
(APP, Self -Adhering)
Self -Adhering
Note:
Unless otherwise noted, permissible membrane substrates forAPP-SA are limited to the SBS :SA Base Ply optlons herein,
Vastobase (poly/sand) orElastobase (poly/poly).
16. Any of the following FBC Approved coatings may be applied to the top roof membrane without adverse effect on the.system wind load performance.
). associated with coating usage.
D
- PG200 Non Fibered Roof Coating;
D
P6300 Fibered Roof Coating;
➢
P6600 Non-Fibered Aluminum Roof Coating;
➢
PG65D Fibered Aluminum Roof Coating;
D
PG700 High Quality Elastomerlc Roof Coating or KM Acryl 25;
D
PG7000S (Quick Set) High Quality Elastomerlc Roof Coating or KM Acryl 2S-QS (for granule -surfaced APP or SBS only);
➢
PG800 Asphalt Emulsion Roof Coating;
➢
Polyplus 60 Premium Non-Fibered Aluminum Roof Coating;
➢
Polyplus 65 Premium Fibered Aluminum Roof Coating;
D
Polybrite 70 Premium Grade Elastomerlc Roof Coating or KM Acryl 25;
➢
Polybrite 700S (Quick Set) Premium Grade Elastomerlc Roof Coating or KM Acryl IS-QS (for granule -surfaced APP or SBS only);
➢
Polybrite90 High Solids Silicone Roof Coating or Polybrite 95 Silicone Roof Coating.
Refer to current Roofing Materials Directory for fire ratings
Exterior Research and Design, U.C. d/b/a T &WIERD Evaluation Report P9290.02.08-1120 for FLIGWR22
Certificate of Authorization #9503 IP EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/12/2017
Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Appendix 1, Page 3 of 58
TRINITYJERD
V 'SH
System
Base Sheet
Roof Cover (Note 15)
MOP
No.
Deck (Note 1)
(PA
Type Fasten Attach
Base Ply Cap
W
Min. 19/32-
Elastobase, Elastobase P
Dekfast Hex (aka, Deld'ast PLT-H-2-7/8) with Dekfast #14
12-Inch o.c. In 44nch lap and 12-inch o.c. in two
SBS-SA
SBS-SA, APP-SA SBS-
-52.5*
W-136
Inch plywood
(poly -film top)
or Trufast 3" Metal Insulation Plate with Trufast HD
(2), equally spaced, staggered center rows
TA, APP-TA
Min. 19/32-
Elastobase, Elastobase P
Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #14
12-Inch o.c. In 4-Inch lap and 12-Inch o.c. in two
PoWexSABase
APP-TA
W-137
inch plywood
(poly -film top)
or Trufast 3" Metal Insulation Plate with Trufast HD
(2), equally spaced, staggered center rows
.-52.5*
W-138
Min. 19/32-
Elastobase, Elastobase P
OMG Flat Bottom Plates (square) with Roofgrlp #12
12-Inch o.c. in 4-inch lap and 12-Inch o.c. In two
SBS-SA
SBS-SA; APP-SA, SBS-
_60.0*
Inch plywood
(poly -film top)
1
(2), equally spaced, staggered center rows
TA, APP-TA
Min. 19/32-
Elastobase, Elastobase P
OMG Flat Bottom Plates (square) with Roofgrlp #22
1
12-inch o.c. In 4-Inch lap and 12-Inch o.c. In two
Polyflex SA Base
I
APP-TA
I
-60.0*
inch plywood
(poly -film top)
(2), equally spaced, staggered center rows
WOOD DECKS -C �NST X RUC -110MORE 00F(IE ldii)
0
g9v
System
Roof Cover (Note 15)
Joint Treatment
Base Ply
Ply
Cap Ply
No.
Deck (Note l)
Primer
Min. 15/32-
SBS SA
(Optional) SBS-SA, SBS-
SBS-SA, APP-SA, SBS-
W-140
inch plywood
None
None
TA, APP-TA
TA, APP-TA,
inc I
K All 100
Wilo-Rubp
None
P00954Bigg -----�f(Q'Ptt6hal)APP-
-90.0
W-142
Min; i 15/32-
P6100
None
SBS-SA
(Optional) SBS-SA, SBS-
SBS-SA, APP-SA, SBS-
-97-S
inch plywood
TA, APP-TA
TA, AP -
Min. 15/32-
.
Plywood joints are covered With 4-Inch wide strips of ElastoflexSAV Plus, rolled Into,
Elastoflex SA V Base or
(Optional) SBS-SA, SBS-
SBS-SA, APP-SA, SBS-
-97.5
W-143'
Inch plywood
nal) P6100
(Optional)
place to create continuous bond.
Elastoflex SA V FR Base
TA, APP-TA
TA, APP-TA
W . -144
Min. 15/32-
WB-3000
None
SBS-SA
(Optional)
SBS-SA, APP-SA, SBS-
TA, APP-TA
_105.0
inch plywood
Min. 15/3�2-
Plywood joints are covered with 4-Inch wide strips of EIastofIPxSA V Plus, rolled Into
Elastoflex SA V Plus or
(Optional) SBS-SA, SBS-
SBS-SA, APP-SA, SBS-
-135.0
W-145
Inch plywood
(Optional) PQ00
p
. .
place to create continuous bond.
EIastofIexSAVPlus FR
TA, APP-TA
TA, APP-TA
W-146
Min. 15/32-
(Optional) PGIOD
Plywood joints are covered with 4-Inch wide strips of ElastoflexSAV Plus, rolled Into
Polyflex SA Base
(Optional) APP-TA
APP-TA
-135.0
Inch plywood
place to create continuous bond.
Exterior Research and Design, LLC. d/b/a Trinity[ERD
Certificate ofAuthorization 495O3
Prepared by: Robert Nlemilnen, PE-59166
e" EDITION (2017) FBC NON-HVHZ EVALUATION
Polyglass Modified Bitumen Roof Systems; (570) 3WI230
Evaluation Report P9290.02.08-1120 for FU654-RZ2
Revision 20:09/12/2017
Appendix 1, Page 21 of 58