HomeMy WebLinkAboutOPTIONAL LOAD CALCULATIONr .
Optional Load Calculation
Heat Larger Than Air
OC) SF x 3VA Living Only
(2) Small appliance ckts @ 1500VA each
Refrigerator @ 1500
Refrigerator @ 1500P.
Freezer @ 1500 '
iF i 1� �.: zt y!
Washing Machine @ 1500
Dishwasher @ 1500 a ILA
Disposal @ 1500
Mini Sewer @ 1500 ST.LUCIE COUNTY
Clothes Dryer @ 5000 PLAN REVIEW
Range @ 12000
Water heater @ 4500 BLDG:
Fixed microwave @ 1500 DATE:
Vacuum @ 1500 ELEC4S
Trash Compactor @ 1500 DATE:
Pool Heater @ 'name plate' PLUMB:
Spa @ 'name plate'
Motors 746VA per HP DATE'
Garage Door Opiener MECH:
®ATE:
1) Total
2) First'10 KVA of general load @ 100%
3) Subtract line 2 from 1
4) Multiply line 3 @ 40%
5) Add lines 2 and 4
6) 60/50amp breaker for heat (10000)
7) 40/30amp breaker for heat (5000)
8) Total heat- Add lines 6 and 7
9) Multiply line 8 @ 65%
10) Add lines 5 and 9
11) Divide line 10 by 240
I
Summary:
Line 10 lslthe total KW
Line 11 isithe total Amps
SCANNED
BY
St Lucie -County
off. 6, 7 hsi A. (Generator Size Needed)
�; 3 (Breaker Size Needed)