Loading...
HomeMy WebLinkAboutPILE REPORTIerm`�-1891�008T 8020 S OCEAN DR1VE- CRYSTAL POOLS OF INDIAN RIVER 4684 N. US1 VERO BEACH FL. 32967 772-567-3067 -I FAX 770-5961 r 9'ecelvev germ ti `u�ie Cou ty nY SCQVNED St Lucie County FILE COPY 2 copies of the solar blanket ( solar pill) 0 T14ANK YOU, Jimmy Rouan 473-2311 Hutting is Engineers of Florida Inc. 1 Established 1967 YourProjectis Our Commitment April 12, 2018 Mr. John Butler Bodax Foundations, Inc. 11101 NW 55th Street Ft. Lauderdale, Florida 33309 lGeotechnical & Construction Materials Engineering, Testing, & Inspection Environmental Services Offices throughout the state of Florida www.nuttingengineers.com info@nuttingengineers.com S�bject: Report of Augercast Pile Installation Monitoring Proposed Residence and Pool 8020 South Ocean Drive Jensen Beach, Florida Dear Mr. Butler: RECEIVED MAY 032018 ST, woe county, Permitting FILE COPY Nutting Engineers of Florida, Inc. (NE) has completed observation of augercast piling operations for the proposed residence and pool at the subject site. Bodax Foundations, Inc. installed cast -in -place augured piles for support of the proposed construction. B�odax Foundations, Inc. installed a total of 54, 16-inch diameter augercast piles for the project. The piles were installed from April 4, 2018 to April 5, 2018. Please refer to the pile plan for the numbering provided to our office. The pile size and depth recommendations were based upon our review of the Report of Geotechnical Exploration prepared by GFA International dated December 11, 2017. The pile installation characteristics of each pile are presented in the attached Pile Installation Data. Identification of each pile location followed by the pile number is _shown on the Pile Location Plans attached. Each pile record in the attached summary tables shows the following information: ■ RECORD NUMBER IN CHRONOLOGICAL ORDER ■ THE PILE NUMBER (AS FOUND ON ATTACHED PLANS) ■ THE DIAMETER OF THE PILE ■ THE LENGTH OF PILE FROM GROUND SURFACE TO TIP ■ THE THEORETICAL VOLUME OF GROUT FOR THE PILE ■ THE NUMBER OF PUMP STROKES FOR THE PILE ■ THE ACTUAL VOLUME OF GROUT FOR THE PILE ■ THE GROUT FACTOR ■ THE DATE OF INSTALLATION ■ THE REINFORCEMENT TYPES ■ AND GENERAL COMMENTS AS NEEDED APPROVED 1 1310 Neptune Drive - Boynton Beach, Florida 33426 • (661) 736-4900 - Fax (561) 737-9975 Broward (954) 941-8700 • Port St. Lucie (772) 408-1050 • Miami Dade (305) 624-0060 The drilling operations were monitored in the field by our field engineer and inspector in order to approximately determine the type of material being penetrated. This identification was done based on the augering time, the materials received during the drilling operations and the relative hardness of the soils/rocks as indicated by the vibration or "chattering" of the hydraulic lines. The augercast piles were installed to depths of thirty feet below the existing ground surface of approximately. The piles were designed for an allowable compressive capacity of 40 tons for the residence and 15 tons for the pool as required by the structural specifications and the recommendations made by others. Generally, during the installation of the piles, easy drilling was observed from the ground level to approximately twenty-five feet. Below this depth range hard drilling was encountered to the final tip depth. I A21 house and pool piles received steel reinforcement consisting of full length cage with 6, #6 reinforcing bars with #3 ties spaced 3-inch on center in the top and bottom two feet of the cage andl 0-inches on center the remaining length of the pile as stated in the structural documents. We also note that eight pool piles were battered 15-degrees as stated on the pile location plan. Upon completion of this inspection process, and review of the recorded data, it is our opinion that the augercast piles installed for the residence attained the required design compressive capacity of 40 tons and the pool attained the required compressive capacity of 15 tons. The piles that were presently installed were constructed in substantial compliance with the plans and specifications. Drilling Condition. Note: We note that due to very loose sand soils throughout the subsurface profile at the site, in order to develop acceptable piles, the placement of grout well beyond typical amounts were needed within many piles installed at the site. The piling company attempted to minimize the amount of grout placed as best as possible; however, site conditions still resulted in excessive grout being needed within those piles. Upon completion of this inspection process, and review of the recorded data, it is our opinion that the augercast piles installed for the project attained the required design compressive capacity of 35 tons. The piles that were presently installed were constructed in substantial compliance with the plans and specifications. We note that it was monitored and ensured that the piles began installation at the survey locations provided in the field. If during drilling operations it was discovered that gross deviations from original locations have occurred, the deviation was attempted to be rectified. Nutting Engineers is not responsible for minor deviations which have occurred during drilling operations, along with incorrect surveyed pile locations during piling installation. We also note that some deviations may be due to the augerdrill shifting when attempting to drill through the hard rock or other encountered debris conditions. This condition is beyond the control of the site inspector and undersigned engineer. Nutting a Engineers ofFlodda Inc] Established 1967 YaurProjectls OurCommftment 2 i I' Our client for this geotechnical evaluation was: Mr. John Butler Bodax Foundations, Inc. 1101 NW 55t' Street Fit. Lauderdale, Florida 33309 NE shall bear no liability for the implementation of recommended inspection and testing services as described in this report if implemented by others. NE has no ability to verify the completeness, accuracy or proper technique of such procedures if performed by others. Tine Geotechnical Engineer warrants that the findings, recommendations, specifications, or professional advice contained herein, have been presented after being prepared in accordance with general accepted professional practice in the field of foundation engineering, soil mechanics and engineering geology. No other warranties are implied or expressed. We appreciate the opportunity to provide these services for you. If you should have any questions, or if we can be of any further assistance in this matter, please feel free to contact us. Respectfully Subi , T r ER F I c C. C i E. Gar �e, P.E. #69947 Senio- eeteciinical"Engineer Attaccl//ments: Pile Location Plan Pile Installation Records LTR BODAX PROP RES 8020 S-OCN DR JENSEN BCH ACP CEG DNutting Engineers of Florida Inc Established 1967 YourProjectisOur Commitment 3 TBS DRAWING MANIN51RO TOF—ICCAA MT F-P-W OFCORIIS-bTNR •m ING. POOLSPA PLAN FOR: a LOT I6, DIAMOND SANDS — EN BEACH, FL oFCU1t71S-SRfQ.VR B1C 31IN WBOI£ORINPART WRBOVI28Ep3PRFS5 WRIiIII(pF]VySyloti CIDRTdS - SiNCLMP, INC..' =9 N. MMITARY TRAIL, SUITE 3 PALM BEACH GARDENS, FL 33418 PYLS61-630-8534 FAX561"U"557 Step6eD D1. SiDelair,P.E. C.OA.NO. 5725 Florida Lfc—No.35631 PI P2 P3 P4 P5 PG P33 P7 P35 P3 G P1 I Fe P20 P21 P22 P2a P24 P25 AUGER -CAST PILE LAYOUT -5CALE: I/4' a 1'-0' THESE PLANS ARE NOT FOR CONSTRUCTION UNLESS STAMPED 'ConsWotlon Sdo, DATED, SIGNED AND SEALED BY THE ENGINEER. ALL CONSTRUG"ll SHALL BE IN COMPUMCE WITH ALL JURISDICTIONAL PERMITS, CONDIDONS AND CONTRACT DOCUMENTS. CONTRACTOR SHALL COORDINATE ALL DETAILS AND ELEVATIONS WITH ARCHITECT PRIOR TO CONSTRUCTION. CONSTRUCTION SET P40 it'00 P41 . ap PILE/CAP/COLUMN DETAIL V 4t SLAIE: NOT TO SCALE :9 0 W PILING SCHEDULE Q b 0 ;ti ra o C O u n uvaTALIATIOIJ NOTE: TOP OF PILE STEEL SHALL NOT EXCEED 3° (0.25 fee!) BELOW THE CAP ELEVATION " S-2 DESIGNATION TYPE 70P OP PILE PILE DEPTH PILE length , CAP eleohon PI•PIS I6'AUGER•CASi 5.50 navd 30.00' 7,17' P7-P25 16' AUGER -CAST __-24.50—d 6.00 navd 1 •2A.00 mvd _ 1 30_00'� � • 7.67' P26-P3I _ 16' AUGER -CAST 5.67 navd 1 -24.33 mvd _ 30.001 7.33' P32-P33 _ _ 16_AUGER-CAST 5.50 navd •24.50 _d '1---" 30_00 7_17' 734•P35 5.67 navd _ -2q,33 mvd - 30.00' 7.33' 16' AUGER -CAST P36•P37 _ 16' AUGER•CAST 6.00 navd I -24.00 w.1 _ 30_00' 7.67'_ P38•P42 _ 16' AUGER -CAST - 5.00 navd _ -25.00 mvd _ _ 30_00 _ 6_67' P43-P46 16'AUGER-CAST 5.67 navd •24.33 mvd - 30.OG' _ 7.33' Pool PdmO DY OTHERS --�--" BODAX FOUNDATION PROPOSED RESIDENCE 8020 S OCEAN DRIVE JENSEN BEACH, FLORIDA PILE LOG DATA OF AUGERCAST PILE INSTALLATION NUTTING ENGINEERS OF FLORIDA, INC. Record' No. Pile No. Pile Dia. (in) Pile Length (ft) Theoretic. Pile Volume (ft) Pump Strokes Total Volume of Grout pumped ft3 Grout Factor Date Installed Remarks 1 1 38 16.0 30 41.9 48 50.4 1.20 04/04/18 2 1 39 16.0 30 41.9 60 63.0 1.50 04/04/18 3 50 16.0 26 36.3 54 56.7 1.56 04/04/18 Batter 4 47 16.0 26 36.3 45 47.3 1.30 04/04/18 Batter 5 49 16.0 26 36.3 76 79.8 2.20 04/04/18 :Batter 6 51 16.0 26 36.3 48 50.4 1.39 04/04/18 Batter 7 53 16.0 26 36.3 50 52.5 1.45 04/04/18 Batter 8 1 41 16.0 30 41.9 48 50.4 1.20 04/04/18 9 43 16.0 30 41.9 49 51.5 1.23 04/04/18 10 9 16.0 30 41.9 49 51.5 1.23 04/04/18 11 32 16.0 30 41.9 47 49.4 1.18 04/04/18 12, 3 16.0 30 41.9 48 50.4 1.20 04/04/18 13 4 16.0 30 41.9 48 50.4 1.20 04/04/18 14 31 16.0 30 41.9 47 49.4 1.18 04/04/18 15 5 16.0. 30 41.9 51. 53.6 1.28 04/04/18 16 30 16.0 30 41.9 49 51.5 1.23 04/04/18 17 48 16.0 26 36.3 52 54.6 1.50 04/04/18 Batter 18 52 16.0 26 36.3 43 45.2 1.24 04/04/18 Batter 19 54 16.0 26. 36.3 48 50.4 1.39 04/04/18 Batter 20 40 16.0 30 41.9 54 56.7 1.35 04/04/18 21 42 16.0 30 41.9 46 48.3 1.15 04/04/18 22 25 16.0 30 41.9 50 52.5 1.25 04/04/18 23 1 24 16.0 30 41.9 48 50.4 1.20 04/04/18 24 13 16.0 30 41.9 54 56.7 1.35 04/04/18 25 6 16.0 .30 41.9 46 48.3 1.15 04/04/18 26 46 16.0 30 41.9 49 51.5 1.23 04/04/18 27 45 16.0 30 1 41.9 48 1 50.4 1.20 04/04/18 28 44 16.0 30 1 41.9 51 53.6 1.28 04/04/18 29 35 16.0 30 41.9 49 51.5 1.23 04/05/18 30 11 16.0 30 41.9 48 50A 1.20 04/05/18 31 21 16.0 30 41.9 50 52.5 1.25 04/05/18 32 22 16.0 30 41.9 49 51.5 1.23 04/05/18 33 34 16.0 30 41.9 48 50.4 1.20 04/05/18 34 13 16.0 30 41.9 48 50.4 1.20 1 04/05/18 35 20 16.0 30 41.9 49 51.5 1,23 04/05/18 36 29 16:0 30 41.9 48 50.4 1.20 04/05/18 37 28 16.0 30 41.9 53 55.7 1.33 04/05/18 38 27 16.0 30 41.9 48 50.4 1.20 04/05/18 Nulling E Enginee S of Florida Inc.1 Established 1967 e f I BODAX FOUNDATION PROPOSED RESIDENCE 8020 S OCEAN DRIVE JENSEN BEACH, FLORIDA PILE LOG DATA OF AUGERCAST PILE INSTALLATION NUTTING ENGINEERS OF FLORIDA, INC. Record No: Pile No. Pile Dia. (in) Pile Length (ft) Theoretic. Pile Volu3me (ft) Pump Strokes Total Volume of Grout pumped ft3 Grout Factor Date Installed Remarks 39 18 16.0 1 30 41.9 61 64.1 1.53 04/05/18 40 19 16.0 1 30 41.9 49 51.5 1.23 04/05/18 41 37 16.0 30 41.9 59 62.0 1.48 04/05/18 42 26 16.0 30 41.9 49 51.5 1.23 04/05/18 43 1 16.0 30 41.9 47 49.4 1.18 04/05/18 44 2 16.0 30 41.9 50 52.5 1.25 04/05/18 45 14 16.0 30 41.9 45 47.3 1.13 04/05/18. 46 16 16.0 30 41.9 51 53.6 .1.28 04/05/18 47 j 17 16.0 30 41.9 52 54.6 1.30 04/05/18 48 10 16.0 30 41.9 48 50.4 1.20. 04/05/18 49 15 16.0 30 41.9 50 52.5 1.25 04/05/18 50 12 16.0 30 41.9 48 50.4 1.20 04/05/18 51 36 16.0 30 41.9 48 50.4 1.20 04/05/18 52 33 16.0 30 41.9 53 55.7 1.33 04/05/18 53 8 16.0 30 41.9 47 49.4 1.18 04/05/18 54 11 7 16.0 30 41.9 56 58.8 1.40 04/05/18 Total linear feet drilled 1588 Total Grout (yd) 105 PILE LOG FL BODAX PROPOSED RES 8020 S OCEAN DR JENSEN ACP Minimum depth drilled 26 Maximum depth drilled 30 Nulling u E Engineers of Florida Inc.I Established 1967 K / Nulling Engineers of Florida Inc. I Established 1967 YourProjectis OurCommitment April 12, 2018 Mr. John Butler Bodax Foundations, Inc. 101 NW 55t' Street Ft. Lauderdale, Florida 33309 aeotechnical & Construction Materials Engineering, Testing, & Inspection Environmental Services Offices throughout the state of Florida www.nuttingengineers.com info@nuttingengineers.com Subject: Report of Augercast Pile Installation Monitoring Proposed Residence and Pool 8020 South Ocean Drive jJensen Beach, Florida Dear Mr. Butler: Nutting Engineers of Florida, Inc. (NE) has completed observation of augercast piling operations for the proposed residence and pool at the subject site. Bodax Foundations, Inc. installed cast -in -place augured p11es for support of the proposed construction. Bodax Foundations, Inc. installed a total of 54, 16-inch diameter augercast piles for the project. The piles were installed from April 4, 2018 to April 5, 2018. Please refer to the pile plan for the numbering provided to our office. The pile size and depth recommendations were based upon our review of the Report of Geotechnical Exploration prepared by GFA International dated December 11, 2017. The pile installation characteristics of each pile are presented in the attached Pile Installation Data. Identification of each pile location followed by the pile number is shown on the Pile Location Plans attached. Each pile record in the attached summary tables shows the following information: ■ RECORD NUMBER IN CHRONOLOGICAL ORDER ■ THE PILE NUMBER (AS FOUND ON ATTACHED PLANS) ■ THE DIAMETER OF THE PILE ■ THE LENGTH OF PILE FROM GROUND SURFACE TO TIP ■ THE THEORETICAL VOLUME OF GROUT FOR THE PILE ■ THE NUMBER OF PUMP STROKES FOR THE PILE ■ THE ACTUAL VOLUME OF GROUT FOR THE PILE_ ■ THE GROUT FACTOR ■ THE DATE OF INSTALLATION ■ THE REINFORCEMENT TYPES ■ AND GENERAL COMMENTS AS NEEDED 1310 Neptune Drive - Boynton Beach, Florida 33426 - (561) 736-4900 - Fax (561) 737-9975 Broward (954) 941-8700 - Port St. Lucie (772) 408-1050 - Miami Dade (305) 624-0060 The drilling operations were monitored in the field by our field engineer and inspector in order to approximately determine the type of material being penetrated. This identification was done based on the augering time, the materials received during the drilling operations and the relative hardness of the soils/rocks as indicated by the vibration or "chattering" of the hydraulic lines. The augercast piles were installed to depths of thirty feet below the existing ground surface of approximately. The piles were designed for an allowable compressive capacity of 40 tons for the residence and 15 tons for the pool as required by the structural specifications and the recommendations made by I thers. Generally, during the installation of the piles, easy drilling was observed from the ground level to approximately twenty-five feet. Below this depth range hard drilling was encountered to the final tip depth. i All house and pool piles received steel reinforcement consisting of full length cage with 6, #6 reinforcing bars with #3 ties spaced 3-inch on center in the top and bottom two feet of the cage andl0-inches on center the remaining length of the pile as stated in the structural documents. We also note that eight pool piles were battered 15-degrees as stated on the pile location plan. Upon completion of this inspection process, and review of the recorded data, it is our opinion that the augercast piles installed for the residence attained the required design compressive capacity of 40 tons and the pool attained the required compressive capacity of 15 tons. The piles that were presently installed Were constructed in substantial compliance with the plans and specifications. Drilling Condition Note: We note that due to very loose sand soils throughout the subsurface profile at the site, in order to develop acceptable piles, the placement of grout well beyond typical amounts were needed within many piles installed at the site. The piling company attempted to minimize the amount of grout placed as best as possible; however, site conditions still resulted in excessive grout being needed within those piles. I Upon completion of this inspection process, and review of the recorded data, it is our opinion that the augercast piles installed for the project attained the required design compressive capacity of 35 tons. The pies that were presently installed were constructed in substantial compliance with the plans and specifications. I We note that it was monitored and ensured that the piles began installation at the survey locations provided in'the field. If during drilling operations it was discovered that gross deviations from original locations have occurred, the deviation was attempted to be rectified. Nutting Engineers is not responsible for minor deviations which have occurred during drilling operations, along with incorrect surveyed pile locations during piling installation. We also note that some deviations may be due to the augerdrill shifting when attempting to drill through the hard rock or other encountered debris conditions. This condition is beyond the control of the site inspector and undersigned engineer. Nutting E Engineers ofFlodda Intl Established 1967 YourProjectls OurCamm1tment2 Our client for this geotechnical evaluation was: Mr. John Butler Bodax Foundations, Inc. 1101 NW 55t' Street Ft. Lauderdale, Florida 33309 NE shall bear no liability for the implementation of recommended inspection and testing services as .escribed in this report if implemented by others. NE has no ability to verify the completeness, accuracy or proper technique of such procedures if performed by others. The Geotechnical Engineer warrants that the findings, recommendations, specifications, or professional Advice contained herein, have been presented after being prepared in accordance with general accepted professional practice in the field of foundation engineering, soil mechanics and engineering geology. No other warranties are implied or expressed. We appreciate the opportunity to provide these services for you. If you should have any questions, or if we can be of any further assistance in this matter, please feel free to contact us. Respectfully. Sub , NUT EIR F , I C. 0 - r E. �w ,ek P.E. #69947 S',eui0 eotechnical Engineer Attachments: Pile Location Plan Pile Installation Records LTR BODAX PROP RES 8020 S-OCN DR JENSEN BCH ACP CEG I ,Nutting s Engineers ofFlodda Inc Established 1967 Yourpmjectis ourcomMament 3 ............ It 0 § c \ � ---�� H . ( rm M | --- L \ ¢ '� W, )( gg- --/ -------- V.- MIR, ................ .......... -7) POOIJS PLAN FOR: i CURTIS - SINCLAIR, 24C. p rivate Residence, IVULTrARY TR&H, SUrrE LOTH�DLAMONDSANDS PALM BEACH GARDENS, FL 33419 PILS61-63"534 PAXS'1-630-SSS7 JENSEN BEACH, FL C.O.A. NO. 572S PI P2 P3 P4 P5 PG P33 P7 r. P35 P20 P2I P22 P23 P24 P25 AUGER -CAST PILE LAYOUT 5CALE: 1/4' m 1'-0` THESE PLANS ARE NOT FOR CONSTRUCTION UNLESS STAMPED -ConeU k. Se". DATED, SIGNED AND SEALED BY THE ENGINEER ALL CONSTRUCTION SHALL BE IN COM PLIANCE WITH ALL JURISDICTIONAL PERMRS, 'ONDRIONS AND CONTRACT DOCUMENTS. CONTRACTOR SHALL COORDINATE ALL DETAILS AND ELEVATIONS WITH ARCHITECT PRIOR TO CONSTRUCTION. e P40 o I3 rAEeaeO To Po1Nr rl 0le To r}a rxe As slmvm BOTTOM - - Of PILE CAGE _ b0 P4 I EL: 5EE 5CHEDULE PILE/CAP/COLUMN DETAIL SLAIEi NOT TO SCALE V PILING SCHEDULE �0p Qa-1 m b d O b a q O U T O A INSTALLATION IJOTEI TOP OF PILE STEEL SHALL NOT EXCEED 3' (025I-t) BELOW THE CAP ELEVATION S-2 DESIGNATION TYPE TOP OP PILE PILE DEPM PILE length , CAP deatmn PI-P6 16'AUGER-CAST 5.50 navd 24.50 mvd 30.00' P7-P25 16' AUGER -LAST __ 6.00 navd 1 -24.00 nrvd 30.00' 1 •7.67' P26-P3I 16°AUGER-CAST 5.67 navd -24.33 mvd 30,00' 7.33' P32•P33 _ _ _ 16' AUGER -CAST 5.50 wvd •2q.50 mvd 30.00' t--"'- 7_I7' P34-P35- 5.67 nav4 �•2q,33 nrvd 30.00' 7.33' 16•AUGER-CAST P36-P37AUGER•CAST _6.00 navd -24.00 nrvd _ 30.00' S.DD navd -i-25.00 nrvd30_00' 7^67' _ 6_f.7' P38-P42_ 16•AUGER-Gl5T P43-P46 16'AUGER•CAST 5.67 navd •24.33 mvd 30.00' pool'ppmg BY OTHERS -- ---""" CONSTRUCTION SET BODAX FOUNDATION PROPOSED RESIDENCE 8020 S OCEAN DRIVE JENSEN BEACH, FLORIDA PILE LOG DATA OF AUGERCAST PILE INSTALLATION NUTTING ENGINEERS OF FLORIDA, INC. Record No. Pile No. Pile Dia. (in) Pile Length (ft) Theoretic. Pile Volume (ft) Pump Strokes Total Volume of Grout pumped (ft) Grout Factor Date Installed Remarks 1 38 16.0 30 41.9 48 50A 1.20 04/04/18 2 39 16.0 30 41.9 60 63.0 1.50 04/04/18 3 50 16.0 26 36.3 54 56.7 1.56 04/04/18 Batter 4 47 16.0 26 36.3 45 47.3 1.30 04/04/18 Batter 5 49 16.0 26 36.3 76 79.8 2.20 04/04/18 Batter 6 51 16.0 26 36.3 48 50.4 1.39 04/04/18 Batter 7 53 16.0 26 36.3 50 52.5 1.45 04/04/18 Batter 8 41 16.0 30 41.9 48 50.4 1.20 04/04/18 9 43 16.0 30 41.9 49 51.5 1.23 04/04/18 10 9 16.0 30 41.9 49 51.5 1.23 04/04/18 11 32 16.0 30 41.9 47 49.4 1.18 04/04/18 12 3 16.0 30 41.9 48 50.4 1.20 04/04/18 13 4 16.0 30 41.9 48 50.4 1.20 04/04/18 14 31 16.0 30 41.9 47 49.4 1.18 04/04/18 15 5 16.0 30 41.9 51 53.6 1.28 04/04/18 16 30 16.0 30 ..41.9 49 51.5 1.23 04/04/18 17 48 16.0 26 36.3 52 54.6 1.50 04/04/18 Batter 18 52 16.0 26 36.3. 43 45.2 1.24 04/04/18 Batter. 19 54 16.0 26 36.3 48 50.4 1.39 04/04/18 Batter 20 40 16.0 30 41.9 54 56.7 1.35 04/04/18 21 42 16.0 30 41.9 46 48.3 1.15 04/04/18 22 25 16.0 30 41.9 50 52.5 1.25 04/04/18 23 24 16.0 30 41.9 48 50.4 1.20 04/04/18 24 13 16.0 30 41.9 54 56.7 1.35 04/04/18 25 6 16.0 30 41.9 46 48.3 1.15 04/04/18 26 46 16.0 30 41.9 49 51.5 1.23 04/04/18 27 45 16.0 30 41.9 48 50.4 1.20 04/04/18 28 44 16.0 30 41.9 51 53.6 1.28 04/04/18 29 35 16.0 30 41.9 49 51.5 1.23 04/05/18 30 11 16.0 30 41.9 48 50.4 1.20 04/05/18 31 21 16.0 30 41.9 50 52.5 1.25 04/05/18 32 22 16.0 30 41.9 49 51.5 1.23 04/05/18 33 34 16.0 30 41.9 48 50.4 1.20 04/05/18 34 13 16.0 30 41.9 48 50.4 1.20 04/05/18 35 20 16.0 30 41.9 49 51.5 1,23 04/05/18 36 29 16.0 30 41.9 48 50.4 1.20 04/05/18 37 28 16.0 30 41.9 53 55.7 1.33 04/05/18 38 27 16.0 30: 41.9 1 48 50.4 1 1.20 04/05/18 Hutting E Engineers of Florida Inc. I Established 1967 b 6 -_20L YI_ • BODAX FOUNDATION PROPOSED RESIDENCE 8020 S OCEAN DRIVE JENSEN BEACH, FLORIDA PILE LOG DATA OF AUGERCAST PILE INSTALLATION NUTTING ENGINEERS OF FLORIDA, INC. Record No. Pile No. Pile Dia. (in) Pile Length (ft) Theoretic. Pile Volume (ft) 3 Pump Strokes Total Volume ofGrout Grout Pumped Factor Date Installed Remarks 39 18 16.0 30 41.9 61 64.1 1.53 04/05/18 40 19 16.0 30 41.9 49 51.5 1.23 04/05/18 41 37 16.0 30 41.9 59 62.0 1.48 04/05/18 42 26 16.0 30 41.9 49 51.5 1.23 04/05/18 43 1 16.0 30 41.9 47 49.4 1.18 04/05/18 44 2 16.0 30 41.9 50 52.5 1.25 04/05/18 45 14 16.0 30 41.9 45 47.3 1.13 04/05/18 46 16 16.0 30 41.9 51 53.6 1.28 04/05/18 47 I 17 16.0 30 41.9 52 54.6 1.30 04/05/18 48 10 16.0 30 41.9 48 50.4 1.20 04/05/18 49 1 15 16.0 30 41.9 50 52.5 1.25 04/05/18 50 12 16.0 30 41.9 48 50.4 1.20 04/05/18 51 36 16.0 30 41.9 48 50.4 1.20 04/05/18 52 33 16.0 30 41.9 53 55.7 1.33 04/05/18 53 8 16.0 30 41.9 47 49.4 1.18 04/05/18 54 7 16.0 30 41.9 56 58.8 1.40 04/05/18 Total linear feet drilled 1588 Total Grout (yd) 105 PILE LOG FL BODAX PROPOSED RES 8020 S OCEAN DR JENSEN ACP Minimum depth drilled 26 Maximum depth drilled 30 Nutting E Engineers of Florida Inc.l Established 1967 u os