Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFO�cM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE-WINDSOR MODEL -REAR SITTING-IMPAC Builder Name: WYNNE BUILDING CORP. Street: THE WINDSOR MODEL Permit Office: ST. LUCIE COUNTY City, State„ Zip: FT. PIERCE, FL, Permit Number: Owner: WYNNE BUILDING CORP. Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1448.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1152.00 ft2 A` b. Frame - Wood, Adjacent R=11.0 296.00 ft2 3. Number of units, if multiple family 1 �+\*� c. N/A R= ft2 4. Number of Bedrooms 3 �� d. N/A R= ft2 10. Ceiling Types (1753.0 sqft.) Insulation Area 5. Is this a worst case? Yes t v, i1 a. Under Attic (Vented) R=30.0 1753.00 ftz 6. Conditioned floor area above grade (ft2) 1753 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. R= ft2 11. Ducts R ft2 7. Windows(151.1 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 125 a. U-Factor: Dbl, U=0.54 151.11 ft2 SHGC: SHGC=0.25 b. U-Factor: N/A ft2 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 34.8 SEER:15.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 34.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 1.000 ft. Area Weighted Average SHGC: 0.250 14. Hot water systems a. Electric Cap: 40 gallons 8. Floor Types (1753.0 sqft.) Insulation Area EF: 0.970 a. Slab -On -Grade Edge Insulation R=0.0 1753.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits Pstat Glass/Floor Area: 0.086 Total Proposed Modified Loads: 53.29 PASS j Total Baseline Loads: 53.63 I hereby certify that the plans and specifications covered by Review of the plans and ScTKE Sxq?, this calculation are in compliance with the Florida Energy specifications covered by this y_ A0 Code. calculation indicates compliance �,j iiq '� ° --'.��` V1% with the Florida Energy Code.`O PREP D BY: DATE: -" Before construction is completed this building will be inspected for compliance with Section 553.908 r O �I�'� i a * 11- I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. G'OD WE OWNER/A . BUILDING OFFICIAL: DATE DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 10/9/2018 8:45 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 1 of 6 FORM RAMi 9017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: WYNNE-WINDSOR MODEL- Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1753 Lot # Owner Name: WYNNE BUILDING CORP. Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE BUILDING CORP. Rotate Angle: 225 Street: THE WINDSOR MODE Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range IFL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1753 14024 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 MASTER BEDROO 214 1712 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 MASTER BATH 56 448 No 0 1 Yes Yes Yes 4 M.BATH 61 488 No 0 1 Yes Yes Yes 5 I LAUDRY 36 288 No 0 1 No Yes Yes 6 BEDROOM 2 165 1320 No 0 1 1 Yes Yes Yes 7 I DINING/GREAT R 520 4160 No 0 1 Yes Yes Yes 8 KITCHEN 180 1440 Yes 0 1 Yes Yes Yes 9 BATH 2 50 400 No 0 1 Yes Yes Yes 10 HALL 25 200 No 0 1 No Yes Yes 11 FOYER 66 528 No 0 1 Yes Yes Yes 12 SITTING ROOM 152 1216 No 0 1 Yes Yes Yes 13 BEDROOM 3 165 1320 No 0 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet Slab -On -Grade Edge Insulatio MASTER BEDRO 31 ft 0 214 ftZ ---- 1 0 0 2 Slab -On -Grade Edge Insulatio WIC 1 ft 0 63 ftz ____ 1 0 0 3 Slab -On -Grade Edge Insulatio MASTER BATH 8 ft 0 56 ftZ -_-_ 1 0 0 4, Slab -On -Grade Edge Insulatio M. BATH 7 ft 0 61 ft2 ---- 1 0 0 10/9/2018 i8:45 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 2 of 6 FnQIM RAnS_gn17 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 5 Slab -On -Grade Edge Insulatio LAUDRY 1 ft 0 36 ft2 ---- 1 0 0 6 Slab -On -Grade Edge Insulatio BEDROOM 2 11 ft 0 165 ft2 --__ 1 0 0 7 Slab -On -Grade Edge Insulatio DINING/GREAT 28 ft 0 520 ft2 ---- 1 0 0 8 Slab -On -Grade Edge Insulatio KITCHEN loft 0 180 ft2 ---- 1 0 0 9 Slab -On -Grade Edge Insulatio BATH 2 5 ft 0 50 ft2 ---- 1 0 0 1'OSlab-On-Grade Edge Insulatio HALL 1 ft 0 25 ft2 ---- 1 0 0 1�1Slab-On-Grade Edge Insulatio FOYER 6 ft 0 66 ft2 ---- 1 0 0 112SIab-On-Grade Edge Insulatio SITTING ROOM 27 ft 0 152 ft2 ____ 1 0 0 1!3SIab-On-Grade Edge Insulatio BEDROOM 3 11 ft 0 165 ft2 ---- 1 0 0 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or shed Metal 1847 ft2 292 ft2 Light 0.3 No 0.5 No 0 18.4 i ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1753 ft2 N N CEILING Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 11 Under Attic (Vented) MASTER BEDRO 30 Blown 214 ft2 0.1 Wood 2 Under Attic (Vented) WIC 30 Blown 63 ft2 0.1 Wood 3 Under Attic (Vented) MASTER BATH 30 Blown 56 ft2 0.1 Wood 4 Under Attic (Vented) M. BATH 30 Blown 61 ft2 0.1 Wood 15 Under Attic (Vented) LAUDRY 30 Blown 36 ft2 0.1 Wood 6 Under Attic (Vented) BEDROOM 2 30 Blown 165 ft2 0.1 Wood 7 Under Attic (Vented) DINING/GREAT 30 Blown 520 ft2 0.1 Wood '8 Under Attic (Vented) KITCHEN 30 Blown 180 ft2 0.1 Wood 9 Under Attic (Vented) BATH 2 30 Blown 50 ft2 0.1 Wood 10 Under Attic (Vented) HALL 30 Blown 25 ft2 0.1 Wood 11 Under Attic (Vented) FOYER 30 Blown 66 ft2 0.1 Wood 12 Under Attic (Vented) SITTING ROOM 30 Blown 152 ft2 0.1 Wood 13 Under Attic (Vented) BEDROOM 3 30 Blown 165 ft2 0.1 Wood 10/9/2018 8:45 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 3 of 6 Fnycnn Rani-9n!7 INPUT All CHFCKLIST REPORT WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space ah Et In Et In Aran RA/Mile Fract*on Ahsor Gr-le% 1 SEL >N Exterior Concrete Block - Ext InaVASTER BE 4.1 1 0 8 0 8.0 ft2 0 0 0.5 0 _ 2 SW=>E Exterior . Concrete Block - Ext InEIVIASTER BE 4.1 15 0 8 0 120.0 ft2 0 0 0.5 0 3 NW=>S Exterior Concrete Block - Ext InddIASTER BE 4.1 15 0 8 0 120.0 ft2 0 0 0.5 0 4 I SW=>E Exterior Concrete Block - Ext In9VASTER BA 4.1 8 0 8 0 64.0 ft2 0 0 0.5 0 5 SW=>E Exterior Concrete Block - Ext InsuM. BATH 4.1 7 0 8 0 56.0 ft2 0 0 0.5 0 _ _ 6 SW=>E Exterior Concrete Block - Ext InfiffDROOM 2 4.1 11 0 8 0 88.0 ft2 0 0 0.5 0 7 NE >W Exterior Concrete Block - Ext InMNING/GRE 4.1 28 0 8 0 224.0 ft2 0 0 0.5 0 _ 8 NE=>W Exterior Concrete Block - Ext InsuKITCHEN 4.1 10 0 8 0 80.0 ft2 0 0 0.5 0 _ 9 SVN=>E Exterior Concrete Block - Ext Insul BATH 2 4.1 5 0 8 0 40.0 ft2 0 0 0.5 0 _ 10 SE=>N Exterior Concrete Block - Ext Insul FOYER 4.1 6 0 8 0 48.0 ft2 0 0 0.5 0 _ 11 NEI=>W Exterior Concrete Block - Ext InsSITTING RO 4.1 8 0 8 0 64.0 ft2 0 0 0.5 0 12 NW=>S Exterior Concrete Block - Ext InsSITTING RO 4.1 19 0 8 0 152.0 ft2 0 0 0.5 0 _ 13 SW=>E Exterior Concrete Block - Ext InfiffDROOM 3 4.1 11 0 8 0 88.0 ft2 0 0 0.5 0 14 N=I SW Garage Frame - Wood BEDROOM 2 11 37 8 296.0 ft2 0 0.25 0.5 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 SE=>N Insulated FOYER None .28 3 2 6 8 21.1 ft2 2 NE=>W Insulated SITTING RO None .28 3 6 8 20 ft2 WINDOWS Orientation shown is the entered orientation => changed to Worst Case. / Wall Overhang V/ # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NW=>S 3 Metal Low-E Double Yes 0.54 0.25 N 32.4 ft2 1 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 2 SW=>E 5 Metal Low-E Double Yes 0.54 0.25 N 6.9 ft2 1 ft 0 in 1 ft 4 in None None 3 SW=>E 6 Metal Low-E Double Yes 0.54 0.25 N 16.2 ft2 1 ft 0 in 1 ft 4 in None None 4. NE=>W 7 Metal Low-E Double Yes 0.54 0.25 N 39.8 ft2 1 ft 0 in 1 ft 4 in None None 5 NW=>S 12 Metal Low-E Double Yes 0.54 0.25 N 19.9 ft2 1 ft 0 in 1 ft 4 in None None 6 NW=>S 12 Metal Low-E Double Yes 0.54 0.25 N 19.9 ft2 1 ft 0 in 1 ft 4 in None None 7, SW=>E 13 'Metal Low-E Double Yes 0.54 0.25 N 16.2 ft2 1 ft 0 in 1 ft 4 in None None I GARAGE ;# Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 11 315ft2 315ft2 37ft 8ft 11 10/9/20181 8:45 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 4 of 6 . .i Fnx2M R4nsLgn17 INPUT SUMMARY CHECKLIST REPORT INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1636.1 89.82 168.92 .2578 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ i Split HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts Central Unit/ Split SEER: 15 34.8 kBtu/hr cfm 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None i Garage 0.97 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None I ftz DUCTS / -- Supply -- V # Location R-Value Area --- Return --- Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT QN RLF HVAC # Heat Cool 1 Attic 6 125 ftz Attic 35 ftz Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programaf ie Thermostat: Y Cooling 1 H Jan Feb Mar Venting Jan Feb Mar Ceiling Fans: Apr May X Jun X Jul Aug Sep Aug �XjSep Jun [ Jul Aug Sep � i Apr I i May L i Jun 4 Jul JXJ� Oct Nov Oct HNov Dec H Dec 10/9/2018 '8:45 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 5 of 6 FORM R405-.2017 INPUT SUMMARY CHECKLIST REPORT Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM. 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD)I AM 66 66 66 66 66 68 68 68 68 68 68 68 1 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Defailt(8 Ibs/sq.ft. 0 ft2 Oft 0.3 MASTER BEDROO Defa6lt(8 Ibs/sq.ft. ft2 ft 0.3 WIC Default(8 Ibs/sq.ft. ft2 ft 0.3 MASTER BATH Default(8 Ibs/sq.ft. ft2 ft 0.3 M. BATH Default(8 lbs/sq.ft. ft2 ft 0.3 IAUDRY Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 DINING/GREAT R Default(8 lbs/sq.ft. ft2 ft 0.3 KITCHEN Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 HALL Default(8 Ibs/sq.ft. ft2 ft 0.3 FOYER Default(8 Ibs/sq.ft. ft2 ft 0.3 SITTING ROOM Default 8 Ibs/s .ft. ft2 ft 0.3 BEDROOM 3 Name: Rating Compant: D. 10/9/2018 8:45 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 6 of 6 2017EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic/Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 34.8 a) Split system SEER 15.0 5. IsIthis a worst case? (yes/no) 5. Yes b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1753 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.540 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.250 14. Heating system: Capacity 34.8 c) Area 7c. 151.1 a) Split system heat pump HSPF 8.5 b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE ti) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE fl Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 ti) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.97 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 4.1 0 Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10131. 11.0 2. Masonry (Insulation R-value) 10B2. 1 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic- 11a. 30.0 b) Cross ventilation No b) Single assembly 11 b. c) Whole house fan No c) Knee walls/skylight walls 11 c. d) Multizone cooling credit d) Radiant barrier installed 11 d. No e) Multizone heating credit 0 Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Si nature: Date: Add of New Home: THE WIND�cS�OR MODEL City/FL Zip: FT. PIERCE. FL less \ V I 10/9/2018 8:45:35 AM EnergyGauge® USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA I Project Name: WYNNE-WINDSOR MODEL -REAR SITTING-IMPAC Builder Name: WYNNE BUILDING CORP. Street: THE WINDSOR MODEL Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Y U Owner: WYNNE BUILDING CORP. Jurisdiction: w Design (Location: FL, Fort Pierce v COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attil The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists I Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to I exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac 3s. Recessed lighting 'Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring -and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind popong and wiring Shower/tub on wall The air barrier installed at exterior walls adjacent�to showers and. Exterior walls adjacent to showers and tubs shall exterior tubs shall separate them from the showers and tubs. be insulated. Electrical/ppone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or'air-sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. I Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or ceilings, a. in addition, inspection or log walls shall be in accordance with the provisions of ICC-400. 10/9/2018 8I45 AM EnergyGauge® USA FBC 6th Edition (2017) Compliant Software Page 1 of 1