HomeMy WebLinkAboutENERGY EFFICIENCY CODEFO�cM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: WYNNE-WINDSOR MODEL -REAR SITTING-IMPAC
Builder Name: WYNNE BUILDING CORP.
Street: THE WINDSOR MODEL
Permit Office: ST. LUCIE COUNTY
City, State„ Zip: FT. PIERCE, FL,
Permit Number:
Owner: WYNNE BUILDING CORP.
Jurisdiction:
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (1448.0 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1 1152.00 ft2
A`
b. Frame - Wood, Adjacent
R=11.0 296.00 ft2
3. Number of units, if multiple family 1 �+\*�
c. N/A
R= ft2
4. Number of Bedrooms 3 ��
d. N/A
R= ft2
10. Ceiling Types (1753.0 sqft.)
Insulation Area
5. Is this a worst case? Yes t v, i1
a. Under Attic (Vented)
R=30.0 1753.00 ftz
6. Conditioned floor area above grade (ft2) 1753
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c.
R= ft2
11. Ducts
R ft2
7. Windows(151.1 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 125
a. U-Factor: Dbl, U=0.54 151.11 ft2
SHGC: SHGC=0.25
b. U-Factor: N/A ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
34.8 SEER:15.00
c. U-Factor: N/A ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Heat Pump
34.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 1.000 ft.
Area Weighted Average SHGC: 0.250
14. Hot water systems
a. Electric
Cap: 40 gallons
8. Floor Types (1753.0 sqft.) Insulation Area
EF: 0.970
a. Slab -On -Grade Edge Insulation R=0.0 1753.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
Pstat
Glass/Floor Area: 0.086 Total Proposed Modified Loads: 53.29
PASS
j Total Baseline Loads: 53.63
I hereby certify that the plans and specifications covered by
Review of the plans and
ScTKE Sxq?,
this calculation are in compliance with the Florida Energy
specifications covered by this
y_ A0
Code.
calculation indicates compliance
�,j iiq '� ° --'.��` V1%
with the Florida Energy Code.`O
PREP D BY:
DATE: -"
Before construction is completed
this building will be inspected for
compliance with Section 553.908
r
O �I�'� i a
* 11-
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Energy Code.
G'OD WE
OWNER/A .
BUILDING OFFICIAL:
DATE
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
10/9/2018 8:45 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 1 of 6
FORM RAMi 9017
INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: WYNNE-WINDSOR MODEL-
Bedrooms: 3
Address Type:
Street Address
Building Type: User
Conditioned Area: 1753
Lot #
Owner Name: WYNNE BUILDING CORP.
Total Stories: 1
Block/Subdivision:
# of Units: 1
Worst Case: Yes
PlatBook:
Builder Name: WYNNE BUILDING CORP.
Rotate Angle: 225
Street:
THE WINDSOR MODE
Permit Office: ST. LUCIE COUNTY
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
Whole House Fan: No
City, State,
Zip:
FT. PIERCE,
Family Type: Single-family
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
Design Temp
Int Design Temp
Heating
Design Daily Temp
V Design Location
TMY Site
97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
IFL, Fort Pierce FL_VERO_BEACH_MUNI 39
90
70
75
299
62
Low
BLOCKS
Number Name
Area
Volume
1 Entire House
1753
14024
SPACES
Number Name
Area
Volume Kitchen Occupants
Bedrooms
Infil ID
Finished Cooled
Heated
1 MASTER BEDROO
214
1712 No
0
1
1
Yes
Yes
Yes
2 WIC
63
504 No
0
1
No
Yes
Yes
3 MASTER BATH
56
448 No
0
1
Yes
Yes
Yes
4 M.BATH
61
488 No
0
1
Yes
Yes
Yes
5 I LAUDRY
36
288 No
0
1
No
Yes
Yes
6 BEDROOM 2
165
1320 No
0
1
1
Yes
Yes
Yes
7 I DINING/GREAT R
520
4160 No
0
1
Yes
Yes
Yes
8 KITCHEN
180
1440 Yes
0
1
Yes
Yes
Yes
9 BATH 2
50
400 No
0
1
Yes
Yes
Yes
10 HALL
25
200 No
0
1
No
Yes
Yes
11 FOYER
66
528 No
0
1
Yes
Yes
Yes
12 SITTING ROOM
152
1216 No
0
1
Yes
Yes
Yes
13 BEDROOM 3
165
1320 No
0
1
1
Yes
Yes
Yes
FLOORS
# Floor Type
Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
Slab -On -Grade Edge Insulatio
MASTER BEDRO 31 ft 0
214 ftZ
----
1 0
0
2 Slab -On -Grade Edge Insulatio
WIC
1 ft 0
63 ftz
____
1 0
0
3 Slab -On -Grade Edge Insulatio
MASTER BATH 8 ft 0
56 ftZ
-_-_
1 0
0
4, Slab -On -Grade Edge Insulatio
M. BATH 7 ft 0
61 ft2
----
1 0
0
10/9/2018 i8:45 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 2 of 6
FnQIM RAnS_gn17 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
5 Slab -On -Grade Edge Insulatio
LAUDRY 1 ft
0
36 ft2
----
1
0
0
6 Slab -On -Grade Edge Insulatio
BEDROOM 2 11 ft
0
165 ft2
--__
1
0
0
7 Slab -On -Grade Edge Insulatio
DINING/GREAT 28 ft
0
520 ft2
----
1
0
0
8 Slab -On -Grade Edge Insulatio
KITCHEN loft
0
180 ft2
----
1
0
0
9 Slab -On -Grade Edge Insulatio
BATH 2 5 ft
0
50 ft2
----
1
0
0
1'OSlab-On-Grade Edge Insulatio
HALL 1 ft
0
25 ft2
----
1
0
0
1�1Slab-On-Grade Edge Insulatio
FOYER 6 ft
0
66 ft2
----
1
0
0
112SIab-On-Grade Edge Insulatio
SITTING ROOM 27 ft
0
152 ft2
____
1
0
0
1!3SIab-On-Grade Edge Insulatio
BEDROOM 3 11 ft
0
165 ft2
----
1
0
0
ROOF
/
Roof
Gable
Roof
Solar SA
Emitt
Emitt
Deck
Pitch
V # Type Materials Area
Area
Color
Absor.
Tested
Tested
Insul.
(deg)
1 Gable or shed
Metal 1847 ft2
292 ft2
Light
0.3
No
0.5
No
0
18.4
i
ATTIC
V # Type
Ventilation Vent Ratio (1
in)
Area
RBS
IRCC
1 Full attic
Vented
150
1753 ft2
N
N
CEILING
Ceiling Type
Space
R-Value
Ins Type
Area
Framing Frac Truss Type
11 Under Attic (Vented)
MASTER BEDRO
30
Blown
214 ft2
0.1
Wood
2 Under Attic (Vented)
WIC
30
Blown
63 ft2
0.1
Wood
3 Under Attic (Vented)
MASTER BATH
30
Blown
56 ft2
0.1
Wood
4 Under Attic (Vented)
M. BATH
30
Blown
61 ft2
0.1
Wood
15 Under Attic (Vented)
LAUDRY
30
Blown
36 ft2
0.1
Wood
6 Under Attic (Vented)
BEDROOM 2
30
Blown
165 ft2
0.1
Wood
7 Under Attic (Vented)
DINING/GREAT
30
Blown
520 ft2
0.1
Wood
'8 Under Attic (Vented)
KITCHEN
30
Blown
180 ft2
0.1
Wood
9 Under Attic (Vented)
BATH 2
30
Blown
50 ft2
0.1
Wood
10 Under Attic (Vented)
HALL
30
Blown
25 ft2
0.1
Wood
11 Under Attic (Vented)
FOYER
30
Blown
66 ft2
0.1
Wood
12 Under Attic (Vented)
SITTING ROOM
30
Blown
152 ft2
0.1
Wood
13 Under Attic (Vented)
BEDROOM 3
30
Blown
165 ft2
0.1
Wood
10/9/2018 8:45 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 3 of 6
Fnycnn Rani-9n!7 INPUT All CHFCKLIST REPORT
WALLS
Adjacent
Cavity
Width
Height
Sheathing
Framing
Solar Below
Space
ah
Et
In
Et In
Aran
RA/Mile
Fract*on
Ahsor
Gr-le%
1
SEL >N Exterior
Concrete Block - Ext InaVASTER BE
4.1
1
0
8 0
8.0 ft2
0
0
0.5
0
_ 2
SW=>E Exterior
. Concrete Block - Ext InEIVIASTER BE
4.1
15
0
8 0
120.0 ft2
0
0
0.5
0
3
NW=>S Exterior
Concrete Block - Ext InddIASTER BE
4.1
15
0
8 0
120.0 ft2
0
0
0.5
0
4
I
SW=>E Exterior
Concrete Block - Ext In9VASTER BA
4.1
8
0
8 0
64.0 ft2
0
0
0.5
0
5
SW=>E Exterior
Concrete Block - Ext InsuM. BATH
4.1
7
0
8 0
56.0 ft2
0
0
0.5
0
_
_ 6
SW=>E Exterior
Concrete Block - Ext InfiffDROOM 2
4.1
11
0
8 0
88.0 ft2
0
0
0.5
0
7
NE >W Exterior
Concrete Block - Ext InMNING/GRE
4.1
28
0
8 0
224.0 ft2
0
0
0.5
0
_ 8
NE=>W Exterior
Concrete Block - Ext InsuKITCHEN
4.1
10
0
8 0
80.0 ft2
0
0
0.5
0
_ 9
SVN=>E Exterior
Concrete Block - Ext Insul BATH 2
4.1
5
0
8 0
40.0 ft2
0
0
0.5
0
_ 10
SE=>N Exterior
Concrete Block - Ext Insul FOYER
4.1
6
0
8 0
48.0 ft2
0
0
0.5
0
_ 11
NEI=>W Exterior
Concrete Block - Ext InsSITTING RO
4.1
8
0
8 0
64.0 ft2
0
0
0.5
0
12
NW=>S Exterior
Concrete Block - Ext InsSITTING RO
4.1
19
0
8 0
152.0 ft2
0
0
0.5
0
_
13
SW=>E Exterior
Concrete Block - Ext InfiffDROOM 3
4.1
11
0
8 0
88.0 ft2
0
0
0.5
0
14
N=I SW Garage
Frame - Wood BEDROOM 2
11
37
8
296.0 ft2
0
0.25
0.5
0
DOORS
# Ornt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1 SE=>N Insulated FOYER
None
.28
3
2
6 8
21.1 ft2
2 NE=>W Insulated SITTING RO
None
.28
3
6 8
20 ft2
WINDOWS
Orientation shown is the entered orientation => changed to Worst Case.
/
Wall
Overhang
V/
# Ornt ID
Frame Panes NFRC U-Factor
SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1 NW=>S 3
Metal Low-E Double Yes
0.54
0.25
N
32.4 ft2
1 ft 0 in
1 ft 4 in
Drapes/blinds
Exterior 5
2 SW=>E 5
Metal Low-E Double Yes
0.54
0.25
N
6.9 ft2
1 ft 0 in
1 ft 4 in
None
None
3 SW=>E 6
Metal Low-E Double Yes
0.54
0.25
N
16.2 ft2
1 ft 0 in
1 ft 4 in
None
None
4. NE=>W 7
Metal Low-E Double Yes
0.54
0.25
N
39.8 ft2
1 ft 0 in
1 ft 4 in
None
None
5 NW=>S 12
Metal Low-E Double Yes
0.54
0.25
N
19.9 ft2
1 ft 0 in
1 ft 4 in
None
None
6 NW=>S 12
Metal Low-E Double Yes
0.54
0.25
N
19.9 ft2
1 ft 0 in
1 ft 4 in
None
None
7, SW=>E 13
'Metal Low-E Double Yes
0.54
0.25
N
16.2 ft2
1 ft 0 in
1 ft 4 in
None
None
I
GARAGE
;# Floor Area Ceiling Area Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
11 315ft2 315ft2
37ft
8ft
11
10/9/20181 8:45 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 4 of 6
. .i
Fnx2M R4nsLgn17
INPUT SUMMARY CHECKLIST REPORT
INFILTRATION
# Scope Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50)
.000356
1636.1 89.82 168.92 .2578
7
HEATING SYSTEM
# System Type
Subtype
Efficiency Capacity
Block
Ducts
1 Electric Heat Pump/
i
Split
HSPF:8.5 34.8 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Efficiency Capacity Air Flow
SHR Block
Ducts
Central Unit/
Split
SEER: 15 34.8 kBtu/hr cfm
0.85 1
sys#1
HOT WATER SYSTEM
# System Type SubType
Location
EF Cap Use SetPnt
Conservation
1 Electric None
i
Garage
0.97 40 gal 60.9 gal 120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector
System Model # Collector Model # Area
Storage
Volume
FEF
None None
I
ftz
DUCTS
/ -- Supply --
V # Location R-Value Area
--- Return --- Air CFM 25 CFM25
Location Area Leakage Type Handler TOT OUT
QN RLF
HVAC #
Heat Cool
1 Attic 6 125 ftz
Attic
35 ftz Default Leakage Attic (Default) (Default)
1 1
TEMPERATURES
Programaf ie Thermostat: Y
Cooling 1 H Jan Feb Mar
Venting Jan Feb Mar
Ceiling Fans:
Apr May X Jun X Jul Aug Sep
Aug �XjSep
Jun [ Jul Aug Sep
� i Apr I i May L i Jun 4 Jul JXJ�
Oct Nov
Oct HNov
Dec
H Dec
10/9/2018 '8:45 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 5 of 6
FORM R405-.2017
INPUT SUMMARY CHECKLIST REPORT
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9 10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80 80
80
80
PM
80
80
78
78
78
78
78
78
78 78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78 78
78
78
PM.
78
78
78
78
78
78
78
78
78 78
78
78
Heating (WD)I
AM
66
66
66
66
66
68
68
68
68 68
68
68
1
PM
68
68
68
68
68
68
68
68
68 68
66
66
Heating (WEH)
AM
66
66
66
66
66
68
68
68
68 68
68
68
PM
68
68
68
68
68
68
68
68
68 68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Defailt(8 Ibs/sq.ft.
0 ft2
Oft
0.3
MASTER BEDROO
Defa6lt(8 Ibs/sq.ft.
ft2
ft
0.3
WIC
Default(8 Ibs/sq.ft.
ft2
ft
0.3
MASTER BATH
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M. BATH
Default(8 lbs/sq.ft.
ft2
ft
0.3
IAUDRY
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BEDROOM 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
DINING/GREAT R
Default(8 lbs/sq.ft.
ft2
ft
0.3
KITCHEN
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BATH 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
HALL
Default(8 Ibs/sq.ft.
ft2
ft
0.3
FOYER
Default(8 Ibs/sq.ft.
ft2
ft
0.3
SITTING ROOM
Default 8 Ibs/s .ft.
ft2
ft
0.3
BEDROOM 3
Name:
Rating Compant:
D.
10/9/2018 8:45 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 6 of 6
2017EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 99
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R 6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R 6.0
c) AHU location Attic/Attic
3. No. of units (if multiple -family)
3. 1
4. Number of bedrooms
4. 3
13. Cooling system: Capacity 34.8
a) Split system SEER 15.0
5. IsIthis a worst case? (yes/no)
5. Yes
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6. 1753
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a. 0.540
b) Solar Heat Gain Coefficient (SHGC)
7b. 0.250
14. Heating system: Capacity 34.8
c) Area
7c. 151.1
a) Split system heat pump HSPF 8.5
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
a) U-factor:(weighted average)
8a. NA
d) Gas furnace, natural gas AFUE
ti) Solar Heat Gain Coefficient (SHGC)
8b. NA
e) Gas furnace, LPG AFUE
fl Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a. 0.0
ti) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF 0.97
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF
2. Masonry (Insulation R-value)
10A2. 4.1
0 Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10131. 11.0
2. Masonry (Insulation R-value)
10B2.
1
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic-
11a. 30.0
b) Cross ventilation No
b) Single assembly
11 b.
c) Whole house fan No
c) Knee walls/skylight walls
11 c.
d) Multizone cooling credit
d) Radiant barrier installed
11 d. No
e) Multizone heating credit
0 Programmable thermostat Yes
*Label required by Section R303.1.3 of the Florida
Building Code, Energy
Conservation, if not DEFAULT.
I certify that this home has complied with the
Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Si nature:
Date:
Add of New Home: THE WIND�cS�OR MODEL
City/FL Zip: FT. PIERCE. FL
less
\ V
I
10/9/2018 8:45:35 AM EnergyGauge®
USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
I
Project Name: WYNNE-WINDSOR MODEL -REAR SITTING-IMPAC Builder Name: WYNNE BUILDING CORP.
Street: THE WINDSOR MODEL Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Y
U
Owner: WYNNE BUILDING CORP. Jurisdiction:
w
Design (Location: FL, Fort Pierce
v
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attil
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows,
skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
I
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space
walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
I
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spac
3s.
Recessed lighting
'Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and
wiring
Batt insulation shall be cut neatly to fit around wiring
-and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind popong and wiring
Shower/tub
on
wall
The air barrier installed at exterior walls adjacent�to showers and.
Exterior walls adjacent to showers and tubs shall
exterior
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/ppone
box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or'air-sealed boxes shall be installed.
HVAC register
boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
I
Caulking or other adhesive sealants shall not be used to fill voids
between fire sprinkler cover plates and walls or ceilings,
a. in addition, inspection or log walls shall be in accordance with the provisions of ICC-400.
10/9/2018 8I45 AM EnergyGauge® USA FBC 6th Edition (2017) Compliant Software Page 1 of 1