Loading...
HomeMy WebLinkAboutEVALUATION REPORT - METAL ROOFINGEVALUATION REPORT OF METAL SALES MANUFACTURING CORPORATION '26 GA. IMAGE H PANEL' FLORIDA BUILDING CODE 5TH EDITION (2014) FLORIDA PRODUCT APPROVAL FL 14645.11-R2 RECEIVED 1 ROOFING METAL ROOFING NOV 0 0 2018 r. Lucie County,_ !0rm_ in9 Prepared For: Metal Sales Manufacturing Corporation 545 South 3rd Street, Suite 200 Louisville, KY 40202 Telephone: (502) 855-4300 Fax: (502) 8554290 Prepared By: Bala Sockalingam, Ph.D,, P.E. Florida Professional Engineer #Q 1216.N Lansing Ave., Suite C Tulsa, OK 74106 Telephone: (918) 492-5992 FAX: (866) 366-1543 SCANNED, St Lucie County -p-���r- S1 00 This report consists of Evaluation Report (3 Pages including cover) Installation Details (1 Page) Report No. C2010-11 Date: 3.27.15 A,...,...• a •' \ C E NS •�f'i '�® No 62240 a• • •• q • • O • • 1"i 1A •g • • W Q STATE OF 'z ••.•.• � �� •• � R 1 0 •� ��taA .� FL 14645.11-R2 C2010-11 3.27.15 Page 2 of 3 Manufacturer: Metal Sales Manufacturing Corporation Product Name: Image II Panel Description: Max. 16" wide coverage with V high ribs Materials: Min. 26 ga., 50 ksi steel. Galvanized coated steel (ASTM A653) or Galvalume coated steel (ASTM A792) or painted steel (ASTM A755). Deck Description: Min. 7/16" thick OSB or min. 15/32" thick Plywood for new and existing constructions. Designed and installed as per FBC 2014. Deck Attachment: 8d x 2.5" long ring shank nails or 98 x 2" long wood screws @ 6" o.c. (Minimum) in the plywood field and edges 'New Underlayment: Minimum underlayment as per FBC 2014 Section 1507.4.5.1. Required for new construction and optional for reroofing construction. Existing Underlayment: One layer of asphalt shingles over one layer of #30 felt. For reroofing (Optional) construction only. Slope: 2:12 or greater in accordance with FBC 2014 Section 1507.4.2 Allowable Uplift Load: 20.75 psf @ fastener spacing of 24" o.c (Factor of Safety = 2) 63.50 psf @ fastener spacing of 6" o.c 86.55 psf @ fastener spacing of 6" o.c with 3/8" bead adhesive in panel sidelap Fastener Pattern: #10 pancake head screws along panel seam. Fastener shall be of sufficient length to penetrate through the deck a minimum of 'A". Sidelap Adhesive: Schnee -Morehead SM7108 Permathane adhesive Test Standards: Roof assembly tested in accordance with UL580-94 (Rev 98) `Uplift Resistance of Roof Assemblies' & UL1897-98 `Uplift Tests for Roof Covering Systems'. Code Compliance: The product described herein has demonstrated compliance with FBC 2014 Section 1507.4 Product Limitations: Design wind loads shall be determined for each project in accordance with FBC 2014 Section 1609 or ASCE 7-10 using allowable stress design. The maximum fastener spacing listed herein shall not be exceeded. This evaluation report is not applicable in High Velocity Hurricane Zone. Fire classification is not within scope of this Evaluation Report. Refer to FBC 2014 Section 1505 and current FL 14645.11-R2 C2010-11 3.27.15 Page 3 of 3 approved roofing materials directory or ASTM E108/UL790 report from an accredited laboratory for fire ratings of this product. Supporting Documents: UL580/UL1897 Test Reports Farabaugh Engineering and Testing Inc Project No. T176-11, Reporting Date 4/26/11 Project No. T260-11, Reporting Date 8/15111 I EXISTING SHINGLES SEE DETAIL 1 (OPTIONAL) ROOF PANEL �� \ r-1 MIN. 2X_ WOOD RAFTER/JOIST/ TRUSS AT MAX. 24" O.C. EXISTING SHINGLES SEE DETAIL 2 (OPTIONAL) ROOF PANEL MIN. 2X_ WOOD RAFTER/JOIST/ TRUSS AT MAX. 24" O.C. NEW UNDERLAYMENT- (REQUIRED ONLY FOR NEW CONSTRUCTION) EXISTING SHINGLES (OPTIONAL) DETAIL 1 EXISTING UNDERLAYMENT — (OPTIONAL) NEW UNDERLAYMENT (REQUIRED ONLY FOR NEW CONSTRUCTION) EXISTING SHINGLES (OPTIONAL) DETAIL 2 EXISTING UNDERLAYMENT (OPTIONAL) NEW UNDERLAYMENT - (REQUIRED ONLY FOR NEW CONSTRUCTION) MAX. 16" MINIMUM ATTACHMENT: EXISTING UNDERLAYMENT kN-� 8d x 2.5" LONG RING SHANK NAIL (OPTIONAL) OR #8 x 2" LONG WOOD SCREWS SPACED @ 6" O.C. IN THE FIELD & AT EDGES FASTENING PATTERN 1 NEW UNDERLAYMENT (REQUIRED ONLY FOR NEW CONSTRUCTION) ADHESIVE IN THE PANEL SIDELAP PANEL FASTENER SPACING PER ALLOWABLE PRESSURE TABLE. OSB 7/16" THICK (MIN.) OR PLYWOOD 15/32" THICK (MIN.) PANEL FASTENER SPACING PER ALLOWABLE PRESSURE TABLE. \--OSB 7/16' THICK (MIN.) OR - EXISTING UNDERLAYMENT MINIMUM ATTACHMENT: PLYWOOD 15/32" THICK (MIN.) (OPTIONAL) 8d x 2.5" LONG RING SHANK NAIL OR #8 x 2" LONG WOOD SCREWS SPACED ® 6" O.C. IN THE FIELD & AT EDGES FASTENING PATTERN 2 TYPICAL PANEL INSTALLATION X—SECTION ALLOWABLE UPLIFT PRESSURE #10 PANCAKE SCREW ® MAX. 24' O.C. PANEL MIN 26 GA. OSS 7/16" THICK (MIN.) OR PLYWOOD 15/32" THICK (MIN.) SIDELAP ADHESIVE NOM. 3/8" BEAD #10 PANCAKE SCREW ® MAX. 6" O.C. PANEL 1 MIN 26 GA. OSS 7/16" THICK (MIN.) OR PLYWOOD 15/32" THICK (MIN.) SIDELAP ADHESIVE LOCATION FASTENING PATTERN FASTENER SPACING (IN) ADHESIVE BEAD SIZE PRESSURE (PSF) 1 24 NONE 20.75 1 6 NONE 63.50 2 6 3/8" 1 86.55 • SIDELAH AUHESNt IN IHt HAALL SIUti-Al' GENERAL NOTES: 1. ARCHITECTURAL ROOF PANEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE FLORIDA BUILDING CODE (FBC). 2. ROOF PANELS SHALL BE MIN. 26 GA. (t = 0.018"). MAX. EFFECTNE COVERING WIDTH OF PANEL = 16". 3. THE ROOF PANELS SHALL BE INSTALLED OVER SHEATHING & STRUCTURE AS SPECIFIED ON THIS DRAWING. 4. REQUIRED DESIGN WIND LOADS SHALL BE DETERMINED FOR EACH PROJECT. THIS PANEL SYSTEM MAY NOT BE INSTALLED WHEN THE REQUIRED DESIGN WIND LOADS ARE GREATER THAN THE ALLOWABLE WIND LOADS SPECIFIED ON THIS DRAWING. 5. ALL FASTENERS MUST BE IN ACCORDANCE WITH THIS DRAWING & THE FLORIDA BUILDING CODE. IF A DIFFERENCE OCCURS BETWEEN THE MINIMUM REQUIREMENTS OF THIS DRAWING & THE CODE, THE CODE SHALL CONTROL. 6. RAFTERS/JOISTS/TRUSSES MUST BE DESIGNED TO WITHSTAND WIND LOADS AS REQUIRED FOR EACH APPLICATION AND ARE THE RESPONSIBILITY OF OTHERS. d 0 0 0 N CD wN Z ~0 7 04 (A 0 00 f a 4 Nyj Z 'm Lj Q �Joo M —I N w �No'o J 7)z) o0 za <� Ld a J w o o a a N„m w Q< ui N' V U Z. Rm � II OF