Loading...
HomeMy WebLinkAboutEVALUATION REPORT - UNDERLAYMENTSCREEK TECHNICAL SERVICES, LLC Cerfificate of Authorization No. 29824 17520 Edinburgh Drive Tampa, FL 33647 (813) 480-3421 EVALUATION REPORT FLORIDA BUILDING CODE, 6' EDMON (2017) (Manufacturer: ,Quality Assurance: SCOPE (Category: Subcategory: Code Sections: !Properties: PRODUCT DESCRIPTION TAMKO@ ASTM Slate Surfaced Roll Roofing �TAMKO@ ASTM Tile Underlayment �TAMKO@ Master Smooth TAMKOS Moisture Guard@ TAMKO@ No.15 ASTM Asphalt Saturated Organic Felt TAMKOO No.15 UL Asphalt Saturated :Organic Felt TAMKO@ No. 30 ASTM Asphalt Saturated (Organic Felt TAMKOS No. 30 UL Asphalt Saturated !Organic Felt TAMKO BUILDING PRODUCTS, INC. P.O. Box 1404 Joplin, MO 64802 (417) 624-6644 http://www.tamko.com UL LLC (QUA9625) Roofing Undedayments 1507.1.1 Physical properties Issued October 19, 2017 SCANNED BY St Lucie County ASTM D 6380, Class M, Type II underiayment constructed from organic felt saturated with asphalt and coated on both sides with asphalt and surfaced with granules. ASTM D 6380, Class M, Type II underiayment constructed from an organic felt saturated with asphalt then coated on both sides with asphalt and surfaced with granules. ASTM D 6380, Class S, Type IV underiayment constructed from an organic felt saturated with asphalt then coated on both sides with asphalt and surfaced with a fine mineral. For use in non-HVHZ only. Self -adhered, ASTM D 1970, fiberglass reinforced, modified bitumen sheet membrane with a mineral surfacing and a removable release film on the adhesive side and removable selvedge release tape. ASTM D 226, Type I underiayment constructed from a non -perforated organic felt that is saturated with asphalt ASTM D 226, Type I underiayment constructed from a non -perforated organic felt that is saturated with asphalt ASTM D 226, Type 11 underlayment constructed from a non -perforated organic felt that is saturated with asphalt ASTM D 226, Type II underiayment constructed from a non -perforated organic felt that is saturated with asphalt TAMKO@ TW Metal and Self -adhered, flexible, ASTM D 1970 and TAS.103, rubberized asphalt sheet membrane ;Tile Underlayment with a polymer film on the surface and a removable release film on the adhesive side. TAMKO@ TW Self -adhered, flexible, ASTM D 1970, rubberized asphalt sheet membrane with a Underlayment polymer film on the surface and a removable release film on the adhesive side. I TBP14001.4 FL12328-R8 Page 1 of 'This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. TAMKO BUILDING PRODCUTS, INC. JCREEKTAMKO Underlayments TECHNICAL SERVICES, LLC TAMKOO TAM -FELT Alternate to ASTM D 226, Type I and Type II underlayment constructed from a non - perforated organic felt that is saturated with asphalt APPLICATION METHOD Installation shall be in accordance with the published manufacturer's installation instructions, the FBC, and the requirements below. Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to underlayment application. The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction. Plywood deck shall be installed in accordance with FBC requirements. Roof decks shall have no more than 118" gap at abutting 'joints. The minimum application temperature shall be 50°F except as follows: a) The minimum application temperature of TAMK@ TW Metal and Tile Underlayment and TAMKO® TW Underlayment shall be 40°F. b) The minimum application temperature of TAMKO® Moisture Guard® shall be 35"F. The minimum roof slope shall be in accordance with FBC requirements except as follows: a) The minunum slope of TAMKO®ASTM Slate Surfaced Roll Roofing shall be 2:12. Underlayments shall be exposed in accordance with the manufacturer's recommendations, but in no case shall exposure exceed 30 days. Exception. TAMKO® TW Metal and Tile Undedayment may be exposed for a maximum 90 days. Self -adhering underlayments may be adhered to primed or unprimed plywood substrates in the non-HVHZ. All roof coverings shall be mechanically fastened through the underlayment to the roof deck. Allowable Roof Covadnaw Metal Root Mineral Wood Underla ' `. Asphalt. Panels and ' i Surfaced Roll' Shingles and Slate . , - Clay and ent Shingles :Shln les Roofing- Shakes ".. - -Shingles Con creleTile TAMKO® ASTM Slate Surfaced Roll Roofing Y+ N N N N Y TAMKO® ASTM Tile Underlayment N N N N N Y TAMKOV Master Smooth Y' N N N N N TAMKO® Moisture Guard® Y N N N N N TAMKO® No.15 ASTM Asphalt Saturated Organic Y Y Y Y2 N N Felt TAMKO® No.15 UL Asphalt Y Y Y Y2 Y N Saturated Organic Felt TAMKOO No. 30 ASTM Asphalt Saturated Organic Y Y Y Y Y Y Felt TAMKOS No. 30 UL Asphalt Saturated Organic Felt Y Y Y N Y N TAMKOS TW Metal and Tile Underlayment Y Y N N N Y TAMKOV TW Underlayment Y Y N N N N TAMKO® TAM -FELT Y N N N N N wows: 1) upen vaney appacauons per -loul.z.yz 2) Wood shingles only TBP14001.4 FL12328-R8 Page 2 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G203. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report Is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEKTAMKO BUILDING PRODCUTS, INC. TAMKO Undertayments TECHNICAL SERVICES, LLC UMITATtow 1) Fire Classification is not within the scope of this evaluation. 2) Wind uplift resistance in not within scope of this evaluation. 3) Installation of the evaluated product shall comply with this report, the FBC, and the manufacturer's published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 4) Contact the manufacturer when installing at temperatures below the minimum application temperature. 5) Unless otherwise stated, the minimum roof slope shall be in accordance with FBC requirements. 6) All underlayments shall be installed with the roll length parallel to the eave, starting at the eave, and lapped in successive courses installed up the deck in a manner that effectively sheds water from the deck. End laps shall be staggered between courses in accordance with the manufacturer's application instructions. 7) The underlayment may be used as described in other current FBC product approval documents. 8) The underlayment shall not be installed over existing roof coverings. 9) Contact the manufacturer regarding specific exposure limits for each undedayment 10) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 G20-3. REFERENCES Enti Report No. Standard Year PRI Construction Materials Technologies (17ST6049) TAP-192-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST6049) TAP-193-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST6049) TAP214-02-01 ASTM D 4869 2016 PRI Construction Materials Technologies (W6049) TAP 215-02-01 ASTM D 226 2009 PRI Construction Materials Technologies (rST6049) TAP 216-02-03 ASTM D 6380 2003(2013) PRI Construction Materials Technologies (TST6049) TAP 217-02-01 REV ASTM D 6380 2003(2013) PRI Construction Materials Technologies (TST6049) TAP 216-02-01 ASTM D 226 2009 PRI Construction Materials Technologies (TST6049) TAP-219-02-01 ASTM D 226 2009 PRI Construction Materials Technologies (I ST6049) TAP 220-02-01 ASTM D 6380 2003(2013) PRI Construction Materials Technologies (17ST6049) TAP 222-02-01 ASTM D 4869 2016 PRI Construction Materials Technologies (TST6049) TAP-245-02-01 TAS 103 1995 ASTM D 4798 2011 PRI Construction Materials Technologies (TST6049) TAP-311-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (rST6049) PRI Construction Materials Technologies (TST6049) TAP-319-02-01.1 TAP-387-02-M ACC 188 2012 PRI Construction Materials Technologies (TST6049) TAP-388-02-01 ASTM D 1970 ASTM D 1970 2015a 2015a UL LLC (TST9628) 13CA12269 ASTM D 226 2009 FL12328-R8 3of4 is evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report Is valid. 'This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. ` CREEK TECHNICAL SERVICES, LLC COMPLIANCE STATEMENT TAMKO BUILDING PRODCUTS, INC. TAMKO Underlayments The products evaluated herein by Zachary R Priest, P.E. have demonstrated compliance with the Florida Building Code, a Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer. rR»A���,i S4S'. No 74021 STATE OF OR IV N CERTIFICATION OF INDEPENDENCE 2017.10.19 12:15:58 04'00' Zachary R Priest, P.E. Florida Registration No. 74021 Organization No. ANE9641 CREEK Technical Services, LLC does not have, nor vn11 it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned, operated, or controlled by any company menuracturing or distributing products underthis evaluation. Zachary R. Priest, P.E. does not have, nor vn11 acquire, a financial interest in anycompany manufacturing or distributing products underthis evaluation. Zachary R Priest, P.E. does not have, nor will acqu!r--a fmandsl interest in arry other entity involved in the approval pmcess cf the product END OF REPORT TBP140DI A FL12328-R8 Page 4 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20 3. The manufacturer shall notify CREEK 'Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein.