HomeMy WebLinkAboutEVALUATION REPORT - UNDERLAYMENTSCREEK
TECHNICAL SERVICES, LLC
Cerfificate of Authorization No. 29824
17520 Edinburgh Drive
Tampa, FL 33647
(813) 480-3421
EVALUATION REPORT FLORIDA BUILDING CODE, 6' EDMON (2017)
(Manufacturer:
,Quality Assurance:
SCOPE
(Category:
Subcategory:
Code Sections:
!Properties:
PRODUCT DESCRIPTION
TAMKO@ ASTM Slate
Surfaced Roll Roofing
�TAMKO@ ASTM Tile
Underlayment
�TAMKO@ Master
Smooth
TAMKOS Moisture
Guard@
TAMKO@ No.15 ASTM
Asphalt Saturated
Organic Felt
TAMKOO No.15 UL
Asphalt Saturated
:Organic Felt
TAMKO@ No. 30 ASTM
Asphalt Saturated
(Organic Felt
TAMKOS No. 30 UL
Asphalt Saturated
!Organic Felt
TAMKO BUILDING PRODUCTS, INC.
P.O. Box 1404
Joplin, MO 64802
(417) 624-6644
http://www.tamko.com
UL LLC (QUA9625)
Roofing
Undedayments
1507.1.1
Physical properties
Issued October 19, 2017
SCANNED
BY
St Lucie County
ASTM D 6380, Class M, Type II underiayment constructed from organic felt saturated
with asphalt and coated on both sides with asphalt and surfaced with granules.
ASTM D 6380, Class M, Type II underiayment constructed from an organic felt saturated
with asphalt then coated on both sides with asphalt and surfaced with granules.
ASTM D 6380, Class S, Type IV underiayment constructed from an organic felt saturated
with asphalt then coated on both sides with asphalt and surfaced with a fine mineral. For
use in non-HVHZ only.
Self -adhered, ASTM D 1970, fiberglass reinforced, modified bitumen sheet membrane
with a mineral surfacing and a removable release film on the adhesive side and
removable selvedge release tape.
ASTM D 226, Type I underiayment constructed from a non -perforated organic felt that is
saturated with asphalt
ASTM D 226, Type I underiayment constructed from a non -perforated organic felt that is
saturated with asphalt
ASTM D 226, Type 11 underlayment constructed from a non -perforated organic felt that is
saturated with asphalt
ASTM D 226, Type II underiayment constructed from a non -perforated organic felt that is
saturated with asphalt
TAMKO@ TW Metal and Self -adhered, flexible, ASTM D 1970 and TAS.103, rubberized asphalt sheet membrane
;Tile Underlayment with a polymer film on the surface and a removable release film on the adhesive side.
TAMKO@ TW Self -adhered, flexible, ASTM D 1970, rubberized asphalt sheet membrane with a
Underlayment polymer film on the surface and a removable release film on the adhesive side.
I
TBP14001.4 FL12328-R8 Page 1 of
'This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
TAMKO BUILDING PRODCUTS, INC.
JCREEKTAMKO Underlayments
TECHNICAL SERVICES, LLC
TAMKOO TAM -FELT Alternate to ASTM D 226, Type I and Type II underlayment constructed from a non -
perforated organic felt that is saturated with asphalt
APPLICATION METHOD
Installation shall be in accordance with the published manufacturer's installation instructions, the FBC, and the
requirements below.
Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be
checked for protrusion and corrected prior to underlayment application.
The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction. Plywood deck
shall be installed in accordance with FBC requirements. Roof decks shall have no more than 118" gap at abutting
'joints.
The minimum application temperature shall be 50°F except as follows:
a) The minimum application temperature of TAMK@ TW Metal and Tile Underlayment and TAMKO® TW
Underlayment shall be 40°F.
b) The minimum application temperature of TAMKO® Moisture Guard® shall be 35"F.
The minimum roof slope shall be in accordance with FBC requirements except as follows:
a) The minunum slope of TAMKO®ASTM Slate Surfaced Roll Roofing shall be 2:12.
Underlayments shall be exposed in accordance with the manufacturer's recommendations, but in no case shall
exposure exceed 30 days.
Exception. TAMKO® TW Metal and Tile Undedayment may be exposed for a maximum 90 days.
Self -adhering underlayments may be adhered to primed or unprimed plywood substrates in the non-HVHZ.
All roof coverings shall be mechanically fastened through the underlayment to the roof deck.
Allowable Roof Covadnaw
Metal Root
Mineral
Wood
Underla
' `. Asphalt.
Panels and '
i Surfaced Roll'
Shingles and
Slate . , -
Clay and
ent
Shingles
:Shln les
Roofing-
Shakes "..
- -Shingles
Con creleTile
TAMKO® ASTM Slate
Surfaced Roll Roofing
Y+
N
N
N
N
Y
TAMKO® ASTM Tile
Underlayment
N
N
N
N
N
Y
TAMKOV Master Smooth
Y'
N
N
N
N
N
TAMKO® Moisture Guard®
Y
N
N
N
N
N
TAMKO® No.15 ASTM
Asphalt Saturated Organic
Y
Y
Y
Y2
N
N
Felt
TAMKO® No.15 UL Asphalt
Y
Y
Y
Y2
Y
N
Saturated Organic Felt
TAMKOO No. 30 ASTM
Asphalt Saturated Organic
Y
Y
Y
Y
Y
Y
Felt
TAMKOS No. 30 UL Asphalt
Saturated Organic Felt
Y
Y
Y
N
Y
N
TAMKOS TW Metal and Tile
Underlayment
Y
Y
N
N
N
Y
TAMKOV TW Underlayment
Y
Y
N
N
N
N
TAMKO® TAM -FELT
Y
N
N
N
N
N
wows: 1) upen vaney appacauons per -loul.z.yz
2) Wood shingles only
TBP14001.4 FL12328-R8 Page 2 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G203. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report Is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEKTAMKO BUILDING PRODCUTS, INC.
TAMKO Undertayments
TECHNICAL SERVICES, LLC
UMITATtow
1) Fire Classification is not within the scope of this evaluation.
2) Wind uplift resistance in not within scope of this evaluation.
3) Installation of the evaluated product shall comply with this report, the FBC, and the manufacturer's published
application instructions. Where discrepancies exist between these sources, the more restrictive and FBC
compliant installation detail shall prevail.
4) Contact the manufacturer when installing at temperatures below the minimum application temperature.
5) Unless otherwise stated, the minimum roof slope shall be in accordance with FBC requirements.
6) All underlayments shall be installed with the roll length parallel to the eave, starting at the eave, and lapped
in successive courses installed up the deck in a manner that effectively sheds water from the deck. End
laps shall be staggered between courses in accordance with the manufacturer's application instructions.
7) The underlayment may be used as described in other current FBC product approval documents.
8) The underlayment shall not be installed over existing roof coverings.
9) Contact the manufacturer regarding specific exposure limits for each undedayment
10) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61 G20-3.
REFERENCES
Enti
Report No.
Standard
Year
PRI Construction Materials Technologies (17ST6049)
TAP-192-02-01
ASTM D 1970
2015a
PRI Construction Materials Technologies (TST6049)
TAP-193-02-01
ASTM D 1970
2015a
PRI Construction Materials Technologies (TST6049)
TAP214-02-01
ASTM D 4869
2016
PRI Construction Materials Technologies (W6049)
TAP 215-02-01
ASTM D 226
2009
PRI Construction Materials Technologies (rST6049)
TAP 216-02-03
ASTM D 6380
2003(2013)
PRI Construction Materials Technologies (TST6049)
TAP 217-02-01 REV
ASTM D 6380
2003(2013)
PRI Construction Materials Technologies (TST6049)
TAP 216-02-01
ASTM D 226
2009
PRI Construction Materials Technologies (TST6049)
TAP-219-02-01
ASTM D 226
2009
PRI Construction Materials Technologies (I ST6049)
TAP 220-02-01
ASTM D 6380
2003(2013)
PRI Construction Materials Technologies (17ST6049)
TAP 222-02-01
ASTM D 4869
2016
PRI Construction Materials Technologies (TST6049)
TAP-245-02-01
TAS 103
1995
ASTM D 4798
2011
PRI Construction Materials Technologies (TST6049)
TAP-311-02-01
ASTM D 1970
2015a
PRI Construction Materials Technologies (rST6049)
PRI Construction Materials Technologies (TST6049)
TAP-319-02-01.1
TAP-387-02-M
ACC 188
2012
PRI Construction Materials Technologies (TST6049)
TAP-388-02-01
ASTM D 1970
ASTM D 1970
2015a
2015a
UL LLC (TST9628)
13CA12269
ASTM D 226
2009
FL12328-R8
3of4
is evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report Is valid.
'This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
` CREEK
TECHNICAL SERVICES, LLC
COMPLIANCE STATEMENT
TAMKO BUILDING PRODCUTS, INC.
TAMKO Underlayments
The products evaluated herein by Zachary R Priest, P.E. have demonstrated compliance with the Florida Building
Code, a Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer.
rR»A���,i
S4S'.
No 74021
STATE OF
OR IV N
CERTIFICATION OF INDEPENDENCE
2017.10.19
12:15:58
04'00'
Zachary R Priest, P.E.
Florida Registration No. 74021
Organization No. ANE9641
CREEK Technical Services, LLC does not have, nor vn11 it acquire, a financial interest in any company manufacturing or distributing products under this
evaluation.
CREEK Technical Services, LLC is not owned, operated, or controlled by any company menuracturing or distributing products underthis evaluation.
Zachary R. Priest, P.E. does not have, nor vn11 acquire, a financial interest in anycompany manufacturing or distributing products underthis evaluation.
Zachary R Priest, P.E. does not have, nor will acqu!r--a fmandsl interest in arry other entity involved in the approval pmcess cf the product
END OF REPORT
TBP140DI A FL12328-R8 Page 4 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20 3. The manufacturer shall notify CREEK
'Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.