Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL - MODIFIED BITUMENI-lorda Bullding�Code online 8/10/18, 4:50 PM aram ei recce I Publications j Contact us BCIS Site Map ; links ? Search dMr Product Approval USER: Public user Product Approval M nu > Product or Application Search> Application List > Application Detail FL * Application Type Code Version Application Status Comments Archived Product Manufacturer Address/phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/phone/Email :ategory subcategory compliance Method lorida Engineer or Architect Name who developed le Evaluation Report lorida License pality Assurance Entity uallty Assurance Contract Expiration Date alidated By 'rtificate of Independence Terenced Standard and Year (of Standard) FL1654-R22 Revision 2017 Approved POLYGLASS USA ilia W. Newport Center Drive Deerfield Beach, FL 33442 (954) 233-1378 Ext242 alender@poiyglass.com RECEIVED NOV 0 7 2018 ST. Lucie County, Permitting SCANNED BY St Lucie County Ariel Lender alender@polyglass.com J® Q- Maury Alpert 1111 W. Newport Center Dri Deerfield Beach, FL 33442 (912) 429-8610gP MAlpert@polyglass.com OP PC..d Ariel Lender 1111 W. Newport Center Drive Deerfield Beach, FL 33442 (954) 233-1230 ALender@polygiass,com Roofing Modified Bitumen Roof System Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Robert Nieminen PE-59166 UL LLC 10/06/2018 John W. Knezevich, PE J. Validation Checklist - Hardcopy Received FL1654 R22 COI 2017 01 COI Nieminen.pdf Page 1 of 2 ..n,uo ounamg III Online Equivalence of Product Standards Cettifted By Sections from the Code Product Approval Method )ate Submitted )ate Validated )ate Pending FBC Approval )ate Approved Model; Number or°N; L654.1 Polyglass SBS and APP Modified Bitumen Roof Systems imits of Use APProved for use In HVHZ: No pPProved for use outside HVHZ: yes Impact Resistant: N/A Design Pressure: +N/A/-622.5 Dther: 1.) The design pressure in this application !fates to one particular assembly over concrete eck. Refer to the ER Appendix for other systems id deck types, 2.) Refer to ER, Section 5 for other mils of Use. - i Standard ASTM D6162 Year ASTM D6163 2008 ASTM D6164 2008 ASTM D6222 2011 ASTM D6509 2011 FM 4470 2009 FM 4474 2012 UL 1897 2011 2012 Method 1 Option D 09/14/2017 09/15/2017 09/22/2017 12/12/2017 SBS and APP modified bitumen roof systems 8/10/18, 4:50 P! Installation Instructions 1III' 654 R22 11.2017 09 FiNA1 e� co R22 odf ����•�LASS MODBI7 Ft 1654 verified By: Robert Nleminen PE-59166 Created by Independent Third Party: Yes Evaluation Reports F_L1654 R22 AE 2017 09 FINAL ER onnvGLASS MODBIT FL1654 22 df Created by Independent Third Party: yes Back !Ne' COMM US:: 2111 BIalrStone R as T...-.-_ -_ FL-23- Phone•8511-487182a The State of Florida Is an AA/EEO employer ElhmN temen :: BS Slbflily Statement :: gphmd- g� ma r er Florida law, email addresses are public records. If you do not want your e-mait address released In mail to this entity. Instead, contact the ottice by Phone or by traditional mail. If you have a response to o tact es,.4 rds One- The send electronic Ronda S�tutes,- effective October 1, 2032, Iitr�sees i" any Questions, Please ��ct �0.487 y39 � *Pursuant to Section one The emaits provided may be used for official communication licensed licensee.��weyer emaill addresses are rovide e public record. If you do not wish to supply a sonal address, please provide the Department with an email address which can be made available to the public To determ(ne if an email address If they have 455, FS., please click b1M. You are a licensee under Chapter Product Approval Accepts~ Credit , secu ri t��ati:�r. lttcs Page 2 of 2 ,"f B RINSTYIERD Table Deck 1A Wood ..Application ,.,:: Type i. � .,::: i '; Description '• w , , . ; . . 18-1 Wood New or Reroof (Tear Off) A 1 NeW or Reroof (Tear -Off) Bonded Insulation, Bonded Roof Cover Page iB-2 Wood q.2 New, Reroof (Tear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 5 iC Wood New, Reroof (Tear -Off) or Recover B Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 5-9 iD Wood New, Reroof (Tear -Off) or Recover C Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 10-11 1E Woad New, Reroof (Tear -Off) or Recover Mech. Attached Insulation, Bonded Roof Cover 11 1F-1 Wood D New or Reroof (Tear -Off) E Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover 12-13 iF 2 Wood New, Reroof (Tear -Off) or Recover E Non -Insulated, Mech. Attached Base Sheet (nails), Bonded Roof Cover 14-15 iG Wood New or Reroof (Tear -Off) F Non -Insulated, Mech. Attached Base Sheet (screws & plates), Bonded Roof Cover i6-18 2A Steel or Structural concrete New, Reroof (Tear -Off) or Recover B Non -Insulated, Bonded Roof Cover 19-21 2B Steel or Structural concrete New, Reroof (Tear -Off) orRecover C Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 21 2C Steel or Structural concrete New, Reroof (Tear -Off) orRecover D Mech. Attached Insulation, Bonded Roof Cover 22-24 3A Structural concrete New or Reroof(Tear-Off) A-1 Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover 25-28 3B Structural concrete New or Reroof (Tear -Off) Bonded Insulation, Bonded Roof Cover 29-31 4A LWIC p New or Reroof {Tear -Off) A-1 ulatedB Non -Ins, onded Roof Cover 32-40 4B LWIC New or Reroof (Tear -Off) Bonded Insulation, Bonded Roof Cover 4C LWIC A-2 New or Reroof (Tear�Off) E Mech. Attached Anchor Sheet, Bonded lation, nded Roof Cover InsuBo 41-42 5A CWF New or Reroof (Tear -Off) q_i Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 43 5B CWF New, Reroof (Tear-0ff) orRecover A-2 Bonded Insulation, Bonded Roof Cover 44-46 Sc CWF 5D CWF New, Reroof (Tear -Off) orRecover g New, Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover Mech. Attached Base Insulation, Bonded Top Insulation, 47 � SE CWF Reroof (Tear -Off) or Recover C Bonded Roof Cover Mech. Attached Insulation, Bonded Roof Cover 49 6A Gypsum New, Reroof (Tear -Off) orRecover E Reroof (Tear-Oft) Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 49 6B Gypsum A-i Reroof (Tear-Off) or Recover l Bonded Insuation, Bonded Roof Cover 49 6C Gypsum A-2 Reroof (Tear -Off) or Recover C Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 50.52 6D Gypsum Reroof (Tear -Off) or Recover Mech. Attached insulation, Bonded Roof Cover 52 7A Various E Recover Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 53 78 Various A-1 Bonded Insulation, Bonded Roof Cover 53 .Recover ---J F The followin¢ notes aonly to the systems outlined herein; Non -Insulated, Bonded Base Sheet, Bonded Roof Cover 5458 58 1. The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 2. Insulation / base sheet fasteners shall be of sufficient length for the following deck engagement: Jurisdiction. D Wood: Minimum 0.75-Inch penetration. t Steel: Minimum 0.75-Inch penetration and engage the top flute of the steel deck. > Structural concrete: Minimum i-Inch embedment into pilot hole In 3. Unless otherwise noted, insulation may be accordance with fastener manufacturer's any published installation Instructions. one layer or combination of poiyisocyanurate, polystyrene, wood fiberboard, perilte, gypsum -based roof board or mineral -wool roof board that meets the QA requirements of F.A.C. Rule 61620-3 and Is documented as meeting FBC 1505.1 and, for foam plastic, FBC Chapter 260 when Installed with the Exterior Research and Design, LLC, d/b/a Trinity) ERD roof cover. Certificate-of Author— - -- - -- — y: RobertiN ieminf9503— � •� Prepared by: Robert Niemtnen, PE-59166 6T"EDITION (2017) FBC NON-HVHZ EVALUATION Evaluation Report P9290,02.08-R20 for FL3654-R22 - Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Revision 20: 09/12/2017 Appendix 1, Page 1 of 58 ' SY$TEM TABLE iF2 WOOD DECKS NEUV CONSiRUCT10N, REROOF (TEAR-OFF)DR REcoVER fYPE E NON INSULATED, TRININ 7777 ERD System NIECHANIGALLYATTi4CHEDBASE SHEET (sCREws& PLATgSj BpNDEU'ROOF COVER Deck (Note 1) Base Sheet No type (Note 15) Fasten Roof Cover MOP �iSELFADHERINpBASE:iP,LY w _,;�' -'i ., Attach Base Ply Can (Psf) W-136 MIn.19/32- Inch plywood r. a. t.. Elastobase, Elastobase P Dekfast Hex (aka, Dekfast PLT H-2-7/8) with Dekfast qi4 12-Inch o.c. in 4•Inch lap and 12•tnch o.c. In two (poly-flim top) ' L. MIn.19/32- Elastobase, Elastobase or Trufast 3" Metal Insulation Plate with Trufast HD red center rowsSBS•SA P lc SOS -SA, APP-SA, SBS- -52.5 W-137 Inch plywood Dekfast Hex (aka, Dekfast PLT-H•2-7/8) with Dekfast #14 124nch o in 41nch lap and 12-I ch o.c. In two (poly -film top) or Trufast 3" Metal Insulation Plate with Trufast HD TA, APP-TA W-138 Min.19/32- (2), equally spaced, staggered center rows Polyflex SA Base Elastobase, Elastobase P APP-TA -52.5' Inch plywood (poly -film top) OMG Flat Bottom Plates (square) with Roofgrlp #12 12-inch o.c. In 4-Inch lap and 12•inch oc, In two W-139 Min.19/32- Elastobase, Elastobase P (2), equally spaced, staggered center rows SOS -SA SBS SA , , APP-SA SBS- TA, APP-TA -60.0• Inch plywood (poly -firm top) OMG Flat Bottom Plates (square) with Roofgrlp #12 12-inch o.c. In 4-Inch lap and 12-Inch o.c. in two (2), equally spaced, staggered center rows Polyflex SA Base APP-TA -60 0• TABLE 1G WOAD"DECKS ::NEW CONSTRUCTION OR REROOF (TEAR OFF)'" SYSTEM TYhE F NON INSLIL TED, BON. ED.RO.OF CO}/ER System No. Deck (Note i) Primer Roof Cover (Note 15) - 40 Min, 15/32- None Joint Treatment Base Ply Cap ply MDP (PSI) Ply Inch plywood None SOS , (Optional) SB , S85• Sg5-SA, APP. _ SBS- W-141 15/32. Inch plywood Min.plywoood (Optional) PG100 None TA, APP-TA TA, APP-TA -90.0 • W-142 Polyflex SA Base (Optional) APP-TA APP-TA 90.0 Min.15/32- Inch plywood pG100 None SBS-SA (Optional) SBS-SA, SBS- SBS•SA, APP-SA, SOS - W-143 Min. iS/32- inch plywood (Optional) PG100 Plywood Joints are covered with 4-Inch wide strips of Elastoflex SA V Plus, rolled Into Elastoflex SA V Base TA, APP-TA TA, APP-TA •97.5 or place to create continuous bond. Elastoflex SA FIR Base (Optional) SBS•SA, SBS- TA, APP•TA SBS-SA, APP-SA, SBS- -97.5 Min. is/32- W144 Inch plywood W8-3000 No TA, APP-TA W-14S S8S-SA Plywood joints are covered 4-Inch wide strips of Elastoflex (Optional) SBS•SA, APP•SA, SBS- TA, APP-TA -10S.0 MIn.15/32- (Optional) PG100 Inch plywood p SA V Plus, rolled Into Elastoflex SA V Plus or place tocreate continuous bond. (Optional) SBS SA, SBS- SBS SA APP•SA, SBS W-146 Min.15/32- Inch plywood (Optional)"PG100 Elastoflex SA us FR Plywood Joints are covered wkh 4•inch wide strips of Elastoflex SA V Plus, rolled Into TA, APP•TA TA, APP-TA -135.0 place to create continuous bond, Polyflex SA Base (Optional) APP-TA APP•TA -135.0 Exterior Research and Design, I.I.C. d/b/a Trinity( ERD Certiflcate.of Authorization #9503 6 EDITION (2017) FBC NON-HVHZ EVALUATION Evaluation Report P9290.02,08-R20 for FL16S4-R22 +, Prepared by: Robert Nleminen, PE-59166 POlygiasS Modified Bitumen Roof Systems; (S70) 384-1230 Revision 20: 09/12/2017 Appendix 1, Page 21 of 58