HomeMy WebLinkAboutPLANSPREVISIONS IBYI --NOTE-& * ALL RECEPTACLES INSTALLED OUTDOORS, IN GARAGE, OR IN BATHROOMS MUST HAVE GROUND FAULT CIRCUIT INTERRUPTER. * SMOKE DETECTORS SHALL BE 120 VOLT T-1'PE-W/"P-O_WER_0_N INDICATOR", A TEST BUTTON AND A BATTERY BACK-UP. * SMOKE DETECTORS SHALL BE LOCATED IMMEDIATELY OUTSIDE EACH SLEEPING AREA. * SMOKE DETECTORS SHALL 5E HARDWIRED TO A NONSWITCHABLE BEDROOM LIGHTING CIRCUIT AND SHALL NOT BE WIRED TO THE LOAD SIDE OF ANY G.F.I. OUTLET CIRCUIT AND ARE TO BE A.F.C.I. CODED PER NEC 210.12 * ALL BEDROOMS TO BE A.F.C.I. CODED. * ALL B 4 20 amp OUTLETS TO 5E A.F.C.I. CODED. * ALL 15 4 20 amp OUTLETS TO BE TAMPER RESISTANT. ADHESIVE APPLIED CERAMIC TILE ON 5/8" WATER RESISTANT GYPSUM WALLBOARD SCREWED TO GALV. METAL STUDS AT I6"O.C. HOLD GYPSUM WALLBOARD MIN. 1/4" ABOVE SHOWER RECEPTOR AS INDICATED P.T. NOMINAL Ix8 WOOD BACKING BETWEEN STUDS CONTINUOUS SEALANT GALV. METAL LATH STRIP CERAMIC TILE SET IN FULL MORTAR BED SLOPED TO DRAIN 11-112111:ri v . a wd" Zia MIL. VINYL SHOWER PAN - EXTEND UP WALL MIN. 6" CONCRETE FLOOR SLAB &HOWER PAN DETAIL WIRE NEW ELECTRICAL TO EXI5TING PANEL. ADDITIONAL LOAD DOE5 NOT EXCEED PANEL CAPACITY. REVIEWED FOR REVIEWED BY_ DATE_Ni BP.DROOM GREAT ROOM KITCHEW BREAKFAST NS AND PEF OR NO IN BEDROOM 2 3T BE KEPT ON JOB N(S) WILL BE MADE �NTRY FOYiR BEDROOM 5 WORK NOTES: I. EXISTING STRUCTURE TO REMAIN. THIS IS A RENOVATION OF MASTER BATH ONLY_ 2. EXISTING LIGHTING TO REMAIN. INSTALLATION OF NEW OUTLETS AS SHOWN 3. EXISTING SHOWER TO BE RETILED. INSTALL NEW SHOWER VALVE WITH DIVERTER AND RAINHEAD. BATHTUB TO REMAIN. 4. EXISTING TOILET TO BE REPLACED 4 -12