HomeMy WebLinkAboutENERGY EFFICIENCY CODE FILE COPYFORM IR405-2017
I
,FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: HENNE THE IMPACT
Builder WYNNE ENT
SCANNED
RINDSOR
StreCity,
Permit Office:. E COUNTY
BY
Stal, Zip: FT. PIERCE , FL
Owner: ����t� ��("�
Permit Number:
Jurisdiction:
St Lucie County
Design Location: FL, Fort Pierce
County:: St. Lucie (Florida Climate Zone 2 )
i
1. New construction or existing New (From Plans)
9. Wall Types (1432.0 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1 1224.00 ft2
3. Number of if family 1
b. Frame - Wood, Adjacent
R=11.0 208.00 ftz
units, multiple
c. N/A
R= ft2
.4. Number of Bedrooms 3
d. N/A
R= ft2
I
10. Ceiling Types (1753.0 sqft.)
Insulation Area
5. Is this a worst case? Yes
a. Under Attic (Vented)
R=30.0 1753.00 ft2
6. Conditiored floor area above grade (ft2) 1753
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c.
R= ft2
11. Ducts
R ft2
7. Windowsl051.4 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 225
a. U-Factor: Sgl, U=0.63 111.36 ft2
SHGCr SHGC=0.25
b. U-Factjor: Sgl, U=0.65 40.00 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC SHGC=0.21
a. Central Unit
34.8 SEER:15.00
c. U-Factor: N/A ft2
SHGC
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Heat Pump
34.8 HSPF:8.50
SHGC
Area Weighted Average Overhang Depth: 2.850 ft.
Area Weighted Average SHGC: 0.239
14. Hot water systems
a. Electric
Cap: 40 gallons
8. Floor Types (1753.0 sqft.) Insulation Area
EF: 0.970
a. Slab -Or, -Grade Edge Insulation R=0.0 1763.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
Pstat
Glass/Floolr
Area: 0.086 Total Proposed Modified Loads: 53.83
PASS
Total Baseline Loads: 53.85
I
1 hereby certify that the plans and specifications covered by
Review of the plans and
4-gE S�'q?'
this calculation are in compliance with the Florida Energy
specifications covered by this
Code.
calculation indicates compliance
,�.•�`
<O
ao
with the Florida Energy Code.
h ur,''w •.:',,•;.�.��,<
PREPARE B
DATE:
Before construction is completed
this building will be inspected for
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
1 6�
with the Flori Ida Energy Code.
G'0 q�
OWNER/ qGE
BUILDING OFFICIAL:
DATE: ;\
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope le�kage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
BILE &m
4/16/2018 8:22 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software
i
Page 1 of 5
i
FORM R465-2017
PROJECT
Title: WYNNE THE WINDSOR IM
Bedrooms: 3
Address Type:
Street Address
Building Type: User
Conditioned Area: 1753
Lot #
Owner Name:
Total Stories: 1
Block/Subdivision:
# of Units: 1
Worst Case: Yes
PlatBook:
Builder Name: WYNNE DEVELOPMENT
Rotate Angle: 225
Street:
THE WINDSOR
Permit Office: ST. LUCIE COUNTY
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
Whole House Fan: No
City, State,
Zip:
FT. PIERCE,
Family T}ipe: Single-family
FL,
New/Existing: New (From Plans)
Comment:
I
CLIMATE
V
Design Location TMY Site
Design Temp
97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 39
90
70
75
299
62
Low
BLOCKS
Number) Name Area
Volume
i
1 I Entire House 1753
14024
SPACES
Number
Name Area
Volume Kitchen Occupants
Bedrooms
Infil ID
Finished Cooled
Heated
I
1 MASTER BEDROO 224
1792 No
0
1
1
Yes
Yes
Yes
2 WIC 63
504 No
0
1
No
Yes
Yes
3 MASTER BATH 56
448 No
0
1
Yes
Yes
Yes
4 M.BATH 61
488 No
0
1
Yes
Yes
Yes
5 LAUDRY 36
288 No
0
1
No
Yes
Yes
6 BEDROOM 2 180
1440 No
0
1
1
Yes
Yes
Yes
7 DINING/GREAT R 588
4704 No
2
1
Yes
Yes
Yes
8 I KITCHEN 209
1672 Yes
0
1
Yes
Yes
Yes
9 i BATH 50
400 No
0
1
Yes
Yes
Yes
10 HALL 25
200 No
0
1
No
Yes
Yes
11 FOYER 92
736 No
0
1
Yes
Yes
Yes
12 I BEDROOM 3 169
1352 No
0
1
1
Yes
Yes
Yes
FLOORS
#
Floor Type Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio MASTER
BEDRO 37 ft 0
224 ftZ
----
0 1
0
I
2 Slab -On -Grade Edge Insulatio WIC
1 ft 0
63 ftZ
---
0 1
0
3 Slab -On -Grade Edge Insulatio MASTER BATH 8 ft 0
56 ftZ
----
0 1
0
i
4SIab-On-Grade Edge Insulatio M. BATH 7 ft 0
61 ftz
----
0 1
0
I
5 Slab -On -Grade Edge Insulatio tAUDRY 1 ft 0
36 ftZ
----
0 1
0
1
4/16/2018 8:22 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 5
FORM R405-2017
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
6 Slab -On -Grade Edge Insulatio
BEDROOM 2 12 ft
0
180 ft2
----
0
1
0
7 Slab -On -Grade Edge Insulatio
DINING/GREAT 50 ft
0
588 ft2
----
0
1
0
8SIab-On-Grade Edge Insulatio
KITCHEN 11 ft
0
209 ft2
----
0
1
0
1 9 Slab -On -Grade Edge Insulatio
BATH 5 ft
0
50 ft2
----
0
1
0
110SIab-On-Grade Edge Insulatio
HALL 1 ft
0
25 ft2
----
0
1
0
111SIab-On-Grade Edge Insulatio
FOYER 9 ft
0
92 ft2
----
0
1
0
I12SIab-On-Grade Edge Insulatio
BEDROOM 3 14 ft
0
169 ft2
----
0
1
0
i
ROOF
v
Roof
Gable
Roof
Solar SA
Emitt
Emitt
Deck
Pitch
1# Type Materials Area
Area
Color
Absor. Tested
Tested
Insul.
(deg)
1 Gable or Shed
Metal 1847 ft2
292 ft2
Light
0.6
No
0.9
No
0
18.4
ATTIC
V # Type
Ventilation
Vent Ratio (1
in)
Area
RBS
IRCC
0 Full attic
Vented
150
1753 ft2
N
N
CEILING
# Ceiling Type
Space
R-Value
Ins Type
Area
Framing Frac Truss Type
Under Attic (Vented)
MASTER BEDRO
30
Blown
224 ft2
0.1
Wood
2 Under Attic (Vented)
WIC
30
Blown
63 ft2
0.1
Wood
3 Under Attic (Vented)
MASTER BATH
30
Blown
56 ft2
0.1
Wood
4 Under Attic (Vented)
M. BATH
30
Blown
61 ft2
0.1
Wood
5 Under Attic (Vented)
LAUDRY
30
Blown
36 ft2
0.1
Wood
I
6II Under Attic (Vented)
BEDROOM 2
30
Blown
180 ft2
0.1
Wood
7 Under Attic (Vented)
DINING/GREAT
30
Blown
588 ft2
0.1
Wood
8I Under Attic (Vented)
KITCHEN
30
Blown
209 ft2
0.1
Wood
9 Under Attic (Vented)
BATH
30
Blown
50 ft2
0.1
Wood
10 Under Attic (Vented)
HALL
30
Blown
25 ft2
0.1
Wood
11I Under Attic (Vented)
FOYER
30
Blown
92 ft2
0.1
Wood
12 Under Attic (Vented)
BEDROOM 3
30
Blown
169 ft2
0.1
Wood
WALLS
Adjacent
apace Cavity Width
Ee
Height
Sheathing Framing
Solar
Below
1 NE=>W
Exterior Concrete Block - Ext InsMASTER BE
4.1 16
0 8
0
128.0 ft2
0
0
0.5
0
2 SW
j>E Exterior Concrete Block - Ext InsMASTER BE
4.1 7
0 8
0
56.0 ft2
0
0
0.5
0
3 NW
l>S Exterior Concrete Block - Ext InsMASTER BE
4.1 14
0 8
0
112.0 ft2
0
0
0.5
0
4 NE=
W Exterior Concrete Block - Ext InddWSTER BA
4.1 8
0 8
0
64.0 ft2
0
0
0.5
0
4/16/2018 8:22 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 5
I
I
PnRM Rdnri-7n17
WALLS
Adjacent
Cavity Width
Height
Sheathing Framing
Solar
Below
# Ornt
In
Space
Wall Type
5 NE=>W
Exterior
Concrete Block - Ext InsuM. BATH
4.1 7
0
8 0
56.0 ft2
0
0
0.5
0
I
_ 6 NE=>W
Exterior
Concrete Block - Ext InQEDROOM 2
4.1 12
0
8 0
96.0 ft2
0
0
0.5
0
I
7 Sr=>E
Exterior
Concrete Block - Ext Ind0NNING/GRE
4.1 30
0
8 0
240.0 ft2
0
0
0.5
0
_ 8 NW=>S
Exterior
Concrete Block - Ext IndXNING/GRE
4.1 20
0
8 0
160.0 ft2
0
0
0.5
0
I
_ 9 SW=>E
Exterior
Concrete Block - Ext InsuKITCHEN
4.1 11
0
8 0
88.0 ft2
0
0
0.5
0
I
_ 10 NE=>W
Exterior
Concrete Block - Ext Insul BATH
4.1 5
0
8 0
40.0 ft2
0
0
0.5
0
I
11 SE=>N
Exterior
Concrete Block - Ext Insul FOYER
4.1 8
0
8 0
64.0 ft2
0
0
0.5
0
_
12 SW=>E
Exterior
Concrete Block - Ext Insul FOYER
4.1 1
0
8 0
8.0 ft2
0
0
0.5
0
13 NE=>W
i
Exterior
Concrete Block - Ext In&EDROOM 3
4.1 13
0
8 0
104.0 ft2
0
0
0.5
0
14 SW=>E
Exterior
Concrete Block - Ext InfiEDROOM 3
4.1 1
0
8 0
8.0 ft2
0
0
0.5
0
_
_ 15 N
>SW
Garage
Frame - Wood BEDROOM 3
11 26
8
208.0 ft2
0.23
0.5
0
DOORS
1#
Ornt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
11
SE=>N Insulated FOYER
None
.39
3
3
6 8
21.7 ft2
WINDOWS
Orientation shown is the entered orientation => changed to Worst Case.
Wall
Overhang
�/ #
Ornt ID
Frame Panes NFRC U-Factor
SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
NW=>S 3
Metal Low-E Single Yes
0.63 0.25
N
32.4 ft2
1 ft 0 in
1 ft 4 in
Drapes/blinds
Exterior 5
2
NE=>W 5
Metal Low-E Single Yes
0.63 0.25
N
6.9 ft2
1 ft 0 in
1 ft 4 in
None
None
3
NE=>W 6
Metal Low-E Single Yes
0.63 0.25
N
16.2 ft2
1 ft 0 in
1 ft 4 in
None
None
4
SW=>E 7
Metal Low-E Single Yes
0.63 0.25
N
39.8 ft2
1 ft 0 in
1 ft 4 in
None
None
5
NW=>S 8
Metal Low-E Single Yes
0.65 0.21
N
40.0 ft2
8 ft 0 in
1 ft 4 in
None
None
6
NE=>W 13
Metal Low-E Single Yes
0.63 0.25
N
16.2 ft2
1 ft 0 in
1 ft 4 in
Drapes/blinds
Exterior 5
GARAGE
#
Floor Area Ceiling Area Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
I
806 ft2 806 ft2
26 ft
8 ft
11
INFILTRATION
# Scope
I
Method SLA CFM 50 ELA
EgLA
ACH
ACH 50
1 Wholehouse
Proposed ACH(50) .000356 1636.1 89.82
168.92
.2598
7
1
4/16/2018 8144 PM
EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software
Page 4 of 5
FORM R405-2017
HEATING SYSTEM
#
System Type
Subtype
Efficiency
Capacity
Block
Ducts
1
Electric Heat Pump/
Split
HSPF:8.5
34.8 kBtu/hr
1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Efficiency
Capacity
Air Flow
SHR
Block
Ducts
I
1
Central Unit/
Split
SEER: 15 34.8 kBtu/hr cfm
0.85
1
sys#1
HOT WATER SYSTEM
I#
System Type
SubType
Location
EF Cap Use
SetPnt
Conservation
I
1
Electric
None
Garage
0.97 40 gal 60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert
# Company Name
System Model # Collector Model
# Area
Volume
FEF
None None
I
ft2
DUCTS
/
— Supply ---
— Return --
Air
CFM 25
CFM25
HVAC #
V #
Location R-Value Area
Location
Area Leakage Type
Handler
TOT
OUT
QN
RLF
Heat Cool
1
Attic
6 225 ft2
Attic
65 ft2 Default Leakage
Attic
(Default) (Default)
1 1
TEMPERATURES
Programable
Thermostat: Y
Ceiling Fans:
CoolingJan
Heatin
HJan
Feb
HFeb
Mar
Mar
[ ] Apr [
[ ] Apr [
May [X Jun [X] Jul
May [ Jun [ ] Jul
[ ] Au
rj AugJXJ
Se
Sep
[ ]
[ ]
Oct
Oct
Nov
Nov
H
H Dec
Dec
Ventin
Jan Feb
X Mar
[X] A r [
Ma [ Jun [ ] Jul
[ ] Au
Se
[X]
Oct
Nov
Dec
Thermostat
Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2 3
4 5 6
7
8
9
10
11
12
Cooling (WD)
AM
78
78 78
78 78 78
78
78
80
80
80
80
PM
80
80 78
78 78 78
78
78
78
78
78
78
Cooling (WE H)
AM
78
78 78
78 78 78
78
78
78
78
78
78
PM
78
78 78
78 78 78
78
78
78
78
78
78
Heating (WD)
AM
66
66 66
66 66 68
68
68
68
68
68
68
I
PM
68
68 68
68 68 68
68
68
68
68
66
66
Heating (WEFT)
AM
66
66 66
66 66 68
68
68
68
68
68
68
PM
68
68 68
68 68 68
68
68
68
.68
66
66
4/16/2018 8:4I PM EnergyGaugeg) USA - FlaRes2017 Section R405.4.1 Compliant Software
I
Page 5 of 5
I
.I
2017 ! AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE THE WINDSOR IMPACT Builder Name: WYNNE DEVELOPMENT
Street: THE WINDSOR Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Owner: Jurisdiction:
Design Location: FL, Fort Pierce
COMP-, ONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General I
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
I
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
the insulation and an in the air barrier shall be sealed.
The insulation in any dropped ceiling/soffit
I
gaps
Y 9 P
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity with
sealed.
a material having a thermal resistance of,R-3 per inch
Knee walls shall be sealed.
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows) skylights
The space between window/door jambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists)
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors I
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls
Shafts, pen, etrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
I
Batts in narrow cavities shall be cut to fit, or narrow
Narrow ca lities
cavities -shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spac
3s.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing a%d wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extpnd behind popang and wiring-
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/pf Ione box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
I
sealed in a manner that is recommended by the manufacturer.
- - - --
I
---- -
Caulking or other adhesive sealants shall not be used to fill voids
between fire sprinkler cover plates and walls or
- - -
a. ui auuuion,lunspeonon of mg walls snail De in accordance with the provisions of IGG-4u0.
4/16/2018 8:53 PM EnergyGaugeO USA - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
I
I
i
,FORM R405-2017
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 100
The lower the EnergyPerformance Index, the more efficient the home.
THE WINDSOR, FT. PIERCE, FL,
1. New construction or existing
New (From Plans)
9. Wall Types
Insulation
Area
2. Single family or multiple family
Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1
1224.00 ftz
b. Frame - Wood, Adjacent
R=11.0
208.00 ftz
3. Number of units, if multiple family
1
c. N/A
R=
ftz
4. Numbei of Bedrooms
3
d. N/A
R=
ftz
5. Is this a worst case?
Yes
10. Ceiling Types
Insulation
Area
a. Under Attic (Vented)
R=30.0
1753.00 ftz
6. Conditioned floor area (ftz)
1753
b. N/A
R=
ftz
c. N/A
R=
ft z
7. Windo s-- Description
Area
1
a. U-Factor: Sgl, U=0.63
111.36 ftz
11. Ducts
R ftz
a. Sup: Attic, Ret: Attic, AH: Attic
6 225
SHGC: SHGC=0.25
b. U-Factor: Sgl, U=0.65
40.00 ftz
SHGC: SHGC=0.21
12. Cooling systems
kBtu/hr
Efficiency
c. U-Factor: N/A
ftz
a. Central Unit
34.8 SEER:15.00
SHG9:
d. U-Factor: N/A
ftz
SHGC:
13. Heating systems
kBtu/hr
Efficiency
Area Weighted Average Overhang Depth:
2.850 ft.
a. Electric Heat Pump
34.8
HSPF:8.50
Area Weighted Average SHGC:
0.239
8. Floor Types Insulation
Area
14. Hot water systems
Cap:
40 gallons
a. Slab -On -Grade Edge Insulation R=0.0
1753.00 ftz
a. Electric
EF: 0.97
b. N/A R=
ftz
c. N/A R=
ftz
b. Conservation features
None
15. Credits
Pstat
I
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on in Code compliant features.
Builder Sign ature: Date:
Address of New Home:\Cam\ C' City/FL Zip: E pTCe
*Note: I This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at
techsuFport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of
certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building
Commission's support staff.
required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
4/16/2018 8:53 PM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1