Loading...
HomeMy WebLinkAboutPROJECT SUMMARYi Job: -- wrightsoft° Project Summary Date: Entire House By: QUICK CALLS, INC. For: YNNE W NDSOR DEVELOPMENT THE PIERCE, FL SCANNED BY Notes: `� \�` ��` \ St Lucie County Weather. Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside.db 75 OF Design TD 28 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 18467 Btuh Structure 17655 Btuh Ducts 6190 Btuh Ducts 9340•_Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 ,,Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 24657 Btuh Use manufacturer's data n Rate/swingg multiplier 0.95 Infiltration Equipment sensible load 25645 Btuh Method Simplified Latent Cooling Equipment'Load Sizing Construction quality Average Fireplaces 0 Structure 2453 Btuh Ducts 2554 Btuh Central vent (0 cfm) 0 Btuh Heatingg Coolin (none) Area (ftz) 1753 1759 Equipment latent load 5007 Btuh Volume (ft3) 14741 14741 Air changes/hour 0.38 0.20 Equipment total load 30652 Btuh Equiv. AVF (cfm) 93 49 Req. total capacity at 0.70 SHR 3.1 ton I Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIER AIR CONDITIONING Trade CARRIERAIR CONDITIONING Model 25HBC536A*030 Cond 25HBC536A*030 AHRI ref 7914585 Coil FX4DN(B,F)037 AHRI ref 7914585 Efficiency 8.5 HSPF Efficiency 12.0 EER, 15 SEER Heating input Sensible cooling 24360 Btuh Heating output 34600 Btuh @ 47°F Latent cooling 10440 Btuh Temperature rise 27 T Total cooling 34800 Btuh Actual air flow 1160 cfm Actual air flow 1160 cfm Airflow factor 0.047 cfm/Btuh Airflow factor 0.043 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.84 Capacity balance point = 34 OF Backup: Input = 7 kW, Output = 23009 Btuh, 100 AFUE FILt ?018 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrightsoft` 2017-Apr-10 17:19:28 Right-Suite(g)Universal 2017 17.0.14 RS1108101 Page 1 k CalcsWocuments\WYNNE-THE WINDSOR-REVISED.rup Calc = MJ8 Front Door faces: N i ` I -'F wrlphtsoft- Right-M Worksheet Job: Entire House Date: By: QUICK CALCS, INC. i 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772.466-6796 Email; QUICKCALCS@AOL,COM 1 Roo lm name Entire. House MASTER BEDROOM 2 Ems' ed wall 153.0 ft 45.0 ft 3 Raom height 8.4 ft d 8.0 ft heaticool 4 Room dimensions 1.0 x 280.0 ft 5 Room area 1753.0 ft2 280.0 ft2 Ty Construction U-value Or HTM Area (ftz) Load Area (ftz) Load number (Btuh/ftz--°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 I N 13A-4ocs 0.143 ne 4.00 2.55 486 448 1795 1141 192 192 '769 489 AX-clorns 1.270 ne 35.56 70:43 7 0 247 488 0 0. 0 '0 9Ac1om.: -1,270 ne 3556 70.43 ' 16 0 581 1151 0 " • :0 . ; . 0 0 1A-c1om .. T:270 ne 35:56 45;24. 16 . 0 581 739 ..: 0 . 0 . 0 ` 0 1 D 13A-4ocs 0.143 se 4.00 2.55 64 41 165 105 0 0 0 0 11D0 0.390 se 10.92 11.31 23 23 248 257 0 0. 0 0 V)r 13Aflocs. 0.143 sw 1 4:00 255. .437 ,396 1584' 1007 `. 56 56 224, 1:43 AA5-2om '. O:TIO aw 21.56 27s53 41 45 893 1140 0 0. 0 - 0 V�1 13A-4ocs 0.143 nw 4.00 . 2.55 290 217 867 551 .• 112 79 318 202 1Ac1om 1.270 nw 35:56 45.24 33 0 1162 1478 33 0 1162 1478 L�_-GG 4A5.2omd 0.770 21.56 36.90 41, 0 880 1505 0 0 0 0 P , 0.091 .nw ; - : 2.55 1 28 308 . - -308 . 784 ` .... 395 .: '0 '0 0 0 C I 16A-30md 0.032 - 0.90 2.32 1753 1753 1571 4067 280 280 251 650 F I I i 22A tpl . 0.989. - : 27.60 0.00 1753: 153, 4237 0 280 ". 45 1246 - 0 is 6 c)AED oxursion 1360 600 Envelope loss/gain 15594 15385 3970 3561 12 i a) Infiltration 2873 810 809 228 b) Room ventilation 0 01 0 0 13 Internal gains: Occupants @ 230 2 460 0 0 Appliances/other 1000 0 Subtotal pines 6 to.13) 18467 17655 4779 3789 Less Wernal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 18467 17655 4779 3789 15 Duct loads 34% 53% 6190 9340 34% 53% 1602 2005 i Total room load 24657 26995 6380 5794 Air required (cfm) 1160 1160 1300 249 Calculations +44- wrightsoft, Right -Suite® Universal 2017 17.0.14 RSU08101 ... k CalcslDocuments\WYNNE-THE WINDSOR-REVISED.rup Calc = MJ8 Front Door faces: of Manual J.8th 2017-Apr-10 17:19:28 Page 1 i -- wrightsofts i Right,M) Worksheet Entire House QUICK CALLS, INC. 317 ST. LUCi IE LN., FT. PIERCE, FL 34946 Phone: 772466-6799 Fax 772-466-6796 Email: OUICKCALCS@/AOL.COM Job: Date: By: 1 2 Room name Bxposed wall WIC 0 ft M. BATH 7.0 ft 3 Room height 8.0 ft heaticool 8.0 ft heat/cool 4 5 Room dimensions Room area 7.0 x 9.0 ft 63.0 ftz 1.0 x 61.0 ft 61.0 ftz Ty ` Construction U-value Or HTM Area (ftz) Load Area (ftz) Load number (Btuh/ft'L-°F) (Btuhlftz) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross WP/S Heat Cool 6 i W, 13A-4ocs 1A-c1om 0.143 1.270 ne ne 4.00 35.56 2.65 70.43 0 0 0 0 0 0 0 -0 56 7 49 0. 196 247 125 4.88 1Ac1om • . 1;270 . ne 3556 70.43 ; 0 0 0 0 0 0 0 . 0. 1Ac1om. 1:270.. ne 35;56 45i24 . 0 0 0 0 0 0; ;0 0 11 W D 13AAocs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 11DO 13A4ocs.- 4A54om • "' 0.390 0.143 :0.770 se sw sw; 10.92 4:00' 21 56. 11.31 255 27.53 0 6 0 0 -. 0 0 0 - 0 0 0.- ; 0, 0 0 : .. 0 0 0 0.• , 0 0 0 '•0 0 0 0 U�! 13A4ocs 1Ac1om 0.143 1.270 nw nw 4.00 35.56 2.55 45.24 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4A5-2omd 0.770 0:091 nw • .- 21.56 2.55 36.90 ' - 1'.28 0 0 0 0 0 0 0 . 0 0 0 0 0 0 0 0 . ; . 0 P=' . "r':126-0"sw C 16A 30md 0.032 0.90 2.32 63 63 56 146 61 61 55 142 F i I .i 22A7tpl : 0:989 27.69 0.00 .63 0 0 : 6 :61 . 7 194' : " 0 6 c)!AED excursion -5 -26 FJivelope loss/gain 56 141 692 729 12 a) Infiltration b)� Room ventilation 0 0 0 0 126 0 35 0 13 Internal gains: Occupants @ 230 0 0 0 0 ! Appliances/other 0 0 Subtotal pines 6 to 13) 56 141 817 764 14 15 Less external load Less transfer Rbdistribution Subtotal Duct loads 34% 53% 0 0 0 56 19 0 0 0 141 75 34% 53% 0 0 0 817 274 0 0 0 764 404 Total room load Ajr required (cfm) 75 4 216 9 1 1091 51 1168 50 i -+ wrightsoft' I Right-J® Worksheet Job: Entire House Date: QUICK CALCS,INC: BY: 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name LAUDRY BEDROOM 2 2 , BWsed wall 0 ft 12.0 ft 3 Roo{n height 8.0 ft heat/coot 8.0 ft heaUcool 4 Room dimensions 6.0 x 6.0 ft 15.0 x 12.0 ft 5 Room area 36.0 ft2 180.0 ft2 TY Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft'L-`F) (Btuhlft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross WP/S Heat Cool Gross N/P/S Heat Cool 6 . .13A4ccs 0.143 ne .4.00 2-55 0 0 0 • 0 96 80 . 319, 203 1Aclom 1;270 ne. 3556 70:43 "• 0 0 0 0 0 0. Q: 0 1A-c1om 1:270 ne. 3556, 70.43- :0 0 0 0 16 .; 0: 581` 115T AKA iom . 1:270 . ne .35i56 45.24 = 0 . 0 0 :: 0 0 0 : U 0 1---D 13A�ocs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 11DO 0.390 se 10.92 11.31 0 0 0. 0 0 0 0 0 yJ 13A flocs -:- , :. 0.143 sw ; 4:00, 2:55 :. 0 0 - .: 0 = 0 0 .. 0 . 0 0 G` AA5-2om.. Oi770 sw: 21:56. 27:53 0 0 p .. :0 0 0:. 0 : D 13AAocs 0.143 nw 4.00 2.55 0 0 0 0 0 0 0 0 1A-c1om 1.270 nw 35.56 45.24 0 0 0 0 0 0 0 0 r--G 4A5-2omd 0.770 nw 21.56 36.90 0 0 0 0 0 0 `P I=12C-0sw:. .' 0:091 =• 2:55. 126 0 0. 0 0.. 0 0 0: C 4 16A-30md 0.032 - 0.90 2.32 36 36 32 84 180 180 161 418 F ) 22A tpl ; 0:989 . = 27.69 0.00 36 0 0 : -0- 180 .. 12 332 ' 0 6 a)PED excursion -3 -60 Envelope loss/gain 32 81 1394 1711 12 a) Infiltration 0 0 216 61 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 0 0 0 p 1 Appliances/other 1 01 0 Subtotal (lines 6 to 13) 32 81 1609 1772 Less external load Less transfer 0 0 0 0 0 0 0 0 R66stribution 6 14 6 14 14 15 Subtotal Duct loads 38 95 1615 1786 340/6 53% 131 50 34% 53% 541 945 Total room load Ait required (cfm) 51 2 145 6 2156 101 ' 2730 117 ACCA 411- wrightsoft- Right-Suite® Universal 2017 17.0.14 RSU08101 ... k Calcs\Documents\WYNNE-THE WINDSOR-REVISED.rup Calc = MJ8 Front Door faces: Manual 2017-Apr-1017:19:28 Page 3 1 -- wri ghtsoft- Right® Worksheet Job: Entire House Date: QUICK CALLS, INC. By: 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@,AOL.COM 1 Room name DINING/GREAT ROOM KITCHEN 2 Exposed well 50.0 ft 11.0 ft 3 Room height 8.9 ft heat/cool 8.9 ft heat/cool 4 Room dimensions 1.0 x 588.0 ft 19.0 x 11.0 ft 5 Room area 588.0 ft' 209.0 ftz Ty Construction U-value Or HTM Area (ftj Load Area (ft') Load number (Btuhlftk°F) (Btuhlftz) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/PIS Heat Cool Gross NIP/S Heat Cool 6 13A4ocs 0143 .ne 4.90 2.55 0 0 0 0 0 0 0 0 I[ c1om '- 1 270 ne 3556 70.43 0 0 0 0 0'. '0 :0 0 1Ac1om ., 1270 ne:. 3556: 70.43 .. 0 0; .. 0, 0 0, p p 0 1A�1om ,. -. `-1.270 ne ° - 35.56 45;24 0 0 . 0 .. 0 0 0 -`0 ..: 0 11 13A-4ocs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 _ 0 11DO 0390 se 10.92 11.31 0 0 0 0 0 0 0 0 13A-0ocs �' - 4ASf2om 0143sw 0 770 . sw.: 4:00 21:56 2.55... . - 27:53 267 41 .. ; ..226 22 �.' 903 893 574 1140 98 0 � -:9t3 p . •;392 0 .� 249 : 0. 13A-4ocs ' 0.143 nw 4.00 2.55 178 137 549 349 0 0 0 - 0 1Aclom 1.270 nw 35.56 45.24 0 0 0 0 0 0 0 0 ,4AS2omd 0.770 nw 21.56 36.90 41 0 880 1505 0. 0 0 0 P. 12Us*` .:.:_ . -�0 091 : - ' 2:55 .1'.28 0 . 0' 0 : -0 ::. 116 .. :116 - 295 ` :. 148 C 16A-30md 0.032 - 0.90 2.32 588 588 527 1364 209 209 ,` 187 485 0:989 - 27.69 Q00 -588 50 1385 : 0 209, 11 305 : 0 6 c)AED excursion 1004 -64 Envelope loss/gain 5136 5937 1179 818 12 aj Infiltration 1000 282 220 62 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 0 0 Appliances/other p 100 0 Subtotal (lines 6 to 13) 6136 6679 1399 1880 Less external load 0 0 0 0 Less transfer 0 0 0 0 kedistribution 6 14 0 0 14 Subtotal 6142 .6693 1399 1880 1-5 ductloads 34% 53%1 2058 3541 34% 53% 469 995 1Yotal room load AIir required (cfm) 8200 . 386 10234 440 1867 2875 88 124 all -FP- wciglhitsoft• Right -Suite® Universal 201717.0.14 RSU08101 k Calcs\Documents\WYNNE-THE WINDSOR-REVISED.rup .Calc = MJ8. Front Door faces: 2017-Apr-1017:19:28 Page 4 J + wrightsoft RighW@ Worksheet Entire House QUICK CALCS, INC. 317 ST..LUCIE LN., FT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM Job: Date: By: 1 2 3 4 5 Room name Exposed wall .Room height Room dimensions Room area BATH 5.0 ft 8.0 ft heat/cool 10.0 x 5.0 ft 50.0 ft2 HALL 0 ft &0 ft heat/cool 5.0 x 5.0 ft 25.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load I number (Stuh/ft2-°F) (Btuhlft2) or perimeter (ft) (Btuh) or perimeter r (ft) h (Bt) Heat Cool Gross WP/S Heat Cool Gross N/P/S Heat Cool 6 , . V, 13A-4ocs 1Ac1am 1Ao1om 0:143 1270 1 270 ,: ne no' ne: 4:00 35.56 35.56 : 2.55 70.43 70A 40 0 . 0 40 0 0 160 0 0 102 0 s 0 0 0. 0; 0 0 ,.. 0 0 :0. 0 0 0 : 0 11 I 1A c1om `. ` 13A-lots 1' 270 0.143 . ne:• se . .35 b6.. 4.00 45:24 2.55 ` 0 0 . 0 0 :. 6:— 0 -' 0 0 . ='. 0 0 ' , 0 0 . 0 0 p 0 W I---D 11D0 13A-0acs , 13A-4ocs 1A-c1om 4A5-2omd 16A-30md 224tpl:. ,' .. r`, :: 0.390 0;143 O.T/0 0.143 1.270 0.770 0:091 0.032 0.989 se , sw sw . nw nw nw _ :.. _. 10.92 4;U0: 21:56 4.00 35.56 21.5q "2:55 0.90 27.69 11:31 2,'55 . ' 27.53 Z55 45.24 ,. 36.90 .:1528 2.32 > ' 0:00 0 0 - 0 0 0 0 0 50 :. 50 0 0 0 0 0 0 p 50 5 0 = 0 - . 0 0 0 0 0 45 :.138 0 '. .. 0 . 0 0 0 0 O 116 : .. • . 0 0 _ 0 =' 0 0 0 0 f 0 25 - .. 25 0 : p ':.'- 0 0 0 0. ,. ,,0 25 p 0 :. 0' - -0 0 0 0 -. :: ,0 22 ,: : . 0 0 0 0 0 0 0 58 0, yJ C F . GG :' 6 c)1,AED excursion. -8 -2 Fsivelope loss/gain 343 210 22 56 12 a)f b)II Infiltration Room ventilation 90 0 25 0 0 0 0 0 13 Ini!emal gains: Occupants @ 230 Appliances/other 0 0 0 0 0 0 S! Motel (lines 6 to 13) 433 235 22 56 14 15 Less external load Less transfer Redistribution Subtotal Duct loads 34% 53% 0 0 6 439 147 0 0 14 249 . 132 340/4 53% 0 0 -22 0 0 0 0 456 0 0 Total room load Air required (cfm) 586 28 381 16 0 0 0 0, Calculations approved byACCA to meet all requiren -- wrightsoft' . Right -Suite® Universal 2017 17.0.14 RSU08101 k CalcslDocumentsMYNNE-THE WINDSOR-REVISED.rup Calc = MJ8 Front Door faces: N J.8th Ed. 2017-Apr-10 17:19:28 Page 5 wH' htsoft° Right-J® Worksheet Dat Entire House Date: QUICK CALCS, INC. By. I 317 ST LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS AOL.COM 1 Room name FOYER BEDROOM 3 2 Ergx'sed wall 9.0 ft 14.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 1.0 x 92.0 ft 13.0 x 13.0 ft 5 Room area 92.0 ft2 169.0 ftz Ty I Construction U-value Or HTM Area m e Load number (Btuh/ft2 °F) (Btu or perimeter (ft) (Btuh) orsperimete r (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross WP/S Heat Cool 6 1MAocs 0.143 "ne 4:00. 2.55 0 0 0 0 104 88 351 223 IA-c1om 1.270 ne 35.56 70.43 0 0 0 0 0 0. :0 0 1A2c1om 1:270 : ne, 35.58. 70.43 0 0. 0, 0 0 0 0 0 1Ac1om 1.270 ne 35.56 4524 " 0 0 0 0 16 0, -: 581 _• '739 11 W �p 13A4ocs 0.143 se 4.00 2.55 64 41 165 105 0 0 0 0 11DO 0.390 se 10.92 11,31 23 23 248 257 0 0 0 0 W } t-G• 13A flocs`.:: 0.143 sw : 4:00 255 : 8 8 " 32 ' " • - 20 - 8 .. ...:8 . :_32 20. '4Ar2om ' ' 0 Mi . sw.- 21.56 27:M ' 0 0 0', 0 0 :0 0 .0 13AAocs 0.143 nw 4.00 2.55 0 0 0 0 0 0 0 0 1A-c1om 1.270 nw 35.56 45.24 0 0 0 0 0 0 0 0 4A5-2omd 0.770 nw 21.56 36.90 0 0 0 0 0 0 0 0 P. ' i, ` 12C-0sw 0.091 - 2:55 1028 - 88 88 ' 224 113 104 104 265 133 C 16A 30md 0.032 - 0.90 2.32 92 92 82 213 169 169 151 392 F. f" i i '22A-tpl.' 0.989. -" 27.69.` '0.00 92 9 249 -0 169 14-- 388. 0 6 c)AED excursion -25 -52 Eni elope loss/gain 1002 684 1768 1456 12 i a) Infiltration 162 46 252 71 b) Room ventilation 0 0 0 0 13 Intemai gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 1163 730 2020 1527 Less a demal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal '1163 730 2020 1527 15 Duct loads 34% 53% 390 386 34°/a 53% 677 808 1 Total room load 1553 1116 1 1 2697 2335 Air required (cfm) 73 48 127 100 ACCA to Ed. wrightsoft- Right -Suite® Universal 2017 17.0.14 RSU08101 2017-Apr-10 17:19:28 �A ...k Calcs\Documents\WYNNE-THE WINDSOR-REVISED.rup Cale = MA Front Door faces: N Page 6 .� Job: - - wrightsofta Duct System Summary Date: Entire House By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799Fax 772-466-6796 Email;. QUICKCALCS@AOL.COM For: WYNNE DEVELOPMENT THE WINDSOR, FT. PIERCE, FL I I Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.50 in H2O 0.50 in H2O Supply % return available pressure 0.250 / 0.250 in H2O 0.250 / 0.250 in H2O Lowest friction rate 0.273 in/100ft 0.273 in/100ft Actual air flow 1160 cfm 1160 cfm Total effective length (TEL) 183 ft I Name Design (Btuh) Htg (Cfm) Clg (cfm) Design FIR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH h 586 28 16 0.372 4.0 OxO VIFx 19.5 115.6 stl _. BEDROOM 2 c 2730 101 117 0.384 7.0 0x0 VIFx 15.0 115.0 stl BEDROOM 3 h . 2697 127 100 0.353 6.0 Ox 0 VIFx 26.8 115.0 st1. DININGIGREATROOM c 3411 129 147 0.292 7.0 Ox0 VIFx 36.5 135.0 st2 DINING/IIGREATROOM-B C 3411 129 147 0.371 7.0 OxO VIFx 19.9 1115.0 stl DINING/GREATROOM-C C 3411 .129 147 0.278 7.0 Ox0 VIFx 44.9 135.0 st2 FOYER! h 1553 73 48 0.490 4.0 Ox 0 VIFx 7.0 95.0 KITCHEN C 2875 88 124 0.366 6.0 Ox0 VIFx 21.8 115.0 stl LAUDRY c 145 2 6 0.371 4.0 Ox 0 VIFx 19.9 115.0 SO M. BATH h 1091 51 50 0.282 6.0 Ox0 VIFx 42.3 135.0 st2 MASTER BEDROOM h 3190 150 124 0.273 6.0 OxO VIFx 48.4 135.0 st2 MASTER BEDROOM -A h 3190 150 124 0.284 6.0 Ox0 VIFx 40.9 135.0 st2 wlc c 216 4 9 0.292 4.0 Ox 0 VIFx 36.0 135.0 st2 Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (Cfm) FR (fpm) (in) (in) Material Trunk I st2 Peak AVF 612 602 0.273 780 . 12.0 0 x 0 VinlFlx SO st1 Peak AVF 1087 1112 0.273 796 16.0 0 x 0 VinlFlx -}-1. wri htsoft' 2017-Apr-1017:19:29 f Right -Suite® Universal 2017 17.0.14 RSU08101 Page 1 ... k Calcs\Documents\WYNNE-THE WINDSOR-REVISED.rup Calc = MJB Front Door faces: N v Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Matl Trunk' rb1 Ox0 1160 1160 0 0 0 0 Ox 0 VIFx 2017-Apr-10 17:19:29 wrightsoft' Right -Suite® Universal 2017 17.0.14 RSU08101 Page 2 '� .I.k Calcs\Documents\WYNNE-THE WINDSOR-REVISED.rup Calc = MJ8 Front Door faces; N