HomeMy WebLinkAboutPROJECT SUMMARYPro ect Sum Job: -- wrightsoft Date: Entire House By: QUICK CALCS, INC. 311 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772466-6799 Fax 772466-6796 Email: QUICKCALCS AQL.COM. Project Information For: THE GRAND CARLTON WYNNE DEVELOPMENT, FT. PIERCE, FL SCANNED) Notes: BY StLucie County Design Information Weather. Fort Pierce, FL, US Winter Design Conditions Outside db 42 OF Inside db 70 OF Design TD 28 OF I i Heating Summary Structure 17848 Btuh Ducts 5654 Btuh Central vent (0 cfm) 0 Btuh (none) Humidification 0 Btuh Piping 0 Btuh Equipment load 23503 Btuh Infiltration Method Construction quality Fireplaces Area (ft2) Heat' ngg 1446 Volume (ft3) 12511 Air changes/hour 0.45 Equiv. AVF (cfm) 94 Summer Design Conditions Outside db 90 OF Inside db 75 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 gr/lb Sensible Cooling Equipment Load Sizing Structure 17520 Btuh Ducts 8536 Btuh Central vent (0 cfm) 0 Btuh (none) Blower 0 Btuh Use manufacturer's data n Rate/swingg multiplier 0.95 Equipment sensible load 24753 Btuh Simplified Latent Cooling Equipment Load Sizing Average 0 Structure 3203 Btuh Ducts 2318 Btuh Central vent (0 cfm) 0 Btuh Cool' ng (none) 1446 Equipment latent load 5521 Btuh 12511 0.23 Equipment total load 30274 Btuh 48 Req. total capacity at 0.70 SHR 2.9 ton Heating Equipment Summary Make Carrier Trade CARRIER AIR CONDITIONING Model 25HBC536A*030 AHRI ref 7914585 Efficiency Heating Input Heating output Temperature rise Actual air flow. Air flow factor Static pressure Space thermostat Capacity balance point = 32 OF Backup: 8.5 HSPF 34600 Btuh @ 47°F 27 OF 1160 cfm 0.049 cfm/Btuh 0.50 in H2O Cooling Equipment Summary Make Carrier Trade CARRIER AIR CONDITIONING Cond 25HBC536A*030 Coil' FX4DN(B,F)037 AHRI ref 7914585 Efficiency 12.0 EER, 15 SEER Sensible cooling 24360 Btuh Latent cooling 10440 Btuh Total cooling 34800 Btuh Actual air flow 1160 cfm Air flow factor 0.045 cfm/Btuh Static pressure 0.50 in H2O Load sensible heat ratio 0.83 Input = 7 kW, Output = 23009 Btuh, 100 AFUE Calculations approvedby A, to meet all requirements of Man I IL �-- wrightsoft` Right -Suite® Universal 201717.0.14 RSU08101 ACCk ..uick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N "OpyMari 2017-Apr-11 09:29:38 Page 1 - wrightsoft, Right-J® Worksheet Job: Entire House Date: By: QUICK CALCS, INC. 317 ST. LUCIE rLN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name Entire House BEDROOM 2 F�osed wall 166.2 ft 49.0 ft 3 Room height 8.7 ft d 8.0 ft heaticool 4 5 Room dimensions Room area 1445.5 ftz 1.0 x 297.0 ft 297.0 ft' Ty Construction U-value Or HTM Area (ft') Load Area (ft') Load number (Btuh/ft- °F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) . Heat Cool Gross N!P/S Heat Cool Gross N/P/S Heat Cool 6 ` A3AAocs... - AA5-2om' .` " 0 143 0.770. n, 'n' 4.00. 21.56 , 2.55 - ' 19.31 503 - 38 '. 465 0. 1862 815 . 1184 : 730 ',. _. 72 0 12. ' ' 0 286 •' '0 183 . ` 0 W, 13A-4ocs 0.143 a 4.00 2.55 128 83 333 212 0 0 0 0 11 1Aclom 11DO 1.270 0.390 a a 35.56 10.92 87.29 11.31 24 21 2 21 848 229 2082 238 0 0 0 0 0 0 0 0 IL::GG W tLV+! 13A4ocs 13A-4ocs 0.143 0.143 se s 4.00 4.00 2.55 2.55 34 360 34 353 136 1414 86 899 0 216 0 216 0 . 865 0 550 '' G 1Ac1om 1.270 s 35.56 34.77 7 7 247 241 0 0 0 0 13A-4ocs, 1A-c1om - - 0.143 -1.270 w� . w 4.00 35.56 2.55 55.21 310 32 237 2 949 . 1140 603 1770 104 32 72 2 288 : 1140 - 183 1770 12C-0sw _.16A=30md 0;770 0.091 0:032 w - - 21.56 2.55 0.90 19.31 1.28 2.32 41 192 1446 41 192 .1446 880 489 - 1295 :. 788 246 . 3354 0 0 297. - '. 0 _ 0 297 : 0 0, ' 266 0 0 ,- 689 P C , F i 22A-tpl 0.989 - 27.69 0.00 1446 156 4325 0 297 49 1357 0 6 c)AED erxursion 918 627 Errvelope loss/gain 14961 13349 4204 4003 12 a) Infiltration 2887 791 848 232 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 6 1380 3 690 Appliances/other 2000 0 Subtotal (lines 6 to 13) 17848 17520 5053 4925 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 15 Subtotal Duct loads 1 32% 49% 17848 5654 17520 8536 32% 49% 5053 1601 4925 2400 1 Total room load Air required (cfm) 23503 1160 26056 1160 6653 328 7325 326 Calculations to meet all' wrightsoft� 2017-Apr-11 09:29:38 A Right -Suite® Universal 2017 17.0.14 RSU08101 Page 1 ..ulck Calcs\Documents\THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N -- w'r9htsoft' Right-M Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772466-6799 Fax 772.466-6796 Email: OUICKCALCS@AOL.COM 1 Room name WIC KrrCHEN 2 F used wall 0 ft O ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 RQom dimensions 6.0 x 9.0 ft 1.0 " x 172.0 ft 5 Room area 54.0 ft2 172.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load . Area (ft2) Load number (Btuh/ft?-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross WP/S Heat Cool 6 13A-0ocs : A 143 n �, 400; '56 2:55 ` 0 ' - 0 0 ' 0 ; 0. . ':,4A5 tom :" 0.770 n: 21 19 31 0 . 0 R :0 0 :0. P13A-0ocs 0.143 a 4.00 2.55 0 .0 0 0 0 0 0 0 1A-c1om 1.270 a 35.56 87.29 0 0 .0 0 0 0 0 0 11 11DO 0.390 a 10.92 11.31 0 0 0 0 0 0 0 0 -D--DDD W -.13A4ocs 0.143 . se .4.00 2:55 0 0 0 0 0 0 0 0 Vff L 13A4ocs 0.143 s 4.00 2.55 0 0 0 ,- 0 0 0 0 0 1A-c1om 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0 vv 13A4&s : 0.143 . w 4:00 2.55 0 0 0 .0 .0 0 0 - 0 !A-c1om 1.270 w. 35.56 55.21 0 0 0 0 0 0. 0 0 05-2om :. 0.770 .w 21.56 19:31 0 . 0 0 .0 0 .0 . 0 0 P 12C-0sw 0.091 2.55 1.28 0 0 0 0 64 64 163 82 C 16A30md ,0.032.: =. 0190 2;32 . 54 54 48; 125. 172 172 154 399 F 22A tpl 0.989 - 27.69 ff 0.00 54 0 0 0 172 0 0 0 6 c)�ED excursion -9 -170 Envelope loss/gain 48 117 317 311 12 a) Infiltration 0 0 0 0 b) 1 Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other p 2000 Subtotal (lines 6 to 13) 48 117 317 2311 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 14 15 Subtotal Duct loads 48 117 317 .0 2311 32% 49% 15 57 32% 49% 100 1126 I Total room load Air; required (cfm) 64 174 418 3437 3 g 21 153 Calculations approved byACCA to meet all requirements of Aft '�' WCightsoft " Right -Suite@ Universal 2017 17.0.14 RSU08101 ...uick CalcslDocumentslTHE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N 2017-Apr=11 09:29:38 Page 2 I wrightsoft Right4@ Worksheet Job: Entire House Date: QUICK CALLS, I INC. By: 317 ST. LU,GlE,LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Email: QUICKCALCS@AOLCOM I Ro6 name BATH BEDROOM 2 2 wall tneight 5.0 ft 34.2 ft 3 8.,0 ft heat/cool 8.0 ft heat/cool 4 R06M dimensions 9.0 x 5.0 ft 1.0 x 203.5 ft 5 Ro6rn area 45.0 ft2 203.5 ft2 Ty Construction U-value Or HTM Area (ft) Load Area (ft2) Load number Btuh1ft2m*F) (Btu 2) 'or perimeter (ft) (Eat h) or perimeter (ft) (Btuh) Heat Cool Gross N/PIS Heat Cool Gross N/PIS Heat Cool 6 .� -W 0.1434'00 -2115 2Z5 40 40 160 -.102 .128 ,,128 .518 :'-326 .or .770 0.143 n; a 4.00 19.31: 2.55 0,-, 0 _0 0 Z 0 0 0 0 80 0. 56 225 143 11G 1= om 1270 e 35.56 87.29 0 0 0 0 24 2 848 2082 11 11DO 0.390 a 10.92 11.31 0 0 0 0 0 0 0 0 -.13A4ocs 0.143 se 4 00 2.55- 0 .0 0 0 34 .34 136 86 t13A,4ocs 0.143 s 400 2.55 0 0 0 0 32 k 128 81 1A-c1orn 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0 -0 �Ve '13A4ocs 0.143, W 4.00 2.55 0, 0 0 0 0 -,0- 0 0 -.270 -:w 35;56 55.21 0 0 0 % 0 0'... 0 . 0 4A5 tom 9-3770 --...w 21:56 . 0 0 .0 0 o 0 12C-0sw 0.091 2.55 1.28 0 0 0 0 0 0 0 0 -01032 :0.90 2.32 45, 45, -40 104 204 264 182 472 F 22A-tpl .0.989 27.69 k 0.66 45 5 138 0' 204 34 946 0 6 c) AED excursion -16 -85 Envelope loss/gain 339 196 2978 3106 12 a) Infiltration 1 87 24 593 162 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0� 01 1 230 Appliances/other 0 0 Subtotal (lines 6 to 13) 425 214 3571 3498 Les's external load Leis transfer 0 0 0 0 0 0 0 Redistribution 0 0 0 0 14 15 Subtotal D* loads 425 214 3671 3498 32016 49% 135 1d4 32% 49% 1131 1704 Total room load 569 3181 1 47021 5203 1 1 Air, required (cfm) 28 14 232 232� wrightsoft- AMCK Right -Suite® Universal 2017 17.0.14 RSU08101 ... ulck CalcsIDocuments\THE GRAND CARLTON-1446.rup Calc=MJB Front Door faces: 2017-Apr-11 09:29:38 Page 3 -t - wi>; ightsoft° Right-M Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS AOL.COM 1 Room name LAUNDRY GREAT/DINING 2 Eosad wall 6.0 ft 47.0 ft 3 4 5 Room height Room dimensions Room area 8.0 ft heat/cool 7.0 x 6.0 ft 42.0 ftz 9.8 ft heat/cool 1.0 x 526.0 ft 526.0 ftz Ty Construction U-value Or HTM Area (ftz) Load Area (ft.) Load number (BtuWftz--°F) (Btuh/W) or perimeter (ft) (Btuh): or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 �-�G 13A flocs.. 4A5 2orri ." 13AAocs 0A43 A770 0.143 - n - ri ` a 4:00 21.56 4.00 2:55 ` : 19.31 2.55 0 0 0 0 .:. 0 0 0 0 0 0 0 0 .. 255 38 0 . 217 '- : '0 0 , •'869 . 815 0 552 .., 730. 0 11 1A-c1om 11DO 1.270 0.390 a a 35.56 10.92 87.29 11.31 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 D W. t-G .13AAocs 13AAocs 1A-c1om 0.143 0.143 1.270 se s s .4.00 4.00 35.56 2.55 2.55 34.77 0 48 0 0 48 0 0 192 0 0 122 0 0 0 0 0 0 0 0 0 0 0 0 0 �I/-G 13A46cs 1A�1om 0.143 1.270 w w 4.00 35:56 2.55 55.21 0 0 0 0 0 0. 0 0 206 0 165 r 0 661 0 420 0 E' C 4A52om 12C-Osw -16A30md :. 0.770 0.091- 0.032` w - - 21.56 2.55 .0.90 19.31 1.28 2.32 0 56 42 0 56 42 0. 143 38 0 72 .. 97 41 0. -526. 41. 0 526. 880 0 788 0 -1220 P .0 F 22A tpl 0.989 - 27.69 0.00 42 6 166 0 526 ,- 47 ,•'471, 1302 0 6 c)AED wcursion -22 668 Envelope loss/gain 539 270 4997 4379 12 a) Infiltration 104 28 997 273 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 2 460 j Appliances/other 0 0 Subtotal pines 6 to 18) 643 298 5994 5112 14 15 Less extemal load Less transfer Redistribution Subtotal Duct loads 1 32% 49% 0 0 0 643 204 0 0 0 298 145 32% 49% 0 0 0 5994 1899 0 0 0 5112 2490 Total room load Air, required (cfm) 846 42 443 20 ' 7892 390 7602 338 Calculations rements of Manual, .Q... `P- wrightsoft- Right -Suite® Universal 2017 17.0.14 RSU08101 2017-Apr-11 09:29:38 Ab-dilk...uick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N Page 4 +- wr ghtsoft Right-J® Worksheet Entire House QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772A66-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM Job: Date: ,By: 1 • Room name FOYER M. BATH 2 F�rosed wall 7.0 ft 8.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 1.0 x 50.0 ft 7.0 x 8.0 ft 5 Room area 50.0 ftz 56.0 ft' Ty Construction U-value Or HTM Area (ftz) Load Area (ft2) number (Btuh/ft'L-°F) (Btuh/ftz) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 { :13AAom ,: . 0.143 n, . 4.00 2:55 8 . 8 32 : 20 0: 0 0 ` • 0 21.56 -19.31 0 .. .. 0 0. ... 0 0 :0. 0 0 13AAocs 0.143 a 4.00 2.55 48 27 108 69 0 0 0 0 1A-c1om 1.270 a 35.56 87.29 0 0 0 0 0 0 0 0 11 D 11DO 0.390 a 10.92 11.31 21 21 229 238 0 0 0 0 W .13AA6cs 0.143 se 4.00 2.55 0 0 0 0 0 0 0, 0 VI/ r-- C 13AAocs 0.143 s 4.00 2.55 0 0 0 0 64 57 228 145 1A-clom 1.270 s 35.56 34.77 0 0 0 0 7 7 247 241 1 13AAocs 0.143 w 4:00 2.55 0 0 0 0 0 0 0 0 1A-olom 1.270 w 35.56.. 55:21 0 0 0 0 0 0 0 0 LtG 4A5 tom. .0.770 w 21.56 1931 0 0 0". 0 0 0. 0 0 P 12C-0sw 0.091 - 2.55 1.28 72 72 183 92 0 0 0 0 C.,. 16Ar30ind 0:032'' - Oi90. 2.32 .50 50 45 . 116 56 -56 -50 z130 F t L � i 22A-tpl 0.989 - 27.69 0.00 50 7 194 0 56 8 . 222 0 6 c)AED excursion -39 Envelope loss/gain 792 496 747 478 12 a) Infiltration 121 33 138 38 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 1 Appliances/other 0 0 Subtotal (lines 6 to 13) 913 529 .885 516 Less a)d mal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 913 529 885 516 .151 Duct loads 32% 49% 289 258 32% 49% 280 251 Total room load T1202 787 1166 768 Airjrequired (cfm) 59 351 1 1 58 34 .Calculations approved bVACCA to meet all requirements of Manual J 8th Ed. wrightsoft' Right -Suite® Universal 2017 17.0.14 RSU08101 2017-Apr-11 09:age 5 Page 5 ...uick CaIcslDocuments\THE GRAND CARLTON-1446.rup Calc = MJB Front Door faces: N ` I Job: -- wrightsoft° Duct System Summary Date: Entire House By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone; - 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM For: THE GRAND CARLTON WYNNE DEVELOPMENT, FT. PIERCE, FL Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.50 in H2O 0.50 in H2O Supply) return available pressure 0.250 / 0.250 in H2O 0.250 / 0.250 in H2O Lowest friction rate 0.285 in/100ft 0.285 in/100ft Actual air flow 1160 cfm 1160 cfm Total effective length (TEL) 176 ft Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH ; h 560 28 14 0.364 4.0 OxO VIFx 22.4 115.0 st1 BEDROOM 2 h 4702 232 232 0.360 7.0 Ox 0 VIFx 23.9 115.0 st1 BEDROOM -A h 3327 164 163 0.300 6.0 Ox 0 VIFx 31.8 135.0 st2 BEDROOM-B h 3327 164 163 0.285 6.0 Ox0 VIFx 40.6 135.0 st2 FOYER h 1202 59 35 0.505 4.0 OxO VIFx 4.0 95.0 GREAT/DINING h 3946 195 169 0.300 7.0 Ox0 VIFx 31.8 135.0 st2 GREAT/DINING-A h 3946 195 169 0.300 7.0 Ox0 VIFx 31.8 135.0 st2 KITCHEN c 3437 21 153 0.379 6.0 OxO VIFx 17.0 115.0 st1 LAUNDRY h 846 42 20 0.361 4.0 Ox0 VIFx 23.3 115.0 st1 M. BATH -A h 768 58 34 0 0 Ox 0 VIFx 0 0 WIG c 174 3 8 0.309 4.0 Ox0 VIFx 27.0 135.0 st2 Supply Trunk®etail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st2 PeakAVF 721 672 0.285 918 12.0 0 x 0 VinlFlx st1 SO Peak AVF 1043 1091 0.285 1020 - 14.0 0 x 0 VinlFlx .` I wd htsoft6 2017-Apr-1109:29:38 � 9 Right -Suite® Universal 2017 17.0.14 RSU08101 1-m -,ick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N Page 1 Return Branch Detail Table Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FIR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb1 Ox 0 1160 1160 0 0 0 0 Ox 0 VIFx wri htsoft° ' 2017-Apr-11 09:29:38 9 Right -Suite® Universal 2017 17.0.14 RSUG8101 Page 2 ...uick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N